ADLINK cPCI-6910 series 6U CompactPCI single board computer

From: | Author:Wang | Time :2026-07-21 | 97 visit: | 🔊 Click to read aloud ❚❚ | Share:

ADLINK cPCI-6910 series 6U CompactPCI single board computer

Chapter 1 Product Introduction (Product Positioning, Model, Hardware Block Diagram, Packaging)

product positioning

Single slot 4HP standard 6U cPCI controller, equipped with dual core low-power Xeon LV/ULV 65nm processor, using Intel E7520 server level chipset, supporting PCIe high-speed bus, four gigabit network, multi type storage, compatible with system slot/peripheral slot, supporting hot plugging, matched with two RTM rear IO expansion cards, suitable for telecommunications switches, military measurement and control, and server blade devices.

Differentiation of hardware models across the entire series

Motherboard model (distinguishing between CPU and onboard memory)

CPCI-6910/DCX20/M1G: LV 2.0GHz dual core Xeon, 1GB soldered ECC DDR2

CPCI-6910/DCX20/M2G: LV 2.0GHz dual core Xeon, 2GB soldered ECC DDR2

CPCI-6910/DCX16/M1G: ULV 1.66GHz dual core Xeon, 1GB memory

CPCI-6910/DCX16/M2G: ULV 1.66GHz dual core Xeon, 2GB memory

CPCI-6910/DXL16/M1G: LV 1.66GHz dual core Xeon, 1GB memory

CPCI-6910/DXL16/M2G: LV 1.66GHz dual core Xeon, 2GB memory

Differences between two RTM rear adapter plates

CPCI-R6910: Equipped with LSI SAS controller, supports SAS/SATA hard drives, without SCSI

CPCI-R6911: Equipped with LSI Ultra320 SCSI controller, supporting RAID0/1 array, and equipped with 68 pin SCSI interface

Factory packaging accessories

Motherboard kit: cPCI-6910 body, CPU heat dissipation kit, SATA/IDE/CF adapter card, PS/2 one/two wire, RJ45 to DB9 serial cable, driver CD, paper manual

RTM kit: corresponding adapter board body, supporting storage cables (SAS/SATA/CSIS), hard disk mounting bracket

Optional: CF card adapter module, additional storage daughter card

Basic Core Highlights

Single channel dual core low-power Xeon, 667MHz front-end bus, 2MB on-chip L2 cache

ECC soldered DDR2 memory, up to 2GB, hardware data correction

4-port Gigabit Ethernet (front 2+back 2, PCIe x4 channels), supporting PICMG2.16 packet switching backplane

Onboard PMC expansion slot, dual serial ports, 4-channel USB 2.0, VGA display

Multi storage compatibility: IDE/SATA/CF; RTM optional SAS/Ultrara320 SCSI array

Integrated IPMI v1.5 substrate management, two-level hardware watchdog, hardware voltage and temperature monitoring

Full PICMG standard compatibility: 2.0 hot swappable, 2.16 packet switching, 2.9 IPMI management bus


Chapter 2: Complete Hardware Specifications and Power Consumption Data

CPCI-6910 motherboard core specifications

Mechanical standard: 6U 4HP cPCI, size 233.35 × 160mm; supports chassis hot plugging, front pop-up handle controls power on enumeration signal

CPU: 478 pin micro FCPGA slot, single core Xeon LV/ULV (1.66/2.0GHz), 65nm process, CMP dual core architecture, intelligent power regulation

Chipset: Intel E7520 Northbridge+6300ESB Southbridge, supports PCIe x8 split multiplexing x4, HI1.5 high-speed bridging bus

Memory: Onboard soldered dual channel 72 bit ECC DDR2 400, fixed 1/2GB, hardware SEC/DED memory error correction, supports memory mirroring

Graphics: ATI ES1000 2D graphics card, PCI 32-bit bus, up to 24 bit color, industrial stable output

