+086-15305925923

K-WANG

Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

XYCOM Automatic 9987 Operating Interface PN.9987-3338-2100 Computer Board

From: | Author:Wang | Time :2025-05-30 | 449 visit: | 🔊 Click to read aloud ❚❚ | Share:
XYCOM Automatic 9987 Operating Interface PN.9987-3338-2100 Computer Board

The 9987 PC/AT™ Flat-panel Industrial Computer (also known as the Portrait PC) com bines a PC/AT computer with a flat-panel display to offer a powerful, compact package for the factory floor and other harsh environments. 

The 9987 features an open architec ture to meet a wide variety of applications where both a powerful PC and a durable in dustrial enclosure are required. 

The system integrates a computer card cage, mass stor age, display, keypads, and power supply in a truly industrial form factor.

The 9987 system includes a four-slot, full-length, passive ISA backplane, a VGA flat panel display, hard and floppy disk drive facilities, and data entry/function keypads. 

The front panel is sealed to NEMA 4/4X/12 standards, and the flat-panel display is protected by an impact-resistant shield. 

The open-architecture design accepts IBM PC/AT compatible cards and keyboards.

The processor board combines the functions of a IBM PC/AT-compatible computer on a single, industrially-hardened circuit board. Refer to the Xycom CPU manual for more in formation on processor and hardware features.

The system’s modular design allows easy access to boards, switches, power supply, and disk drives. 

You can easily remove the drawer by detaching six ACCESS fasteners.


Standard Features

The 9987 offers the following standard features:
• High-performance, single-board 486 and Pentium® processors
• 5.62-inch mounting depth
• Four-slot, full-length, passive ISA backplane
• 10.4-inch 256-color CCFT TFT LCD flat-panel display (640x480)
• 32 data entry and 10 function keys
• 3.5-inch 1.44 Mbyte floppy drive
• MS-DOS®
• Slide-out computer module (to access disk, backplane, and power supply)
• 110-watt power supply
• IBM PC/AT compatibility
• Front or rear access floppy disk
• External printer port
• External COM1 and COM2 ports (RS-232)
• Front panel sealed to meet NEMA 4/4X/12 specifications when panel mounted


Optional Features

The following optional items are also available with the 9987:
• A variety of high-capacity IDE hard drives and Solid State (Flash) drives
• RADAR card with isolated RS-232C/RS-485 serial ports
• External full-stroke keyboard
• Durapoint sealed front-panel mouse
• Various sealed rack- or panel-mount keyboards
• Preloaded Windows® 95 or Windows NT operating systems
• Hazardous location configurations


Unpacking the System

When you remove the 9987 from its box, verify that you have the parts listed below. 

Save the box and inner wrapping in case you need to reship the unit.

• 9987 unit
• Documentation kit, which includes
Power cable
PKIM utility disk
Diagnostic software disk
20 hex nuts (6 spares)
9987 user manual
CPU manual
VGA utility disk
• Binder
• Business reply card


Quick Start-up

Warning
Turn off the power to the unit and unplug the power cord before making any adjust ments to the inside or outside of the computer.
Perform the following steps to prepare the system for use.
1. Attach optional keyboards/mouse.
• Connect an external keyboard to the keyboard connector behind the access door on the front panel or to the connector on the power panel.
• A serial mouse can be connected to either COM1 or COM2. When a mouse is used, the COM LED on the data entry keypad lights up.
2. Attach other optional equipment following the instructions in Chapter 3.
3. Attach the power cord from the power receptacle to a properly grounded 90-250 VAC, 50-60 Hz outlet.
4. Turn on the power to the unit. The system will boot up at the C: prompt.
5. Install application software via drive A: located behind the access door on the front panel


Quadtel BIOS

If the CPU board has a Quadtel BIOS,  press CTRL+ALT+S simultaneously after the POST RAM test has completed to access the Setup Menu. 

Make changes by following directions on the screen. 

Press F10 to save the Setup, and ESC to exit. Refer to your CPU manual for more information on the Setup Menu.

Preparing for the Tests
To test your system, you need the following equipment:
• Xycom System Test Disk (bootable 3.5-inch, DS/DD disk), Xycom part number
99290-001
• IBM PC/AT-compatible keyboard (Xycom part number 91971-001 or equivalent)
• Centronics-compatible printer cable
• Parallel printer (Centronics-style interface)
• Two serial loopback test connectors (refer to Figure 2-1 for pinouts)
• Formatted scratch disk (3.5-inch, DS/HD)
Perform the steps below before starting the system tests:
1. Place the CPU board jumpers and switches to the factory-set positions. Refer to your
CPU manual for these settings.
2. Plug the female end of the AC power cable into the side of the unit and the male end
into a properly grounded outlet.
3. Connect the serial loopback connector(s) and the printer cable to the appropriate
connectors and connect a PC/AT keyboard to a keyboard connector. Figure Chapter
2 -1 illustrates the wiring necessary for the loopback connection.

