AB 1747 - AENTR SLC 500 EtherNet/IP Adapter

From: | Author:Wang | Time :2025-04-16 | 357 visit: | 🔊 Click to read aloud ❚❚ | Share:

AB 1747 - AENTR SLC 500 EtherNet/IP Adapter

Product Overview: The 1747 - AENTR adapter is used to connect CompactLogix and ControlLogix processors to SLC I/O modules, facilitating the migration of existing SLC control systems to Logix-based systems. It acts as a gateway, a CIP server on the Ethernet port and an SLC host on the 1746 backplane, supports a wide range of I/O modules, uses the CIP protocol for data transfer, and supports direct connections only.


Installation Guide: The Network Address switch is set to 999 by default and DHCP is enabled, the IP address can be set by the switch, DHCP server or non-volatile memory. Setting the switch to 888 restores the factory default settings, and specific settings enable or disable the web server. The adapter requires a 5V DC power supply, draws 470mA, and is powered by the SLC power backplane. To install, remove the I/O chassis power supply, install it in the left chassis slot (slot 0), and connect it to an Ethernet/IP network via an RJ-45 connector using specific wiring standards.


Configuration: The IP address, subnet mask, and optional gateway address should be configured prior to use, either through the Rockwell Automation BootP/DHCP utility, a third-party DHCP server, or a network address rotary switch. In the RSLogix 5000 or Logix Designer application, set up the hardware, create a sample application, add local EtherNet/IP bridges, adapters, and I/O modules to the I/O configuration, configure the parameters, and then download the application to the controller with customisable settings and online monitoring.


Operational Information: Most 1746 and 1747 discrete, analogue and special modules are compatible with this adapter, some modules such as 1746 - HSRV are not supported. The adapter uses a specific embedded switching toolkit that supports a specific number of connections and communicates on a polling basis. Module connections are available as Exclusive Owner, Input Only, Listen Only, and so on. The outputs can be configured for different operating states in fault and idle modes.


Troubleshooting and Maintenance: The module has a variety of status indicators, including the module status indicator, 4-character dot matrix display, Link 1 and Link 2 status indicators, etc. The different statuses of these indicators can be used to determine the operating conditions of the device and the cause of the failure. The adapter has detailed specifications, including Ethernet communication, general specifications, environmental specifications, etc., and has also obtained a number of certifications. Internal and network diagnostics are available via the adapter's web dialogue box, which includes pages for diagnostic overview, network settings, Ethernet statistics, and more. The RSLinx Ethernet communication driver needs to be configured for network communication with the adapter.


Functional characteristics

System connectivity and migration capabilities: The 1747 - AENTR adapter is designed to enable CompactLogix and ControlLogix processor control of SLC I/O modules, and serves as an important bridge for migrating existing SLC control systems to Logix-based systems. The adapter is a direct replacement for SLC controllers in the 1746 rack in legacy SLC control systems when upgrading to the Logix architecture, as well as a replacement for the 1747-ASB module or ControlNet adapters 1747-ACN15 and 1747-ACNR15 in remote SLC racks. It acts as a gateway between the SLC backplane and EtherNet/IP, enabling systems of different architectures to work together, protecting the user's investment in the legacy SLC system while enabling system upgrades and expansion.


Communication Protocols and Data Transfer Functions: The adapter uses the Common Industrial Protocol (CIP), the application layer protocol for EtherNet/IP. the CIP protocol is based on messaging and uses relative paths to send messages from the production device to the consumer device, which has many advantages. It simplifies the maintenance and module replacement process by eliminating the need to configure a routing table in the bridge module, and gives the user full control over the routing of each message, making it easy to select alternative paths for the same end device. 


The CIP producer-consumer model replaces the traditional source and destination (master-slave) model for data transfer. In a traditional I/O system, the controller polls the input modules for status, whereas in a CIP system, the input modules actively send data, either periodically or at a cyclic rate (multicast or unicast), and the controller receives the data as a consumer of the data. This model effectively reduces network traffic and increases transmission speeds. The adapter only supports a direct connection, which is a real-time data transfer between the Logix controller and the 1746/1747 I/O modules via the 1747 - AENTR adapter. The direct I/O connection specifies the cyclic rate through the Request Packet Interval (RPI) during configuration, ensuring timely and stable data transfer.


