GE Grid Solutions 369 Series

From: | Author:Wang | Time :2025-09-19 | 527 visit: | 🔊 Click to read aloud ❚❚ | Share:

GE Grid Solutions 369 Series

Basic product positioning and affiliated system

Product identification: The core product is the 369 series Digital Relays, which belongs to the power system protection and control product line of GE Grid Solutions. It is mainly used for equipment protection, monitoring, and control scenarios in medium and low voltage power networks.

Document attribute: This document is a product brochure (Brochure), with the core objective of showcasing product features, advantages, and applicable scenarios to customers in the power industry (such as power companies, industrial distribution departments, and engineering general contractors). The document includes key information such as product technical highlights, application areas, and selection support.

Core product features and technological highlights

1. Multi dimensional protection function (core value)

The 369 series relay focuses on "comprehensive protection" and covers common types of equipment failures in the power system, including:

Overcurrent protection: For overload and short circuit faults of equipment such as lines, transformers, motors, etc., multiple protection logics such as definite time and inverse time are provided to adapt to different load characteristics.

Grounding fault protection: supports residual current detection, quickly identifies single-phase grounding, three-phase unbalanced grounding and other faults, and avoids fault expansion (especially suitable for neutral point ungrounded or arc suppression coil grounded systems).

Special equipment protection: customized protection algorithms are provided for specific equipment such as transformers (such as over temperature and differential auxiliary protection), motors (such as locked rotor and phase loss protection), capacitors (such as overvoltage and undervoltage protection), etc.

Backup protection function: It can serve as a backup for the main protection and automatically activate when the main protection fails, ensuring the "multi-level protection" of the power system and improving power supply reliability.

2. Monitoring and data collection capabilities

Real time parameter monitoring: Continuously collect electrical parameters such as voltage, current, power, frequency, power factor, etc., with accuracy meeting industrial standards (such as current measurement accuracy ± 0.5%, voltage ± 0.2%), and supporting remote data reading.

Fault recording and event recording: When a fault occurs, automatically record the waveform of electrical parameters before and after the fault (the recording time can be configured) and the timing of events (such as switch action time, protection action logic), which facilitates post fault analysis and responsibility tracing.

Status diagnosis: Monitor the hardware status of the device (such as power supply and sampling module) and the operating trend of the protected equipment (such as motor winding temperature trend), and provide early warning of potential faults (such as module aging and equipment degradation).

3. Control and communication characteristics

Local/Remote Control: Supports local panel operations (such as manual opening and closing, protection setting modification) and remote control (remote control of switches and setting issuance through communication interfaces), suitable for the needs of "unmanned substations" or "remote operation and maintenance".

Flexible communication interface: Ethernet (such as Modbus TCP, IEC 61850), serial port (RS-485/232, such as Modbus RTU) and other communication protocols are standard or optional, which can be connected to SCADA (Supervisory Control and Data Acquisition System), DCS (Distributed Control System) or power automation platforms to achieve data interconnection and intercommunication.

Fixed value management: supports multiple sets of protection fixed value storage and switching (such as "operation fixed value" and "maintenance fixed value"), adapts to different operating conditions (such as seasonal load changes and equipment maintenance modes), and the switching process does not require power outage.

4. Usability and reliability design

Human computer interaction: equipped with a small LCD display screen (supporting Chinese/English interface switching) and buttons, with intuitive operation; Some models support exporting data (such as fault recording files and operation logs) through the USB interface, simplifying on-site debugging.

Hardware reliability: Industrial grade components are used, with a protection level of IP30 (panel installation) or IP20 (cabinet installation), and a working temperature range covering -40 ° C to+70 ° C, suitable for harsh industrial environments such as high and low temperatures, humidity, electromagnetic interference, etc; Support redundant power input (optional) to avoid protection failure caused by single power failure.

Compliance: Complies with international and industry standards, such as IEC 60255 (General Standard for Relays), ANSI/IEEE C37.20.1 (Standard for Metal Enclosed Switchgear), GB/T 14598 (Chinese Relay Protection Equipment Standard), ensuring compliant use in different countries/regions.

Applicable application scenarios

The 369 series relays are widely used in various fields of medium and low voltage power systems due to their strong versatility and flexible adaptability, including:

Industrial power distribution systems, such as motor control centers (MCC), transformer cabinets, and capacitor compensation cabinets in factory workshops, protect critical production equipment from faults and reduce downtime losses.

