+086-15305925923

K-WANG

Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

AB 1786 - RPA/B ControlNet Modular Repeater Adapter

From: | Author:Wang | Time :2025-04-22 | 86 visit: | Share:

AB 1786 - RPA/B ControlNet Modular Repeater Adapter

Product Summary: The 1786 - RPA/B Repeater Adapter with specific modules builds repeaters for ControlNet networks, extending the network, switching topologies and media, and connecting up to 20 in series.

IMPORTANT: Unlike electromechanical devices, solid-state devices should be used in a manner that ensures proper application and Rockwell Automation is not responsible for consequential damages. Examples in this document are for illustrative purposes only and may not be reproduced without permission. Various safety warnings are given, such as operating in hazardous environments, protection against static electricity, and other precautions.


Environmental and Installation Requirements

Environmental conditions: Suitable for use in industrial environments with pollution level 2, overvoltage category II, at altitudes up to 2000 metres above sea level, Group 1, Class A industrial equipment, to be installed in a suitable enclosure.

Hazardous Location Use: For North American hazardous locations, products labelled ‘CL I, DIV 2, GP A, B, C, D’ have specific temperature code requirements; for European Zone 2 environments, equipment must be mounted in an enclosure with at least IP54 protection.

Static electricity protection: The device is sensitive to static electricity and should be operated in accordance with protective measures such as touching grounded objects, wearing a wrist strap, etc.


Module mounting

Mounting preparation: Horizontal mounting is recommended, vertical mounting is also possible (top mounting is recommended), using DIN rails made of zinc-plated yellow chromate steel and properly grounded.

Mounting procedure: Hang the module on the DIN rail at an angle of 30° and rotate it to snap into place, mount the repeater module, secure it with the DIN rail lock, make sure that the total number of modules and the power consumption do not exceed the limits, tighten the screws to 1.1 N・m.

Module wiring: Disconnect the power when wiring, prepare tools and wires, connect the wires to the V in+ and V in terminals of the RTBs after stripping, tighten the screws to 0.6 - 0.8 N・m, install the RTBs and connect them to the ControlNet network, connect the unused ports with a 75Ω terminator.

Status indicators: The status indicators are available in different combinations to indicate different states. For example, alternating red/green indicates that the module is powered up or reset; solid red indicates that a node is continuously transmitting on the network; and off indicates unpowered or faulty.


Technical Specifications

Electrical Specifications

Power Consumption and Power Dissipation: Maximum power consumption is 16.8 W and maximum power dissipation is 8.8 W. These two parameters reflect the energy consumption and heat dissipation requirements of the device during operation, which is of great significance to the power configuration and heat dissipation design of the system. In practice, it is necessary to ensure that the power supply can provide sufficient power, and at the same time to consider the heat dissipation measures of the equipment to ensure its stable operation.


Input Voltage: The input voltage is rated at 700mA @ 24V DC, which is classified as Class 2/SELV (Safety Extra Low Voltage). The input voltage range is 18 - 36V DC, which means that the device can operate normally within a certain voltage fluctuation range, but exceeding this range may affect the performance of the device or even cause damage. When selecting a power supply, it is important to ensure that the output voltage meets the requirements of the device.

Backplane Output Current: The maximum backplane output current is 1.6A @ 5V DC, which limits the total current consumption of other devices connected to the backplane. When designing a system, it is necessary to consider the power consumption of the connected devices to avoid exceeding the limit of the backplane output current, which may lead to device failure or unstable operation.


Mechanical specifications: The minimum enclosure dimensions are approximately (12 x 7.75 x 4 in.) i.e. 304.8 x 196.8 x 101.6 mm, which specifies the space occupation of the device, and when installing the device, it is necessary to make sure that there is enough space to accommodate the device. There is no restriction on the mounting direction of the device, and the appropriate mounting method can be selected according to the actual situation, but horizontal mounting is preferred, and it is recommended that the device be mounted on the top when installed vertically.