Hardware and software compatibility: On the hardware side, the 1747-AENTR adapter is compatible with a wide range of devices. It connects to the analogue, digital and special I/O modules of the 1746 and 1747 series, supporting a wide range of module types. In terms of analogue inputs and outputs, it can work with modules such as 1746-NI4 and 1746-NO4I for accurate acquisition and control of analogue signals. In terms of digital modules, it can be connected to a wide range of digital inputs and outputs, such as 1746-IA8 and 1746-OB8, to meet different digital control needs. 


In terms of software, it is compatible with specific versions of firmware, controller software and related programming software. The 1747 - AENTR requires firmware version 1.001 or higher, Logix controller version v20 or higher, RSLogix 5000 or Logix Designer software version v20 or higher, and RSLinx software version v2.59 or higher. Working together, these software packages provide a complete control and programming environment for configuring, programming, and monitoring the adapter and associated devices.


Diagnostic and Status Indicators: The 1747-AENTR adapter is equipped with a variety of diagnostic indicators that provide real-time feedback on the operating status of the device. The Module Status Indicator shows the basic status of the device, such as whether it is powered on or not, and whether it is running normally. The 4-character dot-matrix display, used in conjunction with the Module Status Indicator, not only shows the IP address of the module, but also reports on normal operation and error conditions. 


When the system starts up, the display will show the relevant startup information; if there is a fault, it will show the specific error code or prompt message to help users quickly locate the problem.Link 1 and Link 2 status indicators are used to indicate the port speed and activity of Ethernet ports 1 and 2, through the different colours and flashing status of the indicators, users can intuitively understand the status of the network connection, such as whether the connection is established, the connection speed is 10.0%, and the connection speed is 10.0%. Through the different colours and blinking status of the indicators, users can intuitively know the status of the network connection, such as whether the connection is established, whether the connection speed is 10Mbps or 100Mbps, etc.




