K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
ABB-2600T-Pressure Transmitter family
❤ Add to collection

ABB-2600T-Pressure Transmitter family

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

ABB actively promotes environm ental awareness and has an operational management  system that meets the requirements of DIN EN ISO 9001:2000, EN ISO 1 4001:2004,  and OHSAS 18001. Our products and solutions are intended to have minimum impact on  the environment and persons during manufacturing, storage, transport, use and disposal.  This includes the environmentally friendly use of natural resources. ABB conducts an  open dialog with the public through its publications.  This product/solution is manufactured from materials that can be reused by specialist  recycling companies.

12456.00
¥12111.00
Weight:4.800KG
Quantity:
(Inventory: 111)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

ABB actively promotes environm ental awareness and has an operational management  system that meets the requirements of DIN EN ISO 9001:2000, EN ISO 1 4001:2004,  and OHSAS 18001. Our products and solutions are intended to have minimum impact on  the environment and persons during manufacturing, storage, transport, use and disposal.  This includes the environmentally friendly use of natural resources. ABB conducts an  open dialog with the public through its publications.  This product/solution is manufactured from materials that can be reused by specialist  recycling companies.


ABB-2600T-Pressure Transmitter family

Transport and storage  • After unpacking the pressure transmitter, check the device for transport damage.  • Check the packing material for accessories.  • During intermediate storage or transport, store the pressure transmitter in the original packaging only.  For information on pe rmissible ambient conditions for storage and transport, see "Te chnical data". T he  storage time is indefinite, however, the warranty conditions stipulated in the order confirmation of the supplier  are valid.  The transmitter package includes:  ƒ The transmitter  ƒ An envelope including the instruction manual and the calibration report  ƒ 3 mm Allen key  ƒ Optional content depending on the selected options:  ƒ Bracket kit  ƒ Electrical connection blind plug  Identification  The instrument is identified by the data plates.  Nameplate  The Nameplate provides information concerning the model cod e number, maximum working  pressure, range and span limits, power supply and output signal. See code/specification sheet for  detailed information. This plate also shows:  ƒ the transmitter serial number (please refer to this number in making inquiries)  ƒ the specific details of the transducer (diaphragms material, fill fluid, range limit and identification  number)  ƒ the Safety Hazardous Area details (see the specific paragraph in this manual)

As already specified in t he Safety Notes th e installation must only be carried out by suitably trained  personnel and in accordance with the information given. Any deviation from these instructions, will transfer  the complete liability to the user.  It is not recommended to install the transmitter and leave the cover open or the electical input without the  appropriate plugs. Water penetration can damage the electrical circuit.  General  .  Preparing for installation  Before installing the pressure transmitter, check whether the model meets the measurement and safety  requirements of the measuring point. This applies for:  • Measuring range  • Overpressure stability  • Temperature  • Explosion protection  • Operating voltage  The materials must be checked to ensure compatibility with regard to their resistance to the media.  This applies for:  • Gaskets  • Process connections, etc.  In addition, the relevant directives, regulations, standards and accident prevention regulations  must be observed. (e.g., VDE/VDI 3512. DIN 19210. VBG, Elex V, etc.).  Measurement accuracy is largely de pendent on correct installation of the pre ssure transmitter and, if  applicable, the related m easuring tube. The m easuring setup should be as free as possible of critical  ambient conditions such as major temperature variations, vibration or shock.  Note  If unfavorable ambient condition s cannot be avo ided owing to rea sons related to bu ilding structure,  measuring requirements or other reasons, this may influence the measurement quality.  If a pressure sensor with capillary tube is installed, observe also the related data sheets.  Pressure transmitter  The transmitter can be connected directly to the shut-off valve. There is also a mounting bracket for wall or  pipe installation (2” pipe) available as an accessory.  The pressure transmitter should be installed so that the di splay and control unit are a ccessible during  installation and connection, as well as retrofitting.  The transmitter should be installed preferably in a vertical position to avoid subsequent zero shift corrections.  Note  In case of an oblique installation and depending on the measuring range, the fill fluid exerts a hydrostatic  pressure on the measuring diaphragm, resulting in a zero shift. The zero point must then be adjusted.  In general, the pressure transmitters can be used in any mounting position. It is installed according to the  same guidelines as a manometer