Network: Dual Intel 82571EB Gigabit Controller, PCIe x4, A total of 4 gigabit channels (front 2, RTM rear 2), with the ability to switch between backplane PICMG2.16 or rear RJ45 via dial-up

Storage Controller

Nanqiao Integrated Dual UltraATA10 IDE Channels (Mainboard Main Channel, RTM Sub Channel)

Two onboard SATA ports, led out to RTM through J3 backplane

Peripheral bus

4-channel USB 2.0 (front 2, rear 2), EHCI+UHCI dual controllers, supporting USB device boot

Two 16550 compatible serial ports: COM1 front, COM2 rear RTM, SWZ2 dial-up switch serial/IPMI management mode

PMC 64bit/66MHz expansion slot (J4 backplane)

PLX PCI-6540 PCI-X bridge, supporting transparent/non transparent working modes, can be used as an independent intelligent subsystem

BIOS:4MB Phoenix-Award Flash, Write protection switch, supports USB boot, PXE diskless, serial remote console, SpeedStep energy-saving

IPMI BMC: ATmega128L management chip, IPMI v1.5, Independent 128KB firmware Flash, capable of reading hardware sensors and remote power on/off when powered off

Environment and Certification: Work requires 30CFM forced air cooling, CE/FCC A-level industrial certification

Comparison of two RTM adapter board specifications

Parameter cPCI-R6910 cPCI-R6911

Storage controller LSI SAS1064E LSI Ultra320 SCSI 53C1020

The array supports SAS pass through, no hardware RAID RAID0 stripe/RAID1 mirroring

Rear interface COM2, 2USB2.0, 2 Gigabit RJ45, CF, SAS/SATA COM2, 2USB2.0, 2 Gigabit RJ45, CF, 40pin IDE, 68 pin SCSI

Backplane channel RJ3/RJ4/RJ5 cPCI standard connector RJ3/RJ4/RJ5 cPCI standard connector

IO Resource Comparison Table

Distinguish between motherboard front end, motherboard onboard, two RTM rear end/onboard all serial ports USB、 Network port, storage, PMC, VGA resources, clearly distinguish detachable daughter card interfaces.

Tested power consumption under different operating conditions (ULV1.66/LV1.66/LV2.0 CPUs)

Test environment: 2GB ECC memory, SATA 80GB hard drive, 350W industrial power supply

DOS standby: ULV minimum 27.5W, LV2.0 maximum 33.5W

Linux standby: range of 24.8~27.6W

Windows XP full load (100% CPU): 39.5W~48.5W

Windows XP idle: 24.5~26W

Provide current and power details by dividing the voltage into two channels, 3.3V/5V.


Chapter 3: In Depth Explanation of Hardware Functions

Disassemble the motherboard chip and peripherals module by module. Working principle:

Processor: Dual core CMP architecture, prefetching mechanism, dynamic power throttling, SpeedStep energy-saving

E7520 North Bridge: Three PCIe x8 channels, can be split into multiple x4, DDR2 memory controller, ODT on-chip termination, hardware memory failure redundancy

6300ESB South Bridge: Integrated SATA/IDE/USB/serial port/two-level watchdog/ACPI/APIC interrupt, SMBus management bus

PCIe bus: bidirectional 5Gbps bandwidth per channel, hardware hot plugging, CRC link verification, automatic link retraining

Storage system: UltraATA10 dual IDE, SATA1.5G, distinguishing between motherboard local storage and RTM extended storage

USB 2.0 EHCI high-speed+UHCI low-speed, supports USB keyboard and mouse boot under DOS/BIOS, overcurrent detection

UART serial port: standard 16550, hardware flow control, COM2 can be reused as IPMI management serial port

Two level watchdog WDT (integrated in 6300ESB)

Two stage countdown: In the first stage, an IRQ interrupt is triggered when the timeout occurs, and in the second stage, the hardware is reset when the timeout occurs