  • LTI Drives CDF30.002.C0.7 Compact Servo Controller 08685963 DC 24V Industrial Module
  • LUST LTI Drives CDB32.008.W2.4.BR.PC1 Servo Drive Industrial Motion System
  • LUST LTI Drives CDB34.003.C2.4.PC1.H15 Servo Motor Driver Industrial Control Unit
  • LUST LTI Drives CDA32.004.C1.4.H08.B0 Servo Drive Mat. 3084456 Industrial Control
  • LUST LTI Drives CDE34.005.W2.2 Industrial Servo Drive Motion Control Unit
  • LUST LTI Drives CDA34.006.W3.0 Servo Drive Software V3.70-04 Industrial Controller
  • LTI Drives CDB32.004.C2.4.SH Servo Drive Compact Motion Controller
  • Woodward 9905-373 - Digital Synchronizer And Load Controller
  • WOODWARD MAGNETIC PICKUPS - Sensor
  • WOODWARD GCP-30 - Steuertafel for Industrial Regulator Genset Control Package
  • WOODWARD GOVERNOR 9907-1183 REV A - 505 ENHANCED TURBINE CONTROL
  • WOODWARD 9907-173 REV B - Module Load Sharing 120 Volt
  • WOODWARD 9907-014 - 2301A controller
  • Woodward 9905-029 - SPM-A Synchronizer Module Rev C
  • WOODWARD 8440-1799 EASYGEN-350 REV B - Genset Controller
  • WOODWARD 5466-258 REV M - SIMPLEX DISCRETE I/O MODULE
  • Woodward 8440-1884 C - Controller Easygen 2500-5
  • Woodward 8441-1153 - Monitoring Unit 250VAC
  • WOODWARD 8406-120 REV G - EGCP-2 DIGITAL CONTROL
  • Woodward 8273-584 - Atlas-ii Digital Control
  • Woodward 8272-582 - APM Motor Control 8272582
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8272-517 - Pm Motor Control
  • WOODWARD 9905-797 REV.B - DIGITAL SYNCHRONIZER AND LOAD CONTROL DSLC-D
  • WOODWARD 8272-582 - APM MOTOR CONTROL
  • Woodward Seg FP2-8-24 - Emergency Power Telecommunications Module NP2
  • WOODWARD 2001-12E2U1B1S1A - Fuel Shut Off Valve Stop Solenoid Valve 2000-4505
  • Woodward 8440-1884 K - Genset Controller Easygen-2500-5
  • Woodward 9905-760 - Linknet Termination Module
  • Woodward 8404-009 - Proact Digital Plus Front Panel Rev. H
  • Woodward 8271-651 - Digital Speed Reference
  • Woodward 3077-474C - 8605895 5501-031 D Circuit Module
  • WOODWARD 5466-257 REV.-C - NETCON 5000 MODEL REMOTE TRANSCEIVER I/O MODULE
  • Woodward 8273-101 Rev: A - 2301D Digital Load Sharing and Speed Control
  • WOODWARD 8272-799 - 2301A SPEED CONTROL WITH REMOTE REFERENCE REV:C
  • Woodward 8272-517 - PM Motor Control
  • Woodward 8290-048 8290048 Rev. F - Generator Load Sensor
  • woodward 8273-1012 rev c - 2301e Load Sharing and Speed Control
  • WOODWARD 9905-797 - DIGITAL SYNCHRONIZER AND LOAD CONTROL FOR 3 PHASE GENERATORS
  • WOODWARD 8280-3014 - 723 PLUS DIGITAL CONTROL REV NEW
  • WOODWARD 8440-1884 REV G - GENSET CONTROLLER EASYGEN-2500-5/P1
  • Woodward 8272-683 K - Digital Reference
  • WOODWARD 9907-014 - SPEED CONTROL 2301A REV H
  • Woodward Type UG-8 P/N 037260 - Governor R.P.M 1075-1650 Motor KM58-20
  • WOODWARD 9905-970 - LINKNET 6 CHANNEL 100 OHM RTD Rev:J
  • Woodward 9907-1183 Rev C - Steam Turbine Digital SCREEN 505E Turbine Control
  • Woodward 8440-1614 - GCP-30 Genset Control Package, Rev: F, Type 1, E231544
  • Woodward DC11006-304-024 - ACTUOTOR DYNA ACTUATOR - BARBER-COLMAN
  • Woodward 9905-971 - LINKNET 6 CHANNEL 100 OHM RTD Rev:K
  • Woodward DYNK-10249 - Actuator Controller Kit - DYNA 2000
  • Woodward LR21035 - MFR1 MULTI FUNCTION RELAY REV F
  • Woodward 8440-1831 - EASYGEN 3200-5 P/N: REV. G Gererator Controller
  • Woodward 8272-516 - PM MOTOR CONTROL REV J
  • Woodward 8440-2080 - EASYGEN 2000 genset controller EASYGEN-2300-5/P1
  • Woodward 505DE - Digital Control System
  • Woodward 701 - Digital Speed Control 18-40 VDC 4-20 MA
  • Woodward 8440-1799 - EASYGEN-350 REV B
  • Woodward 8272-582 - Apm Motor Control 100-220v AC/DC
  • Woodward 5501-031 D - 3077-474C 8605895 Circuit Module
  • Woodward XD1-T - XD1T55SAT TRANSFORMER DIFFERENTIAL PROTECTION RELAY
  • Woodward 8272-517 - PM Motor Control 220vac
