+086-15305925923

K-WANG

Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

ABB 615 series ANSI protection and control

From: | Author:Wang | Time :2025-07-16 | 6 visit: | Share:

ABB 615 series ANSI protection and control

Product overview

The ABB 615 series is a series of protection and control products that have undergone partial testing according to relevant standards and meet all specified requirements without any misoperation, malfunction, or electrical damage. This series of products is manufactured by ABB Oy Distribution Solutions, and the relevant testing is approved by ABB Inc. Distribution Solutions and Distribution Automation.


Test object

Main test models include RED615 (order number HBDDFEADNLA1BMD11G), REF615 (order number HBFNAEFCNHA1AQB21G), REG615 (order number HBGDBDADNBA1BFG1G1), and the test results are also applicable to other products in the 615 series.

Basic modules: Each model includes CPU module, power module, binary I/O module, analog input module, LHMI module, communication module, backplane module, etc. The module types and parameters of different models may vary slightly. For example, RED615 uses PSM0004 power module, REF615 uses PSM0003 power module, etc. In addition, type testing was conducted on the IEC LHMI module DIS0012, and since the PCBA of ANSI and IEC LHMI are the same, the test results are also applicable to the ANSI LHMI module DIS0014.

REX615 - Protection and control products for power distribution ...

Various test results

Mechanical structure inspection: Marking and mechanical structure comply with IEC 60255-1 and IEC 60255-27 standards; The embedded shell level is IP 54 on the front and IP 10 on the back and connection terminals, in compliance with IEC 60529 standard; The electrical clearance and creepage distance comply with IEC 60255-5 and IEC 60255-27 standards, and the results are both OK.

Overload and input testing: Under rated current, rated voltage and other parameters, the thermal tolerance, dynamic current tolerance, input impedance, load, voltage tolerance, etc. all meet the requirements of IEC 60255-1 and IEC 60255-27 standards. For example, for a rated current of 0.2/1A, the continuous thermal tolerance is 4A, and the 1-second thermal tolerance is 100A.


Power module testing: In terms of auxiliary voltage, PS-H has no effect at 38... 300 VDC, 38... 264 VAC, and PS_L has no effect at 12... 72 VDC; In the voltage drop immunity test, the product can operate normally or restart under different voltage and residual voltage conditions; During the auxiliary power supply voltage interruption test, the product was able to shut down and restart normally; The tests for DC auxiliary voltage ripple, gradual shutdown and startup, and DC power polarity reversal all meet the requirements; At the same time, the power consumption of different power modules is provided.

Contact testing: Different types of contacts (bipolar power output, unipolar power output, signal output, etc.) meet the requirements of IEC 60255-1 and IEEE C37.90-2005 standards in terms of making ability, breaking ability, mechanical tolerance, etc. For example, the bipolar power output continuously carries a current of 8A, and the 3-second turn-on and carrying current are 15A, etc.


Electromagnetic compatibility testing: Pulse interference testing at 1MHz/100kHz, pulse interference testing at 3MHz and other frequencies, electrostatic discharge testing, radio frequency interference testing, surge immunity testing, power frequency magnetic field immunity testing, and other electromagnetic compatibility tests all comply with the requirements of corresponding standards (such as IEC 61000-4 series, IEC 60255-26, etc.).

Insulation testing: dielectric testing, impulse voltage testing, insulation resistance measurement, protective grounding resistance testing, etc., in accordance with the requirements of standards such as IEC 60255-27 and IEEE C37.90-2005. For example, passing the dielectric test under the conditions of 2kV, 50Hz, and 1 minute.


Mechanical testing: vibration testing, impact and collision testing, earthquake testing, mechanical durability testing, etc., in accordance with the Level 2 requirements of standards such as IEC 60068-2 series, IEC 60255-21 series, IEEE C37.90-2005, etc.

Environmental testing: dry heat testing, dry cold testing, wet heat testing, temperature change testing, storage testing, etc., in accordance with the requirements of IEC 60068-2 series, IEEE C37.90-2005 and other standards. For example, the dry heat test passed at+55 º C for 96 hours and+85 º C for 16 hours (some products passed at+70 º C).


Characteristic

Compact and flexible design: adopting a withdrawable unit design, the structure is compact, occupies small space, and is easy to install, test, and maintain. Products such as REF615 and RET615 have a pull-out design that facilitates replacement or maintenance during equipment operation, and are compact in size, making them suitable for space limited substations and other locations. This design can also reduce the space required for equipment installation, improve space utilization, and reduce equipment costs.

