ABB AO2040-CU Ex (2G Class) Central Unit Operating Instructions

From: | Author:Wang | Time :2026-11-12 | 4 visit: | 🔊 Click to read aloud ❚❚ ▶ | Share:

ABB AO2040-CU Ex (2G Class) Central Unit Operating Instructions

Installation

1. unboxing and installation foundation

The equipment weighs about 28kg and requires two people to transport and install it; The installation base must have sufficient load-bearing capacity.

The supply includes: AO2040-CU Ex host, analyzer data sheet, AO2000 complete manual, this simplified manual, and compressed air pretreatment filter.

Applicable explosion-proof zones: Zone1, Zone2; Outdoor installation is strictly prohibited.

Provide overall dimensional drawings (in millimeters) for wall mounted installation structures.

2. Explosion suppression gas pipeline connection (positive pressure shell blowing gas)

Blowing medium: Compressed air, meeting ISO8573-1 Class3 standards; The working intake pressure is 250-500kPa (2.5-5bar).

The supporting compressed air filter must be installed as close as possible to the explosion suppression gas valve at the inlet (DIN ISO G1/4 interface) to filter impurities and prevent valve jamming and incomplete closure; Impurities generated during pipeline mechanical processing can damage valves, and in extreme cases, the display screen buttons may bulge outward.

Select pipelines with sufficient diameter according to the length of the pipeline to ensure the blowing flow rate; Reserve cable channel space during wiring.

3. General principles for electrical wiring safety

Internal isolation relays and controller wiring in the factory can be modified, but additional internal cables/components are prohibited. Changes must be recorded in the analyzer data sheet.

The equipotential/protective grounding should be connected to the on-site equipotential busbar first, with a minimum of 4mm ²; Grounding disconnection can pose a danger.

All cables must be reliably fixed; The metal shielding layer of the shielded cable (system bus) is connected to the metal cable joint.

Intrinsic safety signal cable: Only light blue M20 cable connectors can be connected, and the distance between the internal equipment and non intrinsic safety cables should be at least 8mm.

RS232/RS485/Ethernet in Zone 1 cannot be directly connected to the circuit board port and must use factory preset isolation relays.

The power cable can only be connected to the positive voltage cabinet control unit, and it is strictly prohibited to directly connect it to the shell wiring port, otherwise the explosion-proof function will fail.

Idle cable glands must be sealed with original plugs, with a tightening torque of 2.5Nm; M20 glands are compatible with cable outer diameters of 6-12mm.

4. Definition of Electrical Interfaces

Light blue M20: intrinsic safety signal; Black M20: Non intrinsic safety signal, 24VDC power supply for AO2060 module; Metal M20: AO2060 analyzer module system shielded bus.

Onboard components: Isolation relays K01~K04 (K01 standard, other options, maximum 30VDC/0.4A); K05 bus terminal block; Z01 24VDC line filter; B01 positive pressure shell control unit; Optional: ER144A/Ex condensation monitoring isolation amplifier, flow monitoring isolation amplifier, current output isolator, solenoid valve driver, switch isolation relay, etc.

AO2060 analysis module connection points: The system bus and 24VDC cable are key components of the explosion-proof system, and the cable cannot be shorter than 1 meter and must not be damaged; The bus shielding layer needs to be pressed outward with a metal gland; Connect 24VDC to Z01 filter terminal.

Condensation monitoring ER144A/Ex: The intrinsic safety signal line is routed through a blue gland and connected to E1/E2 terminals; The maximum total length of the lead is 75m; a 100k Ω resistor is connected in parallel to the sensor side nearby (the stainless steel probe version is already pre installed).

5. Status signal, grounding and power wiring

Protective grounding PE, minimum 4mm ² equipotential connection.

Passive relay terminals 21 and 22 for positive and negative pressure alarm: When the pressure inside the housing is less than 1.2hPa, the contact opens; Contact closure at pressure ≥ 1.2hPa; The maximum contact specification is 250V, 5A.

