BENDER IRDH265 / IRDH365(ISOMETER ®) Insulation monitoring device

From: | Author:Wang | Time :2026-10-14 | 4 visit: | 🔊 Click to read aloud ❚❚ ▶ | Share:

BENDER IRDH265 / IRDH365(ISOMETER ®) Insulation monitoring device

Product positioning and core functions

Applicable system: IT isolated power supply system; Can handle AC/DC hybrid systems with rectifiers and frequency converters; External couplers can be used to extend the voltage level of the tested system.

Core measurement principle: AMP adaptive measurement pulse superimposes positive and negative symmetrical pulse measurement voltage onto the system to calculate the system's insulation resistance to ground; The measurement accuracy is not affected by the system's ground leakage capacitance, and the response time will become longer as the leakage capacitance increases.

Main abilities

Dual level insulation alarm ALARM1, ALARM2, with adjustable resistance of 10-990   k Ω;

LCD displays insulation resistance values, which can distinguish between AC ground faults, DC L+ground faults, and DC L - ground fault locations;

Relay 2-channel conversion output, contacts normally open NO/normally closed NC software configurable;

Connection monitoring: detect PE/tested system wiring disconnection and poor contact;

Automatic self check: Version 3 and 4 models automatically self check every 24 hours when the insulation resistance is much higher than the threshold;

RS-485 serial interface outputs measurement data and alarm status;

M+/M - Analog output 0-400 μ A, external pointer insulation meter;

Password protection to prevent parameter tampering;

TEST/RESET composite button: short press reset, long press>2s machine function self-test; Support external TEST/RESET terminals.

Differences in hardware form

Model Installation Method Shell Weight

IRDH265 DIN rail/screw fixed rail yellow shell 825g

IRDH365 panel embedded 144 × 72 perforated panel black shell 1075   g

Important security rule: Only one activated ISOMETER insulation monitoring device is allowed to be connected to the same interconnected IT system; Before conducting the withstand voltage insulation test, the connection between this device and the tested system must be disconnected.

Terminal definition

Power supply

A1 (+), A2 (-): Auxiliary power supply Us; it is recommended to equip the front end with a 6A fuse.

Measurement circuit

L1, L2, L3/L (+), L (-): Connect to IT system three-phase/DC two poles;

KE: The protective grounding PE must be reliably grounded and cannot be disconnected;

AK: coupler interface, external AGH series high-voltage coupling device;

Signal terminal

M+/M ---: Simulate 0-400 μ A output and connect an external insulation measurement meter;

<LT>: External reset/test, normally closed contact; Terminal short circuit fault memory latch takes effect, open circuit does not latch;

<PT>: Reserved;

A. B: RS-485 communication;

11-12-14: Alarm 1 relay conversion contact;

21-22-24: Alarm 2 relay conversion contact.

Panel human-machine components

LCD screen: displays AL1 preset threshold, current insulation resistance, fault type (R AC fault/R+L+ground/R-L ground/Rs being measured)

ALARM1, ALARM2 yellow alarm LED;

TEST/RESET button;

Up, down, left, right navigation buttons;

Key Logic

Short press TEST/RESET (< 1   s): Reset alarm;

Long press TEST/RESET (>2 seconds): Start internal self-test; Self check shows' TEST OK 'as normal; The system displays TEST ALARM due to a ground fault.


Three layer menu system Setup 1/Setup 2/Setup 3

During parameter modification, insulation monitoring will temporarily pause; After 10 minutes of inactivity, the measurement interface will automatically return, and the parameters will be automatically saved to the EEPROM non-volatile memory.

Setup 1 [Basic Settings]

Password switch;

Set two-level alarm thresholds ALARM1 and ALARM2 (10~990k Ω);

Set two relay contact modes NO/NC;

Enter the Setup 2 expert menu switch.

