K-WANG
Xycom 10330-00800 board
Product positioning and technical specifications
Core functions:
32 channel design: includes 32 digital inputs (DI) and 32 digital outputs (DO), supports optoelectronic isolation, and can withstand electrical interference in industrial environments.
VME bus interface: compatible with the VME standard, suitable for industrial control systems that require high-speed data transmission (such as aerospace, semiconductor manufacturing).
Modular design: Supports hot plugging, easy maintenance and expansion, and can monitor channel status in real-time through LED indicator lights.
Technical parameters:
Working voltage: usually 24VDC (to be confirmed according to specific model).
Isolation characteristics: Optoelectronic isolation is used between the input/output channel and the VME bus, with an isolation voltage of ≥ 2500VAC.
Response time: Typical value ≤ 1ms, meeting real-time control requirements.
Verification and Risk Warning:
Product status: Suppliers are required to provide serial numbers or test reports to avoid purchasing non original or damaged equipment.
Compatibility verification: If used for old systems, the VME bus slot specifications (such as 6U size) and communication protocol (such as VME64x) need to be confirmed.
Compatibility and alternative solutions
System compatibility:
VME bus matching: It is necessary to ensure that the target system's VME backplane supports 6U size modules and provides sufficient power supply (such as+5V,+12V).
Protocol support: Some VME systems require additional configuration of drivers or firmware. It is recommended to request technical documentation from the supplier in advance.
Recommended alternative solutions:
Pro Face alternative model: Pro Face does not directly provide a substitute product for 10330-00800. AGP 3xxx series industrial PCs with extended I/O modules (such as ADAM-4000 series) can be considered to achieve similar functions
Third party VME modules, such as Mercury Systems' MVME 162-110 (32 channel DIO), are compatible with the VME64x protocol and support long-term spare parts supply.
Repair and maintenance recommendations
Fault diagnosis:
LED indicator light: Determine channel faults through the status lights on the module (such as a constant red light indicating a short circuit).
Self diagnostic function: Some VME systems support remote diagnosis and can read module error codes through software.
Compatibility testing:
Require suppliers to provide test reports or prototypes to verify the stability of the module in the target system. If software migration is involved, you can consult Pro Face for protocol conversion tools.