K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

ADLINK PXES-2780 18 Slot PXI Express Chassis

From: | Author:Wang | Time :2026-08-21 | 4 visit: | 🔊 Click to read aloud ❚❚ | Share:

ADLINK PXES-2780 18 Slot PXI Express Chassis

Product Overview and Core Features

PXES-2780 complies with the PXI-5 Rev1.0 hardware specification, with a total of 18 slots for the entire machine:

Slot1: System controller slot; Slot10: System timed ST slot; 10 hybrid peripheral slots; 6 pure PXIe peripheral slots.

The hybrid slot is compatible with CompactPCI, PXI-1, CompactPCIe, and PXIe 3U modules; Pure PXIe slots only support PXIe/CPCIe modules.

Core Features

Configurable PCIe Gen2 switch backplane

Two working modes: factory default 4-link x4 (bandwidth balanced allocation); Optional 2-link x8 (providing higher single channel bandwidth for some modules); The overall system bandwidth is 8 GB/s; Partial slots have a maximum bandwidth of 4 GB/s per slot; After modifying the mode, it is necessary to restart the chassis to take effect.

Power supply: Industrial grade 800W AC power supply; AC input 100-240V; suitable for high-density multi module configuration.

Cooling system: 3 sets of 185.9 CFM rear fans; Bottom intake and rear exhaust; Single slot heat dissipation capacity of 38.2W at 55 ℃ environment; supports AUTO intelligent speed regulation/HIGH forced full speed; The backboard is equipped with 8 temperature sensors T1-T8, and the fan speed is adjusted based on the highest temperature of all sensors.

Advanced Synchronous Signal System

Global clock: PXI_CLK10 (10 MHz), PXIe_CLK100 (100 MHz); The rear panel BNC supports 10MHz external clock input and output; Clock priority: System timing ST slot input>Rear panel BNC>Chassis built-in clock; The backplane PLL can lock external 10M to generate synchronized 100M clock.

Star trigger: The Slot10 system timing slot provides single ended PXI_STAR and differential PXIe-DSTAR star trigger signals.

Segmented programmable bridge contact transmission bus: The trigger bus is divided into three sections: A (1-6 slots), B (7-12 slots), and C (13-18 slots); The software can independently configure the inter segment connectivity/isolation of each 8 trigger lines, supporting 8 topology combinations.

Local Bus: A single interconnected bus connecting adjacent slots.

Chassis intelligent monitoring (dual interface)

SMBus: Install Linghua embedded controller, which can fully read and write status, modify thresholds, configure PCIe links, and configure trigger bus bridging;

RS-232 DB9 serial port: External ordinary computers can only read status, set alarm thresholds, and cannot modify PCIe links or trigger bridge configurations;

Monitoring objects: various power supply voltages, 8-channel backplane temperatures, and 3-channel fan speeds; Three color LED alarm on the front panel; Support remote INHIBIT power on/off.

Form: desktop/rack dual-use; Net weight 11.9 kg; working temperature 0-55 ℃.

Hardware specification parameters

1. Power parameters

AC input: 100-240 VAC, 50-60 Hz, maximum input 1200W; DC total available power 800W

Table

Output rail maximum current load regulation ripple noise

+5V 29.0A ±5% 50 mV

+12V 45.0A ‑ 120 mV

+3.3V 60.0A ‑ 50 mV

-12V 2.5A ‑ 120 mV

2. Clock indicators

PXI_CLK10: maximum inter slot offset of 300 ps; onboard clock accuracy ± 25 ppm;

PXIe_CLK100: maximum inter slot offset of 100 ps, accuracy ± 25 ppm;

BNC external input: 100   mVpp~5   Vpp, 50 Ω input impedance.

3. Heat dissipation and noise

Fan: 3 × 185.9 CFM; Bottom intake, rear exhaust;

Single slot heat dissipation: 38.2   W (verified at 55 ℃);

Noise: AUTO mode ≤ 46.3 dBA; HIGH full speed 64.5 dBA;

Rack ventilation: Bottom air inlet ≥ 44.5mm (1U); The rear air outlet must be ≥ 76.2mm; the vacant slot must be equipped with a filling baffle.

4. Mechanical parameters

Dimensions: 464.3   mm (width) × 191.4   mm (height) × 465.3   mm (depth)

Net weight: 11.9   kg

5. Environment and Certification

Working temperature 0-55 ℃; Storage -20~70 ℃; Humidity 10-90% RH without condensation;

Impact 30G half sine wave; Random vibration;

Safety EN61010-1; EMC Class‑A; CE certification.