Environmental specifications

Temperature: The maximum ambient air temperature is 140°F (60°C), which limits the ambient temperature range in which the unit can be used. When used in a high temperature environment, care should be taken to dissipate heat to prevent damage to the unit due to overheating. If the ambient temperature exceeds the equipment's tolerance range, it may result in reduced performance, shortened life, or even failure.


Vibration and Shock: In terms of vibration, the device complies with IEC60068 - 2 - 6 (Test Fc, Operating) and can withstand vibration of 5 g @ 10 - 500 Hz; in terms of shock, the device complies with IEC60068 - 2 - 27 (Test Ea, Unpackaged Shock) and can withstand shock of 30 g. These parameters indicate that the device can withstand a certain level of vibration and can withstand a shock of 30 g. The device can withstand a shock of 30 g if the ambient temperature exceeds the range. These parameters indicate that the equipment can maintain normal operation in a certain vibration and shock environment, but in practice, the equipment should try to avoid excessive vibration and shock.


Electromagnetic compatibility: It has certain electromagnetic compatibility, such as ESD (electrostatic discharge) immunity of 6 kV contact discharge and 8 kV air discharge; Radiated RF immunity has different requirements in different frequency ranges, such as 10V/m with 1 kHz sine - wave 80% AM from 80 - 2000 MHz, etc; EFT/B immunity is ±4 kV at 5 kHz at power and communication ports; Surge transient immunity has different tolerance values at different ports, e.g. ±1 kV line - line (DM) and ±2 kV line - earth (CM) at power port, etc.; Conducted RF Immunity is 10V rms with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz. These parameters ensure that the device can work properly in complex electromagnetic environments without causing interference to other devices.


Approvals: Several approvals have been obtained, including UL (UL Listed Industrial Control Equipment), CSA (CSA Certified Process Control Equipment, etc.), FM (FM Approved Equipment for use in), FM (FM Approved Equipment for use in), and FM (FM Approved Equipment for use in). FM (FM Approved Equipment for use in Class I Division 2 Group A,B,C,D Hazardous Locations), CE (European Union 2004/108/EC EMC Directive etc.), C-Tick (Australian Radiocommunications Act), Ex (European Union 94/9/EC ATEX Directive) and CI (ControlNet Int'l conformance tested to ControlNet specifications). These certifications indicate that the equipment complies with relevant safety, quality and industry standards and is safe for use in the respective regions and environments.

