AB 1746-C7, 1746-C9, 1746-C16 SLC 500™ Programmable Controller Rack Interconnect Cables

From: | Author:Wang | Time :2025-04-16 | 242 visit: | 🔊 Click to read aloud ❚❚ | Share:

AB  1746-C7, 1746-C9, 1746-C16 SLC 500™ Programmable Controller Rack Interconnect Cables

Cable Overview: The SLC 500™ Programmable Controller Rack Interconnect Cables are available in three models, 1746-C7, 1746-C9, and 1746-C16. 1746-C7 is 152.44mm (6 inches) in length, and is used in connection scenarios where rack spacing is close; 1746-C9 is 914.44mm (36 inches) in length, and is designed for medium-distance rack connections; and 1746-C16 is 1270.0mm (50 inches) in length, and is commonly used in situations where rack spacing is large. (36 inches) for medium-distance rack connections; and 1746-C16 is 1270.0mm (50 inches) in length, which is often used in situations where racks are spaced farther apart. These cables are designed to connect individual racks of SLC 500™ programmable controllers and are a key component in building a complete control system that ensures stable and efficient data communication between processors.


Installation Considerations

Installation order: In multiple rack configurations, the rack interconnect cables need to be installed before the power supply.

Correct Installation: The cable is designed with a ‘key’ that plugs into the left socket end of the ‘key’ on the outside of the connector, and the other end of the ‘key’ on the inside of the connector, and so on to ensure correct installation.

Fixing requirements: It is important to ensure that the cable is properly fixed and protected from shock and vibration. To remove the cable, move the tabs on the socket outwards and the connector will pop out.

Expansion cable installation: The expansion cable must be routed from the right end of the rack with the CPU; incorrect installation may result in system failure.

Specific Cable Usage Scenarios: The 1746-C16 cable should be used when connecting two 1746-A13 racks, one above the other, with 1746-P4 power supplies.

Restrictions on Use: Cables other than those specified in the documentation are strictly prohibited, as longer cables may compromise the integrity of inter-processor data communications and cause unsafe operation.


Key Questions

Why can't I use non-specified cables to connect the rack?

Answer: Non-specified cables, especially longer cables, may compromise the integrity of inter-processor data communications, which in turn may lead to unsafe operation and threaten the normal operation and safety of the system.

Under what specific circumstances are 1746-C16 cables used?

Answer: The 1746-C16 cable must be used when there is a need to connect two 1746-A13 racks, one above the other, and both racks are equipped with 1746-P4 power supplies.

When installing rack interconnect cables, how do I make sure they are installed correctly?

Answer: First, install them in order before the power supplies in multiple rack configurations. Second, pay attention to the ‘key’ of the cable. Inserting the cable with the ‘key’ on the outside of the connector at one end of the left socket and the ‘key’ on the inside of the connector at the other end ensures that the cable is correctly installed. correct installation.


Performance Differences between SLC 500™ Programmable Controller Rack Interconnect Cable Models

The difference in cable length directly affects the connection distance: 1746 - C7 cable length is 152.44mm (6 inches), 1746 - C9 cable length reaches 914.44mm (36 inches), 1746 - C16 cable length is 1270.0mm (50 inches). The shorter 1746-C7 is ideal for closer rack spacing and reduces signal delay and loss to ensure efficient data communication, while the 1746-C9 and 1746-C16 provide flexible cabling options for industrial control systems of different sizes, as they are designed to meet the connectivity needs of widely spaced racks. In small automated production lines, where equipment is compact and racks are close together, 1746 - C7 cables work well for rack connectivity, while in distributed control systems in large factories, where racks are spread out over a wide area, longer cables such as 1746 - C16 cables may be needed to connect racks in different areas.