6. Explanation of Backboard Slot Position

Slot1 system slot: supports embedded controllers with a maximum slot width of 4 slots;

Slot10 system timed ST slot: output star trigger; Can be used as a regular PXIe peripheral slot without star triggering;

Slot2‑9、 11-18: 10 mixing tanks+6 pure PXIe tanks; Some of the slots support PCIe x8 links.


Panel interface, indicator lights

front panel

Power button A; only valid when the back panel INHIBIT switch is in the DEF position;

Tri color status LED B (from left to right)

Amber Temperature: extinguished normally; Flashing any temperature sensor exceeding the default threshold of 70 ℃;

Green Fan: The fan is always on and functioning normally; Flashing fan speed below 800 RPM;

Blue Power: Always on, power supply is normal; Flashing any power rail voltage exceeding the ± 5% threshold.

Rear panel interface (emphasis)

BNC: 10MHz REF IN external clock input; 10MHz REF OUT clock output;

DB9-1 (Remote Monitoring) RS-232 serial port: external computer serial port monitoring (only reads status, sets threshold, cannot configure trigger bridge/PCIe link);

DB9-2 (Inhibit/Voltage Mon): Remote INHIBIT power on/off pin, which can directly lead out multiple DC voltages for multimeter measurement;

INHIBIT switch: DEF=front panel button control; MAN=remote control of power on/off by the INHIBIT pin of DB9;

Fan mode switch: AUTO automatic speed regulation/HIGH forced full speed;

C19 high-power AC power input port; Chassis grounding pole.

Note that RS-232 is for cross transmission and reception, and the cable needs to be Rx Tx crossed.

Packing list, hardware and rack installation

4.1 Packaging List

PXES-2780 chassis, power cord;

Fill baffle kit (1 3-channel baffle, 18 single slot baffles);

ADLINK All in One CD (monitoring software, drivers, manuals);

The rack installation kit is an optional item.

4.2 Hardware module installation

System Controller Slot1: Confirm that the CPU, memory, and storage of the controller have been assembled; Release the lock buckle, slide along the guide rail into the slot, fasten the lock buckle, and tighten the panel screws; Recommend pairing with Linghua PXIe-3975 controller;

Peripheral module Slot2-18: Release the module latch, slide into the idle slot, fasten the latch, and tighten the screw; Idle slots must be equipped with filling baffles; It is strictly prohibited to hot plug modules, and the entire machine must be powered off for plugging and unplugging.

4.3 Rack Installation

Remove the handle on the right side of the chassis and remove the bottom rubber foot pad;

Install and select rack brackets; The bracket hole supports front and rear depth adjustment, allowing the chassis to be retracted towards the interior of the cabinet, leaving space for front cables and Mass Interconnect components;

Secure the bracket to the standard cabinet using screws; The installation of the rack must ensure a ventilation gap at the bottom air inlet.

4.4 Startup

Connect the C19 AC power cord properly; Confirm that the INHIBIT switch is set to DEF;

Press the power button on the front panel, and the blue Power LED will light up.


System monitoring software PXES-2780 Chassis Remote Mon. Utility

The software runs on the Windows system; Comparison of two sets of communication interface capabilities

Table

Function SMBus (controller internal bus) RS-232 serial port (external PC)

Read the status of the chassis (voltage, temperature, fan speed) ✅ Support ✅ Support

Modify alarm threshold ✅ Support ✅ Support

Configure segmented trigger bus bridge routing ✅ Support ❌ not supported

Switch PCIe link mode (4-link x4/2-link x8) ✅ Support ❌ not supported

The software interface is divided into three modules: Connect Control, Remote Status&Control, and Chassis Status.

Connect Control

Choose SMBus or RS232 serial port; The serial port baud rate is fixed at 9600;

Chassis status log: Custom sampling period, log supports overwrite/append saving;

Threshold configuration: Save, load, and restore factory alarm configuration; Read MCU, FPGA, and backplane firmware versions.

Remote Status&Control (Chassis Control and Threshold Setting)

Trigger Bus configuration: software graphical interface, with 8 trigger lines independently configured to connect/isolate three sections A/B/C, and the configuration can save templates;

PXIe Link: Switch between 4-link x4/2-link x8 mode, and the modification will take effect after restarting the chassis;

Target Temperature: AUTO mode fan speed control logic: all sensors<25 ℃, fan duty cycle 40%; Linear acceleration starts when the temperature exceeds 25 ℃; The fan reaches the set target temperature at 100% full speed; The target temperature can be adjusted within the range of 25-70 ℃;

Fan Speed: The software can also switch between AUTO/Full full speed;

Alarm Threshold: Set the alarm thresholds for each DC voltage, temperature, and fan speed.

