ADLINK NuDAM-6100 series DIN rail installation, RS-485 bus distributed IO module

From: | Author:Wang | Time :2026-08-18 | 84 visit: | 🔊 Click to read aloud ❚❚ ▶ | Share:


ADLINK NuDAM-6100 series DIN rail installation, RS-485 bus distributed IO module

Basic Information

General hardware specifications

Communication: Two wire RS-485; Baud rate 1200-115200bps; A single segment bus can have up to 256 nodes and a maximum distance of 1200m;

Power supply:+10~+30VDC non regulated DC;

Environment: Working temperature -10 ℃~70 ℃; Storage -40~85 ℃; Humidity 5-95% without condensation;

Dual watchdog: ① Module hardware watchdog (monitoring the operation of the module itself); ② Host Watchdog: When the upper computer fails or communication is disconnected, the module automatically switches the output to the preset safe value to ensure process safety.

Initiat configuration switch: Module hardware dip switch, turn ON (Init) to power on and enter default mode: Address 00, baud rate 9600, no checksum. Used to modify module address, baud rate, checksum, and communication protocol; Normal work must be switched back to Normal. The new version of the firmware supports software software's Initiat command, without the need to toggle hardware switches.

Protocol switching: By default, ASCII/Modbus RTU can be configured at the factory. After switching, the module needs to be restarted to take effect.


Module hardware list and hardware parameters

1. Module Overview

Model Channel Configuration Isolation Instructions

ND-6150 8-way isolated DI+8-way isolated open drain (P-MOSFET) DO 3750Vrms isolation, DO maximum 650mA per channel, with short-circuit protection

ND-6160 4-channel isolated DI+4-channel relay output; RL1/RL2 Form-A is normally open; RL3/RL4 Form-C conversion contact relay contact: 0.6A@125VAC  /  2A@30VDC

ND-6117 8-channel analog input; 6-differential+2-channel jumper differential/single ended isolation, supporting multiple voltage and current ranges

ND-6124 4-channel analog output (voltage/current configurable)+4-channel isolated DI; 14 bit DAC; Support output slope Slew Rate 3000VDC isolation, with independent configuration of each channel range

2. Mechanical structure

Dimensions: 142.2 × 71.55 × 100.7   mm; Supports DIN rail installation;

Terminal layout: power VS/GND, DATA+, DATA-RS-485 bus, Initiat switch, IO signal terminals;

Onboard Block Diagram: Provide complete internal schematic diagrams for ND-6150, ND-6160, ND-6117, and ND-6124, respectively;

Wiring diagram: Provide complete wiring diagrams for dry contact, wet contact DI, relay load, analog differential/single ended input, and AO voltage/current output.

System installation and initialization

3.1 Composition of the entire system

NuDAM-61xx IO module;

RS-232/USB to RS-485 converter;

+10-30VDC industrial power supply;

NuDAM-6100 Utility configuration software;

Engineering requirements for RS-485 bus: shielded twisted pair, 120 Ω terminal resistance at both ends of the bus; DATA+and DATA - polarity are unified across the entire network.

3.2 New module initialization process

The module is powered off, and Initialize is set to Initialize (ON); Power on and enter default state ID=009600 N-8-1;

The PC is connected to the module through an RS-485 converter; Use tools to scan modules;

Set the unique module address, baud rate, checksum and communication protocol (ASCII/Modbus ‑ RTU);

Power off, initiate to switch back to normal;

Connect to the on-site RS-485 bus and confirm that the baud rate and verification mode of the entire network are consistent.

Firmware D02.01 and above support software Initiate: send~AATnn to set timeout,~AAI to enable software Initiate, without the need to toggle hardware switches to modify parameters.

3.3 New modules added to existing networks

Initialization must be completed on a single machine first, setting addresses and baud rates that do not conflict with the existing network; Power off before connecting to the bus to avoid address conflicts.

3.4 Module Configuration Table

The manual provides baud rate codes, input range codes, data formats, AO output type codes, and Slew Rate code tables for various models.

ND-6117 AI: Supports ± 10V, ± 5V, ± 1V, ± 500mV, ± 150mV, -20~+20mA;

ND-6124 AO output types: 0-20mA, 4-20mA, 0~+10V, ± 10V, 0~+5V, ± 5V; slew rate can be configured from instant output to maximum 2048mA/s, 1024V/s.

