Operation Manual for Basler BE1-32R/BE1-32O/U Direction Power Relay

General information (product positioning, seven major application scenarios, model code, complete electrical specifications)

1. Core positioning of the product

Two solid-state relays calculate the active power P=EIcos θ by collecting system voltage and current, and determine the power flow direction. They are used for over power, under power, and reverse power protection in single-phase/three-phase power grids; BE1-32R only detects unidirectional over/reverse power; BE1-32O/U integrated dual detection of over power and under power; It is not recommended to use it under the condition of power factor<0.1.

2. Seven typical industrial application scenarios

Anti motor operation (reverse power protection)

The synchronous generator loses its prime mover and is dragged by the power grid to become an electric motor, which can damage the steam turbine, diesel engine, and gas turbine; The table shows the setting intervals for reverse power protection of different prime movers: 0.2~2% rated kW for water turbines, 0.5~3% for steam turbines, up to 25% for diesel engines, and up to 50% for gas turbines; Configurable delay to avoid transient errors in grid connection.

Distributed parallel control (cogeneration)

Automatically start the generator when the incoming power of the power grid exceeds the limit; The power grid will automatically shut down when the power is too low, and BE1-32O/U will simultaneously achieve over/under generation monitoring.

Generator overload protection

Power exceeding the limit triggers an alarm, load shedding, and starts the standby unit.

Contact transformer/distribution network protection

Monitor the power flow of two main transformers to prevent reverse power transmission and overload.

Unit delay electrical tripping

When a large steam turbine unit trips due to non electrical faults, the circuit breaker is delayed and the residual steam in the pipeline is discharged.

Circuit breaker position monitoring

After the incoming switch is disconnected, the power is reversed and the interlocking circuit is opened for isolation.

Reactive power (Var) monitoring

By adjusting the phase shift of the collected voltage by 90 °, the active power relay is modified for reactive power flow monitoring to identify generator demagnetization conditions.

3. Model and style coding rules

The complete identification of the device consists of the model and style number, printed on the panel, plug-in base, and inside the chassis; Style code segmentation definition: collect input type, power measurement range, output contact type, power supply specifications, timing type, action indicator, auxiliary output, installation method, etc., with code disassembly examples attached.

Collect 5 types of inputs:

A: Single phase voltage+single phase current (no phase sequence sensitivity)

B/V: Line voltage+single-phase current (60Hz B, 50Hz V, phase sequence sensitive)

C: Three phase line voltage+single-phase current (no phase sequence sensitivity)

D: Three phase phase voltage+three-phase current (no phase sequence sensitivity)

E: Two phase current+three-phase line voltage (two watt meter method, phase sequence sensitive)

4. Complete set of electrical performance specifications

(1) Current/voltage acquisition circuit

Adapt to standard 5A secondary CT; collect ranges in multiple stages, distinguish between continuous, 1-minute, and 1-second short-term overload currents;

The voltage is taken from PT secondary, with a continuous withstand voltage of 150% of the rated voltage, and the collected load is less than 1VA;

Detailed table of CT circuit impedance (Burden) for each gear, used for CT secondary load verification.

(2) Action indicator (Target)

Optional built-in driver/current driven type; Current driven type with a minimum operating current of 200mA, electronic latch LED, and manual panel reset; Turn off the power and restore the locked state when powered on.

(3) Output contact capacity

Distinguish between AC resistive, DC resistive, and inductive load rated currents, support normally open NO/normally closed NC/SPDT auxiliary contacts, and power status monitoring contacts.

(4) Power supply

4 types of power supply specifications (24Vdc/48Vdc/125Vdc&120Vac/250Vdc&240Vac), indicating power consumption and input voltage range; The minimum starting voltage of R-type 24Vdc is 14V, and it can be as low as 12V after operation.

(5) Action accuracy

Single phase: When PF=1, the error is ± 2% of the set value; ± 5% when 0.5<PF<1;

Three phase: ± 2% when PF=1, ± 5% when 0.5<PF<1;

Return value: 95% reliable return of action value.