Removing the Slide-Out Module
1. Remove the six ACCESS fasteners that attach the slide-out computer module to
the 9987 back panel. (A ¼-inch nut driver is needed to remove the 8/32 size fas teners.)
2. If the unit is not panel mounted, place it face down. Hold the front part down
(located behind keypad) while pulling off the back panel to break the intercon nect connection.
3. Grasp the handles that protrude from the back panel on the left and right sides, above the I/O inserts.

4. Pull straight back. The module should slide out easily. 

9000-RAD Card

You can install the 9000-RAD card if you have an open slot. 

Before installing the card (Solid State Disk) into the 9987, jumpers and switches must be set for your par ticular configuration. 

After the 9000-RAD is properly configured, it can be installed into the 9987 card
cage as follows:
1. Unplug the 9987 from the AC wall outlet.
2. Remove the 9987 slide-out computer module (refer to the Removing the Slide
Out Module section earlier in this chapter). Set the six ACCESS fasteners aside for later use.
3. Verify jumper and switch settings. Refer to the 9000-RAD manual for the cor rect settings.
4. If present, remove the blank ORB from the slot that the 9000-RAD card will oc cupy. Save the screw.
5. Place the 9000-RAD card into the slots in the backplane. Push down on the card evenly, until it firmly seats into the card edge connectors.


FloNet Interface Board

You can also install a IPN200 FloNet interface board in your system. 

The FloNet board has two modes of operation: 

Ethernet and FloNet. In Ethernet mode, the board provides a standard Ethernet network interface with user-configurable hardware in terrupts, I/O ports, and bootable ROM BIOS address location.

In FloNet mode, the FloNet board acts as the interface between a local host running FloPro software and an Ethernet LAN connected to at least one remote host platform running TCP/IP-compatible software. 

The on-board firmware constantly polls the Ethernet network interface waiting for packets where are intended to communicate with FloPro. 

The board will also process valid TCP/IP protocol packets.

When configured for FloPro mode, the FloNet board takes up to six eight-bit I/O ports, and 32 Kbytes of memory. 

When configured as an Ethernet card, the FloNet board takes an additional 16 I/O addresses. 

It may also take up an additional 32

Kbytes of memory space if configured to use a boot ROM.
Refer to the FloNet documentation for installation instructions

XYCOM 9450 OPERATOR INTERFACE MONITOR 713316-A 220396A 9450 ...