NuDAM-6100 Utility Configuration Software

Running on the Windows platform, used for debugging and configuring modules.

Main functions: serial port parameter configuration, full network scanning module; Terminal emulator manually sends ASCII commands; Module parameter settings (address, baud rate, protocol, watchdog, power on output value, safety output value); Firmware ISP online upgrade.

Windows 7 and above will encounter runtime error 70 (permission denied). Solution: Control Panel - User Account Control UAC to lowest, restart the computer.

Readable/modifiable: module name, firmware version, watchdog parameters, power on output value, fail safe value; Simulate module calibration.


NuDAM ASCII Command Protocol

5.1 Command Common Format

Guidebook+Two digit hexadecimal address+Command+[Data]+[Optional checksum]+<CR (0x0D)>

Address: 00-FF; Broadcast Wildcard * *;

Response:! />Representing success;? Representing failure; Some broadcast commands (# * * synchronous sampling,~* * Host OK feeding dogs) have no response;

Checksum: Sum up all ASCII characters, modulo 0x100, enabled on high noise scenes.

5.2 Command Grouping

General configuration command (all modules)

%AANNTTCCFF sets module address, type, baud rate, and data format; Modifying the baud rate/checksum requires an Initiate state;

$AA2 reading module configuration; $AAF reads firmware version; AAM reading module model; ~AAO custom module name;

AAPN switches ASCII/Modbus RTU protocol; AAP reads the current protocol;

$AARS software restart module; AAS1 factory restoration; $AA5 reads the reset flag to determine if the module has been powered off and restarted.

DIO module (ND-6150/6160) command

#**Broadcast synchronous latch DI; $AA4 reads synchronous sampling;

$AA6/@ AA reads DI/DO status;

#AAxxxx sets DO output, supports single channel writing and batch writing;

Input latch function: can capture short pulses, AALS reads latch status, AAC clears latch;

~AACPSS modifies IO polarity logic.

ND-6117 Analog Input Command

#AA reads all channels AI; # AAN reads N single channel;

Support channel switch and independent setting of each channel range;

AA0 full-scale calibration Span; AA1 zero offset calibration.

ND-6124 Analog Output Command

#AAN (data) sets AO output, supports engineering units/complement hexadecimal;

$AA9NTTSS sets channel output type and slew rate Slew Rate;

Support reading actual read back output; Set default power on output value and watchdog fault safety output;

Support emergency DI: DI triggering can force AO to enter safe output.

Watch dog complete set of instructions (industrial safety focus)

~**Host feeding dog broadcast (no return), the upper computer must periodically send it;

~AA3EVV on/off host watchdog, set timeout (unit 0.1s, range 0.1-25.5s);

~AA2 reads watchdog configuration; ~AA0 reads watchdog timeout flag; ~AA1 clears timeout flag;

~AA5V stores the power on output value/watchdog fault safety value; ~AA4V reads the power on/safety output value.


Modbus RTU protocol support

Firmware D02.01 and above supports Modbus RTU, fixed frame format: 8 data bits, no checksum, 1 stop bit.

Supports standard Modbus function codes:

01 Read coil, 02 Read discrete input, 03 Read hold register, 04 Read input register;

Write single coil in 05 and single register in 06; 15 write multiple coils, 16 write multiple registers;

70 (0x46) Manufacturer customized read-write module parameters.

Register Mapping: The manual provides a complete mapping table of all coils, discrete inputs, input registers, and hold register addresses for ND-6150/6160 (DIO), ND-6117 (AI), and ND-6124 (AO).

Data format: Analog quantities support engineering unit format, binary complement format, and the manual comes with conversion formulas and complete read-write example messages.

Exception codes: including illegal functions, illegal addresses, illegal data, and watchdog timeout exceptions.


Appendix Important Function Description

Appendix A: Initialization switch: Hardware dialing operation steps. If the module parameters are forgotten, switch to Init and power on. Use address 00 to read the configuration. The new version supports software initialization.

Appendix B module status: power on reset, hardware watchdog reset, output jumps to power on value; The host watchdog timeout output jumps to a safe value, and a timeout flag is set. The command to clear the flag is required to restore the output.

