Hardware and environmental technical parameters

Electrical Specifications

Output: DC 36/42   V, rated power 400   W

Environmental usage conditions

Usage scenario: Indoor only; The highest altitude is 2000 meters

Working temperature:+5 ℃~+40 ℃; Storage temperature: -25 ℃~+60 ℃

Humidity: ≤ 31 ℃, maximum 80% RH, linearly decreases to 50% RH at 40 ℃

Voltage fluctuation: nominal voltage ± 10%; Overvoltage category II; Pollution level 2; Protection level IP20

Compatibility Table for Supporting Power Adapter

Power supply model, order number, adapter tool

MT PS 180W‑36V 8432084002 ETD MT21/41、ETD M ABL V2、QMT21/41、QMC21/41

252W-42V power supply 8432084007 ETD MT61, ETD MC61, QMT61, QMC61, backward compatible with MT41/QMT41/QMC41, etc

Typical working cycle of the tool: 1 second work, 4 seconds rest; The actual allowable duty cycle depends on the torque and joint type, and the equipment is equipped with overheat protection to prevent over cycling.

Mandatory process verification requirements (tightening quality responsibility clauses)

After any event that affects the tightening process occurs, the actual installation torque and rotation direction must be verified.

Trigger verification scenario: initial installation of the system; Parts/bolts/tools/software/configuration/environmental changes; Electrical wiring modifications; Production line technology, quality process, operator replacement, etc.

Verification execution timing: Verification must be carried out after initial installation, maintenance and repair are completed; At least one verification shall be carried out per shift to confirm that the working conditions of the bolt joint have not changed.


Various compliance statements

EU CE: Compliant with RoHS (2011/65/EU), EMC electromagnetic compatibility, LVD low voltage directive; Reference coordinated standards such as EN61010-1 and EN61000 series.

WEEE waste electronic equipment: the product is marked with a forked trash can and cannot be discarded as domestic garbage. The whole machine/parts are sent to Atlas Customer Service Center for recycling.

REACH regulation: Some components of the equipment contain lead and are included in the REACH candidate list; Normal use will not precipitate, in compliance with RoHS exemption; Dispose of lead containing waste according to local regulations when scrapped.

FCC in the United States/ISED in Canada: Class A industrial equipment; The home environment can cause radio interference; The antenna cannot be modified without authorization.

California Prop65 warning: The product contains lead, which is recognized by California as having carcinogenic and reproductive damage risks.

GDPR EU data protection: controllers can store personal information such as usernames, roles, IP addresses, etc; The user is responsible for compliance, and Atlas is not responsible for user personal data processing.

General safety requirements

1. Use boundaries

Only suitable for industrial indoor dry environments, strictly prohibited from explosive hazardous environments; Only professional personnel are responsible for operation and maintenance.

Usage limitation: Only used for monitoring and driving tightening tools, prohibited for other purposes; It is strictly prohibited to modify equipment and accessories without authorization; The shell is damaged and the warning label is blurry and detached, and needs to be replaced immediately.

EMC electromagnetic compatibility is only applicable to industrial environments.

2. Key points of electrical safety

The equipment must be reliably grounded, and it is strictly prohibited to remove the grounding pin or connect to a socket; Before repairing and opening the cover, the power plug must be unplugged.

Original factory certified cables must be used, and unauthorized modification of cables is prohibited; Replace the damaged cable immediately.

Stay away from arc welding equipment to avoid welding interference; When working simultaneously with the welding machine, the workpiece must be independently grounded, and the cross-sectional area of the grounding conductor must be at least equal to the welding machine's return cable to prevent welding return current from entering the controller's grounding circuit.

The equipment is not waterproof, so avoid getting wet from water.

3. Installation and Handling

Installation and maintenance are only allowed to qualified personnel who have received training; Before plugging or unplugging tool cables, be sure to disconnect the mains power and turn off the controller.

Disconnect all wiring before transportation to prevent cable breakage and damage; Keep the storage environment dry, avoid dust and corrosive media, and avoid severe temperature fluctuations.

4. Operational safety

The position of the power-off switch should be easily accessible to the operator.

The tool head should not touch the internal conductors or other hidden live parts of the cable.


Maintenance Regulations

Cleaning: Only use a damp cloth with clean water to wipe; Solvent based cleaning agents are strictly prohibited.

Cable inspection: Regularly check power cords and tool cables, and replace them immediately if they are damaged.

ESD electrostatic protection mandatory requirement: The internal components of the controller are highly sensitive to static electricity. Anti static workstations (anti-static mats+anti-static wristbands) must be used for maintenance and disassembly; The document comes with a standard ESD workstation diagram, which may cause random failures if the environment is not met.

Troubleshooting and system restart are only allowed to be operated by authorized personnel.

Calibration certificate download: MT Focus6000 has completed calibration at the factory; Enter the serial number to download the original factory calibration certificate on the official website's WebCert page.

