K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

AB 1757-SRM ProcessLogix and ControlLogix System Redundancy Module

From: | Author:Wang | Time :2025-04-18 | 275 visit: | 🔊 Click to read aloud ❚❚ | Share:

AB 1757-SRM ProcessLogix and ControlLogix System Redundancy Module

Safety-related Precautions

Operation in Hazardous Environments: This module is suitable for use in certain hazardous locations (Class I Division 2 Groups A, B, C, D and non-hazardous locations). When operating in these environments, be sure to disconnect the power or confirm that the area is safe before connecting, disconnecting, or replacing the components, otherwise serious accidents, such as explosions, may occur.

Static electricity protection: The module is sensitive to static electricity. When operating, touch a grounded object to discharge static electricity, wear a grounded wrist strap, and avoid touching connectors, pins, and internal circuit components. When conditions permit, use an electrostatic safe workstation and store the equipment in an anti-static package when not in use.


Electrical Safety: Plugging and unplugging a module under power can cause an electric arc that not only damages the module and connectors, but can also cause an explosion in a hazardous location. Therefore, when installing or removing a module in a hazardous location, make sure that the power is off or that the area is free of hazards. Also, be sure that the module relay terminals are powered in compliance with UL and CE standards and that the line voltage of the external DC power supply is the same as the power supply powering the SRM chassis.


Installation and Equipment Requirements

Environmental conditions: This equipment is intended for use in industrial environments in pollution degree 2, overvoltage category II applications at altitudes up to 2000 metres above sea level. Use in other environments may present electromagnetic compatibility problems. The device is open and needs to be installed in a suitable enclosure that is flame retardant, has a protection rating of at least IP54 (in Class I, Zone 2 environments) and has internal live parts that are accessible with tools.

Equipment compatibility: The redundant system components must be identical, including the order of the primary and secondary control chassis and their internal modules, as well as the firmware versions of all modules. Otherwise, the 1757-SRM module will not allow the secondary chassis to mate with the primary chassis.


Installation Procedure Considerations

Pre-installation: Before installation, familiarise yourself with the operation of the module and learn about the redundancy system and redundancy media. Prepare the required components, such as the specific chassis, power supply, and fibre optic cables, and follow the appropriate installation instructions for installing and connecting the ControlLogix chassis and power supply. Determine the module mounting slots in the chassis; different chassis models have different recommended slots.

Installation Procedure: When connecting the fiber optic cable, connect one end to the module's fiber optic port before installing the module . When mounting the module, ensure that the board is aligned with the chassis guides and slide in smoothly so that it is flush with the other mounting modules. If a user relay is used, connect the wires to the detachable terminal block after passing them through the ferrite core and plug them into the relay terminals, taking care to operate with the power off to avoid arcing.


System Configuration and Upgrade: After assembling the chassis, specify the primary chassis and qualify the system to ensure that all module pairs have compatible firmware versions. Before specifying a primary chassis, flash upgrade the factory boot firmware of the 1757-SRM module. When upgrading the module firmware, the programmes and data in the device should be backed up, as the upgrade will overwrite the original data.

IMPORTANT INFORMATION AND SAFETY NOTICE: Solid-state devices have different characteristics than electromechanical devices. Ensure that the application meets the requirements before using the device and Rockwell Automation will not be responsible for consequential damages. Document examples are for reference only and may not be reproduced without permission. The manual contains a variety of cautionary statements to alert the user to the dangers of explosion, static electricity, electric shock, and burns, as well as the potential for damage to equipment and injury or death from mishandling. This equipment is intended for use in specific hazardous locations and is to be operated and maintained in accordance with relevant safety regulations, such as operating without power and using qualified components.


Module Overview and Preparation for Installation: 1757 - SRM Series B Modules for ProcessLogix or ControlLogix Redundant Chassis Pairs require knowledge of module operation, redundancy systems, and protection against static electricity prior to installation. Prior to installation, prepare the required components, install and connect the ControlLogix chassis and power supply, identify the module mounting slots, and match the redundant system components, including the chassis and module firmware versions.


Installation and Usage: To assemble the redundant system, assemble two identical chassis, connect the fibre optic cables, and install the modules, taking care to avoid energising the system during installation. If a user relay is used, it must be wired to a detachable terminal block and plugged into the relay terminals. Modules can be installed or removed under power but at some risk. Modules can be reset by cycling power to the chassis or by plugging or unplugging the module. To remove a module, follow the specific procedure and replace the module in its original slot.


Module Status and Troubleshooting: The module has a variety of status indicators, such as module status, health status, communication status and chassis status indicators, which indicate the module's operating status and fault conditions through different displays and colours. Faults are classified into four categories and recorded in the event log, which can be viewed through the module's four-character status display, and corresponding measures, such as reset and replacement of the module, are taken according to different fault types.