Timing accuracy in two levels: 1 μ s~1s/1ms~10min; Support free running mode

Supporting GPIO control WDT alarm indicator light, system reset pin

ATI ES1000 graphics card: pure 2D industrial acceleration, compatible with servers without displays, remote serial port operation and maintenance

PLX PCI-X bridge: dual-mode switching, system slot transparent bridge, peripheral slot non transparent independent bus isolation

Hardware monitoring IT8712F: Real time collection of CPU/motherboard temperature, 3.3V/5V/12V voltage, threshold alarm

Chapter 4: Full Definition of Connectors, Layout, and DIP Switches

Overall layout of motherboard

Label the positions of CPU, E7520 North Bridge, 6300ESB South Bridge, ATI graphics card, PMC slot, memory array, J1-J5 cPCI backplane gold finger, and all components on the front panel.

Front panel IO and status LED

Exposed interfaces: VGA, PS/2 composite port COM1、 Dual USB, 2 Gigabit RJ45, reset button

Definition of indicator lights: power yellow light, hard disk read/write red light, watchdog amber alarm light, hot swappable blue ready light

Removable storage daughter card

DB-6910IDE (2.5-inch IDE), DB-6910SAT (SATA), DB-6910CF (CF card) three adapter board drawings, board to board connector pins.

R6910/R6911 adapter board layout

Display two RTM onboard SAS/CSIS controllers CF、IDE、 Board to board backplane connectors, rear panel serial/USB/Ethernet/SCSI/SAS interface drawings.

Standard definition of all interface pins

Complete list of USB, RJ45 Gigabit Ethernet, VGA DB15, PS/2, COM DB9, CF card, SATA/SAS board to board connector, cPCI J1/J2/J3/J4/J5 five groups of backplane gold finger all pin signal, power, and ground allocation.

Dial switch function (core configuration switch)

SWZ1: Clear CMOS button, power off and press to reset BIOS

SWZ2: 4-digit dialing, switch between COM2 normal serial port/IPMI management serial port (factory default COM mode)

SW1 motherboard 4-digit debugging switch: distinguish between B2 old version/B3 new version PCB definitions, control pre charging, system slot identification, and debugging functions

RTM side SWY series dial-up (R6910/SWZ; R6911/SWY): controls whether the rear gigabit network is connected to the backplane PICMG2.16 or the rear RJ45, all ON enable the rear network port, all OFF go to the backplane

R6911 SWY5: Set CF card IDE master/slave mode


Chapter 5 Hardware Step by Step Installation Tutorial (Anti static Mandatory Pre installation)

Pre specification: Full process anti-static wristband, anti-static workbench, prohibit bare hands from touching the chip slot

Installation tools: Phillips/Phillips screwdriver, hexagonal socket (hard drive bracket)

CPU installation steps

Rotate to unlock the slot lock, lift the pressure plate, and remove the protective cover

Align the CPU triangle positioning mark with the slot and place it flat without pressing

Buckle the pressure plate and secure it with locking screws

Installation of heat dissipation module

Tear off the CPU/Northbridge thermal protection film

Align the radiator with the positioning column and tighten the four screws diagonally in steps to ensure that the thermal pad is fully attached

Storage device installation (motherboard/RTM dual path)

Local 2.5-inch IDE/SATA hard drive on motherboard: Install copper pillar → Secure adapter card → Vertical buckle board to board connector screw locking

RTM side SAS/SATA hard drive: equipped with SAS daughter card assembly and bracket fixation

CF card module: Install CF adapter board, protective bracket, vertically plug and fix

Plug and install the entire machine chassis

Release the up and down pop-up handles, align with the chassis rails, and push in the board

Tighten the handle to lock it in place, and tighten the panel fixing screws

The RTM adapter board is installed from the back of the chassis using the same process


Chapter 6 Driver Installation Guide

Supporting operating systems

Windows 2000/XP/Server 2003, RedHat/Fedora Linux, VxWorks (BSP requested separately)