Commercial and civil buildings, such as large shopping malls, office buildings, and data centers, use power distribution systems to ensure stable power supply for important loads such as air conditioning, lighting, and IT equipment, avoiding business interruptions caused by power outages.

Power distribution network: such as 10kV/0.4kV lines, ring main units, and box type substations in urban distribution networks, serving as line protection and monitoring nodes to enhance the reliability and operational efficiency of the distribution network.

Renewable energy access: Adapt to the grid connection protection of distributed photovoltaics and small-scale wind power, prevent the impact of new energy generation fluctuations on the power grid, and ensure grid connection safety (such as overvoltage and overclocking protection).

Customer Value and Service Support

1. Customer core revenue

Improving reliability: By using multi-level protection and rapid fault removal, the equipment damage rate is reduced and the duration of power outages is reduced (such as fault removal time ≤ 50ms, which is much faster than traditional relay protection).

Reduce operation and maintenance costs: remote monitoring and diagnostic functions reduce the frequency of on-site inspections; Fault recording and event recording simplify fault analysis and shorten fault handling time.

Flexible Expansion: Supports seamless integration with other power automation products from GE Grid Solutions, such as SCADA systems and distribution management platforms, to meet customers' upgrade needs from single point protection to system intelligence.

2. Service and Support

The brochure mentions that GE provides full lifecycle services, including:

Selection support: Provide customized selection suggestions based on the customer's equipment type (such as transformer capacity, motor power) and power grid topology (such as radiation network, ring network).

Installation and debugging: Provide technical manuals, on-site debugging guidance (or paid on-site services) to ensure that the product is correctly integrated into the system.

After sales maintenance: Provide spare parts supply, software upgrades (such as protection algorithm updates), fault repairs, and other services to ensure the long-term stable operation of the product.


Product series and selection tips

Model subdivision: The 369 series includes different sub models (such as 369-P, 369-M, 369-C), focusing on "line protection", "motor protection", and "capacitor protection" respectively. Customers need to choose the corresponding sub model according to the type of protected equipment.

Configuration options: Some functions (such as redundant power supply, IEC 61850 communication, temperature acquisition module) are optional configurations, and customers can flexibly customize according to their actual needs (such as whether they need to connect to the smart grid platform).