  • Electric tricycle truck, agricultural tricycle, elderly vehicle, warehouse truck
  • GE 8042-CC-85 Carrier extension cable, 0.85m
  • GE 8086-FC-20 20 + 24 pin cables for 8619 (2m)
  • GE 8041-CC-35 Carrier extension cable, 0.35m
  • GE 8085-FC-10 20 + 24 pin cables for 8619 (1m)
  • GE 8034-CC-12 Intrinsically Safe Carrier Extension
  • GE 8082-FC-30 16-pin cable for 8618 (3m)
  • GE 8030-CE-RH Intrinsically Safe Carrier extender, right hand
  • GE 8080-FC-10 16-pin cable for 8618 (1m)
  • GE 8021-CE-LH Carrier extender, left hand
  • GE 8044-CC-20 Carrier extension cable, 2.0m
  • GE 8725-CA-RB Railbus isolator carrier with PFM
  • GE 8712-CA-NS Node services carrier, Profibus-DP LAN
  • GE 8724-CA-PS Intrinsically Safe module power supply carrier
  • GE 8711-CA-NS Node services carrier, screw terminal LAN
  • GE 8723-CA-RB Railbus isolator carrier
  • GE 8606-FT-RT Field terminal, RTD
  • GE 8620-FT-MT Field terminal assembly
  • GE 8604-FT-FU Field terminal, fused
  • GE 8617-FT-NI Field Terminal, non-incendive, for 16 ch DI
  • GE 8601-FT-NI Field terminal, non-incendive (Div 2)
  • GE 8215-DO-IS 4-channel Intrinsically
  • GE 8202-HO-IS 8-channel Intrinsically Safe Analog Output, 4-20 mA with Hart
  • GE 8206-TI-IS 8-channel Intrinsically Safe RTD input
  • GE 8201-HI-IS 8-channel Intrinsically Safe Analog Input, 4-20mA with Hart
  • GE 8117-DO-DC 8-channel DO, 2-60Vdc isolated, unpowered
  • GE 8810-HI-TX 8-Channel Safety AI, 4-20mA with HART
  • GE 8142-DO-DC 16-channel Digital Output
  • GE 8140-DI-AC 16-channel Digital Input, 115VAC isolated, sinking
  • GE 8112-DI-AC 8-channel DI, 115Vac non-isolated, module powered
  • GE 8139-SH-DC 126-channel Addressable Smoke and Heat
  • GE 8111-DI-AC 8-channel DI, 115Vac isolated, sinking
  • GE 8133-HI-TX 8-Channel Supervised AI with HART
  • GE 8110-DI-DC 8-channel DI, 24Vdc non-isolated, module powered
  • GE 8109-DI-DC 8-channel DI, 24Vdc isolated, sinking
  • GE 8129-IO-DC 8-channel Supervised Discrete I/O
  • GE 8106-TI-RT 4-channel RTD input
  • GE 8127-DI-SE 32-channel SOE module
  • GE 8105-TI-TC 4-channel THC/mV input
  • GE 8125-DI-DC 32-channel DI, non-isolated, module-powered
  • GE 8104-AO-IP 8-channel AO, 4-20mA
  • GE 8122-DI-DC 16-channel DI, 24Vdc isolated, sinking
  • GE 8103-AI-TX 8-channel AI, 4-20mA
  • GE 8121-DI-DC 16-channel DI, 24Vdc non-isolated
  • GE 8102-HO-IP 8-channel AO, with HART for 4-20mA
  • GE 8119-VI-05 8-channel Voltage Input, 1-5Vdc
  • GE 8101-HI-TX 8-channel AI, 4-20mA with HART
  • GE 8755-CA-NS EBIM carrier
  • GE 8522-EB-MT Ethernet Bus Interface
  • GE 8752-CA-NS Universal Node Services Carrier
  • GE 8515-BI-PN PROFINET Scanner Module
  • GE IC754VBI12CTD Touch Screen
  • GE IC754VGI10MTD Touch Screen
  • GE IC754VBI1OMTD Touch Screen
  • GE IC754VSL12CTD QuickPanel
  • GE IC754VBL12CTD QuickPanel
  • GE IC754CGL12CTD QuickPanel
  • GE IC754CBL12CTD QuickPanel
  • ABB TZIDC Digital Positioner
  • ABB NextMove ESB-2 motion controller
  • ABB Advant Controller 70
  • ABB Advant Controller 250
  • ABB ACS850-04 drive modules
  • ABB IRB 4600 Industrial Robot
  • ABB IRB 910SC SCARA