Comprehensive functionality: covering multiple protection and control functions, capable of meeting the needs of different power systems. For feeder protection, it has functions such as underground and overhead cable fault detection (CFD), high impedance (HIZ) fault detection, arc flash detection (AFD), etc. REF615 can effectively detect and respond to various faults during feeder operation. In terms of transformer protection, sensitive differential protection is used for inter turn faults, overexcitation (V/HZ) protection, etc. RET615 can provide comprehensive protection for transformers. In addition, it also includes various protection functions such as overcurrent, thermal overload, grounding fault, overvoltage, undervoltage, as well as special functions such as frequency protection and phase discontinuity protection, comprehensively ensuring the stable operation of the power system.


Good communication compatibility: Supports multiple communication protocols, including IEC 61850 (supporting Edition 2 and Edition 1, including HSR, PRP, GOOSE messaging, and IEC 61850-9-2 LE), IEEE 1588 V2 (for high-precision time synchronization) Modbus ®、 DNP3, etc. Through these protocols, the product can communicate and interoperability with devices from different manufacturers, facilitating the construction of complex power automation systems, achieving data sharing and remote monitoring, and enhancing the level of system intelligence.

High reliability: Through careful design and selection of high-quality components, the product has strong reliability and can provide stable and high-quality electricity, reducing equipment failures and power outages. For example, in some industrial sites with extremely high requirements for power reliability, such as steel plants, data centers, etc., the 615 series products can operate continuously and stably, ensuring normal production and business operations, and reducing losses caused by power problems.


Easy to upgrade and maintain: With ready-made standard configurations, it is convenient to quickly set up and customize, supports flexible system upgrades, and does not require rewiring or component replacement. When expanding or upgrading the system, users can achieve it through software configuration or adding modules, reducing upgrade costs and complexity, and improving system adaptability. In addition, it also provides a wide range of lifecycle services, such as training, customer support, maintenance, and modernization, to provide users with comprehensive protection.

