K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
Abaco XVR19 Intel Xeon Based VME Single Board  Computer
❤ Add to collection

Abaco XVR19 Intel Xeon Based VME Single Board Computer

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

Abaco Systems’ XVR19 6U VME Single Board Computer (SBC) features the Intel  Xeon quad core processor (up to 8 MByte Last Level Cache) with error checking and  correction (ECC) support, integrated graphics and PCI Express (PCIe) channels. The  XVR19 is also equipped with Intel’s CM238 Chipset, supporting PCIe Gen 3,  allowing higher data transfer rates and more PCIe channels. The CM238 chipset also  provides SATA, USB 3.0, graphic ports, SMBus, LPC and SPI design on the XVR19

75676.00
¥66886.00
Weight:5.500KG
Quantity:
(Inventory: 3)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

Abaco Systems’ XVR19 6U VME Single Board Computer (SBC) features the Intel  Xeon quad core processor (up to 8 MByte Last Level Cache) with error checking and  correction (ECC) support, integrated graphics and PCI Express (PCIe) channels. The  XVR19 is also equipped with Intel’s CM238 Chipset, supporting PCIe Gen 3,  allowing higher data transfer rates and more PCIe channels. The CM238 chipset also  provides SATA, USB 3.0, graphic ports, SMBus, LPC and SPI design on the XVR19


Abaco XVR19 Intel Xeon Based VME Single Board  Computer

1.1 Features

• Single-slot 6U VME Single Board Computer

• Intel Xeon quad core processor

• Two channels of soldered DDR4 SDRAM with ECC up to 32 GByte

• Up to 8 MByte Internal CPU shared cache

• Up to 64 GBytes of BGA NAND SSD (Optional)

• Onboard Expansion Sites (supporting either XMC or PMC)

o Site 1 (PMC rear I/O routed to P2)

▪ XMC1 – x8 PCIe

▪ PMC1 – PCI-X up to 64-bit

• 100 MHz (with option of two PMC sites)

• 133 MHz (with option of one PMC site)

o Site 2 (PMC and XMC rear I/O routed to P0) - Optional

▪ XMC2 – x4 PCIe

▪ PMC2 – PCI-X up to 64-bit / 100 MHz

• Comprehensive range of front and rear I/O features:

1.1.1 Front I/O with only One Expansion Site:

• 2x Gigabit Ethernet ports via Intel I210

• 1x DisplayPort

• 3x USB 3.0 ports

• 1x COM port

• 1x Power button

• 1 x eSATA 

1.1.2 Front I/O with Two Expansions Sites:

• 1x Gigabit Ethernet port via Intel I210

• 1x DisplayPort

• 1x USB 3.0 port

• 1x COM port

• 1x Power button

1.1.3 Rear I/O via Transition Module: (Option-Dependent)

• 2x Gigabit Ethernet ports

o 1x Gigabit Ethernet via Intel I219

o 1x Gigabit Ethernet via Intel I210

• 2x Digital Video Interface (DVI-D)

• 4x SATA ports, Gen 2 capable

• 2x COM ports

• 2x USB 2.0 ports

• 8x General Purpose Input/Output (GPIO)

• 1x PMC rear I/O

• 2x Mezzio connectors (PMC/XMC)

NOTE

The VTM29 Rear Transition Module only supports the XVR19 in the environment specified for build level 1. 

See level 1 details in Table A-3.

1.1.4 Other Features

• UEFI Flash and UEFI backup Flash

• Optional extended operating temperature range

• Three levels of ruggedization

The XVR19 offers two optional onboard mezzanine expansion sites for enhanced 

system flexibility, PMC- and XMC- compatible.

Memory resources include up to 32 GByte DDR4 SDRAM and up to 64 GByte 

NAND Flash drive.

Software choices include comprehensive Built in Test (BIT and OS 64-bit support for 

Microsoft® Windows® 10, Fedora and Redhat Linux® and VxWorks®.