Chassis Status

Real time reading of all power rail voltages;

T1-T8, a total of 8 backplane temperatures;

3 fan speeds; Each parameter displays normal/abnormal status.


Troubleshooting and basic maintenance

Common fault phenomena

The whole machine is not powered on: confirm the C19 power cord and socket; Confirm that the INHIBIT switch on the rear panel is in DEF;

Power blue LED flashing: One power rail voltage exceeds the limit; Unplug all modules and retry; Continuously contact the manufacturer for the malfunction;

Fan green LED flashing: The fan is obstructed by foreign objects or the fan hardware is faulty;

Temperature amber LED flashing: Check the ventilation of the bottom air inlet and rear air outlet; Confirm that all empty slots are filled with baffles; If the ventilation conditions are intact and still alarm, contact the service provider;

System startup failure: Remove all peripheral modules, insert them one by one, and locate the faulty module.

Maintenance points

Net weight of the chassis is 11.9   kg; use chassis handles for handling to prevent injury;

Before maintenance and cleaning, be sure to turn off the power and unplug the AC power cord; Focus on cleaning the dust at the air inlet;

Internal maintenance must be operated by authorized technicians;

Built in backup lithium battery, there is a risk of explosion if the wrong model is replaced.


Safety instructions and technical support

Indoor use only; Maximum working altitude of 2000 meters; Pollution level PD2;

Before disassembling or plugging modules, the AC power supply must be completely disconnected; Prohibit blocking ventilation holes; Stay away from liquids, high temperature and humidity;

After the equipment is working, the temperature of the casing is high, which poses a risk of burns. It should be touched after cooling down.

