Beckwith M-3425A Generator Integrated Protection Device Manual

From: | Author:Wang | Time :2026-06-29 | 6 visit: | 🔊 Click to read aloud ❚❚ | Share:

Beckwith M-3425A Generator Integrated Protection Device Manual

Product positioning and standard/optional hardware modules for the entire machine

1. Standard hardware configuration of the whole machine

Signal acquisition: 5 voltage inputs, 7 current inputs, supporting 1A/5A CT secondary specifications;

I/O basics: 6 programmable state inputs, 8 standard outputs (6 normally open+2 conversion contacts);

Communication interfaces: front panel RS232, back panel RS232, RS485; Standard COMTRADE/BECO waveform recording, capable of storing 416 cycles of fault data;

Event records: 32 fault action records with time stamps, 512 SOE event logs;

Measurement function: Real time measurement of three-phase voltage/current, sequence components, active/reactive/power factor, impedance;

Self diagnosis, IRIG-B clock synchronization, 4 independent constant value switching areas.

2. Optional extension accessories

M-3931 HMI human-machine interface: 2-line 24 character LCD panel, local setting of three-level permission password;

M-3925A Target fault indicator module: 24 protection action LEDs, visually distinguish fault types;

M-3921 excitation grounding coupler: equipped with 64F/64B rotor grounding and brush shedding protection;

Extended I/O: Extra 8 inputs+15 outputs (only available with IPScom software configuration);

Redundant power supply, RJ45 Ethernet (supporting Modbus TCP/IEC 61850);

Supporting tools: IPScom configuration software, IPSplus waveform analysis software, 20Hz low-frequency injection complete set of peripherals (signal generator, bandpass filter, dedicated CT, used for 64S stator 100% grounding protection).

3 Mechanical, Environmental, and Power Supply Specifications

Installation: Standard 19 inch rack, available in both standard and extended I/O heights, supporting horizontal/vertical cabinet installation; Provide opening size drawings;

Environment: Operating temperature -20 ℃~+70 ℃, storage -65~+100 ℃; Resistant to vibration and impact in accordance with IEC 60255;

Power supply: Wide AC/DC dual specifications (AC110/120/230V, DC24/48/125/250V), dual power supply for extended I/O models;

Safety regulations: UL508, CE, CSA certification, insulation withstand voltage, static/electric fast pulse surge meet EMC standards for power equipment;

Contact capacity: The tripping contact can be connected for a short period of 30A, with a continuous load capacity of 8A. The inductive load breaking capacity complies with ANSI C37.90.


Classification of Three Major Function Software Packages (Core Protection Function Classification)

(1) Base Package (standard for all models)

Covering conventional electrical fault protection for generators, including ANSI standard components:

24 Extreme Magnetic V/Hz Protection (Time Limit+Inverse Time Hyperbolic)

27 Three phase undervoltage (three-stage fixed value independent delay)

32 directional power (reverse power/low forward power/overload three levels, can be used for shutdown interlocking)

40 demagnetization protection (double offset Mjolz impedance circle, with low voltage acceleration trip)

46 Negative sequence overcurrent (timed+inverse timed to prevent rotor overheating)

50 instantaneous phase overcurrent, 50N instantaneous neutral overcurrent

50/27 Non synchronous false closing protection (voltage loss lockout overcurrent)

50BF circuit breaker failure protection

50DT phase separated timed overcurrent (can be used as split phase differential)

51V with voltage control/voltage constraint inverse time overcurrent

51N inverse time neutral overcurrent

59 three-phase overvoltage, 59N neutral point overvoltage, 59X multifunctional turn to turn/bus overvoltage

60FL PT fuse fault detection (internal logic+external input dual-mode, automatic locking misoperation protection)

67N residual direction overcurrent (zero sequence grounding directional protection)

81 Four band frequency high/low protection

87 phase current differential, 87GD zero sequence ground differential

IPSigmic programmable Boolean logic (with/or/without+delay, custom interlock trip)

Circuit breaker wear monitoring BM, trip circuit monitoring TCM

(2) Comprehensive protection package (added on top of the base package)

21 Three section Mjolz phase to phase distance protection (system backup, with load shielding, out of step locking)

27TN Third Harmonic Neutral Point Undervoltage (High Resistance Grounding 90% Stator Grounding)

49 stator thermal overload I ² t protection

78 out of step/oscillation protection (three zone Mjolz+blocking characteristics, sliding pole counting)

81A low-frequency cumulative timing (to prevent resonance fatigue of turbine blades)

81R frequency change rate df/dt low-frequency load shedding

(3) Optional ordering of independent protection function (factory optional, cannot be added later)

25. Simultaneous inspection (pressure/frequency/phase locking, closing logic of thermal/cold busbar)

64F rotor excitation grounding, 64B brush detachment detection (M-3921 coupler required)