Power supply: Connect B01 control unit terminals L (17), N (15), PE; The power consumption is about 200VA; the power supply circuit must be equipped with a circuit breaker that can be easily disconnected and properly labeled; The equipment voltage cannot be adjusted on site.

Operation and Maintenance

1. Installation checklist before startup

Check the explosion-proof area and temperature group; Confirm non outdoor installation and secure installation; Smooth blowing of air; The shell is well sealed; Idle gland seal in place; The blowing pipeline is correct; Can complete pre blowing; All cable wiring is fixed correctly; Grid voltage matching nameplate; Control unit cover closed; Release of bypass mode; The blowing pilot pressure is qualified; The distance between intrinsically safe cables and other cables is ≥ 8mm.

2. Equipment startup steps

Connect the power supply; 2. Open the explosion suppression and purging gas source; After completing the pre purge, the solenoid valve switches to leakage compensation mode and the internal unit of the housing is powered on.

Attention: Purging the intake pressure above 5 bar will cause abnormal pre blowing.

Power on phenomenon: Power, Maint, and Error indicators light up simultaneously; The screen displays the firmware version for startup; After completion, enter measurement mode; The STOP MESSAGE software button appears on the screen to view temperature and flow alarms during the heating stage.

3. Bypass mode (maintenance specific)

Bypass activation will cancel the positive pressure explosion-proof protection and only allow confirmation of the absence of explosive gases on site or holding a hot work permit, which must be approved by the operation and maintenance manager before use. The bypass must be closed for normal operation.

Activation: Open the B01 control unit cover, press BYPASS, enter password 4711, and press MENU; The purge air is turned off, and the screen BYPASS flashes.

Close: Enter 4711 with the same key, MENU, Blow the air back up and cover the lid.

4. Regular inspections

Perform inspections on the installation checklist before reusing the startup.


Application, Structure, Principle of Positive Pressure System, Technical Specifications

1. Equipment purpose

Paired with the AO2060 series analysis modules (Caldos15/17, Magnos106, Uras14) to achieve gas measurement process control and monitoring; Wall mounted casing, following EN60079-2 positive pressure casing with leakage compensation. The equipment can introduce intrinsic safety and non intrinsic safety circuits, and non intrinsic safety circuits must pass through isolation relays; The circuit below the display keypad is an intrinsic safety circuit.

2. Working logic of positive pressure shell system

Start pre blowing: The blowing volume is indicated on the nameplate; The internal unit can only be powered on after the blowing is completed.

Normal operation: Maintain a slight positive pressure of about 2hPa inside the shell; The pressure control valve limits the pressure inside the casing. The air consumption for running the purge is about 40L/h.

Pressure protection interlock: If the pressure inside the shell is lower than 0.8hPa or higher than 15hPa, all internal equipment will lose power and the isolation relay circuit will be disconnected; After the pressure is restored, perform a complete pre blow and then power on again.

Status relay output: When the pressure is below 1.2hPa (blowing, bypass, fault), the contact is disconnected; The pressure is normally closed.

The internal volume of the shell is 36L; the minimum flow rate for pre blowing is 1L/s; Blow the intake pressure to 250-500kPa.

3. Main technical parameters

Project parameters

Explosion proof certification DMT 03 ATEX E 006; II 2G Ex px e d [ib] IIC T4

Working environment temperature+5~+50 ℃; Storage and transportation -25~+65 ℃

Power supply 115/230VAC non switchable, 48-62Hz, power consumption approximately 200VA

Shell protection IP54, weight approximately 28kg

Blow air ISO8573-1 Class 3; Maximum particle size 40 μ m, oil ≤ 1mg/m ³, pressure dew point+3 ℃

4. Electrical safety and EMC

Safety level I, compliant with EN61010-1; The low voltage side is protected by PELV for extra low voltage.

EMC meets EN61326-1 industrial grade and Class B interference limit.