Setup 2 [Extended Expert Settings]

Alarm fault type selection (ALARM1/ALARM2)

AC or DC: Alarm for both AC and DC faults;

Only AC: responds to communication faults only;

Only DC: responds to single pole DC grounding;

ONLY DC+/ONLY DC ---: only responds to L+or L --- single pole grounding;

SYST-TEST: Only system hardware fault alarm;

Choose AGH-AK80/AK160 as the coupler model;

Wiring connection monitoring switch;

Relay output flashing function (1Hz pulse output);

Check if the relay is activated during the self checking process;

Alarm delay switch, with a delay time of 1-10 seconds;

Set the maximum ground leakage capacitance CE MAX of the system (up to 500 μ F); The larger the leakage capacitance, the longer the measurement cycle;

Password setting, factory reset, and software version reading.

Setup 3 [Advanced Setting of Measurement Principles, Only Version 3-4]

Four measurement modes can be switched:

AMP (factory default): adaptive pulse measurement, universal for both AC and DC;

DC: Stacked with 27V DC measurement voltage, only suitable for pure AC systems;

UG/AMP: Rapid detection of asymmetric DC faults;

AMP/UG: AMP main measurement overlay asymmetric fast detection; DC fault quick response current can be set to 0.1~5mA.

External matching coupler AGH series (extended high voltage)

The upper limit of direct measurement for this machine body is AC 793V, DC 650V; Paired with couplers, it can expand high-voltage IT systems:

AGH204S-4: AC maximum 1650V with rectifier load system;

AGH520S: AC up to 7200V pure AC IT;

AGH150W-4: DC maximum 1760V DC IT.

The coupler is connected to the host through the AK terminal, and the corresponding AK80/AK160 parameters must be selected in the menu.


Communication interface RS-485

Electrical: Non isolated RS-485 (terminals A/B), maximum bus length of 1200mm;

Parameters: 9600 baud, 8 data bits, 1 start bit, 1 stop bit;

Output format: Continuously send ASCII data frames; Including measuring insulation resistance, ALARM1 threshold, ALARM2 threshold, relay status, and fault type; Can be connected to an upper computer or text display to read the insulation status.


Key technical parameters

Tested system

Direct connection host: AC 0-793V, DC 0-650V, frequency 50-400Hz;

Alarm setting range: 10   k Ω~990   k Ω; hysteresis of about 25%;

The maximum system leakage capacitance to ground is up to 500 μ F;

Multiple versions of auxiliary power supply units are available with AC/DC options; The overall power consumption is ≤ 6   VA;

Relay output: two conversion contacts; AC250V / DC300V; Mechanical lifespan of 12000 cycles;

Environment: working -10~+55 ℃, storage -40~+70 ℃, climate level 3K5;

Anti interference: Complies with IEC 61000, EMC Class A industrial grade; The impact and vibration meet the requirements of IEC 60068;

Certification: IEC 61557-8 UL Listed、CE;

Analog output M+/M ---: 0-400 μ A corresponds to 0-100% range, without electrical isolation; To connect to a PLC, an isolation converter RK170 must be equipped.


Fault Information Description

ALARM E-KE: PE protection ground wire wiring abnormality;

ALARM L1-L3: All measurement wiring to the IT system is disconnected;

TEST ALARM: Ground fault detected during self check process;

If system faults are repeatedly reported: power off and restart; Still reproducing represents hardware damage to the device.

Wiring monitoring only alarms when all measurement leads are disconnected, and a single disconnection does not necessarily report a fault.


Ordering model and peripherals

The suffix meaning of the host version: -3/-4/-7/-8, corresponding to different insulation ranges and maximum leakage capacitance;

Peripheral: AGH high-voltage coupler; 72 × 72/96 × 96 external insulation indicator; RK170 isolated signal converter.


Important usage precautions

Before the voltage/insulation test, all connections between IRDH265/365 and the IT system must be disconnected, otherwise the device will be damaged;

The same IT isolated power grid only allows one ISOMETER host to be put into measurement, and multiple parallel connections may cause measurement abnormalities;

KE terminal PE ground wire is not allowed to be plugged or unplugged with power on;

AC/DC hybrid rectifier load: The rectifier must have a load current of>5-10 mA for DC side grounding faults to be detected correctly;

The larger the leakage capacitance of the system to the ground, the longer the measurement response time of the device, and the selection should confirm the on-site system CE parameters;

The M+/M - analog output is not isolated, and an isolation conversion module must be used when connecting to a PLC.