1.2 Available Accessories

The following table lists the accessories that are available for the XVR19.

Table 1-1 Available Accessories

Item Purpose

VTM29 Rear Transition Module, 6U x 4HE/HP

YLB-CR12-01 10 pin har-link® to COM Port Sub-D 9 pins 

adapter cable

1.3 Software Support

The XVR19 provides Intel Xeon processor with four cores with a shared memory and 

I/O resource pool. Customer system applications call for software platforms that 

support Symmetric Multiprocessing (SMP) operation as well as near real time 

support of independent applicationthreads.

Generally, these different software needs require the support of multiple operating 

systems and require software driver and Board Support Packages (BSPs) to support 

the low-level hardware functions.

1.3.1 Device Driver Support

Standard Windows 10 video, chipset and network drivers used for testing during 

development are available by contacting your Abaco representative. Standard 

Drivers for Linux should be available from the release OS vendor. Drivers for other 

specific XVR19 functions are available by purchasing the applicable OS Software 

Support Package from Abaco Systems.

1.3.2 UEFI Infrastructure Support

XVR19 uses Aptio UEFI that includes all functions required by the processor core 

and chipset. This package also includes the onboard hardware initialization code 

that is executed following release from reset.

The UEFI also provides ROM code that supports remote booting from any of the 

Ethernet ports.

1.3.3 Target Operating Systems

The XVR19 hardware supports Windows, Linux, and VxWorks operating systems.

Please contact local sales and support services for the most current operating system 

version information.

NOTE

The XVR19 is shipped with Compatibility Support Module (CSM) disabled in the CMOS setup. This allows 

the unit to operate in a UEFI aware environment. Some operating systems may require special drive setup 

or parameters to use the UEFI mode. Contact your OS vendor for specifics needed for UEFI compatibility. If 

CSM Mode is needed for Legacy OS operation, it may be enabled in the advanced CMOS setup tab. See 

Section C.4.2 for CSM details.

1.4 Power Requirements

• +5V, +3.3V

• ±12V for mezzanine only

2 • Unpacking and Installation

This chapter describes the installation of the XVR19 VME Single Board Computer on 

a VME backplane and initial power‐on operations.

2.1 Unpacking Procedures

On receipt of the shipping container, check for any evidence of physical damage. All 

claims arising from shipping damage should be filed with the carrier and a complete 

report sent to Abaco Technical Support, see Technical Support Contact Information.

Electronic assemblies use devices that are sensitive to static discharge. Observe 

antistatic procedures when handling these boards. All products should be in an 

antistatic plastic bag or conductive foam for storage or shipment. Work at an 

approved antistatic workstation when unpacking boards.

2.2 Identifying Your Board

The board is identified by labels at strategic positions. These can be cross-checked 

against the Advice Note provided with your delivery.

Identification labels attached to the shipping box and the antistatic bag give identical 

information: product code, product description and equipment number. On the 

board within the antistatic bag, there is an identifying label attached to the PCB.

2.3 Equipment Grounding

To minimize electric shock hazard, connect the equipment chassis and 

rack/enclosure to an electrical ground. If AC power is supplied to the rack/enclosure, 

the power jack and mating plug of the power cable must meet International 

Electrotechnical Commission (IEC) safety standards.