1786-RPA | Allen-Bradley | ControlNet Modular Repeater Adapter


  • ABB CAI04 - Analog Input Module
  • ABB PM866-2 3BSE050201R1 - Process Manager Module
  • ABB CP405 A0 1SAP500405R0001 - Communication Processor
  • ABB R474A11XE HAFAABAAABE1BCA1XE - Protection Relay
  • ABB REF542PLUS 1VCR007346 - Protection Relay
  • ABB REF542PLUS 1VCF752000 - Protection Relay
  • ABB PPD113B03-26-100100 3BHE023584R2625 - Power Distribution Module
  • ABB PCD232A 3BHE022293R0101 - Process Control Module
  • ABB PFEA113-65 3BSE050092R65 - Process Control Module
  • ABB XVC768102 3BHB007211R102 - Control Module
  • ABB XVC767AE102 3BHB007209R0102 - Control Module
  • ABB CI857K01 3BSE018144R1 - Communication Interface Module
  • ABB 3ASC25H219B DATX133 - Control System Module
  • ABB 3ASC25H208 DATX100 - Control System Module
  • ABB 3ASC25H214 DATX130 - Control System Module
  • ABB 3ASC25H204 DAPU100 - Control System Module
  • ABB 3ASC25H216A DATX132 - Control System Module
  • ABB LWN2660-6 - Communication Module
  • ABB ICSE08B5 FPR3346501R1012 - Interface Module
  • ABB 1MRK00008-KB - Protection Relay Component
  • ABB UAD155A0111 3BHE029110R0111 - Control Module
  • ABB PU515A 3BSE032401R1 - Power Unit Module
  • ABB TU810V1 3BSE013230R1 - Terminal Unit
  • ABB XO08R2 1SBP260109R1001 - Output Module
  • ABB 3BHL000986P0006 - Communication Module
  • ABB SC540 3BSE006096R1 - System Controller
  • ABB REF615C_E HCFDACADABC2BAN11E - Protection Relay
  • ABB 5SHY4045L0001 3BHB018162R0001 3BHE009681R0101 GVC750BE101 - IGBT Power Module System
  • ABB P4LQA HENF209736R0003 - Power Module
  • ABB FENA-11 - Network Module
  • ABB COM0003 2RAA005844A0006A - Communication Module
  • ABB AIM0006 2RCA021397A0001F - Analog Input Module
  • ABB REF615C_C HCFFAEAGANB2BAN1XC - Protection Relay
  • ABB S-073N 3BHB009884R0021 - Power Module
  • ABB REF615E_E HBFHAEAGNCA1BNN1XE - Protection Relay
  • ABB TP830 3BSE018114R1 - Touch Panel
  • ABB 5SHX2645L0004 3BHL000389P0104 3BHB003154R0101 5SXE04-0150/GVC707AE01 - IGBT Power Module System
  • ABB DSAI146 3BSE007949R1 - Analog Input Module
  • ABB LC-608 - Control Module
  • ABB TK803V018 3BSC950130R1 - Terminal Module
  • ABB RF522 3BSE000743R1 - Field Communication Module
  • ABB DSRF197 3BSE019297R1 - System Module
  • ABB DSAO120A 3BSE018293R1 - Analog Output Module
  • ABB DSDP170 57160001-ADF - Process Control Module
  • ABB DSBC176 3BSE019216R1 - System Module
  • ABB DSDO115A 3BSE018298R1 - Digital Output Module
  • ABB DSDI110AV1 3BSE018295R1 - Digital Input Module
  • ABB BC810K01 3BSE031154R1 - Base Controller
  • ABB 5SHY3545L0010 3BHB013088R0001 3BHE009681R0101 GVC750BE101 - IGBT Power Module System
  • ABB 81943A041-1 - Industrial Component
  • ABB PM865K01 3BSE031151R1 - Process Manager Module
  • ABB SA168 3BSE003389R1 - System Module
  • ABB 5SHY3545L0016 3BHB020720R0002 3BHE019719R0101 GVC736BE101 - IGBT Power Module System
  • ABB TP853 3BSE018126R1 - Touch Panel
  • ABB REM545AG228AAAA - Protection Relay
  • ABB CI626A 3BSE005029R1 - Communication Interface Module
  • ABB NDCU-12C NDCU-12CK - Network Control Unit
  • ABB REM615C_D HCMJAEADAND2BNN1CD - Protection Relay
  • ABB IBA 940143201 - Interface Module
  • ABB PFSK151 3BSE018876R1 - Process Control Module
  • ABB IDPG 940128102 - Display Module
  • ABB PP825 3BSE042240R1 - Panel Module
  • ABB OCAH 940181103 - Control Module