Typical application scenarios

Medical IT isolation power supply system;

Non grounded DC/AC/DC hybrid power grid for ships and rail transit;

Inverter, inverter intermediate DC circuit IT system;

Industrial isolation UPS, online monitoring of insulation status of ungrounded power supply.

  • Siemens 6SL3244-0SA01-1AA0 - SINAMICS G120 Control Unit
  • DANFOSS 175Z2688 - COATEDE CONTROLUNIT VLT5000
  • SIEMENS 6FM1721-3AA20 - Positioning Module
  • REXORTH VTS0605 PVAR S21 - Drive Module
  • BECKHOFF 2915-0000 - Control Module
  • COOPER EATON CGLine 400 40071347901 - CEAG CG Controller
  • SIEMENS 3UF5031-3AN00-1 - SIMOCODE DP Basic Unit
  • SIGMATEK DNC305 05-011-305 - Drive Controller
  • Multivac MV1 10249768 - Control Module
  • SCHNEIDER ELECTRIC MES114 59646 & 59645 - Circuit Breaker Accessory
  • CAMILLE BAUER CAPAX 44-580-0012 - Transmitter
  • HENGSTLER VT360P LS1/TOK - Encoder
  • BURKERT 8792 - 24V DC IP65 / IP67 Positioner
  • SENSOPART V10-OB-A1-W6 - Vision Sensor
  • ALLEN-BRADLEY 1762-L40BXB SER.C REV.J - MicroLogix 1200 Controller
  • HITACHI CPU22-02HC 33025801-2 - CPU Module
  • HITACHI AGH-0 33034810-2 - Control Board
  • PHILIPS AIH110 VER 1.0 - Control Module
  • BAUMULLER DO8000 - Drive Controller
  • B&R PS477 3PS477.9 Rev.C0 - Power Supply
  • ABB ALFA LAVAL 200-CISB - Communication Interface 2 x SatBus
  • Moeller MI4-570-TA1 - HMI Operator Panel
  • ABB ACH550-01-06A9-4+B055 - Variable Frequency Drive
  • ABB TPU2 3HNE00313-1 REV 12 - Teach Pendant Unit
  • Schneider Electric BRS368H130ABA - Stepper Motor
  • Foxboro FCM100E P0972ZA - I/A Series Communication Module
  • Siemens 6ES7 450-1AP00-0AE0 6ES7450-1AP00-0AE0 - Simatic S7 Version:04 Counter Module
  • Schneider Electric ATV320U07N4W - Altivar Machine Drive
  • Priva TouchPoint Flush V06:02 5060002 - Control Panel
  • Lenze ESMD402L4TXA - 4kW SMD Inverter Drive
  • Lenze ESMD402L4TXA - 4kW SMD Inverter Drive
  • Schneider Electric PM210 PM210MG - Powerlogic Power Meter
  • ASCOM U982-DB/1C U982 - Power Supply / Communication Module
  • DYADIC SYSTEMS SCN5-010-050-S03-NA - Servo Cylinder
  • Reliance Electric GMI-S04 - AC/AC CONVERTER 380/400V 50/60Hz 3.9/5.2A
  • Pro-Face GLC150-BG41-XY32KF-24V 3080060 PFXGLC150BDBP - Touch Screen HMI
  • ROFIN RSL TERMINAL V2 0185.01/03 - TERMINAL
  • HONEYWELL R7241E1077 - Burner Control / Amplifier
  • SEW MM22C-503-00 8241201 - 2.2kW Movimot Drive
  • Brand Digital III 50mL - Burette
  • Danfoss 195N0039 VLT2811PS2B20STR1DBF00A00C0 - 2.4kVA VLT Drive
  • SONY LG10-2 EK1 - Digital Gauge Indicator
  • EMERSON SKD3400750 - 7.5kW AC Drive
  • SIEMENS 6AV6 542-0AG10-0AX0 - MULTIPANEL HMI