  • Electric tricycle truck, agricultural tricycle, elderly vehicle, warehouse truck
  • GE 8042-CC-85 Carrier extension cable, 0.85m
  • GE 8086-FC-20 20 + 24 pin cables for 8619 (2m)
  • GE 8041-CC-35 Carrier extension cable, 0.35m
  • GE 8085-FC-10 20 + 24 pin cables for 8619 (1m)
  • GE 8034-CC-12 Intrinsically Safe Carrier Extension
  • GE 8082-FC-30 16-pin cable for 8618 (3m)
  • GE 8030-CE-RH Intrinsically Safe Carrier extender, right hand
  • GE 8080-FC-10 16-pin cable for 8618 (1m)
  • GE 8021-CE-LH Carrier extender, left hand
  • GE 8044-CC-20 Carrier extension cable, 2.0m
  • GE 8725-CA-RB Railbus isolator carrier with PFM
  • GE 8712-CA-NS Node services carrier, Profibus-DP LAN
  • GE 8724-CA-PS Intrinsically Safe module power supply carrier
  • GE 8711-CA-NS Node services carrier, screw terminal LAN
  • GE 8723-CA-RB Railbus isolator carrier
  • GE 8606-FT-RT Field terminal, RTD
  • GE 8620-FT-MT Field terminal assembly
  • GE 8604-FT-FU Field terminal, fused
  • GE 8617-FT-NI Field Terminal, non-incendive, for 16 ch DI
  • GE 8601-FT-NI Field terminal, non-incendive (Div 2)
  • GE 8215-DO-IS 4-channel Intrinsically
  • GE 8202-HO-IS 8-channel Intrinsically Safe Analog Output, 4-20 mA with Hart
  • GE 8206-TI-IS 8-channel Intrinsically Safe RTD input
  • GE 8201-HI-IS 8-channel Intrinsically Safe Analog Input, 4-20mA with Hart
  • GE 8117-DO-DC 8-channel DO, 2-60Vdc isolated, unpowered
  • GE 8810-HI-TX 8-Channel Safety AI, 4-20mA with HART
  • GE 8142-DO-DC 16-channel Digital Output
  • GE 8140-DI-AC 16-channel Digital Input, 115VAC isolated, sinking
  • GE 8112-DI-AC 8-channel DI, 115Vac non-isolated, module powered
  • GE 8139-SH-DC 126-channel Addressable Smoke and Heat
  • GE 8111-DI-AC 8-channel DI, 115Vac isolated, sinking
  • GE 8133-HI-TX 8-Channel Supervised AI with HART
  • GE 8110-DI-DC 8-channel DI, 24Vdc non-isolated, module powered
  • GE 8109-DI-DC 8-channel DI, 24Vdc isolated, sinking
  • GE 8129-IO-DC 8-channel Supervised Discrete I/O
  • GE 8106-TI-RT 4-channel RTD input
  • GE 8127-DI-SE 32-channel SOE module
  • GE 8105-TI-TC 4-channel THC/mV input
  • GE 8125-DI-DC 32-channel DI, non-isolated, module-powered
  • GE 8104-AO-IP 8-channel AO, 4-20mA
  • GE 8122-DI-DC 16-channel DI, 24Vdc isolated, sinking
  • GE 8103-AI-TX 8-channel AI, 4-20mA
  • GE 8121-DI-DC 16-channel DI, 24Vdc non-isolated
  • GE 8102-HO-IP 8-channel AO, with HART for 4-20mA
  • GE 8119-VI-05 8-channel Voltage Input, 1-5Vdc
  • GE 8101-HI-TX 8-channel AI, 4-20mA with HART
  • GE 8755-CA-NS EBIM carrier
  • GE 8522-EB-MT Ethernet Bus Interface
  • GE 8752-CA-NS Universal Node Services Carrier
  • GE 8515-BI-PN PROFINET Scanner Module
  • GE IC754VBI12CTD Touch Screen
  • GE IC754VGI10MTD Touch Screen
  • GE IC754VBI1OMTD Touch Screen
  • GE IC754VSL12CTD QuickPanel
  • GE IC754VBL12CTD QuickPanel
  • GE IC754CGL12CTD QuickPanel
  • GE IC754CBL12CTD QuickPanel
  • ABB TZIDC Digital Positioner
  • ABB NextMove ESB-2 motion controller
  • ABB Advant Controller 70
  • ABB Advant Controller 250
  • ABB ACS850-04 drive modules
  • ABB IRB 4600 Industrial Robot
  • ABB IRB 910SC SCARA