(6) Temporal characteristics (three temporal modes)

Instantaneous type: Under 2 times the operating power, 60Hz response<80ms, 50Hz<100ms; Under power instantaneous response is faster (< 50ms@60Hz );

Definite Time: 0.1~9.9s (x 0.1 magnification), 1~99s (x 1 magnification), 00 gear=instantaneous; Timing error ± 5% or 50ms;

Inverse Time: Only available for over power, multiple sets of standard inverse time curves, panel dial 01-99 to select the curve.

(7) Power setting range

The table lists all high and low range power settings (0.5W~6000W range) for single-phase/three-phase, 120V/208/240V.

(8) Environmental and Mechanical, Type Testing

Temperature: Operating -40 ℃~+70 ℃; Storage -65 ℃~100 ℃;

Anti vibration: 10-500Hz 2G three-axis vibration; Impact resistance: 15G three-axis;

Insulation withstand voltage, surge immunity, and radio frequency immunity comply with IEEE and IEC standards;

Weight: S1 shell has a maximum weight of 13.5lb, M1 shell has a maximum weight of 18.5lb.

Front Panel Controls

All tuning components, indicator lights, and reset buttons are concentrated on the front panel, including:

Range switch (high/low power mode);

Overpower dip delay and delay multiplier switch (0.1/1.0);

Overpower gear adjustment knob (Tap);

Underpower potentiometer (10%~95% over power setting);

Two action indicator lights (Over/Under Pickup LED) and power indicator light;

Action indicator reset button;

Output test hidden button (non-metallic rod manually triggers verification output);

The gear power comparison table is printed on the panel.


Functional principle explanation

Signal acquisition process

CT/PT collects current and voltage and sends it to the internal kW multiplication converter to calculate the actual active power. It outputs a DC analog voltage and sends it to the comparator, which compares it with the panel setting threshold to trigger the timing circuit, output relay, and latch indicator.

Phase sequence sensitivity

The B/V/E acquisition method is sensitive to the phase sequence of ABC/ACB, and the wiring must match the phase sequence; There is no phase sequence requirement for A/C/D.

Classification of output circuits

Main protection output: independent contacts for over power and under power;

Auxiliary output: optional NO/NC/SPDT;

Power status monitoring: Contact displacement in case of power loss; Inserting or unplugging the base will result in a short circuit status output.

Power and indicator logic

The whole machine is isolated from a wide power supply and has no polarity; The electronic latch indicator can only be manually reset, temporarily extinguished when powered off, and restored when powered on.


Installation, wiring, maintenance, and storage

1. Installation specifications

Solid state without mechanical structure, no mandatory requirement for vertical installation; Provide three views of the semi embedded and protruding installation hole dimensions and the overall appearance of the S1 and M1 shells; The installation screw specifications and panel opening drawings are complete.

2. Wiring specifications

Main circuit wiring ≥ 14AWG, grounding ≥ 12AWG independent ground wire;

Divided into five categories of drawings: control circuit diagram, internal wiring for 5 types of acquisition, BE1-32R/BE1-32O/U external standard wiring, and on-site wiring diagram for 5 types of acquisition methods;

Before the pressure test, the plug must be unplugged and the core must be extracted to prevent equipment damage; The current driven indicator trip circuit must ensure a current of ≥ 200mA.

3. Maintenance and Repair

No regular preventive maintenance, only complete machine calibration is conducted on a periodic basis;

The circuit board does not support on-site maintenance, and if there is a malfunction, the plug-in core can be replaced directly; Repair requires contacting the manufacturer for authorization;

Supporting dedicated test plug: internal circuit can be verified online without removing the device.

4. Storage requirements

Idle equipment is powered on for 30 minutes every year to extend the lifespan of electrolytic capacitors; The storage environment should be dust-proof and moisture-proof.


Whole machine verification testing process

Provide standardized on-site verification steps, with 5 dedicated testing wiring diagrams for collection methods, covering all verification items:

Overpower action/return value verification (unity power factor);

Underpower action/return value verification;

Instantaneous action time test;

Time limited delay accuracy test (separated over/under power);

Verification of over power inverse time limit curve;

Each test provides panel tuning parameters, standard qualified error range, and power conversion formula (different power calculation formulas correspond to different acquisition types).