  • SMC C96ST80-600 - Pneumatic Cylinder 80mm Bore 600 Stroke
  • MOORE INDUSTRIES AIM/IO/AI4/IP - Analog Input Module
  • IMAI ELECTRIC NBS-200S-2XSET - SMALL TRANSFORMER
  • FCI OEM-019469-04-02 - Flanged Inline Flow Transmitter
  • FAGOR EC-9PA-DQ1-M - CABLES NEW
  • FAGOR EC-9AM-MB - CABLES NEW
  • ATLAS COPCO LUM22 SR4 - Pneumatic Screwdriver
  • REXROTH HE751863 - VALVE NEW
  • SANYO SDNM-MCA - SERVO DRIVE
  • EGS WTC 303-1761 - TRANSFORMER
  • SQUARE D H362 - Heavy Duty Safety Switch
  • ALLEN BRADLEY 140G-J-FCX04 - Operating Mechanism 250A J Frame
  • GRACO 24E451 - Teach Pendant 120VDC NEW
  • RITTAL SK3125 - AIR/WATER HEAT EXCHANGER 5120BTU 115V/230V
  • FESTO DF00A - Guided Pneumatic Cylinder
  • SMC CDG1BA20-4050-H7B3-XC10 - Pneumatic Cylinder
  • FUJI FKCT33U5AXCYYAA - Differential Pressure Transmitter NEW
  • Allen Bradley 440E-A13082 - Guardmaster Rope Pull Accessory Kit (20m) NEW
  • LECO RT-120-A 1986 - Hardness Test Block Kit AS-IS
  • BALLUFF BCC A313-A313-30-345-VX43W6-300 - Industrial Connecting Cable BCC0HZ8 NEW
  • SIEMENS 6SN1162-0BA02-0AA2 - SINAMICS Cooling Fan Motor Assembly
  • GC VALVES S211YF02N1GJ5 - Solenoid Valve NEW
  • BALLUFF BNI EIP-302-105-R015 - DIGITAL I/O
  • STI RM-3-HA1 - MUTE MODULE
  • ALLEN BRADLEY 284-PWRM29A-M4 - ArmorConnect 3PH Pwr Media Shld Mtr Cbl NEW
  • BALLUFF BNI008A - LED STACK LIGHT
  • Grossenbacher LG-NR.50 70 73 - CIRCUIT BOARD NEW
  • Keyence XG-H1XA V3.1 - Vision System Software DVD NEW
  • IFM GM705S - Inductive Safety Sensor NEW
  • SIEMENS 3RK1207BQ40AA3 - Analog Input Module NEW
  • NACHI 32-O1O15457 - PCB-CONTROL BOARD
  • NACHI 30-OOO17198 - PCB CONTROL BOARD
  • PILZ PU3Z - Safety Control Power Supply / Safety Power Monitoring Unit NEW
  • ICC FR-A7N-ETH - Ethernet Multiprotocol Communication Interface NEW
  • KUKA ESC13 V1.60 A161.00.005.571 - Control PCB Board
  • SMC CP96SDB80-50C - Pneumatic Air Cylinder 80mm Bore 50mm Stroke
  • BRAD CONNECTIVITY 1300062619 - Minihange Cordset 5in 6 m NEW
  • REXNORD P3U239N - PILLOW BLOCK BEARING 2-7/16" BORE NEW
  • REXROTH 0083040 KE310 - Control Interface Module
  • FAG B7206-C-2RSD-T-P4S-UL - HIGH PRECISION BEARING NEW
  • MEMTRON 3512160 - OPERATOR INTERFACE PANEL
  • CUTLERAMMER DH361FGK - Heavy Duty Safety Switch
  • ALLEN BRADLEY 160-BA03PPS1P1 - AC Drive
  • SMC MDNBL50-50-D-A54SDPC - Pneumatic Cylinder
  • MISUMI HFTANK8-4040 - ANCHOR STANDS SET OF 2 NEW
  • ALLEN BRADLEY 442G-MABH-L - Guardmaster Handle Assembly NEW
  • ALLEN BRADLEY 442G-MABH-R - Guardmaster Handle Assembly NEW
  • HARDINGE T18 58 - RECESS TOOL NEW
  • MITSUBISHI 0SA105S5A - ABSOLUTE POSITION ENCODER
  • FANUC A20B-8101-0550 - PC BOARD COMMUNICATION INTERFACE MODULE
  • FESTO EMMB-AS-60-04-S30S - SERVO MOTOR
  • SIEMENS 6AV2123-2JB03-0AX0 - KTP900 Basic HMI Touch Panel
  • BALLUFF BCC A314-A314-30-304-VX44W6-250 - Industrial Connecting Cable BCC0CE3 NEW
  • SIEMENS 6SL3130-6AE15-0AB1 - SINAMICS Smart Line Module 5kW
  • SIEMENS 6FX8002-2EQ10-1BF0 - Signal Cable (15m) NEW
  • SMC AMG550C10D - Water Separator 1" NPT NEW
  • MINARIK DRIVES MM23002D - DC Motor Speed Control NEW
  • SMC AMG550C-N10D - Water Separator 1" NPT NEW
  • PROACE 28800452 - Operator Interface HMI
  • GEHRING 254000 - Industrial Control Interface Module - Missing Terminal
  • GEHRING 254000 - Industrial Control Interface Module - Missing Terminals
  • SIEMENS 3RT1044-1QB44-3MA0 - Contactor 24V NEW
  • SMC CDQ2B50-25DZ-J79W-111G - COMPACT CYLINDER NEW
  • TURCK FDNL-CSG88-W - DeviceNet I/O Block 8-Port Field Module NEW
  • BOSCH REXROTH R900773654 4WE10D40/CW110N9DAL - Directional Control Valve