  • ABB Product specification IRB1200
  • ABB DCV 700 thyristor panels
  • ABB Advant Controller 160
  • ABB Serial Communications Module RS232
  • ABB PP886 Compact Product Suite hardware selector
  • ABB Panel 800 version 6
  • ABB Uvisor™ FAU810 – Flame Analysis Unit
  • ABB Switches Automatic Transfer Switches
  • ABB Dynamic braking / DC drive
  • ABB Automatic Transfer Switch OTM_C_21D
  • ABB Switches Change-over and transfer switches
  • ABB PGC2000 Series Process Gas Chromatograph
  • ABB PGC5000 Series gas chromatographs
  • ABB DBDID Process gas chromatographs
  • ABB Vapor Pressure (RVP) analyzers
  • ABB Distributed busbar protection REB500
  • ABB SYNCHROTACT® upgrade Keep your assets synchronized, safe and productive
  • ABB SYNCHROTACT® Datasheet Synchronizing devices and systems
  • ABB C310 Wall- / Pipe-mount universal process controller
  • ABB AP100 pH/Redox (ORP) cartridge sensors with water-wash option
  • ABB Title this is title and subtitle this is subtitle Power Factor Controller RVC Accurate control and monitoring of capacitor banks
  • ABB FOUNDATION Fieldbus Linking Device LD800HSE EX
  • ABB Remote Terminal Unit RTU560
  • ABB MEASUREMENT & ANALYTICS TEIP11
  • ABB MEASUREMENT & ANALYTICS Navigator 540
  • ABB For electromagnetic flowmeters FXE4000-DE43F
  • ABB COM610 Communication Gateway
  • ABB Symphony Plus S+ Control BRC410
  • ABB Symphony Plus SD Series PROFIBUS Interface: PDP800
  • ABB Symphony Plus SD Series HART I/O: HAI805 and HAO805
  • ABB Symphony Plus S+ Turbine: Auto Synchronizer Module AS800
  • ABB S900 I/O Application-Guide CI920S/CI920B replaced by CI920AS/CI920AB
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB IndustrialIT System 800xA S800 I/O System
  • ABB Advant® Master S100 I/O system
  • ABB Ability™ Symphony® Plus MR Series (Melody Rack)
  • ABB Data Sheet ControlIT Harmony Analog I/O
  • ABB Bailey* network90 Loop Interface/Bus Interface(LIM/BIM)
  • ABB Bridge Controller and Process Bus Adapter BRC-300 and PBA-200
  • ABB Kent Morrisey, Business Development Manager – Harmony Evolution NA Harmony Evolution Options For Process Industries Users
  • ABB Industrial'T System 800xA Harmony/INFI90 System
  • ABB Ability™ Symphony® Plus HR Series Control and I/O
  • ABB AC700F controller with direct S700 I/O
  • ABB ContransIthe family with Instruction Manual for Freelance 2000
  • ABB AC servo motors BSM Series
  • ABB BSD Series
  • ABB ControlMaster CM10 Universal process controller, 1/8 DIN
  • ABB PGC2000 Advance Training Course Synopsis
  • ABB PGC5000 Series gas chromatographs
  • ABB EasyLine EL3000 Series Continuous gas analyzers
  • ABB AO2000 Advance Optima Continuous gas analyzers
  • ABB Advant® Controller 450
  • ABB Advant® Controllers
  • ABB Ability™ System 800xA
  • ABB Advant® Master S100 I/O system
  • ABB SYNCHROTACT®5 Operating Instructions
  • ABB Web Tension Systems with Tension Electronics PFEA111
  • ABB Pressductor Pillowblock Load Cells Vertical Measuring PFCL201
  • ABB Force Measurement Products Cold rolling and processing of steel
  • ABB DCS800 Drives
  • ABB MNS iS motor control center
  • ABB Condition MonitoringMService