  • TELEMECANIQUE ATV21HU55N4 - ALTIVAR21 5.5KW Variable Speed Drive
  • MITSUBISHI A985GOT-TBA-EU - GOT900 Touch Screen HMI
  • SCHNEIDER LXM32AD30N4 - Lexium 32 Servo Drive
  • SICK PSR01-1501 M20Z-02550A122 - Safety Laser Scanner
  • GECMA CHALLENGER 15-2-FMO - LITE TOUCH Monitor
  • Uniop EK02 6ZA982 - HMI Operator Panel
  • TELEMECANIQUE ATV18U54M2 - SQUARE D ALTIVAR 18 3kW Drive
  • Schneider Electric ATV312HU75S6 - 7.5kW Altivar 312 Drive
  • Siemens 6GK7243-5DX30-0XE0 6GK7 243-5DX30-0XE0 - Communications Processor
  • Schneider Electric LV432455 VIGI630 - 3POLE Earth Leakage Module
  • Rexroth PSI 6100.750 L1 R911170694-107 - frequency inverter / inverter
  • SWEDISH MICROWAVE AB Ku-Band BDC 138010-45-D0 - Block Downconverter
  • METTLER TOLEDO IND429 IND429-BB30 - Weighing Terminal
  • Siemens 6SL3210-5HE10-4UF0 - Sinamics V90 Servo Drive
  • B&R X20CP0482 Rev.D0 - X20 CPU Module
  • Mitsubishi FR-E720S-110SC-EC FRE720S110SCEC - 31A~11A Drive With Filter
  • ABB ACH580-01-026A-4 - Variable Frequency Drive
  • Siemens 6SL3210-1KE13-2AP1 - SINAMIC G120CDP 1.1kw Drive
  • Schneider Electric TM250D 4P3D LV431440 - Compact NSX250 Circuit Breaker
  • RELIANCE ELECTRIC GD.722.81.00-A 802288-74C - MAXITRON Servo Control Card
  • Uniop EK02 6ZA982 - HMI Operator Panel
  • Siemens 6SE9113-7JA13 - MICRO MASTER Junior 1.5kW Inverter
  • Mitsubishi FR-E720S-110SC-EC FRE720S110SCEC - 31A~11A Drive with Filter
  • Johnson Controls FEC2621 MS-FEC2621-0 - Field Equipment Controller
  • BENDER IR475LYT-429 - A-ISOMETER Insulation Monitor
  • Berger lahr D550 RS15 22.550-00-30b - Stepper Drive
  • Rexroth PSI 6100.750 L1 R911170694-107 - Frequency Inverter / INVERTER
  • KOYO 205 D2-06B-1 D2-240 H2-ECOM D2-08ND3 F2-08TRS - DIRECT LOGIC PLC WITH MODULE
  • TELEMECANIQUE ATV18U54M2 ATV18U54M - SQUARE D ALTIVAR 18 3kW Drive
  • Lenze 471-E1.D - Board / Controller Speed
  • Mitsubishi FR-A740-00038-EC - Frequency Inverter
  • Johnson Controls IOM3723 MS-IOM3723-0 - Input/Output Module
  • CURTIS 1238-5602 - AC Motor Controller
  • FOXBORO P0912XX REV.A - 220VAC Power Supply
  • Siemens 6SE9113-7JA13 - MICRO MASTER Junior 1.5kW Inverter
  • Mitsubishi FR-A740-00038-EC - Frequency Inverter
  • KOYO 205 D2-06B-1 D2-240 H2-ECOM D2-08ND3 F2-08TRS - DIRECT LOGIC PLC WITH MODULE
  • AUTZ M406D-00101 - Servo Motor
  • Lauer PCS095 PG095.508.BB - Operator Panel
  • ABB SCOP45SB/DX232 - SattCon OP45 SB Operator Panel
  • SEW Eurodrive MCH42A0030-5A3-4-00 MDX60A0030-5A3-4-00 - 4.8kVA Movidrive Inverter
  • BENDER IR475LYT-429 - A-ISOMETER Insulation Monitor
  • Johnson Controls FEC2621 MS-FEC2621-0 - Field Equipment Controller