5. Installation and maintenance specifications for electrical equipment in hazardous areas

Follow the EN60079-14 explosion-proof electrical installation standard; Pay attention to anti-static measures.

Non intrinsic safety circuit maintenance must be powered off, and the circuit breaker must be hung with a warning sign reading "Do not close"; Intrinsic safety circuits can be operated with electricity, but attention should be paid to the capacitance and inductance parameters of the testing equipment.

Periodic inspection: Explosion proof electrical equipment without continuous online monitoring shall be inspected by certified electricians at least every 3 years.

Maintenance can only use original spare parts from the factory; After the repair of components that affect explosion-proof performance is completed, they must be inspected and certified by experts; ABB's on-site/return to factory maintenance can exempt third-party expert re inspection.

  • Wika IPT10 - Process Pressure Transmitter
  • Omron SK20-C1DT-D - Programmable Controller PLC Unit
  • Foxboro Eckardt (Schneider) AE214 - Field Indicator Digital Display Meter
  • Omron CJ1W-OD232 - Transistor Output Unit PLC Module
  • Jetter JX2-IO16 - Digital Input Output Module PLC
  • SEFI ACS 48.6A-NS - Power Supply Unit
  • Schneider (Telemecanique) XBTF011110 - Magelis Membrane Keyboard Overlay
  • Siemens 6ES5246-4UA41 - Simatic S5 Positioning Module
  • Siemens 6SL3120-2TE13-0AA3 - Sinamics S120 Dual Motor Module Inverter
  • SEW Eurodrive MAS51A005-503-50 - Movidyn Servo Drive Controller
  • Record ATE 20 - Automatic Door Brake Motor
  • Record ATE STA 21 - Automatic Door Brake Motor
  • Sanyo Denki R2AA06040FXP02 - AC Servo Motor
  • Omron NX-ID4442 - DC Digital Input Unit PLC Module
  • Schneider (Telemecanique) XBTGT2330 - Magelis Advanced Touch Panel HMI
  • ABB DX561-A1 - AC500 Digital Input Output PLC Module
  • SEW Eurodrive MC07B0004-2A3-4-00 - Movitrac B AC Frequency Inverter Drive
  • Schneider (Telemecanique) FT20CBCL030 - Connection Communication Cable
  • Visions AXFR 600601 - Gap Control Side Board PCBA
  • Allen Bradley 1797-CEC-A-C01 - Flex Ex Communication Interface Adapter
  • Siemens 6ES5095-8MC03 - Simatic S5 Programmable Controller CPU
  • Tectrol / Pitney Bowes TC53S-1392 - Power Supply Unit
  • Bronkhorst P-702C-FAC-88-Z - Digital Mass Flow Controller
  • Allen Bradley 1757-SRM - ControlLogix Redundancy Module
  • Neste 0635-107 - Control Board for SLX Automatic Sliding Door
  • RSF Elektronik MS 2x.x4 MO - Linear Encoder Sensor
  • Pro-face GP37W2-BG41-24V - Graphic Terminal Operator Panel HMI
  • Allen Bradley 2711P-RP1 - PanelView Plus Logic Module HMI
  • ABB (Asea Brown Boveri) GNT0144700R0004 - Power Supply Electronic Board Module
  • SEW Eurodrive MC-LTE-B-0008-2B1-1-40 - Movitrac LTE AC Frequency Inverter Drive
  • Siemens 3RK1301-0AB10-0AA4 - Direct Starter Modular Motor Starter
  • Yaskawa SGDB-15VD - Servopack Servo Drive Amplifier
  • National Instruments NI 9421 - 8-Channel C Series Digital Input Module
  • Yaskawa SGDB-10VD - Servopack Servo Drive Amplifier