  • ADLINK PCI-8134 - 51-12403-0B20 PCB Board Motion Controller Card
  • ADLINK LPCI-3488A - PCI Card 51-12801-0A30 Low Profile IEEE-488 GPIB Card
  • ADLINK NUPRO-900A - industrial computer motherboard Single Board Computer
  • ADLINK cPCI-6840V - industrial control motherboard CompactPCI SBC
  • ADLINK M-342 - industrial motherboard ATX Mainboard
  • ADLINK NUPRO-935A/LV - industrial control motherboard
  • ADLINK cPCI-3538 - CompactPCI Async Serial Communications Module
  • ADLINK PCI-1610 - Card 4-Port RS-232 PCI Serial Communication Card
  • ADLINK HSL-DI32-DB-N - Distributed I/O Module 32-CH Digital Input
  • ADLINK CPCI-6860A - motherboard E7501 CompactPCI Single Board Computer
  • ADLINK PCI-8134A - 4-Axis Motion Control Card PCB Board
  • ADLINK EURESYS LINK - grabbers Video Capture Card Frame Grabber
  • ADLINK NuPRO-965DV - motherboard Industrial Control Board
  • Thermo Fisher Scientific 80100-60500 - 80000-61010R 80000-21000R 80000-60457 Spectrum System Controller ADLINK Components
  • ADLINK PCI-7296 - IO card High Density 96-CH Opto-Isolated DIO Card
  • ADLINK MXC-6322D - Matrix Industrial Computer Fanless Embedded PC
  • ADLINK DIN-825-GP4 - connector board Terminal Block Interface
  • ADLINK AMP-208C - Motion Control Card DSP-based 8-axis
  • ADLINK PCIe-GIE72 - 51-18531-0A10 2-CH GigE Vision Frame Grabber PoE+ Card
  • ADLINK PXIS-3320 - PXI/PXIe Chassis 15-slot 6U PXI/CompactPCI SEM-I-1518=9N41
  • ADLINK MI-965 - Industrial CPU Motherboard
  • ADLINK M-302 - Industrial control motherboard
  • ADLINK PCI-6308V - 51-12202-0A50 Isolated Analog Output Card PCB-I-E-1813=ZA03
  • ADLINK NUPRO-935A - Industrial Mother Board CPU Board
  • ADLINK PCI-7434 - PLOTECH Digital Output Card PCB-I-E-1182=6EX2
  • ADLINK PCI-7432 - 64 Channel Isolated Digital I/O PCI CARD
  • ADLINK NUPRO-935A/DV - 51-41802-0A10 motherboard Industrial Control Board
  • ADLINK PCIe-GIE72 - 51-18531-0A10 2-CH GigE Vision Frame Grabber PoE+ Card
  • ADLINK HSL-DI16DO16-M-NN - HSL-DI16DO16-M-NN(G)-0280 Discrete I/O Module Distributed I/O
  • ADLINK cPCI-6760D / cPCI-6840V - cPCI Single Board Computer Industrial Motherboard
  • ADLINK NuPRO-A301 - Motherboard IPC Motherboard
  • ADLINK NuPRO-935A/LV - motherboard Industrial Control Board
  • ADLINK NUPRO-E320LV - motherboard Industrial Control Board
  • ADLINK NuPRO-E42 - Industrial Control Board Motherboard
  • ADLINK M-342 - ATX Motherboard Industrial PC Mainboard
  • ADLINK CPCI-6860 / 6860A - Industrial Control Motherboard CompactPCI SBC
  • ADLINK AmITX-SL-G-Q170/GEHC(EA)-021E - 51-7A104-0A20 Industrial Motherboard w/ DDR4
  • ADLINK NUPRO-852 / NUPRO-852LV - industrial control motherboard
  • ADLINK DAQ-2006-004 - Multi-Function DAQ Cards Data Acquisition
  • ADLINK PCIe-RTV24 - Frame Grabbers Video Capture Cards PCI-e x1 4-CH 120fps
  • ADLINK PCI-8134 - 51-12403-0B20 4-Axis Motion Controller Card