Standard driver installation sequence (with accompanying All in One CD)

Intel E7520 chipset INF bus driver

ATI ES1000 graphics card driver (divided into Win2000/XP step-by-step graphic and text operations)

82571EB Gigabit Network Card Driver

SAS driver (R6910 only)

Ultra320 SCSI driver (R6911 only)

Detailed operation of graphics card installation: Device Manager updates drivers, specifies the INF path of the CD, restarts and takes effect. Complete steps screenshot instructions


Chapter 7 Complete Development Materials for Two Level Watchdog WDT

WDT hardware block diagram

Integrated into 6300ESB South Bridge, 35 bit 32-bit down counter, two-level preloading registers, interrupt/reset control logic

Complete Register Description

BAR base address, two-level preload register, interrupt status, reload register, mode latch register, specify register unlock and write fixed instruction sequence

Work Mode

Standard watchdog mode: Level 1 timeout IRQ, Level 2 hardware reset

Free running mode: single-stage only, loop flipping WDT_TOUT output pin

Programming Standard Process

BIOS enables WDT → Reuse pins for WDT function → Configure frequency division and interrupt types → Write timer values → Enable timer, timed reload feeding dog to prevent reset

Supporting tools: HRWDT.EXE debugging tool under DOS, with sample source code attached on the CD; Simultaneously introduce the configuration conditions for PCIe diskless network boot


Chapter 8 Phoenix Ward BIOS Full Menu Detailed Explanation

Press Del/Tab to enter the settings when booting up. The complete nine main menus provide detailed descriptions of each function, option, and parameter, along with a screenshot of the BIOS interface

Standard CMOS standard settings: system time, IDE hard disk auto detection, memory information, boot error strategy

Advanced BIOS settings: CPU cache, power on self-test, boot sequence NumLock、 Serial port remote console (VT100/ANSI baud rate configuration), power on password mode

Advanced Chipset chipset settings: BIOS cache, memory ECC mode, CPU temperature control delay

Integrated Peripherals: IDE/SATA mode, USB controller, serial IO address, watchdog switch, PCIe network card boot ROM

PnP/PCI plug and play: IRQ resource automatic/manual allocation, PCI graphics card palette

Frequency and voltage control: Spread spectrum clock switch

Load default/optimize default parameters for faults

Administrator/User Level Startup Password Settings

Save exit/abandon exit operation


Chapter 9 IPMI v1.5 Substrate Management Interface (Remote Operation and Maintenance Core)

Target audience: IPMI protocol development, remote operation and maintenance engineers in computer rooms

Standard BMR-AVR-cPCI instruction set

Complete table listing of IPMI standard required/optional instructions: device recognition, hot/cold reset, watchdog control, sensor reading, FRU hardware information, event log SEL read/write

Linghua OEM Extended Exclusive Command (Factory Specific)

10 dedicated instructions, supporting firmware version query, remote power on/off, motherboard hard reset, SMBus bus switch, hardware address reading, debugging variable output, each with a complete byte protocol table for sending and receiving

CPCI Backplane IPMB Address Mapping Table

IPMB communication address corresponding to different slots of the chassis (slot codes 0-31)

Hardware Sensor List

Distinguish between B2 old PCB and B3 new PCB sensor items: 3.3V/5V/12V voltage, CPU/motherboard temperature, BMC watchdog, power failure detection

BMC firmware version iteration history, known defects

Defect: BMC does not have an independent RTC, and the internal time is reset to zero after the whole machine is powered off; SDR sensor logs are stored in Flash and cannot be randomly modified


Appendix: Complete Configuration Tutorial for Serial Remote Console

Without the need for a monitor or keyboard, use Windows Hyperterminal to view POST, operate BIOS and system through a cross serial cable:

Hardware: Definition diagram of null modem cross serial cable connection

Windows HyperTerminal installation, new connection, baud rate matching (9600/115200, etc.), terminal simulation ANSI settings complete set of graphic and textual steps