Specification and certification information: The module has specific specifications in terms of electrical, physical and environmental aspects, including backplane current, size, weight, mounting method, temperature code, power requirements, insulation resistance, etc . A variety of certifications, such as UL, CSA, FM, CE, etc., are available to comply with relevant standards for use in different regions and environments.

Resources and Contacts: Technical documentation resources are available for review and download on our website, or in paper form by contacting your local distributor or sales representative Rockwell Automation provides web-based and telephone support, and product returns and exchanges are available in accordance with established procedures.

ALLEN BRADLEY 1757-SRM ProcessLogix System Redundancy Module at ₹ 26880 ...


  • ADLINK PCI-7433 - switch value acquisition card Isolated Digital Input Card
  • ADLINK PCI-9112 - 51-12252-0D20 Multi-Function Data Acquisition Card
  • ADLINK NUPRO-A301 REV:1.4 - industrial control motherboard PICMG Full-Size SBC
  • ADLINK 51-18502-0A10 - Frame Grabber Image Acquisition Interface Card
  • ADLINK PCI-7296 - 51-12009-0A50 PCB-I-E-925=6DX1 96-CH Parallel Digital I/O Board
  • ADLINK PCI-8132 GP A2 - Motion Control Card 2-Axis Servo & Stepper Controller
  • ADLINK PCI-7442 - switch quantity card data acquisition card 64-CH Isolated Card
  • ADLINK HPX-13S4 - baseboard PICMG 1.3 Passive Backplane Chassis Baseplate
  • ADLINK NuPRO-590 / NTC-567-ZM-F36 - Single Board Computer PCB-I-E-1853=9L21 Half-Size SBC
  • ADLINK PCIe-8332 - 16-axis plate Motion Control Hardware Card
  • ADLINK NuPRO-775 REV.B1 - motherboard Pentium 4 Full-Size PICMG SBC
  • ADLINK PXI-3920 - Embedded Controller 3U PXI cPCI System Intelligence Board
  • ADLINK PCI-8134 - driver card motion control card 4-Axis Controller Board
  • ADLINK HSL-DI32-M-N-011 / HSL-TB32-M-DIN - Digital Input & Base Module PLC Distributed I/O System
  • ADLINK PCI-6216V-206 / PCI-208V 009 - 16 CH 16bit analog output card
  • ADLINK NuPro-E330 - 51-41805-0A20 PCB Single Board Computer Host Board
  • ADLINK PCI-1622C - Card 8-Port RS-232/422/485 PCI Serial Communication Board
  • ADLINK PCIe-7432 - 51-18402-0A10 Carte PCIe Avec Plage D'Entrée Élevée Isolated DIO Card
  • ADLINK PCI-7250 - PCI Acquisition Card 8-CH Relay Output Isolated DI Card
  • ADLINK PCI-7230 - 32-CH Isolated Digital I/O Card
  • ADLINK PCI-8164 - PCB 4-Axis Motion Controller Card
  • ADLINK PCI-7854 - Collection card High-Speed Link Distributed Motion Controller
  • ADLINK NuPRO-935A/LV - industrial control computer motherboard Full-Size PICMG SBC
  • ADLINK IMB-M40H - motherboard IH61-AA4 1155 LGA1155 Micro-ATX Mainboard
  • ADLINK PCI-7248 - Linhua 51-12006-0A40 48-CH Parallel Digital I/O Card
  • ADLINK HPCI-14S12U - Linhua industrial computer baseboard Passive Backplane
  • ADLINK PCI-8132 Rev.A2 - 2-Axis Servo & Stepper Motion Controller Card
  • ADLINK ACL-8111 - ISA card Multi-Function DAQ Card
  • ADLINK ACL-8111 - ISA card Multi-Function Data Acquisition Board
  • ADLINK PCI-7200 REV.A3 - Digital I/O card 12MB/s High-Speed Parallel Digital I/O
  • ADLINK PCI-7296 REV.A3 - 96-CH High-Density Opto-Isolated DIO Card
  • ADLINK PCI-7434 - 64-CH Isolated Digital Output Card
  • ADLINK M-342 - atx motherboard Industrial PC Mainboard
  • ADLINK NuPRO-935ADV (A) 1.9 - CPU Board Intel Core 2 Quad CPU Q9500 2.83GHz PICMG Board
  • ADLINK NUPRO-935A/DV - motherboard dual network port 51-41802-0A10 CPU Board