  • ABB Product specification IRB1200
  • ABB DCV 700 thyristor panels
  • ABB Advant Controller 160
  • ABB Serial Communications Module RS232
  • ABB PP886 Compact Product Suite hardware selector
  • ABB Panel 800 version 6
  • ABB Uvisor™ FAU810 – Flame Analysis Unit
  • ABB Switches Automatic Transfer Switches
  • ABB Dynamic braking / DC drive
  • ABB Automatic Transfer Switch OTM_C_21D
  • ABB Switches Change-over and transfer switches
  • ABB PGC2000 Series Process Gas Chromatograph
  • ABB PGC5000 Series gas chromatographs
  • ABB DBDID Process gas chromatographs
  • ABB Vapor Pressure (RVP) analyzers
  • ABB Distributed busbar protection REB500
  • ABB SYNCHROTACT® upgrade Keep your assets synchronized, safe and productive
  • ABB SYNCHROTACT® Datasheet Synchronizing devices and systems
  • ABB C310 Wall- / Pipe-mount universal process controller
  • ABB AP100 pH/Redox (ORP) cartridge sensors with water-wash option
  • ABB Title this is title and subtitle this is subtitle Power Factor Controller RVC Accurate control and monitoring of capacitor banks
  • ABB FOUNDATION Fieldbus Linking Device LD800HSE EX
  • ABB Remote Terminal Unit RTU560
  • ABB MEASUREMENT & ANALYTICS TEIP11
  • ABB MEASUREMENT & ANALYTICS Navigator 540
  • ABB For electromagnetic flowmeters FXE4000-DE43F
  • ABB COM610 Communication Gateway
  • ABB Symphony Plus S+ Control BRC410
  • ABB Symphony Plus SD Series PROFIBUS Interface: PDP800
  • ABB Symphony Plus SD Series HART I/O: HAI805 and HAO805
  • ABB Symphony Plus S+ Turbine: Auto Synchronizer Module AS800
  • ABB S900 I/O Application-Guide CI920S/CI920B replaced by CI920AS/CI920AB
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB IndustrialIT System 800xA S800 I/O System
  • ABB Advant® Master S100 I/O system
  • ABB Ability™ Symphony® Plus MR Series (Melody Rack)
  • ABB Data Sheet ControlIT Harmony Analog I/O
  • ABB Bailey* network90 Loop Interface/Bus Interface(LIM/BIM)
  • ABB Bridge Controller and Process Bus Adapter BRC-300 and PBA-200
  • ABB Kent Morrisey, Business Development Manager – Harmony Evolution NA Harmony Evolution Options For Process Industries Users
  • ABB Industrial'T System 800xA Harmony/INFI90 System
  • ABB Ability™ Symphony® Plus HR Series Control and I/O
  • ABB AC700F controller with direct S700 I/O
  • ABB ContransIthe family with Instruction Manual for Freelance 2000
  • ABB AC servo motors BSM Series
  • ABB BSD Series
  • ABB ControlMaster CM10 Universal process controller, 1/8 DIN
  • ABB PGC2000 Advance Training Course Synopsis
  • ABB PGC5000 Series gas chromatographs
  • ABB EasyLine EL3000 Series Continuous gas analyzers
  • ABB AO2000 Advance Optima Continuous gas analyzers
  • ABB Advant® Controller 450
  • ABB Advant® Controllers
  • ABB Ability™ System 800xA
  • ABB Advant® Master S100 I/O system
  • ABB SYNCHROTACT®5 Operating Instructions
  • ABB Web Tension Systems with Tension Electronics PFEA111
  • ABB Pressductor Pillowblock Load Cells Vertical Measuring PFCL201
  • ABB Force Measurement Products Cold rolling and processing of steel
  • ABB DCS800 Drives
  • ABB MNS iS motor control center
  • ABB Condition MonitoringMService