AB Allen-Bradley's 1734 POINT I/O Series Products

From: | Author:Wang | Time :2025-04-16 | 275 visit: | Share:

AB Allen-Bradley's 1734 POINT I/O Series Products

Product Overview: The 1734 POINT I/O Series is a key part of Rockwell Automation's integrated architecture, offering modularity, diagnostics, and configurability for a wide range of automation systems. It offers a wide range of modules with point densities from 1 to 8 points and supports a variety of communication protocols for flexible system configurations.

Selection steps: First, select the communication interface module according to the application requirements, such as EtherNet/IP, ControlNet, DeviceNet, PROFIBUS DP, etc.; then select the appropriate I/O module according to the required number of points and functions, including digital, analogue, special-purpose modules, etc.; then select the wiring chassis components, such as monolithic or removable terminal block type; and then Then select power supply components, such as communication adapter built-in power supply, extended power supply and field power distributor; finally, determine the number of DIN rails according to the number of modules and physical requirements.


Communication Interface Modules: The NetLinx open network architecture features a variety of networks, each suitable for different scenarios: EtherNet/IP networks for plant management and other scenarios, with the 1734-AENT/1734-AENTR adapters supporting direct and rack-optimised connectivity; ControlNet networks for high-speed control, with the 1734-ACNR adapter having a specific number of connections and memory requirements; and the 1734-ACNR adapter having a specific number of connections and memory requirements. 


The ControlNet network meets the demands of high-speed control, and the 1734-ACNR adapter has specific connection and memory requirements; the DeviceNet network is used for the connection of the underlying devices and is available in different interfaces such as the 1734-ADN, 1734-ADNX, and 1734-PDN; and the PROFIBUS DP network connects to the existing bus, and the 1734-APB adapter has the corresponding technical specifications. The communication adapters have similar environmental specifications, operate in a temperature range of - 20 °C to 55 °C and are resistant to shock, vibration and electromagnetic interference.

I/O modules


Digital I/O modules: AC and DC input/output modules and contact modules with various voltage interfaces, some modules have diagnostic functions and electronic fuses to meet the requirements of different application scenarios, and each module has corresponding electrical parameters and environmental technical parameters.


Analogue and Temperature I/O Modules: The analogue input modules support a wide range of signals and high resolution, the temperature input modules can detect a variety of temperature-related states, the analogue output modules have high accuracy and fast response characteristics, these modules also have channel-level diagnostics, alarms and other functions.


Dedicated I/O modules: 1734-232ASC and 1734-485ASC provide communication interfaces for serial connections, 1734-SSI is used to acquire absolute encoder data, 1734-ARM is used to reserve addresses, 1734-CTM and 1734-VTM extend terminal functionality, and the counter module has multiple counting modes.

Safety I/O modules: e.g. 1734-IB8S, 1734-IE4S, 1734-OB8S for safety control systems, meeting specific safety standards, with detailed electrical parameters and description of safety functions.


Terminal block assemblies and power supply units: Terminal block assemblies are available in a variety of types, with field wiring terminals, some of which are pre-assembled for easy installation and maintenance. Power supply units include the communication adapter's built-in power supply, extended power supplies (e.g. 1734-EP24DC, 1734-EPAC) and field power distributors (1734-FPD), each with different functions and technical parameters.

Installation requirements: The modules should be mounted on the right side of the power supply, depending on the power supply backplane current and module requirements. The system can be mounted horizontally or vertically on specific DIN rails, with good grounding to prevent EMI, and with space above the 1734-IB8S, 1734-OB8S and 1734-IE4S modules.


System installation requirements

Installation position and layout: Modules should be installed on the right side of the power supply, and the layout should be planned according to the backplane current of the power supply and the current demand of the modules. Systems with different communication interfaces have limitations on the maximum number of I/O modules and connections, e.g. 1734-PDN for DeviceNet network, maximum 17 modules without extended power supply.


DIN rail selection and fixing: Use steel 35 x 75.5 mm DIN rails (Catalogue Nos. 199-DR1; 46277-3; EN 50022), which need to be fixed to a common conductive surface approximately every 200 mm (7.87 in) to ensure good immunity to electromagnetic interference (EMI).


Module installation sequence and orientation: Install the communication interface modules, such as 1734-ADN, 1734-PDN, etc., first, then install the wiring chassis, and finally install the I/O modules. When installing the modules, make sure that they are orientated correctly and that the locking screws of the wiring base are in a horizontal position. When installing some modules (1734-IB8S, 1734-OB8S, and 1734-IE4S), make sure that there is 2 in. (approx. 50.8mm) of clearance above the POINT rail.