Appendix C Dual Watchdog Mechanism

Module hardware watchdog: monitors the MCU of the monitoring module itself. If it crashes, the entire machine will be reset;

Host Watchdog: monitors the upper computer/communication link, outputs a safety value when timeout occurs, and prevents device loss of control.

Appendix D Reset Status Mark: Power on/Hardware Reset Position Mark; Clear the flag after reading $AA5 for the first time, which is used by the program to determine whether the module has restarted.

Appendix E Input Latch: DI channel hardware latch pulse signal, short pulses will not be lost; Command is required to clear the latch status.

Appendix F Power on Value/Safe Value

Power on value: output when the module is powered on/hardware reset;

Security value: The host watchdog will force output after timeout, and the user will save it in advance.

Appendix G Protocol Switching Steps: Switching ASCII/Modbus RTU in Initiate mode requires a restart to take effect.

Appendix H ND-6117 AI Calibration: Operating Procedure for Zero and Full Scale Calibration.

Appendix I ND-6124 AO Calibration: Voltage and current output zero/full-scale calibration requires a standard multimeter/milliampere meter, module preheating for 30 minutes, and factory calibration parameters can be restored.

  • Siemens 6SL3244-0SA01-1AA0 - SINAMICS G120 Control Unit
  • DANFOSS 175Z2688 - COATEDE CONTROLUNIT VLT5000
  • SIEMENS 6FM1721-3AA20 - Positioning Module
  • REXORTH VTS0605 PVAR S21 - Drive Module
  • BECKHOFF 2915-0000 - Control Module
  • COOPER EATON CGLine 400 40071347901 - CEAG CG Controller
  • SIEMENS 3UF5031-3AN00-1 - SIMOCODE DP Basic Unit
  • SIGMATEK DNC305 05-011-305 - Drive Controller
  • Multivac MV1 10249768 - Control Module
  • SCHNEIDER ELECTRIC MES114 59646 & 59645 - Circuit Breaker Accessory
  • CAMILLE BAUER CAPAX 44-580-0012 - Transmitter
  • HENGSTLER VT360P LS1/TOK - Encoder
  • BURKERT 8792 - 24V DC IP65 / IP67 Positioner
  • SENSOPART V10-OB-A1-W6 - Vision Sensor
  • ALLEN-BRADLEY 1762-L40BXB SER.C REV.J - MicroLogix 1200 Controller
  • HITACHI CPU22-02HC 33025801-2 - CPU Module
  • HITACHI AGH-0 33034810-2 - Control Board
  • PHILIPS AIH110 VER 1.0 - Control Module
  • BAUMULLER DO8000 - Drive Controller
  • B&R PS477 3PS477.9 Rev.C0 - Power Supply
  • ABB ALFA LAVAL 200-CISB - Communication Interface 2 x SatBus
  • Moeller MI4-570-TA1 - HMI Operator Panel
  • ABB ACH550-01-06A9-4+B055 - Variable Frequency Drive
  • ABB TPU2 3HNE00313-1 REV 12 - Teach Pendant Unit
  • Schneider Electric BRS368H130ABA - Stepper Motor
  • Foxboro FCM100E P0972ZA - I/A Series Communication Module
  • Siemens 6ES7 450-1AP00-0AE0 6ES7450-1AP00-0AE0 - Simatic S7 Version:04 Counter Module
  • Schneider Electric ATV320U07N4W - Altivar Machine Drive
  • Priva TouchPoint Flush V06:02 5060002 - Control Panel
  • Lenze ESMD402L4TXA - 4kW SMD Inverter Drive
  • Lenze ESMD402L4TXA - 4kW SMD Inverter Drive
  • Schneider Electric PM210 PM210MG - Powerlogic Power Meter