  • SHINKAWA FRP 360A - BOARD
  • SHINKAWA IBP-43AM - PCB Board
  • SHINKAWA IBP-42-M - PCB Board
  • SHINKAWA DSP-11C - PCB Board
  • SHINKAWA FRP-341E - BOARD
  • SHINKAWA CPP-111 - PCB Board
  • SHINKAWA FRP-342A - BOARD
  • SHINKAWA FRP-341D - BOARD
  • SHINKAWA MDP-X MDP-135 - PCB Board
  • SHINKAWA MGP-57 - BOARD
  • SHINKAWA FRP-226A - PCB Board
  • SHINKAWA MDP-141 - PCB Board
  • SHINKAWA IOP-188 - BOARD
  • SHINKAWA FRP-341C - BOARD
  • SHINKAWA MDP-90 - PCB Board
  • SHINKAWA CPP-107A - PCB Board
  • SHINKAWA FRP-227A - PCB Board
  • SHINKAWA FRP-249A - PCB Board
  • SHINKAWA MDP-74 - PCB Board
  • SHINKAWA FRP-270 FRP-268 - PCB Board
  • SHINKAWA FRP-386 - PCB Board
  • SHINKAWA ZUP-02C - BOARD
  • SHINKAWA MDP-136A - PCB Board
  • SHINKAWA FRP-259 - PCB Board
  • SHINKAWA JBP-470 - BOARD
  • SHINKAWA MDP-82 - BOARD
  • SHINKAWA FCP-07A - PCB Board
  • SHINKAWA DSP-09A - PCB Board
  • SHINKAWA IOP-178 - PCB Board
  • Nemic-Lambda / Shinkawa VS15C-15 CCB010A UTC-1000 - Power Supply Board
  • SHINKAWA IOP-176A - PCB Board
  • SHINKAWA VM-5C SST-2194-001-P001G - ECCENTRICITY MONITOR
  • SHINKAWA VM-5K SST-2194-001-P001G - VIBRATION MONITOR
  • THK / Shinkawa SRS9M UTC-1000 - Linear Block w/ Rail 26cm
  • Shinkawa JBP-316 P-26-73B-1 P-26-73A-1 UTC-1000 - Board
  • SHINKAWA IOP-215 - BOARD
  • SHINKAWA JBP-268 - PCB Board
  • SHINKAWA ZUP-08 - PCB Board
  • SHINKAWA BCP-05A - BOARD
  • SHINKAWA DSP-15 - PCB Board
  • SHINKAWA FRP-289 - PCB Board
  • SHINKAWA FCP-01 - BOARD
  • SHINKAWA MDP-84 - BOARD
  • SHINKAWA CMU-13A - CAMERA MOTION CONTROLLER
  • SHINKAWA BCP-05D - PCB Board
  • SHINKAWA MDP-FF MDP-87 - Stage Control Board
  • SHINKAWA FRP-342 - BOARD
  • SHINKAWA BCP-05C - BOARD
  • Shinkawa CMU-26A - Camera Control unit
  • SHINKAWA PSP-30 - Welding Machine Control Board
  • SHINKAWA EFU-24 - Spark Generator
  • Shinkawa CMU-27A - Camera Control unit
  • SHINKAWA CMU-44 - Camera Control Unit
  • THK / Shinkawa SRS9M UTC-1000 - Linear Block w/ Rail 21cm
  • TDK-Lambda / Shinkawa VS100B-24 VS100B24 UTC-1000 - Power Supply Board
  • SHINKAWA CMU-34 - Camera Control Unit
  • SHINKAWA FDP-06A - PCB Board
  • SHINKAWA BCP-06A - BOARD
  • SHINKAWA CMU-13A - Camera Control Unit
  • SHINKAWA CMU-31A - Camera Control Unit
  • SHINKAWA VM-5Y1-02/GEM 1594-005-P001G - ECCENTRICITY MONITOR
  • Shinkawa JBP-331 P-26-101B P-26-101A P26101A UTC-1000 - Board
  • SHINKAWA CMU-26 - Camera Control Unit
  • Shinkawa ACB-3000 ACB3000 - Industrial-Grade Automated Friction Bonder
  • Shinkawa SBB-1100 SBB1100 - Stud Bump Bonder Machine
  • Shinkawa ACB-1000 ACB1000 - Super Automated Wire Bonder Machine
  • CKD / Shinkawa FCS500-H6H6 FCS500H6H6 UTC-1000 - Precision Air Source Filter
  • SHINKAWA VM-5H3 1596-001-P002B VM-5Z1 3595-001-P003C - Power Supply Monitor Rack
  • SHINKAWA VM-5H3 2194-001-F004B - Dual Vibration Dual Thrust Monitor Rack
  • Shinkawa EFU-10 - Wire Bonder Spark Generator EFO Box
  • SHINKAWA MP-2S - Overspeed Unit Instruction
  • Shinkawa PK-167B-3 PK-167A-3 10P-10 - PCB Board
  • SHINKAWA VM-3D VM-3E VL VM-3D2 - Vibration Sensor Mit Verlangerungskabel
  • shinkawa FKP-452F2-3 - Sensor