Wiring and Grounding: When wiring, pay attention to the wiring requirements of different modules and use the appropriate terminal block assembly. For example, the 1734-TB series terminal blocks have different wiring and torque requirements. The system should be well grounded to ensure normal operation and anti-interference capability.


Installation environment: The equipment is suitable for use in pollution class 2 industrial environments, overvoltage category II applications, with operating temperatures ranging from - 20°C to 55°C, non-operating temperatures ranging from - 40°C to 85°C, and relative humidity of 5% - 95% without condensation.


  • ABB 216AB61 Industrial Control Module for Automation Systems
  • ABB 5SHX1060H0003 High Power Thyristor Module for Industrial Power Control
  • ABB 07KT97H3 PLC Central Processing Unit for Industrial Automation
  • ABB 3BHB005171R0101 Power Semiconductor Module for Industrial Power Systems
  • KEBA E-SP-CCEC/A/22 - Keyboard Panel
  • KEBA ERHL33 - Module
  • KEBA K-FTC-AN/B - Control Panel Board
  • KEBA DO321 1914D-0 - Digital Output Module
  • KEBA T70Q - Teach Pendant
  • KEBA BL272/A / BL272/B - Bus Coupling Module
  • KEBA T70R - Teach Pendant
  • KEBA PRONET-E-20A-K - Servo Drive
  • KEBA T55-RA0-AU0-LK - Mobile HMI KeTop
  • KEBA DO-272/A - Digital Output Module
  • KEBA PS240/A - Power Supply Module
  • KEBA 2134-00393 - Module Code
  • KEBA E-10-ANALOG-SU - Analog Card
  • KEBA 1904D-0 / D1458E - E-10 Analog Card
  • KEBA FM265A - Function Module
  • KEBA CR17910086 - Controller Board
  • KEBA C5G-TP5WC2 - Robot Teach Pendant
  • KEBA PD242A - Power Supply Module
  • KEBA DI-325 - Digital Input Card
  • KEBA C2-TM-240/A - Digital Input Module
  • KEBA D1547C - I/O Bus Coupling Board
  • KEBA CR-092 - Interface Module
  • KEBA 3HAC023195-003 - IRC5 Teach Pendant Cable
  • KEBA KETOP-T150-MA0 - Mobile HMI
  • KEBA KC-P30-EC24011 - Control Module
  • KEBA 1770B-1 - E-8-THERMO Card
  • KEBA T20T-T00-AR0-CE6 - KeTop Terminal
  • KEBA D1633C-1 - CPU Card
  • KEBA HT401-232-8/0 - Teach Pendant
  • KEBA AO-570 - Analog Output Module
  • KEBA T10-mAb-DMV - Handheld Terminal
  • KEBA C70-rqa-AK0-Le - KeTop Teach Pendant
  • KEBA 1918F-0 - Digital Output Board
  • KEBA T10-mAa-DMV - Handheld Terminal
  • KEBA HT2-SCHLUSSELS - Key Switch for HT2
  • KEBA T100-003-CES - HMI Terminal
  • KEBA GVME610IO - I/O Module
  • KEBA HT501-231 - Teach Pendant
  • KEBA E-CG-CONTROL - Graphic Control Card
  • KEBA D1420F - F-SIC-1 Circuit Board
  • KEBA E-ANA-SUB2 - Analog Sub-module
  • KEBA HT401-222-4 - Teach Pendant
  • KEBA II030 - Input Module
  • KEBA T155-M10-AN0-W - KeTop Mobile HMI
  • KEBA CP088-B - Processor Module
  • KEBA HT40123280 - Operating Terminal
  • KEBA HT4222 - Handheld Terminal
  • KEBA H24025369 - Replacement Part
  • KEBA H24024891 - Replacement Part
  • KEBA SR161 - Analog Input Card
  • KEBA 1762A - E-CRT/EL Circuit Board
  • KEBA T50-011-CES-CE5 - Operator Terminal
  • KEBA E-CON-ELD/B/15 - Control Panel
  • KEBA E-8-THERMO - Thermocouple Card