  • ASCOM U982-DB/1C U982 - Power Supply / Communication Module
  • DYADIC SYSTEMS SCN5-010-050-S03-NA - Servo Cylinder
  • Reliance Electric GMI-S04 - AC/AC CONVERTER 380/400V 50/60Hz 3.9/5.2A
  • Pro-Face GLC150-BG41-XY32KF-24V 3080060 PFXGLC150BDBP - Touch Screen HMI
  • ROFIN RSL TERMINAL V2 0185.01/03 - TERMINAL
  • HONEYWELL R7241E1077 - Burner Control / Amplifier
  • SEW MM22C-503-00 8241201 - 2.2kW Movimot Drive
  • Brand Digital III 50mL - Burette
  • Danfoss 195N0039 VLT2811PS2B20STR1DBF00A00C0 - 2.4kVA VLT Drive
  • SONY LG10-2 EK1 - Digital Gauge Indicator
  • EMERSON SKD3400750 - 7.5kW AC Drive
  • SIEMENS 6AV6 542-0AG10-0AX0 - MULTIPANEL HMI
  • TELEMECANIQUE ATV21HU55N4 - ALTIVAR21 5.5KW Variable Speed Drive
  • MITSUBISHI A985GOT-TBA-EU - GOT900 Touch Screen HMI
  • SCHNEIDER LXM32AD30N4 - Lexium 32 Servo Drive
  • SICK PSR01-1501 M20Z-02550A122 - Safety Laser Scanner
  • GECMA CHALLENGER 15-2-FMO - LITE TOUCH Monitor
  • Uniop EK02 6ZA982 - HMI Operator Panel
  • TELEMECANIQUE ATV18U54M2 - SQUARE D ALTIVAR 18 3kW Drive
  • Schneider Electric ATV312HU75S6 - 7.5kW Altivar 312 Drive
  • Siemens 6GK7243-5DX30-0XE0 6GK7 243-5DX30-0XE0 - Communications Processor
  • Schneider Electric LV432455 VIGI630 - 3POLE Earth Leakage Module
  • Rexroth PSI 6100.750 L1 R911170694-107 - frequency inverter / inverter
  • SWEDISH MICROWAVE AB Ku-Band BDC 138010-45-D0 - Block Downconverter
  • METTLER TOLEDO IND429 IND429-BB30 - Weighing Terminal
  • Siemens 6SL3210-5HE10-4UF0 - Sinamics V90 Servo Drive
  • B&R X20CP0482 Rev.D0 - X20 CPU Module
  • Mitsubishi FR-E720S-110SC-EC FRE720S110SCEC - 31A~11A Drive With Filter
  • ABB ACH580-01-026A-4 - Variable Frequency Drive
  • Siemens 6SL3210-1KE13-2AP1 - SINAMIC G120CDP 1.1kw Drive
  • Schneider Electric TM250D 4P3D LV431440 - Compact NSX250 Circuit Breaker
  • RELIANCE ELECTRIC GD.722.81.00-A 802288-74C - MAXITRON Servo Control Card
  • Uniop EK02 6ZA982 - HMI Operator Panel
  • Siemens 6SE9113-7JA13 - MICRO MASTER Junior 1.5kW Inverter
  • Mitsubishi FR-E720S-110SC-EC FRE720S110SCEC - 31A~11A Drive with Filter
  • Johnson Controls FEC2621 MS-FEC2621-0 - Field Equipment Controller
  • BENDER IR475LYT-429 - A-ISOMETER Insulation Monitor
  • Berger lahr D550 RS15 22.550-00-30b - Stepper Drive
  • Rexroth PSI 6100.750 L1 R911170694-107 - Frequency Inverter / INVERTER
  • KOYO 205 D2-06B-1 D2-240 H2-ECOM D2-08ND3 F2-08TRS - DIRECT LOGIC PLC WITH MODULE
  • TELEMECANIQUE ATV18U54M2 ATV18U54M - SQUARE D ALTIVAR 18 3kW Drive
  • Lenze 471-E1.D - Board / Controller Speed
  • Mitsubishi FR-A740-00038-EC - Frequency Inverter
  • Johnson Controls IOM3723 MS-IOM3723-0 - Input/Output Module
  • CURTIS 1238-5602 - AC Motor Controller
  • FOXBORO P0912XX REV.A - 220VAC Power Supply
  • Siemens 6SE9113-7JA13 - MICRO MASTER Junior 1.5kW Inverter
  • Mitsubishi FR-A740-00038-EC - Frequency Inverter
  • KOYO 205 D2-06B-1 D2-240 H2-ECOM D2-08ND3 F2-08TRS - DIRECT LOGIC PLC WITH MODULE