  • Johnson Controls IOM3723 MS-IOM3723-0 - Input/Output Module
  • Berger lahr D550 RS15 22550-00-30b - Stepper Drive
  • SIEMENS 6FX1120-4BD03 6FX11204BD03 5702049304.00 E-Stand: A - Sinumerik Module
  • Allen-Bradley 1771-NIV B - HIGH RESOLUTION ISOLATED ANALOG SERIES Module
  • HONEYWELL XFC2D06001 - Flow Computer / Controller
  • Contraves Varidyn Compact ADB 380.90M - DC Drive 380v - 400v 90A 50kVA
  • Red Lion Control GEM52000 - Control Module
  • Siemens 6ES5 955-3NC13 - modular power supply TYPE:DIN41752
  • Danfoss ICV50 G20Mn50T / 027H5200 - Valve zaw
  • Eberle PLS508 P-814 / 2X EA-88 / A-812 / MT-81 / S-11 - PLC with Modules
  • Siemens 6ES7 314-6CF01-0AB0 6ES7314-6CF01-0AB0 - SIMATIC CPU314C-2 DP
  • EBERLE EM-525-87 EM52487 - ICE DETECTOR BASE UNIT
  • Telemecanique / Schneider TSXRKZ02 - TSX Micro automation plus 7module
  • B&R 5DLSDL.1001-00 - Display Link Receiver
  • Siemens 6FX1120-4BD03 6FX11204BD03 5702049304.00 E-Stand: A - Sinumerik Module
  • ALLEN-BRADLEY 1771-NIV A - HIGH RESOLUTION ISOLATED ANALOG SERIES Module
  • ALLEN-BRADLEY 1771-NIV B - HIGH RESOLUTION ISOLATED ANALOG SERIES Module
  • Contraves Varidyn Compact ADB 380.90M - DC Drive 380V - 400V 90A 50kVA
  • Contraves Varidyn Compact ADB 380.90M - DC Drive 380V - 400V 90A 50kVA
  • Ropex RES-202 - Resistron Temperature Controller
  • HONEYWELL XFC2D06001 - Flow Computer / Controller
  • Telemechanics ATV452U40 - DIMMER ALTIVAR5 SERIES 452 4kW 5HP Frequency Inverter
  • VEGA VEGAPLUS61 PS61.XXAGPHAMAX - Radar Level Sensor
  • BRANSON ULTRASONIC TRANSDUCER - Ultrasonic Transducer
  • Danfoss ICV50 G20Mn50T / 027H5200 - Valve Valvola Zaw
  • Schneider Electric 2001549/1 GALAXY PW 5102851200 NT07 - panler card
  • REXROTH VT3006-36 A - Proportional Valve Amplifier
  • Allen-Bradley 1746-OBP16 SERIES:C - SLC 500 OUTPUT MODULE
  • SCHNEIDER LXM32MD12N4 - Lexium 32 Servo Drive
  • Schneider Electric ATV630U22N4 - 2.2KW Altivar Process Drive
  • Allen-Bradley 1746-OBP16 SERIES:C - SLC 500 OUTPUT MODULE
  • Vanderlande 0E2550-00002... - Bagtrax Integrated Power Module 400V 32A
  • B&R X20CP0410 Rev.D0 - X20 CPU Module
  • VANDERLANDE 0E2550-00002 02EDD2B0100 - BAGTRAX Integrated Power Module 400V 32A
  • Rexroth R061205010 - Linear Bushing / Bearing
  • INDRAMAT TVM1.2-50-220/300-W0-220/380 - Power Supply Module
  • Vanderlande 0E2550-00002... - Bagtrax Integrated Power Module 400V 32A
  • HOMAG KEB 07F5S1A-YA00 09E5T60-1001 - Combivert Inverter WITH KEYPAID AND FILTER
  • Siemens 3RW3047-1BB14 - Soft Starter
  • Sumitomo AF-500 AF502-A40 - 0.4kW Transistor Inverter
  • Sumitomo AF-500 AF502-A40 - 0.4kW Transistor Inverter