ABB RET615 ANSI Transformer protection and control Numerical Relay


  • Alstom MVAW11R1AB9000A - Single Phase Overcurrent AC Relay
  • CONVERTEAM GM0023002 / GM0023002 - Module
  • CONVERTEAM MAE00-08 / MAE0008 - Termination Panel
  • Alstom Minisemi D 380 (415) / 60+ Go V3.1 029.135722 - Power Conversion
  • CONVERTEAM 20X4384/40 / 20X438440 - Module
  • CONVERTEAM 31V1700/10 / 31V170010 - Power Supply
  • CONVERTEAM 1.666.204.63 / 166620463 - Module
  • CONVERTEAM 20X1448/10 / 20X144810 - Module
  • Alstom Blueline - (24) Card Power Plant Control 70RK01
  • GE Alstom Cegelec IC693PWR324T - Alspa 80-35 Power Supply Module 30W STD
  • Alstom MiCom P241311A2M0570J - Motor Protection Relay 0395
  • Alstom Micom p40 - Agile Distance Relay Transmitter p44291ab6m0720m
  • Alstom vag11yf8011adch - no voltage relay 110v ac
  • ALSTOM CEGELEC DS - DROSSEL AK 140022 - Transformer 029.144857
  • CONVERTEAM MBCZ12302H1CB2211F / MBCZ12302H1CB2211F - Relay
  • CONVERTEAM M83-60002 / M8360002 - Trip Detector Unit
  • ALSTOM MVAP22L1AA0001B - VOLTAGE MONITORING RELAY
  • Alstom KCGG14201T50CEC - Single Phase Overcurrent AC Relay by Areva
  • CONVERTEAM MVAA11B1BA0533C / MVAA11B1BA0533C - Relay
  • CONVERTEAM 25X8281/30 / 25X828130 - Module
  • CONVERTEAM 1-645-509-27 / 164550927 - Module
  • Alstom Alspa MV3000 MV3168A4A1 - 3 Phase Inverter speed controller CONVERTEAM
  • ABB Servo Motor Type F12M4H 57344 - Alstom,
  • Alstom Alspa MD2000 - Multiverter 102/122-400 029146631 Frequency Converter
  • Alstom Train Work Overalls - Large Brand New
  • TR11 - GEC ALSTHOM TR11/Module - Relay Tropic Alstom
  • 6F00 - ALSPA 6F00/Module - Alstom C50 Power Board 24V
  • TR11 - GEC ALSTHOM TR11 - / Modulo Rel¨¦ Tropic Alstom
  • TR11 - GEC ALSTHOM TR11 - / Modul Relais Tropic Alstom
  • CONVERTEAM 590.043150 / 590043150 - Module
  • CONVERTEAM 20X4331/10 / 20X433110 - Module
  • CONVERTEAM MAE00-11 / MAE0011 - Termination Panel
  • CONVERTEAM 1.645.515.27 / 164551527 - Module
  • Alstom SPC160 - Servomotor Position Controller v2.1 Unused
  • CONVERTEAM GSGB-200 / GSGB200 - Fuse
  • CONVERTEAM 20X4259/20 / 20X425920 - Module
  • CONVERTEAM 20X4252/10 / 20X425210 - Module
  • CONVERTEAM 28X3563/10 / 28X356310 - Module
  • CONVERTEAM MMLG01465518G / MMLG01465518G - Test Block
  • CONVERTEAM GDS1009-4001 / GDS10094001 - Keypad
  • CONVERTEAM 20X4245/40 / 20X424540 - Module
  • CONVERTEAM MSTZ02B1AA0751C / MSTZ02B1AA0751C - Relay
  • Alstom Cegelec MINISEMI D500/200+GO V3.1 - Type. 029.135731 200A Converter
  • CONVERTEAM TMV311 / TMV311 - Module
  • 3Ph Inverter Drive MV502A4C1 - Alstom 0.75kW Alspa MV500 Rebadged SE23400075
  • CONVERTEAM 20X4502/10 / 20X450210 - Module
  • Alstom MiCom P241311A2M0570J - Motor Protection Relay 0395
  • 6F00 - ALSPA 6F00 / Module - Alstom C50 Power Supply Board 24V
  • Alstom TGD430486P1 - Center Rotor Weight Balancing Segment 54.86 X 30 X 36
  • CONVERTEAM 20X4342/10 / 20X434210 - Module
  • CONVERTEAM 20X4321/10 / 20X432110 - Module
  • CONVERTEAM MAE00-14 / MAE0014 - Termination Panel
  • Alstom 1349 - Carbon Ring 2 pieces 3-3/4 inches ID
  • CONVERTEAM 20X4330/10 / 20X433010 - Module
  • CONVERTEAM MBCI01F1AD0761B / MBCI01F1AD0761B - Module
  • TR11 - GEC ALSTHOM TR11 / Module - Relay TROPIC ALSTOM
  • Alstom CK 112 - Relay
  • GE Alstom Cegelec IC693MDL240F - Alspa 80-35 Digital Input Module 16 Port VGC
  • CONVERTEAM MVAA21R1BA0751B / MVAA21R1BA0751B - Relay
  • CONVERTEAM MBCI01FAB0511A / MBCI01FAB0511A - Module
  • CONVERTEAM 20X4332/20 / 20X433220 - Module
  • CONVERTEAM 20X4386/60BCOAT / 20X438660BCOAT - Module
  • ALSTOM 029.063 253 - Perfect condition Pulse Amplifier 029