  • National Instruments NI 9476 - 32-Channel C Series Source Digital Output Module
  • Pitney Bowes R782000 - Turbojet Controller Board PCBA
  • Lika IT65-Y-1000BND2 - Incremental Encoder Sensor
  • Came 002ZT6 - Control Panel Board for Gear Motors
  • Desin HS-300/7500 - Multivariable Process Controller Unit
  • Pilz PNOZ mc1p - Modular Safety Relay Controller
  • Innovative Robotics PTNR2-2-NES - Controller Interface Board Module
  • Schneider Electric (Telemecanique) TSXCB4020 - Printer Communication Link Cable
  • Wika IPT10 - Process Pressure Transmitter
  • Schneider Electric (Modicon) TSXDMF342A - Extension Digital Analog Module for TSX17 PLC
  • Omron F150-KP - Vision System Cursor Key Pack Console
  • National Instruments BNC-2110 - Shielded Connector Block Accessory
  • Bosch Rexroth (Indramat) CSH01.2C-SE-EN2-EN2-CCD-NN-S-FW - Servo Drive Control Panel Interface Module
  • GHM / Gefran / Baumer GHM510573A/1000 - Incremental Encoder Sensor
  • National Instruments NI 9425 - 32-Channel C Series Digital Input Module
  • Schneider (Telemecanique) STBDDO3705 - Digital Output Module STB
  • Siemens 6EP1436-1SH01 - Regulated Power Supply Unit
  • Schneider Electric (Modicon) TSXFPP20 - Fipway PCMCIA Communication Board
  • April QMB 3202 - PLC Output Card Module with Parameter Surveillance
  • Siemens 6ES5240-1AA12 - Simatic S5 Communication Processor Module
  • Midi Engineering MI907A - Stepper Motor Midi Amplifier Driver
  • Schneider Electric (Telemecanique) TSXAEZ414 - TSX Series Analog Input Module
  • Schneider (Telemecanique) TSX17-20 - TSX17 Compact PLC Controller Unit
  • Siemens 6ES5955-3LC14 - Simatic S5 Modular Power Supply Unit
  • Schneider (Telemecanique) ATV66U72N4 - Altivar 66 AC Frequency Inverter Drive
  • Omron NX-OD4256 - Transistor Output Unit PLC Module
  • Yaskawa / Omron SGDH-04AE-OY - Sigma II Servo Drive 400W
  • RSF Elektronik MS 20.04-2M - Linear Encoder Scale Sensor
  • ITT GMW (Metrosx) DAA288-240 A - LED Message Display Board
  • Allen Bradley 1757-SRM - ControlLogix Redundancy Module
  • Sensorex Alpha-LSE - Display Inclinometer Indicator
  • Omron NX-DA3603 - Analog Output Unit PLC Module
  • Grundig Electronic NRP 02 - Power Supply Control Unit Module
  • ProSoft Technology RLX-FHES-F - RadioLinx Industrial Wireless Hotspot Router
  • Omron NX-EIC202 - EtherCAT Coupler Unit PLC Module
  • Omron NX-TS3201 - Temperature Sensor Input Unit PLC Module
  • Omron CQM1-CPU41-V1 - Sysmac CQM1 PLC CPU System
  • April CPU5001 - PLC CPU Processing Unit
  • Yaskawa JZDP-D008-020-E - Linear Servo Motor Actuator
  • Bronkhorst P-702C-FAC-88-Z - Digital Mass Flow Controller
  • Allen Bradley 2711-K3A17L - PanelView 300 Operator Terminal HMI
  • Schneider (Telemecanique) TSXAEM411 - TSX Series Analog Input Module
  • Schneider Electric (Telemecanique) XBTGT5330 - Magelis Advanced Touch Panel HMI
  • Siemens 6ES5928-3UA12 - Simatic S5 Central Processing Unit PLC
  • Schneider (Telemecanique) TSXSUP65 - Power Supply Module
  • Schneider (Telemecanique) TSXLES61 + TSXLES60 - TSX Series Fine Line Box Local Module
