K-WANG



Product Overview
Product positioning: XSeries is divided into two product lines: XFC extended flow computer and XRC remote controller. This article focuses on three models of XFC dedicated to differential pressure measurement, which are equipped with XIMV integrated multivariable transmitters. A single unit can collect three sets of process parameters: differential pressure DP, static pressure SP, and medium temperature TF, and is compatible with various flow meters such as orifice plates, V-cones, turbines, and ultrasound for trade measurement.
Application scenarios: Unmanned metering stations in oil and gas fields and pipeline fields, supporting trade handover (compliant with API21.1), capable of single/multiple pipeline metering, powered by solar energy and battery DC low power consumption.
Configuration features: XIMV factory completes calibration, parameters are solidified in non-volatile memory, and the whole machine is customized according to needs before leaving the factory; The upper level adopts * * PCCU32 (Windows 32-bit) * * software configuration, calibration and debugging.
Differences in hardware configuration compared to the three models
1. Basic standard IO (unified across all models)
Comes with: 2 channels of 0-5V analog input, 2 channels of digital output, and 2 channels of configurable status input (DI/pulse cumulative PI multiplexing); Standard configuration includes 1 local debugging port and 2 modular communication ports (RS232/RS485 optional, with a maximum baud rate of 19.2k).
Hardware differences between two models
Model: Expandable TFIO Module Quantity: Built in Battery Maximum Capacity: Net Weight of the Whole Machine (Excluding Batteries)
XFC6410 cannot be equipped with IO module 26AH, approximately 6.13kg
XFC6413 up to 3 TFIO 26AH, approximately 6.8kg
XFC6713 up to 6 TFIO 42AH, approximately 13.1kg
3 TFIO expansion modules (modular hardware expansion)
Select IO cards as needed, the device automatically recognizes hardware and completes configuration. Optional modules include: 8-channel AI, 4-channel AO, 8-channel binary DI/DO/PI, 4-channel RTD, 4-channel thermocouple, valve control module, and multi protocol communication module (RS232/422/485).
4. Overall hardware architecture (taking XFC6413 as an example)
FC195 main control board+communication compartment+battery compartment+TFIO expansion slot+XIMV multivariable sensing unit; FC195 motherboard parameters:
Power supply: nominal 12VDC, supports 16-18VDC/solar charging;
Storage: 512K SR (lithium battery backup)+E2PROM (sensor calibration)+512K Flash program;
Peripherals: dedicated LCD screen, button interface, I2C expansion bus, dual level hardware password lock; Clock accuracy ± 7.5ppm.
5 XIMV integrated multivariable sensor core parameters (whole machine measurement core)
Measurement items: differential pressure DP, static pressure SP, medium temperature
DP/SP accuracy: ± 0.05% FS of range, ± 0.1% URL of annual stability, 71 ℃ temperature drift ≤ ± 0.15% FS;
Temperature measurement: -62~110 ℃, accuracy ± 0.56 ℃, standard 100 Ω platinum RTD, built-in automatic calibration;
AD conversion: nominal 16 bit, maximum 18 bit resolution; Anti vibration and installation tilt errors can be corrected by software.
Working temperature range: operation -29~60 ℃, storage -40~85 ℃.
6 Structure and environmental parameters
Shell: spray aluminum protective shell, wall mounted/pipe mounted/direct three installation methods;
Environment: Working -40 ℃~+85 ℃, humidity 0~95%, no condensation;
Explosion proof: CSA/NRTL Class I Zone 2 C/D group explosion-proof, ATEX Zone 2 pending certification;
EMC: Meets various RF anti-interference and transmission standards of EU EN, US FCC, ICES;
Electrical protection: reverse connection protection, surge/EMI filtering, PTC self recovery fuse, hot swappable protection, with a minimum power consumption of less than 100mW (8mA) for the entire machine.

Software modular design
Adopting an object-oriented modular architecture, software applications can be repeatedly instantiated on a single device, supporting parallel measurement of multiple pipelines, and built-in with a large number of standard measurement/control firmware:
Flow measurement category: AGA3/ISO5167 orifice plate, V-cone, AGA7 turbine/rotor, ultrasonic flow calculation method, compression coefficient NX19/AGA8 Gross/Detail calculation, in compliance with AGA3-85/92, AGA5 oil and gas measurement standards, and API21.1 trade handover specifications.
Functional applications: real-time trend recording, valve closed-loop control, alarm event RAMS, custom calculation, IEC61131 advanced logic, tank metering, calorific value master-slave accounting, and free switching of engineering units.
Communication Protocol: Native Totalflow low-power protocol, Modbus RTU/ASCII (master-slave), Enron Modbus, Square-D, Btu8000 and other protocols, supporting user-defined Modbus register mapping.
Core functions of the product
Data storage: default storage of 45 days/hour/day cumulative data and 200 event records, with user-defined storage duration; Power outages rely on onboard lithium batteries to maintain real-time clocks.
Alarm management: upper and lower limit monitoring, programmable filtering, abnormal event reporting.
Measurement guarantee: XIMV calibration maintains flow data, DP zero point programmable cutoff, temperature and pressure full compensation integration.
Security management: Double layer password permission protection to prevent parameter and measurement data tampering.
Power supply plan: Standard lead-acid battery, solar/external AC/DC charging options, suitable for outdoor scenarios without mains power.
Application and supporting facilities
The device can have a local optional display screen and operation buttons, and can be remotely networked through various buses; If you need to expand IO and communication, purchase the corresponding TF module. For detailed module specifications, refer to the original factory's 2101105~210112 series supporting materials.

K-JIANG
Add: Jimei North Road, Jimei District, Xiamen, Fujian, China
Tell:+86-15305925923