  • ABB OCAHG 492838402 - Control Module
  • ABB TP857 3BSE030192R1 - Touch Panel
  • ABB PP865A 3BSE042236R2 - Panel Module
  • ABB CI854A-EA 3BSE030221R2 - Communication Interface Module
  • ABB SCYC51020 58052582H - System Control Module
  • ABB SCYC51090 58053899E - System Control Module
  • ABB SCYC51010 58052515G - System Control Module
  • ABB CB801 3BSE042245R1 - Communication Module
  • ABB SCYC51040 58052680E - System Control Module
  • ABB 5SHY4045L0001 3BHB018162R0001 - IGBT Power Module
  • ABB 5SHY6545L0001 AC10272001R0101 5SXE10-0181 - IGBT Power Module System
  • ABB RMU811 - Remote Monitoring Unit
  • ABB RFO810 - Field Output Module
  • ABB CS31 - Control System
  • ABB TVOC-2-240 1SFA664001R1001 - Voltage Controller
  • ABB SDCS-AMC-CLAS2 - Drive System Module
  • ABB LDSTA-01 - Display Module
  • ABB GJR5252300R3101 07AC91H - Control Module
  • ABB GJR5252300R3101 07AC91F - Control Module
  • ABB TB711F 3BDH000365R0001 - Terminal Base
  • ABB PM783F 3BDH000364R0001 - Process Manager Module
  • ABB CM772F 3BDH000368R0001 - Communication Module
  • ABB TU715F 3BDH000378R0001 - Terminal Unit
  • ABB DC732F 3BDH000375R0001 - DC Controller
  • ABB TTH300 - Terminal Module
  • ABB PFEA111-65 3BSE050091R65 - Process Control Module
  • ABB UNS3670A-Z V2 HIEE205011R0002 - Power Electronics Module
  • ABB RC527 3BSE008154R1 - Remote Controller
  • ABB 5SHY5055L0002 3BHE019719R0101 GVC736BE101 - IGBT Power Module System
  • ABB PM864AK01 3BSE018161R1 - Process Manager Module
  • ABB DSDP140A - Process Control Module
  • ABB UBC717BE101 3BHE021887R0101 - Power Electronics Module
  • ABB PPC380AE01 HIEE300885R0001 - Power Controller
  • ABB UFC718AE01 HIEE300936R0001 - Power Electronics Module
  • ABB KUC720AE01 3BHB003431R0001 3BHB000652R0001 - Control Unit System
  • ABB DSAI130A 3BSE018292R1 - Analog Input Module
  • ABB TP854 3BSE025349R1 - Touch Panel
  • ABB 5SHY3545L0016 3BHB019719R0101 GVC736BE101 5SXE06-0160 - IGBT Power Module System
  • ABB 07KT97 GJR5253000R4270 - Control Terminal
  • ABB 07KT98 GJR5253100R4278 - Control Terminal
  • ABB 07KT98 GJR5253100R0278 - Control Terminal
  • ABB PFTL101B 5.0KN 3BSE004191R1 - Force Sensor
  • ABB 5SHX1445H0002 3BHL000387P0101 - IGBT Power Module
  • ABB 3HNM07686-1 3HNM07485-1/07 - Motor Module
  • ABB GRBTU 3BSE013175R1 - Terminal Unit
  • ABB DSMB127 57360001-HG - System Module
  • ABB DSBB110A 57330001-Y - System Module
  • ABB DSCS131 57310001-LM - System Module
  • ABB DSCA114 57510001-AA - System Module
  • ABB PFSK130 3BSE002616R1 - Process Control Module
  • ABB PFSK164 3BSE021180R1 - Process Control Module
  • ABB PFSK162 3BSE015088R1 - Process Control Module
  • ABB PFSK160A 3BSE009514R1 - Process Control Module
  • ABB DSBC172 57310001-KD - System Module
  • ABB DSMC112 57360001-HC - System Module
  • ABB DSRF180A 57310255-AV - System Module
  • ABB DSTC175 57310001-KN - Terminal Controller
  • ABB DSSB140 48980001-P - System Module
  • ABB UAC389AE02 HIEE300888R0002 - Control Module
  • ABB UNS0881a-P,V1 3BHB006338R0001 - Power Electronics Module
  • ABB KUC755AE105 3BHB005243R0105 - Control Unit
  • ABB KUC755AE105 3BHB005243R0105 - Control Unit
  • ABB PM783F 3BDH000364R0002 - Process Manager Module
  • ABB 5SHY3545L0009 3BHB013085R0001 3BHE009681R0101 GVC750BE101 - IGBT Power Module System
  • ABB LXN1604-6 3BHL000986P7000 - Communication Module