  • Woodward 8272-796 - Real Power Sensor Module 115/230v-ac
  • Woodward 5463-873 - NetCon Output Module
  • Woodward 8271-567 - Load Sensor Module 120/208v-ac
  • Woodward Type UG-8 P/N 8522-300 EG - Governor R.P.M 1075-1650 With Motor Groschopp
  • WOODWARD 9905-971 REV J - LINKNET 16 CHANNEL DISCRETE INPUT MODULE
  • WOODWARD 8280-3014 - 723 PLUS DIGITAL CONTROL REV NEW
  • Woodward 505DE - Digital Control System
  • Woodward 5453-750 - Ethernet Interface FTM
  • Woodward 9907-018 Rev H - 2301A Load Sharing & Speed Control
  • WOODWARD 5420-1080 V4.3 - BOARD-PPA WITHBOX
  • Woodward b 8271-347SP - 2301 speed control
  • Woodward 9905-795 Rev B - Digital Synchronizer and Load Control
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8272-582 - Generator speed control module
  • WOODWARD 9907-247 REV K - 828 DIGITAL CONTROL UNIT
  • WOODWARD 5466-353 REV C - NETCON MAIN CHASSIS TRANSCEIVER
  • Woodward Type UG-8 P/N 8524-708 - Governor 760-1560 Governor R.P.M
  • WOODWARD 9907-247 REV K - 828 DIGITAL CONTROL UNIT
  • WOODWARD 8440-1831 REV. H - EASYGEN3000 3200-5 - WITHOUT ACCESSORIES
  • WOODWARD 8444-1002 REV G - UMT1 MEASURING TRANSDUCERS
  • Woodward 5410-312C - Digital Marine Control Printed Circuit Board
  • Woodward 9905-799 REV F - Digital Synchronizer & Load Control , V#456
  • Woodward 9907-014 - 2301A for controller
  • Woodward Type UG-8 P/N B522-446 - Governor R.P.M 500-1200
  • WOODWARD 8272-221 REV.B - DIGITAL REFERENCE UNIT
  • Woodward 8901-037 - Booster Servomotor Single
  • WOODWARD 8444-1019 REV G - UMT 1 MEASURING TRANSDUCER
  • WOODWARD 1767-367 Z21 WK 0920702 - GOVERNOR MOTOR 2700 RPM KM 58-20 K 230V
  • WOODWARD 9905-972 Rev:G - LINKNET 6 CHANNEL 4-20mA OutPut
  • Woodward E8250-501 - Actuator Governor
  • WOODWARD 5466-258 REV M - SIMPLEX DISCRETE I/O MODULE
  • WOODWARD 5501-470 REV E - NETCON CPU MODULE
  • Woodward 8406-120 rev H - egcp-2 digital control
  • Woodward 8440-1799 - Easygen-350 Rev B
  • Woodward 8440-1878 - DSLC-2 Digital Synchronizer Load Control
  • Woodward 5464-843 - Cpu Processor Module
  • WOODWARD 8440-1409 Rev. J - MFR2 MDE Synchronization & Protection MSP
  • Woodward 9907-014 - controller
  • WOODWARD 9907-173 - LOAD SHARING MODULE 120V
  • WOODWARD 8440-1831 REV. K - EASYGEN 3200-5 - WITHOUT ACCESSORIES
  • Woodward 9905-969 - LinkNet Module LinkNet 6C 4-20ma in w/24v
  • Woodward 8520-498 - Governor Type UG-8 Governor R.P.M 850-1650
  • WOODWARD 5466-257 REV.-C - NETCON 5000 MODEL REMOTE TRANSCEIVER I/O MODULE
  • WOODWARD 8800 - 1001 REV-C - DSS-2, 2 CHANNEL DIGITAL SPEED SWITCH
  • WOODWARD 5501-467 REV. C - MICRONET SIMPLEX POWER SUPPLY
  • Woodward 8273-584 - Atlas-ii Digital Control
  • Woodward 8440-1019 b - spm-d10 synchronizing system
  • Woodward CSC3SUWA REV K - CSC3SUWA Controller
  • Woodward 5441-693 Rev B - Digital I/O Module
  • WOODWARD DPG-2201-002 REV.D - Governor Onan DIGITAL SPEED CONTROLLER
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8440-1884K - GENERATOR CONTROLLER EASYGEN-2500-5 REV,K
  • WOODWARD 8404-1006 - Industrial Component
  • WOODWARD 5437-1118 - PROTECHTPS MODULE Relay Bulkhead Panel
  • Woodward 8440 1801 Rev C - Easygen-350-50B/X Genset Control Engine Generator 24VDC
  • WOODWARD 5466-348 - MODULE
  • Woodward 9905-799 REV F - Digital Synchronizer & Load Control , V#456
  • Woodward 9907-018 - 2301A Load Sharing & Speed Control Rev H
  • Woodward GM9412H918-R2 1766-039 REV E - Cruise Control Motor
  • 5466-258 WoodWard - 48 Input 24 Output Discrete I/O, (UPP)
  • WOODWARD 5484-877 - PM MOTOR 24VDC 15RPM
  • Woodward 8272-221 B - Digital Reference Unit
  • Woodward 9905-796 - Digital Synchronizer And Load Control (Rev. H)
  • WOODWARD 5441-645 REV.G - 10AMP RELAY INTERFACE 11459968