  • Metso XZB10025-011T12 - Moog Valve 9650962700
  • Metso XZB10025-010T12 - Moog Valve 9650965300
  • Metso-SP Transmitter Cable - Operating Unit with 10m Cable
  • Harkila Metso Hybrid - Hunting Jacket Willow Green
  • Metso ND8221/S1 - Neles Valve Positioner
  • Metso METSO10119 - ScreenCheck Component
  • Metso LK-2025 - Linkage Kit
  • Metso A416733 - IQweight External Air Gap Temperature Sensor
  • Metso RKC22MT - Automation Component
  • Metso A413281 - Automation Board
  • Metso LCP9HLY - Stainless Steel Enclosure
  • Metso NP704S/B1S1 - Pneumatic Positioner with I/P Converter
  • Metso BAH3 - Slurry Seal Type
  • Metso A413531-03 - PLC Module Chassis Rack
  • Metso P4610004 - MCAI Communicator Controller
  • Metso QN2AN03HDM - Quartz Valve Positioner Stonel
  • Metso RKW-352-XZ - Automation Component
  • Metso A4300081 - Kajaani LCD Display
  • Metso A428026 7B - Kajaani Rectifier Unit 1
  • Metso 202218 - Kajaani Sensor Power Supply SR 902660
  • Metso 9150 316SS CSTL - Jamesbury 150-2" BN50 Valve
  • Metso 81806 - IOP101 Module
  • Metso STOM000272 - Paper Bushing CR38
  • Metso 1975413 - Chain Hoist Links
  • Metso IMO G053-191597 - Minor Seal Kit
  • Metso VAL0087418 - Cylinder Valmet NTS6LV
  • Metso A413061 - DMU Board VPA 420355-4B
  • Metso P2620-80/25-100 - Automation Component
  • Metso VAL0035292 - Automation Component
  • Metso A413721 - Automation Component
  • Metso ST600 - Automation Component
  • Metso P4500001 - Automation Component
  • Metso SDBX/RA2 - CAT x KVM Extender
  • Metso D201126-DI8 - Digital Input Module
  • Metso D201189L - AI8H Analog Module
  • Metso NA004418 LK1016 - Wafersphere Actuator Mounting Bracket
  • Metso RKN172MTT - Repair Kit
  • Metso MM0311584 - Air Filter Kit RadialSeal
  • Metso 181517 - IOP301 Isolated Analog Input Module
  • Metso RAU3906506 - Automation Component
  • Metso 181208 - IOP332 Digital Input Module
  • Metso A413760 - AIF2C PCB Module
  • Metso 006 1089 36 - Shaft Bearing Seal
  • Metso A413046 - Automation Component
  • Metso VKJ650 - Automation Brake Component
  • Metso LK-1875 - Linkage Kit
  • Metso D201193L - FI4S24 Frequency Input Module
  • Metso D200533 - BIU82 Binary Input Module
  • Metso 500838-M1 - Impeller Pump Release Collar Assembly
  • Metso 2.00SB2ALUS19A - Pneumatic Cylinder 1.375 Stroke
  • Metso D201351 - RES Reserve Module
  • Metso A416100 - IQMoisture Spare Part Kit Halogen Lamp
  • Metso Slurry Pump - Back Liner
  • Metso 7088010042 - Bronze Lantern Ring
  • Metso IMC-101-M-SC - Industrial Media Converter
  • Voith S1-S1-CAM-ENCL - Metso Pump Cmare Housing & Bracket
  • Metso A4430726V1.1 - Kajaani Connection Box CI 4-9-10
  • Metso A413016 - NCU2 PLC Board
  • Metso D202213P - MBMT80 Base
  • Metso A413135 - AOU-4 Analog Output Board
  • Metso NP 724A - Pneumatic Valve Positioner
  • Metso A413246 - Automation Controller Module
  • Konaflex VKJ-650 - Disc Brake Set Pair
  • Metso WIN3096535D - Core Chuck
  • Metso D201380 - MBR Base with IBC & IPS
  • Metso D202213L - MBMT80 Base Module
  • Metso 181571 - IOP337 PLC Module
  • Metso MF0588336 - Main Hydraulic Filter
  • Metso 181504 - IOP303 RTD Input Module
  • Metso A413240 - PIC2 Board
  • Denver 566534PS - Case Liner Gland Side SRL Frame 2
  • Metso 181508 - IOP322 Digital Input Module 120V
  • Metso 181520 - IOP351 Relay Output Module Form A/B
  • Metso 181220 - IOP351 Relay Output Module
  • Metso A413150 - BOU 8 Binary Output Module
  • Metso 128400-M1 - Impeller
  • Metso D201379 - MBB Base with IBC & IPS
  • Metso 205181 - T/B MTD PRWSW Assembly
  • Metso QPX1C/K15 - Jamesbury Quadra-Powr X Actuator Valve
  • Harkila Metso Winter - Hunting Jacket Willow Green
  • Metso NE724A/A-L - Electro-Pneumatic Positioner
  • Metso PACP-100-80-31 916 - Automation Component
  • Metso 81814 - Automation Component
  • Metso ER-12-01-M-CT - Automation Board
  • Metso ELO24 - Automation Board
  • Metso A413000 - Valmet Neles CPU PLC Board
  • Metso XL-2213-0525 - Mainframe Bushing
  • Metso D100097 - ECR Extension Module
  • Metso 804511 - Filter Housing Assembly
  • Metso S420154 - Automation Rack Chassis
  • Metso M851232 - Automation Module
  • Metso D100532 02 - Automation Board
  • Neles QPX1C/M - Ball Valve with Quadra-Powr X Actuator
  • Metso 181535 - IOP322 Isolated Analog Output Module
  • Metso RKN-184-XTZ - Ball Valve Seat Repair Kit 4"
  • Metso N22022621 - Metal Plate
  • Metso 181560 - IOP341 Positioner Module
  • Metso LT 1213 S - Filter Service Kit for CAT C12 Engine
  • Aq-Matic 0032-99000 - Valve Diaphragm
  • Metso D200535 - BOU8 Output Board
  • Metso EDS-305-M-SC - Ethernet Switch
  • Metso 80424 - IOP110 Analog Output Module
  • Metso IOP351 - Relay Output Module Form A/B
  • Metso 181572 - IOP342 Module
  • Metso 1-1-2A3600TT - Ball Valve 1.5"
  • Metso A413154 - BOU8-4 Output Module
  • Metso A413140 - Valmet BIU 8 Board
  • Metso D201139 - IPS Power Supply type DDC7940
  • Metso PGH P411382-2000 - Metal Feed/Filtrate Hose
  • Valmet 503201404 - Automation Board
  • Metso 181507 - IOP331 Controller Module
  • Metso A413141 - BIU82 Binary Input Module
  • Metso KSD7447686 - Pneumatic Cylinder 5" Bore
  • Metso APL3003850 - Automation Component
  • Metso D201135L - Automation Controller
  • Metso A413125 - AIU8 Analog Input Module
  • Metso A413325 - IPU Power Unit
  • Metso 181573 - IOP346 PLC Module
  • Metso A413143 - BIU84 Binary Output Module Card
  • Metso A413152 - BOU82 Output Module
  • Metso PDP603 - Distributed Processing Unit 181555
  • Metso PDP601 - Distributed Processing Unit 181555
  • Metso A413040 - DCS Board DCU
  • Metso A413082 - CPU Processor Module
  • Valmet TI4W3 - Temperature Input Module
  • Valmet FI4S24 - Frequency Input Module
  • Metso 1064669615 - Fulcrum Bar
  • Valmet 181206 - IOP330 Digital Input Module