  • ADLINK PCI-8132 - 2-Axis Motion Controller Card
  • ADLINK cBP-6402 - Backplane Passive Backplane
  • ADLINK cPCI-6760D - cPCI Single Board Computer Industrial Control Motherboard
  • ADLINK DIN-825-4PO(G)-0030 - Terminal Board Motion Control Breakout Board
  • ADLINK M-322 - Industrial Motherboard
  • ADLINK ABX-1301 - 51-63808-0A20 Industrial Motherboard
  • ADLINK PCI-7433 - 64-CH Isolated Digital Input Card
  • ADLINK AMP-208C - Motion Control card
  • ADLINK DIN-50S-01 - TECHNOLOGY TERMINAL BLOCK INTERFACE MODULES W/ DIN RAIL
  • ADLINK PCI-8134 - 51-12403-0B20 4-Axis Motion Controller Card
  • ADLINK MXE-201/MSSD64G - Technology Automation Computer Fanless Embedded System
  • ADLINK USB-3488A (G) - USB to GPIB CARD Controller Interface
  • ADLINK cPCI-3720L2 - SBC Single Board Computer PCB AMAT 0190-14599
  • ADLINK PCI-7251 - Relay Output Board Expansion Module
  • ADLINK PCI-8124-C - PCB Board 4-CH Encoder Trigger Card
  • ADLINK HD636 - Industrial Computer Board PCB-I-E-2200=9L32-2 Main Board
  • ADLINK USB-3488A - THERMOTRON INDUSTRIES IEEE 488 CPU INTERFACE WITH USB/GPIB
  • ADLINK MI-965 - motherboard Industrial CPU Board
  • ADLINK LPCIe-7250 - Technology Digital IO card Low Profile PCIe Relay Output
  • ADLINK NuPro-720/SCOPUS - Technology With 256MB Industrial MotherBoard
  • ADLINK NuPR0-840 - industrial control motherboard
  • ADLINK M-342 - Motherboard ATX PC Mainboard
  • ADLINK MI-965 - motherboard Industrial CPU Board
  • ADLINK CPCI-6530V/4402E/M4G - AMAT CPCI-6503VED/4402E/M4-0/SD64G-2550 Universal SBC
  • ADLINK IMB-M43-IRV - Industrial Motherboard ATX PC Board
  • ADLINK 52983 / 58183 - Chroma PXI I/O Input/Output Card + Carrier Adapter
  • ADLINK PXI-3920 - PXI 3U cPCI Industrial Controller w/ RAM SSD Embedded CPU
  • ADLINK NuPRO-842LV/P - motherboard Industrial Control PC Board
  • ADLINK PCI-7442 - 64-Channel Datalogging Acquisition Switch Card
  • ADLINK PCIe-RTV24 - Cadre Agrippeurs Vidéo de Capture Cartes Pci-E x1 4-CH
  • ADLINK ACL-7122A - TECHNOLOGY 51-11004-1A1 CIRCUIT BOARD 96-CH DIO Card
  • ADLINK PCIe-RTV24 - 51-18016-0A20 Image Acquisition Video Capture Card
  • ADLINK AMP-204C - DSP-Based 4-Axis Advanced Pulse-Train Motion Controller
  • ADLINK 52981 / 58183 - Chroma PXI Digital I/O DIO Input/Output Card + Carrier Adapter
  • ADLINK PCI-8102 - motion control card 2-Axis
  • ADLINK NuPRO-E320LV - industrial computer motherboard
  • ADLINK PCI-RTV24 - card Analog Video Capture Frame Grabber
  • ADLINK M-302 - Motherboard P/N: 08GSAQ96501102
  • ADLINK NEON-1020 - Smart camera Industrial Machine Vision
  • ADLINK AMP- 208C - card DSP-based 8-axis Motion Controller
  • ADLINK PCI-9114DG - Multi-Function Daq Card Data Acquisition
  • ADLINK MXC-6322D/BE_FanG) - Matrix PM2-MXC Fanless Embedded Computer
  • ADLINK DIN-825-4P0 - Terminal Board Motion Control Breakout Board