  • ADLINK PCI-RTV24 - image capture card Analog Video Frame Grabber Board
  • ADLINK HPX-13S4 - device baseboard PICMG 1.3 Passive Backplane Chassis Baseplate
  • ADLINK PCI-8134A - control card 4-Axis Motion Controller Card
  • ADLINK ACL-7130 REV. B2 - industrial control capture card Isolated Digital I/O Board
  • ADLINK EBP-13E2 - Industrial Backplane Board Passive Backplane Baseboard
  • ADLINK NuPRO-935ADV (A) 1.9 - CPU Board Intel Core 2 Quad CPU Q9500 2.83GHz PICMG SBC
  • ADLINK PCI-8134A - motion control card 4-Axis Pulse-Train Controller Card
  • ADLINK PCI-9112 REV A.1 - Multi Function DA&C Board Data Acquisition Card
  • ADLINK 51-12001-0C20 - Circuit Board Multi-Function Data Acquisition Hardware
  • ADLINK PCI-7300A - 80-CH High-Speed Digital I/O Card
  • ADLINK PCI-7230 - 16-CH Isolated Digital Input Output Card
  • ADLINK DIN-814-GP - motion control module Interface Terminal Block
  • ADLINK NUPRO-A40H - 51-41807-1A20 Industrial Control Motherboard LGA1155
  • ADLINK PCI-7433 rev A2 - Isolated Digital Input Card
  • ADLINK NuPRO-780 - Pentium III 800 512 MB SBC NuPRO780 51-41309-0B2 Single Board Computer
  • ADLINK PCI-7853 / PCI-7854 - Acquisition card High-Speed Link Control Card
  • ADLINK NUPRO-852 / NUPRO-852LV - Industrial motherboard Full-Size PICMG CPU Board
  • ADLINK NuPRO-842LV/P - 51-41360-0B30 Industrial Motherboard Half-Size PICMG SBC
  • ADLINK PCI-FIW64 - 4/2 Channel IEEE1394B Image Capture Card Frame Grabber
  • ADLINK PCI-7851 Rev A1.1 - HSL system card High-Speed Link Master Controller
  • ADLINK PCI-7230 - 51-12003-0A50 card 32-CH Isolated Digital I/O Card
  • ADLINK NuPRO-841REV:1.0 - Industrial CPU Board Mainboard
  • ADLINK NuPRO-841 REV:1.0 - motherboard Industrial Control PC Mainboard
  • ADLINK PCI-8256 - 8-Axis Advanced Motion Control PCI Board
  • ADLINK PCI-6S / PCI6S - Backplane 6-Slot Passive Backplane Board
  • ADLINK PCI-7234 REV B3 - 32-CH Isolated Digital Output PCI Card
  • ADLINK PCI-8213 - HannStar MV-4 51-45003-0b4 Board
  • ADLINK PCI-7233 - 51-12004-0a20 board PCI7233 32-CH Isolated Digital Input Card
  • ADLINK PCI-7851 - 006 51-24003-0B20 High-Speed Link Master Motion Control Card
  • ADLINK PCI-7432 - 64-CH Isolated Digital I/O PCI Cards
  • ADLINK LPCI-3488 - Card Low Profile IEEE-488 GPIB Interface Card
  • ADLINK HPCI14S REV.B1 - industrial control computer base plate Passive Backplane
  • ADLINK NEON-1020 - Industrial camera Smart Camera Vision System
  • ADLINK PCI-7432 - Isolated Digital I/O PCI Card 64-CH
  • ADLINK Pcm-7250+ - 8-Ch Relay Outputs & 8-Ch Isolated DI Module PC/104
  • ADLINK CPCI-7841 - DUAL-PORT ISOLATED CAN INTERFACE CARD CompactPCI
  • ADLINK PCI-3488 / PCI-GPIB - PCI IEEE-488 GPIB Interface Card
  • ADLINK PCI-1711U - Card Multi-Function Data Acquisition Board
  • ADLINK NUPRO-A301 - REV:1.1 1.2 1.4 PICMG Full-Size Single Board Computer
  • Adlink DIN-50S-01 - PLOTECH 51-14024-0A40 50-pin Wiring Terminal Board
  • Chroma 52962 / 58183 - PXI Optical Spectrometer carrier adapter Card
  • ADLINK PCI-6208V - PCI DATA ACQUISITION & RECORDING CARD 8-CH Analog Output
  • ADLINK HSL-DI32-DB-N - Industrial Control Board Distributed Digital Input Module
  • ADLINK HSL-AO4-U - 4-CH HIGH SPEED LINK ANALOG OUTPUT MODULE Distributed I/O
  • ADLINK PCI-7396 - 0050 GP 51-12012-0B20 96-CH High-Speed Digital I/O Card
  • ADLINK NUPRO-935A/DV - 51-41802-0A10 motherboard Industrial CPU Single Board Computer
  • ADLINK PCI-9111 DG - Industrial Acquisition Card Multi-Function DAQ Card