The BIOS should enable the Console redirection remote redirection switch, and the baud rates on both ends must be consistent

  • TRICONEX 3723X 32-Channel TMR Analog Input Module with HART for Tricon CX
  • GE 151X1233DB02SA02 Rev A Pitch Converter 30 Nm DC Pitch Conversion Module
  • GE 151X1207CK02SA02 77MM DE Excitation Module for Mark VI Turbine Control Systems
  • HIMA H6200A Analogue Isolator Power Supply for HIMax Safety Systems
  • ABB SACO 64D4 Digital Annunciator Unit with 64 Alarm Channels
  • Allen-Bradley 5069-L306ER - SER A CompactLogix Controller PLC
  • Omron CJ1W-CORT21 - CANopen Master Unit PLC Module
  • Danfoss 131B9523 / FC-102P5K5T4E20H1 - 5.5kW VLT HVAC Drive Inverter
  • Schneider Electric LXM32MU90M2 - Lexium 32 Servo Drive Controller
  • Danfoss AKD102P15KT4P21H1 - 15kW 131L2413 ADAP-KOOL Drive Inverter
  • Kollmorgen S70602-NANANA - Servo Drive Controller
  • Allen-Bradley 6189-PS2 - Power Supply Industrial Computer PS
  • Beijer E900T / 03010F - Operator Panel IFC ETTP HMI
  • Schneider Electric LMC20 - PacDrive Motion Controller PLC
  • Sartorius CAW2S1-3DC-NCE - COMBICS 2 Industrial Scale Terminal
  • Kollmorgen / Danaher S30301-NA / S300 - SERVOSTAR343 Servo Drive Controller
  • Siemens A5E00159503 - 12 INCH TFT Touch Panel HMI
  • Siemens 3UF5021-3AB00-1 - SIMOCODE DP Basic Unit Control Module
  • Danfoss 131B8872 / FC-202PK37T4E20H1 - 0.37kW VLT AQUA Drive Inverter
  • Atlas Copco ICB421-2003D / VSK001001 - W9139 ICM431-0025C ICM431-0025D Controller
  • Lenze EV82EV751_4C - Version 4A39 Frequency Inverter Drive
  • Atlas Copco / ABB 3HAB8101-19/07B - Robot Cable Assembly Harness
  • Beijer X2 Pro7-B2 - Operator Panel HMI Touch Screen
  • Honeywell CDW45L - Damper Actuator
  • B&R X67DM9331.L12 - Rev. I0 Digital Mixed Module
  • B&R X67DM9331.L12 - Rev. H0 Digital Mixed Module
  • Sanyo Denki PMM-BA-5604-1 - Pentasyn Stepper Motor Driver
  • SICK AWS1-113 / 1008900 - Evaluation Unit
  • Siemens 1TF6064-1AF71-3AH1 - SIMOTICS Synchronous Servo Motor
  • Heidenhain ERN680.P003-4096 / 29416004 - Rotary Encoder
  • Schneider Electric LC1G185EHEA - TeSys Control Contactor
  • Parker SBC HPD5N - High Performance Drive Electronics SPA
  • Advantech UNO-2170-CE11BE - Embedded Automation Computer IPC
  • Siemens 6AG1231-4HF32-4XB0 - SIPLUS S7-1200 SM 1231 Analog Input Module
  • Advantech UNO-2170-BTO - Embedded Automation Computer IPC
  • Jumo SR-96/4-001.0.0.00.111 - Solid State Relay Power Controller
  • Pepperl+Fuchs FC-21-V - FC-20P Safety Barrier Module
  • Emerson SP1404 - Unidrive AC Drive Inverter
  • B&R X67AI1233 - Rev.C0 Analog Input Module
  • Mitsubishi FR-F740-00250-EC - Frequency Inverter AC Drive
  • Allen-Bradley 2711P-T7C21D8S - PANELVIEW PLUS 7 SERIES B Touch Screen HMI