  • ADLINK HPCI-8S4 REV.B2 - Industrial Control Base Plate Passive Backplane
  • ADLINK HSL-DI32-DB-N - Distributed I/O Module 32-CH Digital Input
  • ADLINK NuPRO-935A/DV - industrial control motherboard
  • ADLINK PCI-7442 - Switch card 64-CH Datalogging Acquisition Card
  • ADLINK NuPRO-E42 - motherboard 51-41808-0A30 Industrial Motherboard
  • ADLINK CPCI-3610D/N45/M1G(G)-10B0 - CompactPCI Intel Atom Single Board Computer CPU Board
  • ADLINK LPCI-7250 - GP Output Isolated Digital Input Card PCB 51-12803-0A10
  • ADLINK PCI-7250 - 51-12007-0A40 PCI7250 8-CH Relay Output & 8-CH Isolated DI Card
  • ADLINK STC-1005 - 10.4inch touch panel PC E3845 CPU
  • ADLINK PCI-FIW64 - image card FireWire Frame Grabber
  • ADLINK NuPRO-935A/LV - industrial computer motherboard
  • ADLINK PCI-8164 00B0 - Centralized Motion Controller 4-axis PCB-I-E-1179=6EX2
  • ADLINK ACLD-9137F REV A1 - 51-14006-101 Screw Termination Board
  • ADLINK PCI-7248 - 51-12006-0A40 Control Card Digital I/O
  • ADLINK HPCI-8S4 - Technology Backplane PCB GaSonics 3500 Asher Passive Backplane
  • ADLINK NuPRO-E320LV - Cpu Board 51-41804-0A20 Industrial Motherboard
  • ADLINK HPX-13S4 - device baseboard Passive Backplane
  • ADLINK M-322 - industrial motherboard
  • ADLINK NuPRO-865 REV :3.0 - industrial motherboard
  • ADLINK DIN-68S-01 - Terminal Block Interface Module Cable Connection
  • ADLINK ETX-IM266-C100Z - motherboard ETX CPU Module
  • ADLINK NuPRO-E320LV - motherboard Industrial Control Board
  • ADLINK NuPRO-841 REV:2.0 - motherboard Industrial PC Board
  • ADLINK ETX-AT-N270-18 - N270 Board ASH-EAT-18/S512 ET Mainboard
  • ADLINK PCI-RTV24 - Image capture card Analog Frame Grabber
  • ADLINK PCI-8102 - card 2-Axis Motion Controller
  • ADLINK M-322 - industrial motherboard
  • ADLINK PCI-9114 REV.C2 - acquisition card Multi-Function DAQ
  • ADLINK NuPRO-865 REV :3.0 - industrial motherboard
  • ADLINK DIN-68S-01 - Terminal Block Interface Module Cable Connection
  • ADLINK M-322 - Industrial Motherboard Mainboard
  • ADLINK CPCI-6860A - E7501 dual Xeon CPCI Single Board Computer
  • ADLINK MXC-6301D(G) - Technology Expandable Fanless Embedded Computer i7-3610E
  • ADLINK NuPRO-842LV - 51-41360-0B1 Industrial Motherboard
  • ADLINK PBP-08A7 R1MO - PCB Industrial Computer Backplane Passive Backplane
  • ADLINK PCI-3488 - PCI BOARD IEEE-488 GPIB Controller Card
  • ADLINK NuPRO-935A/LV - Industrial Control Motherboard
  • ADLINK PCI-8134 - TECH 4-AXIS MOTION CONTROLLER 4209NB2039 AT23A
  • ADLINK Karbon 700-X2 - Expanded High-Performance Rugged Edge Computer Windows 10
  • ADLINK PCIe-9852 - ADcard 2-CH 8-Bit 200MS/s Digitizer Card
  • ADLINK ETX-BT-E3815 - Industrial Control Module NO AUDIO 91-71116-E020 CT66
  • ADLINK cPCI-8168-006 - cPCI NulPC Motion Control Board
  • ADLINK NuPRO-E43 - 51-41809-0A30 industrial motherboard
  • ADLINK PCI-8134A - PCB Board Motion Controller Card