  • GOULD 68173 - Power Distribution Block 3 Pole 600V CU ONLY NEW
  • INSTRON 2512-228 - Compression Load Cell 100 lb / 500 N
  • RITTAL SZ 4138.350 - Enclosure System Light 230V 30W NEW
  • BALLUFF BNI00CJ - IO-LINK SENSOR ACTUATOR HUB NEW
  • Cutlerammer DH362FGK - Heavy Duty Safety Switch
  • SMC CA2F63TF-400Z - Pneumatic Air Cylinder NEW
  • FCI OEM-019868-04-02 - FLOW SWITCH STAINLESS SENSOR
  • RADEROGEL 5450 0325 00 - Polyurethane Wheel 10" Dia w/Cast Iron Hub - NEW
  • LAMINA G516325UG - NAAMS Guide Pin 63mm x 250mm Unground
  • GEHRING 254000 - Industrial Control Interface Module
  • CINCINNATI MILACRON 3-424-1954A - Blower Unit
  • TURCK FDNP-50808G-TT - DeviceNet I/O Module 8DI 8DO 0.5A NEW
  • EASOM ES-5008-12-DC-024 - Digi-Dog Programmable Limit Switch
  • ALLEN BRADLEY 140G-H2F3-C80 - Molded Case Circuit Breaker 400V 80A Ser. A NEW
  • AUTOMATION SYSTEMS INTERCONNECT P7007-ASI - Safety Foot Switch NEW (Lot of 2)
  • BAHCO COBRA 38517.9/8 - Bandsaw Blade 153 in NEW
  • NSK LY350595BLC2W03P44 - LINEAR GUIDE NEW
  • KEYARROW F46295001-HT03-A5 - CNC Machine Cover
  • INSTRON 2512-144 - TENSION LOAD CELL NEW
  • TELEMECANIQUE GS1U - Fused Switchisconnector
  • SMC TU0805BU-100 - POLYURETHANE TUBING 100M NEW
  • SIEMENS 6SL3210-5HE11-5UF0 - SINAMICS S210 SERVO DRIVE
  • FANUC A20B900161/04A - Flash Memory Module
  • REXROTH INTERBUS-S - SENSORS NEW
  • ANDERSON GREENWOOD CROSBY 951200FFA-P - PILOT OPERATED SAFETY RELIEF VALVE
  • SMC C96SB80-80C - Pneumatic Air Cylinder 80mm Bore 80mm Stroke
  • ATLAS COPCO 4220 1566 80 - Factory Repaired Motor NEW
  • Allen Bradley 440E-D2NNNYS - Guardmaster Lifeline 3 Rope Pull Switch NEW
  • ABB DSQC30 3E 041456 - Robot Control Board
  • SMC CP96SDB1000C - ISO 15552 Pneumatic Cylinder 100mm Bore 50mm Stroke NEW
  • GLOBAL CNC 523032 - 1/4" ID Dual Coolant VDI Static Tool Holder NEW
  • OHM ELECTRIC OC-15 - BOXFAN
  • OMEGA RD202 - CHART ENCODER
  • FANUC A16B-2203-0370 /07C - PCB - Power Supply Unit
  • FANUC A20B-8002-0050/01A - PCB - Genius I/F Module
  • SUPERFLEX 20638/CBL - FLEXIBLE MULTI-CONDUCTOR CABLE
  • SIEMENS CU320P - Sinamics Control Unit PROFIBUS
  • NORDSON 7022004 - DISPENSE VALVEMATE 8000 CONTROLLER
  • OKUMA 1911-3380-0847001 - PLC POWER CONTROLLER MODULE
  • ABB NAMU1C 64702475D - AUXILIARY MEASURING UNIT
  • HONEYWELL 24CE1 - Limit Switch NEW
  • YASKAWA SGDA-08ASP - SERVO CONTROL NEW WITH BOX
  • PARKER WDHC-H-SD50-248-YF2P-03YB165 - PNEUMATIC CYLINDER
  • SANYO SDN-DR1-025 - SERVO DRIVE
  • SMC C96SDB80-25C - ISO Pneumatic Cylinder 80mm Bore 25mm Stroke
  • SMARTEYE SP1056/01 - Infrared Sensor Emitter
  • SMC CNA23DA - 63m Power Lock Cylinder
  • CUTLERAMMER 1492D96G11 - Motor Circuit Protector
  • ELECTRO-MATIC EMRP30014-E30 - Remote Port Access Panel NEW
  • ATHENA T2000-J-S-316-4-G-24-75-0 - Probe
  • PRO-FACE GP577R-TC41-24VP - 10.5 Inch Color TFT HMI Operator Panel
  • DOMINO EPT064422 - Print Head Mount Kit NEW
  • FANUC A06B-0532-B001#7000 - SERVO MOTOR
  • Rexroth 0 608 750 109-GB1 VM310 - Power Module
  • FANUC CFDA-0WPB-0030-AAB - CABLES NEW
  • ALLEN BRADLEY 280-PWRM35A-M10 - POWER CABLE
  • FANUC A16B-3200-0412/03A - Control Module Board
  • BALLUFF BCC A314-A314-30-304-VX44W6-300 - Industrial Connecting Cable BCC0CEE NEW
  • Adept Technology 20000-310 - CX Robot Motion SmartController
  • ADVANCE 71A8473-001D - 400W HPS Ballast Kit 120-277V NEW
  • SMC NCA1F250400 - Heavyuty Pneumatic Cylinder NEW
  • IAI SCON-CB-100WAI-EP-0-2-SP - POSITION CONTROLLER
  • MURR ELEKTRONIK MVK+MPNIO DI8 DO8 IRT - PROFINET I/O Module