The different lengths of cables are suitable for different scenarios: 1746 - C7 is suitable for systems that require high stability of signal transmission, relatively fixed rack locations and short distances, such as control systems for small precision processing equipment, short distance connections can minimise signal interference and ensure precise control of the equipment. 1746 - C9 is suitable for medium-sized industrial control systems, which can satisfy the need for a certain distance connection, and can better balance the signal and the signal. At the same time, it can better balance the signal transmission quality and cost. On the production floor of medium-sized factories with spaced equipment layouts, 1746 - C9 cables can be used for both rack connections and reliable data communication. 1746 - C16 is mainly used in specific scenarios where two 1746 - A13 racks, one above the other, are connected with 1746 - P4 power supplies, and its length and performance ensures stable data transmission between such large rack combinations. Its length and performance ensure stable data transfer between such large rack combinations. In the control system of a large power plant, multiple 1746 - A13 racks may be used, and the 1746 - C16 cables will be able to fulfil the connection needs between them.


Potential impact of cable length on data communications: The use of non-specified cable lengths, especially excessive lengths, may affect the integrity of data communications between processors. Although the documentation does not specify the specific differences in data transfer performance between the three cables, in principle, longer cables may lead to problems such as signal attenuation and increased latency. 1746 - C16 cables are relatively long and the signals may be weakened to a certain extent during data transfer, compared to 1746 - C7, which, due to its shorter length, has a lower risk of signal attenuation and latency. In industrial control scenarios where real-time data transmission is critical, such as the automation of high-speed production lines, 1746 - C7 cables may be more suitable, while in scenarios where real-time data transmission is less critical and the connection distance is farther away, 1746 - C16 cables can function normally with acceptable signal attenuation and delay.