  • Siemens 6SE6440-2AD23-0BA1 - Micromaster 440 AC Frequency Inverter Drive
  • National Instruments NI 9205 - 32-Channel C Series Analog Input Module
  • Yaskawa CIMR-PCC42P2 - Varispeed AC Frequency Inverter Drive
  • ABB PM554-T-A1 - AC500 PLC CPU Module
  • National Instruments cDAQ-9178 - 8-Slot CompactDAQ USB Chassis Backplane
  • Allen Bradley 1786-RPA - ControlNet Repeater Adapter Module
  • Allen Bradley 1770-KFD - DH-485 Communication Interface Module
  • Grundig Electronic NSP 02 - Power Supply Control Unit Module
  • Teq Q07.K3S.002A - Control Panel Logic Board
  • Allen Bradley 1300-ITSSC - Signal Converter Interface Module
  • Omron CQM1H-CPU51 - CQM1H Modular PLC System
  • ProSoft Technology 4207-DFNT-MCM - ProLinx Industrial Gateway Module
  • Schneider Electric TSXSCP114 - RS485 PCMCIA Communication Board
  • Grundig NGE 01 - Power Supply Unit
  • Grundig NZP 03 - Power Supply Unit
  • Siemens 6ES5246-4UA41 - Simatic S5 Positioning Module
  • Danaher / Atlas Copco / Socapel SAM-PA-400-30-E - Servo Power Supply Controller Unit
  • Klöckner Moeller EM4-101-DD1 - Easy Control Relay Module
  • Bosch Rexroth DKC-10.3-012-3-MGP-01VRS - Indramat Digital Servo Controller Drive
  • Schneider (Telemecanique) XBTGT2110 - Magelis Touch Panel HMI with Cutter
  • Berger Lahr (Sig Positec) WD3-004.1802 - Stepper Motor Controller Driver
  • ProSoft Technology MVI56-WA-EIP - ControlLogix Wireless EtherNet/IP Communication Module
  • Allen Bradley 1794-ACNR15 - Flex I/O ControlNet Adapter Module
  • Fanuc A06B-6096-H201 - Servo Amplifier Module
  • Panasonic MSDA083A1 - AC Servo Driver Amplifier
  • Teq Q07.K3P.003B - Control Panel Logic Board
  • Schneider (Telemecanique) XBTH002010 - Magelis Operator Terminal HMI
  • Wika IPT10 - Process Pressure Transmitter
  • Teq Q07.A4P.001A - Control Panel I/O Module Board
  • Teq Q07.A3L.003A - Control Panel Module I/O Board
  • Siemens 6ES5246-4UA31 - Simatic S5 Positioning Module
  • Mitsubishi / Harmonic Drive HC-KFS43 - AC Servo Motor with Harmonic Reducer
  • Mitsubishi HC-KFS43 - AC Servo Motor
  • SES Store Electronic Systems 37120/120 - VLF Radio Transmitter Label System
  • Siemens 6SE9213-6BA40 - Micromaster AC Frequency Inverter Drive
  • Rosemount 1151DP5S22 - Differential Pressure Transmitter
  • Siemens 6FM1470-4AA20 - Simatic FM 470 Positioning Module Processor
  • Yaskawa / Omron SGDM-01ADA - Sigma II Servo Drive 100W
  • ProSoft Technology RLX-IHW-E - RadioLinx Industrial Wireless Hotspot Router
  • Vickers / Moog BRM-4S-20A - Brushless Servo Motor Drive
  • Yaskawa JZDP-D008-019-E - Linear Servo Motor Actuator
  • Siemens 7MF4032-1DA00-1AA6-Z - Pressure Transmitter
  • Parker OEM770T - Stepper Servo Drive Controller
  • Schneider (Telemecanique) XBTPM027010 - Magelis Operator Panel HMI
  • Schneider Electric (Telemecanique) TSXSCM2214 - Communication Module PCMCIA Card
  • BeA (Bea) Flatscan SW - Laser Sensor Safety Detector for Doors
  • Siemens 6ES5240-1AA12 - Simatic S5 Communication Processor Module
  • Yaskawa / Omron SGDH-08AE-S - Sigma II Servo Drive