  • KEBA 330/A-1211-20 - Axis Module
  • KEBA T55-maw-AU0-CE6 - Mobile HMI
  • KEBA C150-110-AK0-N - KeTop HMI
  • KEBA HT4-20656 / HT4-221 - Handheld Terminal
  • KEBA 18658-1 - Analog Board
  • KEBA LM64P89 - LCD Display Screen
  • KEBA E-CPU-88-A - CPU Board
  • KEBA D-CE/59718/15 - Control Board
  • KEBA KC-P30-ES2400E2-E00 - Control Module
  • KEBA 3HAC12929-1 - Teach Pendant SX TPU
  • KEBA E-CON-CC100/A - Control Panel Engel
  • KEBA T200-M01-P20-WES7 - Panel PC Windows Embedded
  • KEBA KC-P30-ES2400B2-M0R - KeControl C3 Module
  • KEBA E8ANALOGC - Analog Card
  • KEBA E-CPU-88-B - CPU Board
  • KEBA T55-raw-AU0-CE6 - Mobile HMI
  • KEBA D1633C - CPU Board
  • KEBA T55-MAW-Au0-CE6 - Mobile HMI
  • KEBA 3HAC11266-4 - Teach Pendant Cable
  • KEBA T20e-m00-Br0-C - Handheld Terminal
  • KEBA E-3-ACU-INC - Controller Board
  • KEBA E-PS-24V - Power Supply Module 24V
  • KEBA C55-2aw-1U0-R - Control Unit
  • KEBA T70-qqu-Aa0-LK - KeTop Teach Pendant
  • KEBA PS244 - Power Supply Module
  • KEBA ECPU186B - CPU Circuit Board
  • KEBA E-8-ANALOG/C - Analog Input Card Engel
  • KEBA AT-4041 - KeControl C3 Controller
  • KEBA T50-ADP - Adapter Module
  • KEBA CP088/D - Control Processor Module
  • KEBA CU312 - Central Unit Module
  • KEBA K2-400 SC440/A - Communication Module
  • KEBA CU212 - Power Supply Module
  • KEBA T20T-T00-AR0-C - KeTop Handheld Terminal
  • KEBA HT4014X20B21572 - Teach Pendant
  • KEBA HT4010V4X201K4 - Operating Terminal
  • KEBA HT401/NC-4X20/20844 - Handheld Terminal
  • KEBA RS-091 / RS091A - Remote Station Module
  • KEBA E8THERMOA - Thermocouple Input Card
  • KEBA TI-570 - Temperature Input Module
  • KEBA C35E 10m/79421/02 - KeTop Teach Pendant
  • KEBA T40-001/58599/06 - Teach Pendant
  • KEBA CR17910087 C5G-GTP5 - Controller Board
  • KEBA T20E-R00-AR0-C - Handheld Terminal
  • KEBA 3HAC023195-001 /02 - Teach Pendant Unit
  • KEBA AR281 - Analog Input Module Engel
  • KEBA D3-DA330/A-0611-20 - D3 Axis Module
  • KEBA CU313 / C-SICU313KEB - Control Unit
  • KEBA k2-700 - Kemro Control System
  • KEBA CU211 - Central Unit Power Supply Module
  • KEBA C5G-TP5WC - Robot Teach Pendant
  • KEBA C100D-CE - Control Panel
  • KEBA D3-DR361/D-6341-30 - D3 Drive Module
  • KEBA D3-DP/A-1000-0 - D3 Supply Module
  • KEBA SXTPU-21664 - Teach Pendant Unit
  • KEBA T70-rqa-AK0-LK - KeTop Touch Screen Glass Panel
  • KEBA C10-1aa-abb - Control Terminal
  • KEBA T50-T41-CPU - CPU Module
  • KEBA 3HAC023195-001 - IRC5 Sx TPU 2 Teach Pendant Controller
  • KEBA D3-DA 330/A-1211-00 - D3 Axis Module
  • KEBA K2-200 250/X (71580) - Processor Module
  • KEBA O70-bra-A0a-F - Operator Panel
  • Creative Duster Vinyl Brush - Record Stylus Cleaner Brush
  • KEBA 3HAC12929-1/04 - Touch Panel Touchscreen Glass Replacement
  • KEBA OP350/Y-1016 - Keyboard Membrane Protective Film K2-200
  • KEBA DO 321/B - Digital Output Card
  • KEBA DI 325/B - Digital Input Module
  • KEBA E-16-DIGOUT-PLUS (D1456E-2) - Digital Output Board
  • KEBA AI 240/A (068370) - Kemro K2-200 Analog Input Module
  • KEBA TM 220/A (066676) - Kemro K2-200 Module