  • AUTZ M406D-00101 - Servo Motor
  • Lauer PCS095 PG095.508.BB - Operator Panel
  • ABB SCOP45SB/DX232 - SattCon OP45 SB Operator Panel
  • SEW Eurodrive MCH42A0030-5A3-4-00 MDX60A0030-5A3-4-00 - 4.8kVA Movidrive Inverter
  • BENDER IR475LYT-429 - A-ISOMETER Insulation Monitor
  • Johnson Controls FEC2621 MS-FEC2621-0 - Field Equipment Controller
  • Johnson Controls IOM3723 MS-IOM3723-0 - Input/Output Module
  • Berger lahr D550 RS15 22550-00-30b - Stepper Drive
  • SIEMENS 6FX1120-4BD03 6FX11204BD03 5702049304.00 E-Stand: A - Sinumerik Module
  • Allen-Bradley 1771-NIV B - HIGH RESOLUTION ISOLATED ANALOG SERIES Module
  • HONEYWELL XFC2D06001 - Flow Computer / Controller
  • Contraves Varidyn Compact ADB 380.90M - DC Drive 380v - 400v 90A 50kVA
  • Red Lion Control GEM52000 - Control Module
  • Siemens 6ES5 955-3NC13 - modular power supply TYPE:DIN41752
  • Danfoss ICV50 G20Mn50T / 027H5200 - Valve zaw
  • Eberle PLS508 P-814 / 2X EA-88 / A-812 / MT-81 / S-11 - PLC with Modules
  • Siemens 6ES7 314-6CF01-0AB0 6ES7314-6CF01-0AB0 - SIMATIC CPU314C-2 DP
  • EBERLE EM-525-87 EM52487 - ICE DETECTOR BASE UNIT
  • Telemecanique / Schneider TSXRKZ02 - TSX Micro automation plus 7module
  • B&R 5DLSDL.1001-00 - Display Link Receiver
  • Siemens 6FX1120-4BD03 6FX11204BD03 5702049304.00 E-Stand: A - Sinumerik Module
  • ALLEN-BRADLEY 1771-NIV A - HIGH RESOLUTION ISOLATED ANALOG SERIES Module
  • ALLEN-BRADLEY 1771-NIV B - HIGH RESOLUTION ISOLATED ANALOG SERIES Module
  • Contraves Varidyn Compact ADB 380.90M - DC Drive 380V - 400V 90A 50kVA
  • Contraves Varidyn Compact ADB 380.90M - DC Drive 380V - 400V 90A 50kVA
  • Ropex RES-202 - Resistron Temperature Controller
  • HONEYWELL XFC2D06001 - Flow Computer / Controller
  • Telemechanics ATV452U40 - DIMMER ALTIVAR5 SERIES 452 4kW 5HP Frequency Inverter
  • VEGA VEGAPLUS61 PS61.XXAGPHAMAX - Radar Level Sensor
  • BRANSON ULTRASONIC TRANSDUCER - Ultrasonic Transducer
  • Danfoss ICV50 G20Mn50T / 027H5200 - Valve Valvola Zaw
  • Schneider Electric 2001549/1 GALAXY PW 5102851200 NT07 - panler card
  • REXROTH VT3006-36 A - Proportional Valve Amplifier
  • Allen-Bradley 1746-OBP16 SERIES:C - SLC 500 OUTPUT MODULE
  • SCHNEIDER LXM32MD12N4 - Lexium 32 Servo Drive
  • Schneider Electric ATV630U22N4 - 2.2KW Altivar Process Drive
  • Allen-Bradley 1746-OBP16 SERIES:C - SLC 500 OUTPUT MODULE
  • Vanderlande 0E2550-00002... - Bagtrax Integrated Power Module 400V 32A
  • B&R X20CP0410 Rev.D0 - X20 CPU Module
  • VANDERLANDE 0E2550-00002 02EDD2B0100 - BAGTRAX Integrated Power Module 400V 32A
  • Rexroth R061205010 - Linear Bushing / Bearing
  • INDRAMAT TVM1.2-50-220/300-W0-220/380 - Power Supply Module
  • Vanderlande 0E2550-00002... - Bagtrax Integrated Power Module 400V 32A
  • HOMAG KEB 07F5S1A-YA00 09E5T60-1001 - Combivert Inverter WITH KEYPAID AND FILTER
  • Siemens 3RW3047-1BB14 - Soft Starter
  • Sumitomo AF-500 AF502-A40 - 0.4kW Transistor Inverter
  • Sumitomo AF-500 AF502-A40 - 0.4kW Transistor Inverter