  • shinkawa UTC-1000 ZUP-02B - PCB BOARD
  • SHINKAWA VM-3D VM-3E VL VM-3D2 - VIBRATION SENSOR WITH EXTENSION CABLE
  • Shinkawa E194236-0003 AWM 2464 UTC-1000 - Cable 6&4 Pins Female-Female
  • TDK-Lambda / Shinkawa VS100B-15 VS100B15 UTC-1000 - Power Supply Board
  • Shinkawa FK-202F2-2-1 - Electric Vortex Sensor
  • Marubeni Shinkawa S038493 - Rotary Encoder
  • Shinkawa E194236-0003 AWM 2586 UTC-1000 - Cable 10 & 8 Pins Male-Female
  • National / Shinkawa CAT5E NR3160 UTC-1000 - Ethernet Receptacle Connector Cable
  • Shinkawa LLS2902 E69157 UTC-1000 - Cable 3 Pins Male-Female
  • Shinkawa AWG16 600V UTC-1000 - 5 Pins Cable Female-Female
  • SHINKAWA WK-142K2-2 - Vibration sensors
  • Shinkawa DA-C8-J10 DAC8J10 UTC-1000 - Connector Cable
  • Shinkawa P-27-67B P2767B P-27-67A P2767A UTC-1000 - Circuit Board
  • Taiyo / Shinkawa E67647-WH E67647WH UTC-1000 - Computer Power Cable
  • Shinkawa E66085-H 20276 UTC-1000 - Connector Cable 15 Pins Male-Male
  • Shinkawa P-28-49B JBP-380C P-28-49A BEJ240619A UTC-1000 - Board w/
  • Shinkawa WKN-142K2-2 - 2-Wire vibration transmitter
  • SHINKAWA VM-741 VM-741B - MONITORING SYSTEM
  • Shinkawa FL-202F08R-U2-02-12-10 - Extension probe
  • Shinkawa FK-202F-1-3 FK-202F-2-3 - module
  • Shinkawa CMU-13A CMU13A - Camera Motion Control Unit Cut Cable
  • SHINKAWA VM-5J - DUAL DIFFERENTIAL EXPANSION MONITOR
  • Ebrain / Shinkawa 650-VME08IS-S N6071085 UTC-1000 - Backplane Panel Board
  • Yaskawa Electric / SHINKAWA UGQMEM-06-SW12 MD-11 - Minertia Motor w/ 30 day warranty
  • Shinkawa FL-202F08R-U2-02-12-10 - Extension probe
  • Shinkawa WT-650-16 SP-256A UTC-1000 - Power Source Power Supply AC100V 50/60Hz
  • SMC C96ST80-600 - Pneumatic Cylinder 80mm Bore 600 Stroke
  • MOORE INDUSTRIES AIM/IO/AI4/IP - Analog Input Module
  • IMAI ELECTRIC NBS-200S-2XSET - SMALL TRANSFORMER
  • FCI OEM-019469-04-02 - Flanged Inline Flow Transmitter
  • FAGOR EC-9PA-DQ1-M - CABLES NEW
  • FAGOR EC-9AM-MB - CABLES NEW
  • ATLAS COPCO LUM22 SR4 - Pneumatic Screwdriver
  • REXROTH HE751863 - VALVE NEW
  • SANYO SDNM-MCA - SERVO DRIVE
  • EGS WTC 303-1761 - TRANSFORMER
  • SQUARE D H362 - Heavy Duty Safety Switch
  • ALLEN BRADLEY 140G-J-FCX04 - Operating Mechanism 250A J Frame
  • GRACO 24E451 - Teach Pendant 120VDC NEW
  • RITTAL SK3125 - AIR/WATER HEAT EXCHANGER 5120BTU 115V/230V
  • FESTO DF00A - Guided Pneumatic Cylinder
  • SMC CDG1BA20-4050-H7B3-XC10 - Pneumatic Cylinder
  • FUJI FKCT33U5AXCYYAA - Differential Pressure Transmitter NEW
  • Allen Bradley 440E-A13082 - Guardmaster Rope Pull Accessory Kit (20m) NEW
  • LECO RT-120-A 1986 - Hardness Test Block Kit AS-IS
  • BALLUFF BCC A313-A313-30-345-VX43W6-300 - Industrial Connecting Cable BCC0HZ8 NEW
  • SIEMENS 6SN1162-0BA02-0AA2 - SINAMICS Cooling Fan Motor Assembly
  • GC VALVES S211YF02N1GJ5 - Solenoid Valve NEW
  • BALLUFF BNI EIP-302-105-R015 - DIGITAL I/O
  • STI RM-3-HA1 - MUTE MODULE
  • ALLEN BRADLEY 284-PWRM29A-M4 - ArmorConnect 3PH Pwr Media Shld Mtr Cbl NEW
  • BALLUFF BNI008A - LED STACK LIGHT
  • Grossenbacher LG-NR.50 70 73 - CIRCUIT BOARD NEW
  • Keyence XG-H1XA V3.1 - Vision System Software DVD NEW