  • Pilz PMCprotego D.03/000/0/0/2/208-480VAC / 8176101 - Servo Amplifier Drive
  • Reliance Electric 57C414 / 57414-1N - Modbus Interface Module
  • Mitsubishi FR-F740-00250-EC - Frequency Inverter AC Drive
  • Siemens 6SN1123-1AA00-0EA2 - Version A 160A SIMODRIVE Power Module
  • Siemens 1TF6064-1AF71-3AH1 - SIMOTICS Synchronous Servo Motor
  • AEG ALU202 / DAP216 / DEP216 / DAU202 - SIM216 SIM203 DNP205 ADU205 PLC Controller KIT
  • Atlas Copco / ABB 3HAB8101-19/07B - Robot Cable Assembly Harness
  • Hitachi CPU22-02HB - Micro-EHV Programmable Controller PLC
  • Parker SBC HPD5N - High Performance Drive Electronics SPA
  • Jetter JX3-THI2-RTD - JX3-BP Temperature Input Module
  • Eaton DC1-34014FB-A20N - 5.5kW Inverter Variable Frequency Drive
  • Eaton DS7-34DSX041N0-D - Soft Starter
  • Reliance Electric 57C422B / 57422-2E - 2-Axis Servo Controller
  • Hitachi CPU22-02HB - Micro-EHV Programmable Controller PLC
  • Eaton DC1-34014FB-A20N - 5.5kW Frequency Inverter Variable Frequency Drive
  • Siemens 6SN1123-1AA00-0EA2 - Version A 160A SIMODRIVE Power Module
  • Reliance Electric 57C414 / 57414-1N - Modbus Interface Module
  • Eaton DS7-34DSX041N0-D - Soft Starter
  • Reliance Electric 57C422B / 57422-2E - 2-Axis Servo Controller
  • Johnson Controls DX-9120-8454 - Digital Controller
  • Jetter JX3-THI2-RTD - JX3-BP Temperature Input Module
  • Siemens 6SL3210-1KE21-7AP1 - SINAMICS G120C DP 7.5kW BOP-2 Inverter Drive
  • Siemens 1FK7042-2AF21-1QG0 - SIMOTICS S Synchronous Servo Motor
  • Mettler Toledo IND570 - Harsh Analog Weighing Terminal Controller
  • Schneider Electric TM238LDA24DR - Modicon M238 Programmable Logic Controller PLC
  • Hitachi EH-CPU548 - EH-150 PLC CPU Module
  • Honeywell Q7750A2003 - Excel 10 Zone Controller
  • Ferag 584.002.V003 - Control Panel HMI
  • Danfoss AK-SM 720 / 080Z8511 - ADAP-KOOL System Manager Controller
  • Ferag 584.002.V003 - Control Panel HMI
  • Kern 3210001.001 / LOP-KS 2903440.001 - PRT.205A.0000.V001.02341 Servo Controller Board
  • Reliance Electric 57C424 - Maxpak III High Speed Link Module
  • Telemecanique XBTA70101PA - Compact Terminal HMI Panel
  • Reliance Electric 57C424 - Maxpak III High Speed Link Module
  • Reliance Electric 57C422B - 2-Axis Servo Controller
  • Honeywell Q7750A2003 - Excel 10 Zone Controller
  • Telemecanique XBTN400 - Magelis Small Panel HMI
  • Schneider Electric TM172PDG42S - Modicon Programmable Logic Controller PLC
  • Fanuc HE693THM884M - Thermocouple Input Module
  • Selectron PMC22BAEZD / 220735 - Selecontrol PMC 22 ABEZD Controller Module
  • Baumuller BUS21-22/45-31-020 - Servo Drive Inverter
  • Schneider Electric TM172PDG42S - Modicon Programmable Logic Controller PLC