  • LTI Drives CDF30.002.C0.7 Compact Servo Controller 08685963 DC 24V Industrial Module
  • LUST LTI Drives CDB32.008.W2.4.BR.PC1 Servo Drive Industrial Motion System
  • LUST LTI Drives CDB34.003.C2.4.PC1.H15 Servo Motor Driver Industrial Control Unit
  • LUST LTI Drives CDA32.004.C1.4.H08.B0 Servo Drive Mat. 3084456 Industrial Control
  • LUST LTI Drives CDE34.005.W2.2 Industrial Servo Drive Motion Control Unit
  • LUST LTI Drives CDA34.006.W3.0 Servo Drive Software V3.70-04 Industrial Controller
  • LTI Drives CDB32.004.C2.4.SH Servo Drive Compact Motion Controller
  • Woodward 9905-373 - Digital Synchronizer And Load Controller
  • WOODWARD MAGNETIC PICKUPS - Sensor
  • WOODWARD GCP-30 - Steuertafel for Industrial Regulator Genset Control Package
  • WOODWARD GOVERNOR 9907-1183 REV A - 505 ENHANCED TURBINE CONTROL
  • WOODWARD 9907-173 REV B - Module Load Sharing 120 Volt
  • WOODWARD 9907-014 - 2301A controller
  • Woodward 9905-029 - SPM-A Synchronizer Module Rev C
  • WOODWARD 8440-1799 EASYGEN-350 REV B - Genset Controller
  • WOODWARD 5466-258 REV M - SIMPLEX DISCRETE I/O MODULE
  • Woodward 8440-1884 C - Controller Easygen 2500-5
  • Woodward 8441-1153 - Monitoring Unit 250VAC
  • WOODWARD 8406-120 REV G - EGCP-2 DIGITAL CONTROL
  • Woodward 8273-584 - Atlas-ii Digital Control
  • Woodward 8272-582 - APM Motor Control 8272582
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8272-517 - Pm Motor Control
  • WOODWARD 9905-797 REV.B - DIGITAL SYNCHRONIZER AND LOAD CONTROL DSLC-D
  • WOODWARD 8272-582 - APM MOTOR CONTROL
  • Woodward Seg FP2-8-24 - Emergency Power Telecommunications Module NP2
  • WOODWARD 2001-12E2U1B1S1A - Fuel Shut Off Valve Stop Solenoid Valve 2000-4505
  • Woodward 8440-1884 K - Genset Controller Easygen-2500-5
  • Woodward 9905-760 - Linknet Termination Module
  • Woodward 8404-009 - Proact Digital Plus Front Panel Rev. H
  • Woodward 8271-651 - Digital Speed Reference
  • Woodward 3077-474C - 8605895 5501-031 D Circuit Module
  • WOODWARD 5466-257 REV.-C - NETCON 5000 MODEL REMOTE TRANSCEIVER I/O MODULE
  • Woodward 8273-101 Rev: A - 2301D Digital Load Sharing and Speed Control
  • WOODWARD 8272-799 - 2301A SPEED CONTROL WITH REMOTE REFERENCE REV:C
  • Woodward 8272-517 - PM Motor Control
  • Woodward 8290-048 8290048 Rev. F - Generator Load Sensor
  • woodward 8273-1012 rev c - 2301e Load Sharing and Speed Control
  • WOODWARD 9905-797 - DIGITAL SYNCHRONIZER AND LOAD CONTROL FOR 3 PHASE GENERATORS
  • WOODWARD 8280-3014 - 723 PLUS DIGITAL CONTROL REV NEW
  • WOODWARD 8440-1884 REV G - GENSET CONTROLLER EASYGEN-2500-5/P1
  • Woodward 8272-683 K - Digital Reference
  • WOODWARD 9907-014 - SPEED CONTROL 2301A REV H
  • Woodward Type UG-8 P/N 037260 - Governor R.P.M 1075-1650 Motor KM58-20
  • WOODWARD 9905-970 - LINKNET 6 CHANNEL 100 OHM RTD Rev:J
  • Woodward 9907-1183 Rev C - Steam Turbine Digital SCREEN 505E Turbine Control
  • Woodward 8440-1614 - GCP-30 Genset Control Package, Rev: F, Type 1, E231544
  • Woodward DC11006-304-024 - ACTUOTOR DYNA ACTUATOR - BARBER-COLMAN
  • Woodward 9905-971 - LINKNET 6 CHANNEL 100 OHM RTD Rev:K
  • Woodward DYNK-10249 - Actuator Controller Kit - DYNA 2000
  • Woodward LR21035 - MFR1 MULTI FUNCTION RELAY REV F
  • Woodward 8440-1831 - EASYGEN 3200-5 P/N: REV. G Gererator Controller
  • Woodward 8272-516 - PM MOTOR CONTROL REV J
  • Woodward 8440-2080 - EASYGEN 2000 genset controller EASYGEN-2300-5/P1
  • Woodward 505DE - Digital Control System
  • Woodward 701 - Digital Speed Control 18-40 VDC 4-20 MA
  • Woodward 8440-1799 - EASYGEN-350 REV B
  • Woodward 8272-582 - Apm Motor Control 100-220v AC/DC
  • Woodward 5501-031 D - 3077-474C 8605895 Circuit Module
  • Woodward XD1-T - XD1T55SAT TRANSFORMER DIFFERENTIAL PROTECTION RELAY
  • Woodward 8272-517 - PM Motor Control 220vac