  • Woodward 8934-658 - Repair Kit UG8D Governor
  • Woodward 5437 18 - module netcon derivative analog rev.A
  • Woodward 8272-171 A - Pm Motor Control
  • Woodward MRN3-1/2 - SEG mains uncoupling relay MRN314D mains decoupling relay
  • Woodward 9905-373 - Digital Synchronizer and Load Control 18-40 VDC Rev P
  • Woodward 5431-640 C - Dual Dynamics 1000 Series Speed Control Module
  • Woodward 5501-031 D - 3077-474C 8605895 Circuit Module
  • Woodward 9907-247 - 828 DIGITAL CONTROL
  • Woodward 8440-1855-G - EASYGEN-2200-5 /P1 12/24VDC GENSET CONTROLLER
  • Woodward NC3-2-8 (NO) - GENERATOR CONTROLLER
  • Woodward 8271-467 K - 2301 LOAD SHARING AND SPEED CONTROL PART NO:
  • Woodward 8440-2177 A - SPM-D2-10 Digital Synchronising Controller
  • Woodward LXMG1614E-14-11 - CCFL and UV Lamps Inverter Module
  • Woodward 8270-990 - signal converter
  • Woodward 9905-068 - LOW VOLTAGE 2301A LOAD SHARING & SPEED CONTOL P/N:
  • Woodward 8901-051 - BOOSTER SERVOMOTOR, SINGLE CYLINDER, 2:1
  • Woodward 8444-1024 D - MWS4-55M CONTROL MODULE UNIT
  • Woodward 5448-914 - GCP-20 Genset Control GCP-20 REV D P/n:
  • Danfoss BHA-1 018-1942 - Hydraulic Actuator
  • Woodward 9905-001 L - SPM-A SYNCHRONIZER
  • Woodward 5464-850 - Module
  • Woodward 5501-371 - Micronet Simplex Mpu Aio Rev C
  • Woodward 8272-132 B - POWER SENSOR
  • Woodward 9907-028 - SPM-A Synchronizer
  • Woodward SA-3678-AM-2 - Overspeed Electric Governor, Model ESSE2-AM
  • Woodward E8250-502 - GOVERNOR ACTUATOR
  • Woodward 8440-1884 J - Controller EASYGEN-2500-5
  • Woodward 5441-693 - DIGITAL I/O MODULE -MISSING PART
  • Woodward SA-4450 - Speed Controller APECS 3100 For Magnetic Pickup
  • Woodward 9903-466 - 701 DIGITAL SPEED CONTROL REV G
  • Woodward 1765-843 - Governor Speed Adjusting Motor P/N Type: SMM40 220V AC 50/60Hz
  • Woodward 9905-760 - Linknet Termination Module
  • Woodward 9907-247 - 828 DIGITAL CONTROL UNIT REV K
  • Woodward 5484-721 - motor
  • Woodward 8440-1734 - MFR-2 Rev.A Multi Function Relay MFR-2
  • Woodward CSC3SUWA - Controller
  • Woodward 8440-1667 - REV B SPM-D1010B/XN
  • Woodward 8406-120 - egcp-2 digital control
  • Woodward DPG-2201-002 - DIGITAL CONTROLLER REV D
  • Woodward 8272-516 - Pm Engine Control Rev J
  • Woodward 8440-1831 - EASYGEN 3200-5 P/N: REV. K - WITHOUT ACCESSORIES
  • Woodward 8273-101 - LOAD SHARING & SPEED CONTROL
  • Woodward 8440-1855-G - EASYGEN-2200-5 /P1 12/24VDC GENSET CONTROLLER
  • Woodward 9907-247 - 828 DIGITAL CONTROL UNIT REV K
  • Woodward LR21035 - MFR1 MULTI FUNCTION RELAY REV J
  • Woodward 8404-009 - PROACT DIGITAL PLUS FRONT PANEL REV J
  • Woodward 9905-204 - Rev N SPM-A synchronizer
  • Woodward 8521-367 - UG-8 P/N r R.P.M 750-1280 Governor / UG8
  • Woodward 9907-175 - Load Sharing Module Rev. B
  • Woodward 5464-645 - DRIVER MODULE REV A 2C ACT DRIVE
  • Woodward 8404-009 - PROACT DIGITAL PLUS FRONT PANEL REV J
  • Woodward 9907-175 - Load Sharing Module Rev. B
  • Woodward 8406-102 - Rev A EGCP-2 Digital Control Engine Generator 8406102
  • Woodward EASYGEN-2500-5 - Controller Genset
  • Woodward 8440-2082 - Controller
  • Woodward 8272-516 - PM MOTOR CONTROL REV J
  • Woodward 9905-373 - Digital Synchronizer and Load Control 18-40 VDC Rev P
  • Woodward 5501-429 - Actuator Controller 25mA 2 Channel , (UPP)
  • Woodward 8440-1869 - SPM-D10 Synchronizing System Control-SPM-D10B/PSY4-F-D
  • Woodward 9907-175 - Load Sharing Module Rev. A
  • Woodward 8200-224 - Servo Position Controller
  • Woodward 9906-619 - 723 PLUS DIGITAL CONTROL ( 8280-604 )
  • Woodward 8440-1519 - EASYGEN PART NO: REV: 4
  • Woodward 5501-371 - REV C MODULE- MICRONET SIMPLEX MPU & AIO FTM
  • Woodward EASYGEN-3200-5/P1 - Generator Controller Module Rev F
  • Woodward 8440-1884K - GENERATOR CONTROLLER EASYGEN-2500-5 REV,K
  • Woodward 5466-353 - REV C NETCON MAIN CHASSIS TRANSCEIVER