  • Schneider Electric ATV32HD11N4 - Altivar Variable Frequency Drive Inverter
  • Lenze 494_E.4B - DC Speed Controller
  • NORD SK300E-111-340-B - SKDA130E-111-340-IBS-AAA Frequency Inverter
  • Reliance Electric GMI-S02 - AC/AC Converter 380/400V 50/60Hz 2.3/2.8A Drive
  • Hakko / Monitouch V710CD - Operator Panel HMI Touch Screen
  • B&R 5PC910.SX01-00 / 5YZCAA00700000-005 - Automation PC Industrial Computer
  • Hitachi EH-CPU548 - EH-150 PLC CPU Module
  • Tecnau / Fortec FORTEC-04/UL / 10117 - PCB Circuit Board
  • Bosch PSS 2037 10B - Power Supply Module
  • Newall B602000 - Digital Readout Scale
  • ELCON PC Controller - Industrial PC Controller
  • Siemens 3UF5100-0AB00 - SIMOCODE-DP Control Module
  • Omron NS8-TV00B-V2 - Touch Screen HMI Panel
  • Siemens 6ES5264-8MA12 / IP264 - CAM Controller Module
  • Allen-Bradley 1756-L72S - SER B GuardLogix Safety Controller
  • Schneider Electric SXWMPC15A10001 - SmartX Controller Automation Server
  • Telemecanique LC1F265F7 - TeSys F Contactor
  • Siemens 6ES7314-6CH04-0AB0 - SIMATIC S7-300 CPU 314C-2 DP PLC
  • Allen-Bradley 1734-EI4S - POINT I/O Safety Module
  • Allen-Bradley 2711P-T7C4D8 / 2711P-RP8D - PanelView Plus HMI Touch Screen Logic Module
  • Ropex UPT-640-V - Resistron Temperature Controller
  • KEB 07.F5.B3A-0A00 - VERSION 1.1 Combivert Frequency Inverter
  • Sensopart V50-OB-A3-IW-M2-L - VISOR Vision Sensor Camera
  • SICK AFM60A-S1NB018X12 / 1059040 - Absolute Rotary Encoder
  • Kern AG KMC600 / 2903436.001 - Servo Drive Controller
  • Lenze E82EV302_4C200 / 13015655 - VERSION 3D35 Frequency Inverter Drive
  • Schneider Electric XBTOT2210 - Magelis Touch Screen HMI Panel
  • Baumuller BM5-O-SAF-000-000-000-001-202 - Parameter Safety Module
  • SICK UE4470-22EE690 - Safety Relay Controller
  • Hitachi EH-CPU448 / EH-150 - PLC CPU Module
  • Rexroth VT5005-13 - R5 00010592 Proportional Valve Amplifier Board
  • Siemens 6ES7510-1DJ00-0AB0 - SIMATIC ET 200SP CPU PLC
  • Beckhoff CX5120-0121 - 2GB Embedded PC Controller
  • Priva BlueiD S10 / 5010002 - SN3t 5020004 5010101 Building Automation Controller
  • Sigmatek DM161 - S-DIAS Digital Mix I/O Module
  • Telemecanique LC3D50P7A64 - Star Delta Starter Contactor
  • Siemens 6SN1123-1AA00-0BA2 - SIMODRIVE 611 Power Module
  • Siemens 6SN1124-1AA00-0CA1 - SIMODRIVE 611 Power Module
  • Dixell XC1015D-1C01F / XC1000D - Compressor Controller
  • Siemens A5E02184619 / 19T 577B - Industrial Touch Screen HMI Panel
  • Siemens 6SE6420-2AD27-5CA1 - Filter 6SE6400-2FS03-8CD0 Micromaster Inverter
  • Schneider Electric LC1G400LSEN - TeSys Control Contactor
  • Baldor BPS10-200-20-P - Servo Drive Motor Controller
  • Ingersoll Rand X4I / Y06IR03.00 - Air Compressor Controller
  • NORD SK 530P-221-340-A - Frequency Inverter