  • Woodward 8934-658 - Repair Kit UG8D Governor
  • Woodward 5437 18 - module netcon derivative analog rev.A
  • Woodward 8272-171 A - Pm Motor Control
  • Woodward MRN3-1/2 - SEG mains uncoupling relay MRN314D mains decoupling relay
  • Woodward 9905-373 - Digital Synchronizer and Load Control 18-40 VDC Rev P
  • Woodward 5431-640 C - Dual Dynamics 1000 Series Speed Control Module
  • Woodward 5501-031 D - 3077-474C 8605895 Circuit Module
  • Woodward 9907-247 - 828 DIGITAL CONTROL
  • Woodward 8440-1855-G - EASYGEN-2200-5 /P1 12/24VDC GENSET CONTROLLER
  • Woodward NC3-2-8 (NO) - GENERATOR CONTROLLER
  • Woodward 8271-467 K - 2301 LOAD SHARING AND SPEED CONTROL PART NO:
  • Woodward 8440-2177 A - SPM-D2-10 Digital Synchronising Controller
  • Woodward LXMG1614E-14-11 - CCFL and UV Lamps Inverter Module
  • Woodward 8270-990 - signal converter
  • Woodward 9905-068 - LOW VOLTAGE 2301A LOAD SHARING & SPEED CONTOL P/N:
  • Woodward 8901-051 - BOOSTER SERVOMOTOR, SINGLE CYLINDER, 2:1
  • Woodward 8444-1024 D - MWS4-55M CONTROL MODULE UNIT
  • Woodward 5448-914 - GCP-20 Genset Control GCP-20 REV D P/n:
  • Danfoss BHA-1 018-1942 - Hydraulic Actuator
  • Woodward 9905-001 L - SPM-A SYNCHRONIZER
  • Woodward 5464-850 - Module
  • Woodward 5501-371 - Micronet Simplex Mpu Aio Rev C
  • Woodward 8272-132 B - POWER SENSOR
  • Woodward 9907-028 - SPM-A Synchronizer
  • Woodward SA-3678-AM-2 - Overspeed Electric Governor, Model ESSE2-AM
  • Woodward E8250-502 - GOVERNOR ACTUATOR
  • Woodward 8440-1884 J - Controller EASYGEN-2500-5
  • Woodward 5441-693 - DIGITAL I/O MODULE -MISSING PART
  • Woodward SA-4450 - Speed Controller APECS 3100 For Magnetic Pickup
  • Woodward 9903-466 - 701 DIGITAL SPEED CONTROL REV G
  • Woodward 1765-843 - Governor Speed Adjusting Motor P/N Type: SMM40 220V AC 50/60Hz
  • Woodward 9905-760 - Linknet Termination Module
  • Woodward 9907-247 - 828 DIGITAL CONTROL UNIT REV K
  • Woodward 5484-721 - motor
  • Woodward 8440-1734 - MFR-2 Rev.A Multi Function Relay MFR-2
  • Woodward CSC3SUWA - Controller
  • Woodward 8440-1667 - REV B SPM-D1010B/XN
  • Woodward 8406-120 - egcp-2 digital control
  • Woodward DPG-2201-002 - DIGITAL CONTROLLER REV D
  • Woodward 8272-516 - Pm Engine Control Rev J
  • Woodward 8440-1831 - EASYGEN 3200-5 P/N: REV. K - WITHOUT ACCESSORIES
  • Woodward 8273-101 - LOAD SHARING & SPEED CONTROL
  • Woodward 8440-1855-G - EASYGEN-2200-5 /P1 12/24VDC GENSET CONTROLLER
  • Woodward 9907-247 - 828 DIGITAL CONTROL UNIT REV K
  • Woodward LR21035 - MFR1 MULTI FUNCTION RELAY REV J
  • Woodward 8404-009 - PROACT DIGITAL PLUS FRONT PANEL REV J
  • Woodward 9905-204 - Rev N SPM-A synchronizer
  • Woodward 8521-367 - UG-8 P/N r R.P.M 750-1280 Governor / UG8
  • Woodward 9907-175 - Load Sharing Module Rev. B
  • Woodward 5464-645 - DRIVER MODULE REV A 2C ACT DRIVE
  • Woodward 8404-009 - PROACT DIGITAL PLUS FRONT PANEL REV J
  • Woodward 9907-175 - Load Sharing Module Rev. B
  • Woodward 8406-102 - Rev A EGCP-2 Digital Control Engine Generator 8406102
  • Woodward EASYGEN-2500-5 - Controller Genset
  • Woodward 8440-2082 - Controller
  • Woodward 8272-516 - PM MOTOR CONTROL REV J
  • Woodward 9905-373 - Digital Synchronizer and Load Control 18-40 VDC Rev P
  • Woodward 5501-429 - Actuator Controller 25mA 2 Channel , (UPP)
  • Woodward 8440-1869 - SPM-D10 Synchronizing System Control-SPM-D10B/PSY4-F-D
  • Woodward 9907-175 - Load Sharing Module Rev. A
  • Woodward 8200-224 - Servo Position Controller
  • Woodward 9906-619 - 723 PLUS DIGITAL CONTROL ( 8280-604 )
  • Woodward 8440-1519 - EASYGEN PART NO: REV: 4
  • Woodward 5501-371 - REV C MODULE- MICRONET SIMPLEX MPU & AIO FTM
  • Woodward EASYGEN-3200-5/P1 - Generator Controller Module Rev F
  • Woodward 8440-1884K - GENERATOR CONTROLLER EASYGEN-2500-5 REV,K
  • Woodward 5466-353 - REV C NETCON MAIN CHASSIS TRANSCEIVER