Product positioning
BECKHOFF EP23xx series EtherCAT Box module specification manual (version 3.102026-03-31), aimed at automation engineers, fully explains the model, parameters, wiring, installation, debugging, safety specifications, and certification information of IP67 protection level digital input/output modules.
Core positioning: Distributed digital I/O installed directly on industrial sites without the need for control cabinets.
Product series and model classification
1. Fixed I/O type
Model Channel Interface Output Current Input Filter
EP2308 4-in-4-out M8/M12 0.5A 3ms
EP2318 4-in-4-out M8/M12 0.5A 10 μ s
EP2328 4-in-4-out M8/M12 2A 3ms
EP2316 8-in-8-out ZS2001/D-Sub 0.5A 10 μ s
2. Configurable I/O type (any channel for input/output)
Model Maximum Channel Interface Output Current Filter
EP2338 8 M8/M12 0.5A 10μs/3ms
EP2339 16 M8/M12/ZS2001 0.5A 3ms
EP2349 16 M8/M12 0.5A 10μs
3. Special models
EP2339-01211:16 channel, grounded switch type (NPN output/input)
EP2338-2002: 8-channel, dual independent power supply (US/UP electrical isolation)
Core electrical parameters
power supply system
US: Control/Logic/Sensor Power Supply, 24V DC (-15%~+20%)
UP: Output driver power supply, 24V DC (-15%~+20%)
Maximum current: M8 interface 4A, 7/8 "interface 16A
Electrical isolation: 500V
Digital input
Signal level: 0: -3~+5V; 1:+11~+30V
Input current: 6mA
Filtering time: 10 μ s (high-speed)/3ms (standard)
Maximum wiring length: 30m
Digital output
Output type: 24V DC
Single channel current: 0.5A (EP2308/18/16/38/39); 2A(EP2328)
Total current: maximum 4A
Protection: short circuit, reverse polarity, overload
Switching time: 50~300 μ s

Structure and Installation
Protection level: IP65/IP66/IP67 (correct plug installation required)
housing dimensions
Narrow body: 126 × 30 × 26.5mm
Wide body: 126 × 60 × 26.5mm
Installation method
Fix directly with M3/M4 screws
Suitable for ZS5300 series installation guide rail
Grounding requirements: EP23xx-002x/0042 must be functionally grounded to ensure low impedance connection.
Interface specifications
EtherCAT: 2 × M8/M12 (4-pin, A/D encoding), green connector
Power supply: M8 or 7/8 ", black connector
M8:1=US,2=UP,3=GNDS,4=GNDP
7/8 ": 1=GNDP, 2=GNDS, 3=Ground, 4=US, 5=UP
I/O connectors: M8 (3/4 pin), M12 (5 pin) ZS2001、D-Sub25
Function and fault handling
Configurable channel: EP2338/39/49 No need to set, output automatically reads back to input image
Security function (EP2316 exclusive)
When there is a network failure, the output enters a safe state (can be set to OFF/ON)
Short circuit can be set to single channel shutdown or full shutdown
Diagnostic function
LED: US/UP power supply, RUN, L/A link, channel status
Process data includes synchronization errors, channel failures, and activation of safety status
Certification and Environmental Conditions
Certification: CE, cURus, ATEX/UKEX, IECEx
Explosion proof: II 3G Ex ec IIC T4 Gc; II 3D Ex tc IIIC T135℃ Dc
environment
Working temperature: -25~+60 ℃ (UL: -25~+55 ℃); Explosion proof: 0~+55 ℃)
Vibration: 5g (5~500Hz); Impact: 35g, 11ms
EMC:EN 61000-6-2 / EN 61000-6-4
8、 Debugging and Configuration
Integrated into TwinCAT, supporting CoE
Factory Recovery: CoE 1011:01 Write 1684107116
Inductive loads require built-in freewheeling diodes to absorb the reverse peak
Key issues
Question 1: Who is the dual power supply for the US and UP of the EP23xx module supplied to, and what are the advantages of separate power supply?
answer:
US: Provides power to EtherCAT bus, processor, digital inputs, and sensors.
UP: Power the digital output driver.
Advantages: Output faults/power outages do not affect the bus and input, achieving safe shutdown of output and improving system reliability.
Question 2: What are the core differences and applicable scenarios between EP2338/39 configurable I/O and EP2308/18 fixed I/O?
answer:
Fixed I/O: Fixed input and output quantity, low cost, intuitive wiring, suitable for standard I/O requirements.
Configurable I/O: Each channel can be freely used as input or output, with high flexibility, suitable for modification, testing, and non-standard equipment.
Question 3: What explosion-proof certifications does EP23xx meet? What mandatory conditions must be followed for use in explosion-proof environments?
answer:
Certification: ATEX, IECEx, UKEX, Level II 3G Gc/II 3D Dc.
Mandatory conditions: BG2000 protective case must be installed, ambient temperature must be between 0~+55 ℃, power must be turned off before insertion and removal, SELV/PELV safety power supply must be required.

K-JIANG
Add: Jimei North Road, Jimei District, Xiamen, Fujian, China
Tell:+86-15305925923