  • ADLINK NuPRO-E315 - industrial computer motherboard Intel Atom SHB SBC
  • ADLINK NUPRO-406 REV:B1 - Industrial Control Motherboard Full-Size PICMG CPU Board
  • ADLINK NuPRO-E330 - motherboard Industrial Control System Host Board PICMG 1.3
  • ADLINK ACL-6128A 103 - 51-11002-1A4 2-CH Isolated Analog Output Card
  • XTRAMUS cPS-H325/AC - POWER SUPPLY NUSTREAMS 600 NETWORK TESTING EQUIPMENT Power Module
  • ADLINK DIN-814P-A4 - 51-14056-0A10 Terminal Block Motion Control Breakout Board
  • ADLINK TB-24P/24-01 - 24-Channel Card Terminal Breakout Board
  • ADLINK PCI-7251 - 51-12008-0A30 PCI7251 8-CH Relay Output Isolated Digital Input Card
  • ADLINK HSL-TB64-DIN REV A1 / HSL-DO32-DB-N - 2ea Board Breakout Terminal Board Distributed I/O Module
  • ADLINK NuPRO-865 REV 3.0 - industrial computer motherboard Full-Size PICMG SBC
  • ADLINK NUPRO-A40H - motherboard 51-41807-1A30 OSP H61 Industrial PC Mainboard
  • ADLINK LPCI-3488A - PCI Card 51-12801-0A30 GPIB Interface Card
  • ADLINK DIN-825-4P0 - 51-14085-0A30 Terminal Printed Circuit Board Breakout Block
  • ADLINK IMB-T10/D2550 V - MOTHER BOARD 80-PXG160-A1A01 IMB-T10-M2G-S32G Industrial Mainboard
  • ADLINK PCI-8144N - Motion Control card Stepper Motor Controller
  • ADLINK PCI-7433 - Digital acquisition card Isolated Digital Input Card
  • ADLINK PCI-9112 DG - Data Acquisition card 51-12252-0D20 Multi-Function DAQ
  • ADLINK IMB-M40H - motherboard IH61-AA4 1155 LGA1155 Micro-ATX Mainboard
  • ADLINK TB-24P/24-01 - Carte 24 voies Terminal Breakout Board Connector Module
  • ADLINK HSL-D16DO16-M-NN - Distributed Discrete Input Output I/O Module
  • ADLINK PCI-7248 - PCI CARD 51-12006-0A40 48-CH Parallel Digital I/O Board
  • ADLINK HSL-DI32-DB-N - Industrial Control Board Distributed I/O Digital Input Module
  • ADLINK PCI-7433 - Pci 7433 Isolated Digital Input Card
  • ADLINK PCI-6208V - 008 Data acquisition card 8-CH Analog Output Card
  • ADLINK IH61-AA4 - industrial motherboard LGA1155 Micro-ATX Mainboard
  • ADLINK PXI-3920 - PXI 3U cPCI Industrial Controller Embedded System CPU Board
  • ADLINK PCI-6308 - Analog Output DAQ Card Isolated Voltage Output Card
  • ADLINK PCI-7200 - data acquisition card REV.A3 High-Speed Parallel DIO Card
  • ADLINK NuPRO-E315 - Industrial Control Computer Motherboard PICMG 1.3 SHB SBC
  • ADLINK PCI-1610C - Card 4-Port Isolated RS-232 PCI Serial Communication Card
  • ADLINK PCI-1716 - Card High-Resolution Multi-Function DAQ Card
  • ADLINK MI-965 - Industrial Mini-ITX Motherboard CPU Board
  • ADLINK PCI-1610A - Card 4-Port RS-232 PCI Serial Communication Card
  • ADLINK cBP-3208/3208R - CPCI Board 3U 8-Slot CompactPCI Backplane
  • ADLINK PCI-8134A - 51-12421-0A10 4-Axis Motion Controller Card
  • ADLINK PCI-8164 - Motion Control Card 4-Axis Advanced Controller Card
  • ADLINK NUPRO-935A/DV - motherboard dual network port 51-41802-0A10 CPU Board
  • ADLINK PCI-7248 - 51-12006-0A40 acquisition card 48-CH Parallel DIO Card
  • ADLINK PCI-7443 - 51-12022-0A10 BOARD 128-CH Isolated Digital Input Card
  • ADLINK DIN-825-GP4 - Terminal Block Interface Board Breakout Module
  • ADLINK PCI-7248 - Card 48-CH Parallel Digital I/O Card
  • ADLINK NUPRO-865 REV :3.0 - industrial motherboard Intel Pentium 4 CPU Board
  • ADLINK PCI-9113A - Isolated Analog Input Data Acquisition Card
  • ADLINK HPCI-8S4 - REV.B2 Industrial Control Base Plate Passive Backplane
  • ADLINK M-342 - atx motherboard Industrial PC Mainboard
  • ADLINK PCI-RTV24 - image capture card Analog Video Frame Grabber Board