  • CONVERTEAM PRS11N04A / PRS11N04A - Relay
  • CONVERTEAM 20X4322/10 / 20X432210 - Module
  • CONVERTEAM MMLG01R1AA9002D / MMLG01R1AA9002D - Test Block
  • ALSTOM MCAG 14 - 1687 High Stability Protection Relay 14C1BB0005B
  • Cegelec Alspa GD2000 30V4800/60 - Gem Drive Delta Controller Alstom
  • 6F00 - ALSPA 6F00/Module - Alstom C50 Power Board 24V
  • GE Alstom Cegelec IC693PWR324T - Alspa 80-35 Power Supply Module 30W STD
  • Alstom CZ922 - Relay
  • Alstom CK112 - Relay
  • Auburn Engineering 1G-4765-C - New! Spark Ignitor Plug Assembly Alstom
  • Areva Alstom CZ912 - Relay
  • CONVERTEAM MVAA12J1BG9013C / MVAA12J1BG9013C - Relay
  • ALSTOM ALSPA MV500 MV524A4C1A - 11KW inverter
  • CONVERTEAM TTM-560 / TTM560 - Module
  • ALSTOM 07452-9076-BA - Bellows Front Plate
  • Alstom PS421 - Overcurrent time protection device P89421-0-1420000-300-403-600-705
  • GE Alstom Cegelec IC693PWR324X - Alspa 80-35 Power Supply Module 30W STD
  • Areva Alstom KCGG14201T50CEC - Single Phase Overcurrent AC Relay
  • ALSTOM MVTT Timing Relay MVTT14R1NB0751E - Relay
  • ALSTOM Proximity Sensors Gmd0963071p0613 - Gmd 0963071 P613 New
  • Auburn Engineered 1G-4765-C - New! Spark Ignitor Plug Assembly Alstom
  • ALSTOM BROWN D321220R0001 C1 5782 001 HTGD90056 13 D - COUPLING HALF PUMP SIDE
  • Alstom CZ922 - Relay
  • Alstom CZ922 - Relay
  • Alstom CK112 - Relay
  • Alstom CK 112 - Relay
  • Alstom PS421 - Overcurrent time protection device P89421-0-1420000-300-403-600-705
  • The Tag FANUC Alstom STI 161 CS-C3 - Speed Turbine Interface Unused
  • ABB Servomotor Type F12M4H 57344 - Alstom
  • Alstom Mepo IP143 CS-C3 - Position Measurement Unused
  • CEGELEC Alstom Prsv LV108 - Board Used
  • Alstom 29.135722 - for Minisemi-D380 Platinum Board Card
  • Alstom Micom P40 agile P541211 B1M0300J - Distance Relay Transmitter, Used, GB ^
  • Alstom vaa11yf8752ca - Auxiliary Relay
  • ALSTOM Grid Bitronics M57121021001C - ,M5A121021001C,M571-VD13-D4-M256-IR1
  • CONVERTEAM MVC3001-3023 / MVC30013023 - Module
  • CONVERTEAM ALSPA-MV-1013 / ALSPAMV1013 - Inverter
  • Alstom Mepo IP143 CS-C3 - Position Measurement
  • Alstom Mepo IP143 CS-C3 - Position Measurement
  • ALSTOM ALSPA VNTC4825E - Drive
  • ALSTOM RR 3 MKB - Relay
  • CONVERTEAM 1-666-004-63 / 166600463 - Module
  • CONVERTEAM 25X9702/10 / 25X970210 - Module
  • Red spot BS88 TIA25 - industrial HBC fuse, 25A. by GEC ALSTOM
  • C-E ALSTOM 723 - NEW OLD STOCK Coal Pulverizer Housing Assembly
  • Alstom CK112 - Relay
  • 1-3Ph Inverter Drive MV506A2D1 - Alstom 1.1kW Alspa MV500 Rebadged SE2D200110
  • Alstom 94-167 - Journal Stop Bolt Bushing
  • ALSTOM MCGG22L1CD0753E - SINGLE PHASE OVER CURRENT & EARTH FAULT RELAY
  • CONVERTEAM P110155-10 / P11015510 - Module
  • Alstom SPC160 - Servomotor Position Controller v2.1 Unused
  • CONVERTEAM MCAG11J1EE9001A / MCAG11J1EE9001A - Relay
  • Areva Alstom CZ912 - Relay
  • New Old Stock C-E ALSTOM Mill 723 - Coal Pulverizer Gear Set
  • CONVERTEAM MVAA11B1BA0533C / MVAA11B1BA0533C - Relay
  • Tagged FANUC Alstom STI 161 CS-C3 - Speed Turbine Interface
  • ABB Servo Motor Type F12M4H 57344 - Alstom
  • ALSTOM Proximity Sensor Gmd0963071p0613 - Gmd 0963071 P613 New
  • CONVERTEAM 029.076.164 / 029076164 - Module
  • Alstom / AEG 3A60040G02 - , PC board
  • GE Alstom Cegelec IC693PCM301M - Alspa 80-35 Programmable Coprocessor Module 192k
  • CEGELEC Alstom Prsv LV108 - Board
  • CONVERTEAM MVAA12B1BG9013C / MVAA12B1BG9013C - Relay
  • CONVERTEAM 20X4348/40 / 20X434840 - Module
  • Alstom PS421 - Overcurrent time protection device P89421-0-1420000-300-403-600-705