  • Woodward 9907-207 - 721 Digital Control 88-132VAC
  • WOODWARD 8272-582 - APM MOTOR CONTROL AC/DC 100~220V
  • Woodward 5464-843 - Cpu Processor Module
  • Woodward 9905-001 L - SPM-A Synchronizer 115/230V 50/60Hz 10W
  • Seg Power Protection PCK4 P/N 8445 1006 A / PCKR-MW - Protection Relay 24VDC
  • Woodward 8405-062 - Actuator
  • Woodward 5464-738 - Industrial Control System
  • Woodward CSC3HUWB - controller
  • Woodward 8272-517 - PM Motor Control 220vac
  • Woodward 8272-582 - APM Motor Control
  • Woodward LR20025 MFR1375M MFR 1 - Controlling
  • Woodward 9905-392 - Proact Driver Model III
  • WOODWARD 8250-774 - ACTUATOR/GOVERNOR
  • Woodward 505DE - Digital Control System
  • Woodward 8280-303 D - 721 Digital Control Rev.G 2.0 AMP 28 VDC
  • WOODWARD DPG-2201-002 REV NEW - DIGITAL CONTROLLER
  • WOODWARD 8272-286 - 2301A LOAD SHARING & SPEED CONTROL MODULE
  • WOODWARD 8440-1884 REV M - GENSET CONTROLLER EASYGEN-2500-5/P1
  • Woodward 9905-797 Rev. M - Digital Sync And Charge Control
  • W0ODWARD ART-01681 - IDS Communicator Control Box
  • Woodward 8273-584 - Digital Control Unit ATLAS-II REV: A 18-32VDC, 60W
  • WOODWARD 5501-470 REV E - NETCON CPU MODULE
  • Woodward 1752 1752-227 - Revision D FireFly Current Load input Engine Control
  • Woodward 8440-1877 - MSLC-2-5 Control
  • Woodward 8271468 - Generator Loading Control (Rev. D)
  • Woodward 9905-387 - Pro Act Driver Model lll (Rev. F)
  • Woodward 9905-363 - Sincronizzatore Digitale E Controllo Carico
  • WOODWARD 8272-583 - APM MOTOR CONTROL
  • WOODWARD EGCP-2 - Digital Generator Control Panel 4-20MA 5V 500HZ
  • Woodward 9905-392 - Proact Driver Model III
  • Woodward 9905-392 - Proact Driver Model III
  • Woodward 8270-007 - Load Signal Control
  • Woodward 8271-651 - Digital Speed Reference
  • WOODWARD 8440-2219 - EASYGEN-2500-5-P1-K49 GENSET CONTROLLER
  • Woodward D8271-394 - 2301 Load Sharing And Speed Control Module 20-40v-dc
  • Woodward 8200-1504 Rev:E - Peak200 Steam Turbine Control Front Panel Mount HVAC
  • LTI Drives CDF30.002.C0.7 Compact Servo Controller 08685963 DC 24V Industrial Module
  • LUST LTI Drives CDB32.008.W2.4.BR.PC1 Servo Drive Industrial Motion System
  • LUST LTI Drives CDB34.003.C2.4.PC1.H15 Servo Motor Driver Industrial Control Unit
  • LUST LTI Drives CDA32.004.C1.4.H08.B0 Servo Drive Mat. 3084456 Industrial Control
  • LUST LTI Drives CDE34.005.W2.2 Industrial Servo Drive Motion Control Unit
  • LUST LTI Drives CDA34.006.W3.0 Servo Drive Software V3.70-04 Industrial Controller
  • LTI Drives CDB32.004.C2.4.SH Servo Drive Compact Motion Controller
  • Woodward 9905-373 - Digital Synchronizer And Load Controller
  • WOODWARD MAGNETIC PICKUPS - Sensor
  • WOODWARD GCP-30 - Steuertafel for Industrial Regulator Genset Control Package
  • WOODWARD GOVERNOR 9907-1183 REV A - 505 ENHANCED TURBINE CONTROL
  • WOODWARD 9907-173 REV B - Module Load Sharing 120 Volt
  • WOODWARD 9907-014 - 2301A controller
  • Woodward 9905-029 - SPM-A Synchronizer Module Rev C
  • WOODWARD 8440-1799 EASYGEN-350 REV B - Genset Controller
  • WOODWARD 5466-258 REV M - SIMPLEX DISCRETE I/O MODULE
  • Woodward 8440-1884 C - Controller Easygen 2500-5
  • Woodward 8441-1153 - Monitoring Unit 250VAC
  • WOODWARD 8406-120 REV G - EGCP-2 DIGITAL CONTROL
  • Woodward 8273-584 - Atlas-ii Digital Control
  • Woodward 8272-582 - APM Motor Control 8272582
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8272-517 - Pm Motor Control
  • WOODWARD 9905-797 REV.B - DIGITAL SYNCHRONIZER AND LOAD CONTROL DSLC-D
  • WOODWARD 8272-582 - APM MOTOR CONTROL
  • Woodward Seg FP2-8-24 - Emergency Power Telecommunications Module NP2
  • WOODWARD 2001-12E2U1B1S1A - Fuel Shut Off Valve Stop Solenoid Valve 2000-4505
  • Woodward 8440-1884 K - Genset Controller Easygen-2500-5