64S 20Hz low-frequency injection type 100% stator grounding protection (complete set of external signal equipment matching)

Principles and Key Points of Setting Range for Each Core Protection Function

1. Voltage protection (27/59/27TN/59D/59N/59X)

27/59: Three phase independent three-stage fixed value, supporting two sampling algorithms: RMS wideband/DFT fundamental wave;

27TN/59D: Utilizing the third harmonic voltage difference on both sides of the stator to achieve grounding protection for most windings of a high impedance grounded generator;

59X: Open triangle 3V0 voltage monitoring, used for stator turn to turn short circuit and busbar grounding;

64S: External 20Hz low-frequency injection into the stator neutral point, achieving 100% stator grounding under all operating conditions of generator grid connection/shutdown, compensating for the blind spot of third harmonic protection.

2. Power and demagnetization protection (32/40)

32 directional power:

Negative value=reverse power (to prevent the generator from being pulled back by the prime mover and the motor from running);

Positive values are divided into low active power and overload; The third component can switch reactive power monitoring;

40 demagnetization: Dual offset Mohorz impedance characteristics distinguish between light load/full load demagnetization, shorten trip delay under low voltage conditions, and avoid system absorption of a large amount of reactive power collapse.

3. Current differential and grounding protection (87/87GD/67N/50N/51N)

87 phase difference: percentage slope, supports CT ratio correction, main protection stator phase to phase short circuit;

87GD zero sequence differential: internal grounding protection for low resistance grounded units;

67N directional zero sequence overcurrent: distinguish between internal/system grounding to prevent external faults from tripping the generator;

4. Frequency protection (81/81A/81R)

81 Four segment high and low frequency alarm/trip;

Accumulate low frequency duration of 81A and calculate blade resonance damage;

81R frequency change rate, fast load switching.

5. 21 distance+78 step loss

Three segment Mohorz impedance, the third zone is specifically used for system power oscillation lockout, distinguishing permanent phase faults from synchronous oscillations to avoid step loss and false tripping.

6.25 Simultaneous Verification

Before closing, verify the voltage difference, frequency difference, and phase angle simultaneously; Supports multiple parallel logics for both empty and live busbars, and locks non synchronous closing.

7. 64F/B rotor protection

The coupler injects low-frequency signals into the rotor, measures the insulation resistance of the excitation to ground, and detects faults such as grounding of the excitation winding and disconnection of the carbon brush.

8. Auxiliary monitoring function

BM circuit breaker monitoring: integrate I ² t to calculate arc wear, reaching threshold alarm;

TCM trip circuit monitoring: detecting disconnection of trip coils and adhesion of contacts;

60FL PT disconnection: detects the melting of single-phase/two-phase/three-phase fuses, automatically locks voltage related protection (27/59/40, etc.);

IPSigmic custom logic: 6 independent logic units, which can achieve interlocking and automatic switching of fixed value groups through input, fault action, and timing combination.


Whole machine software and communication system

IPScom ®  Upper software: Windows platform, supporting constant value reading and writing, real-time measurement, fault recording download, SOE viewing, and logic programming;

Communication protocol: Standard Modbus RTU/TCP, BECO2200, optional IEC 61850;

Time synchronization: IRIG-B modulation/demodulation signal, millisecond level time scale, unified time reference for faults, recording, and events;

Four fixed value zones: can be manually/HMI/external contacts/communication switched, suitable for unit grid connection/islanding, and different capacity operating conditions; The short-term locking protection of the switching process device is about 1 second.


Installation, wiring, and debugging chapter content

System single line diagram: Provide two mainstream CT wiring schemes: differential and split phase differential, with PT/CT, neutral point CT, synchronous voltage VX, and complete terminal connection of excitation coupler marked;

Terminal definition: Distinguish between voltage input, three-phase/neutral point current, control input, trip/alarm output, communication, and coupler specific terminals;

Grounding specifications: Independent thick copper wire for protective grounding, CT/PT secondary single point grounding, voltage withstand test requires unplugging the plug to avoid damaging the device;

Debugging process

1) System parameter input (CT/PT ratio, wiring method, phase sequence, transformer phase shift compensation);

2) Enable the required protection functions, allocate output contacts, and lock inputs;

3) Set various protection action values, delays, and curves;

4) Wave recording, event, clock configuration;

Standardization testing of the entire machine: Chapter 6 of the manual provides independent verification steps, testing circuits, and qualified accuracy standards for each protection, including self testing, analog calibration, and contact output testing.


Recording and diagnostic functions

Target fault storage: Save the last 32 trips, record the operating components, current and voltage, and time scale;

SOE event log: 512 millisecond level events, recording input displacement, protection start, trip, and communication status;

Fault recording: COMTRADE international standard waveform, can set trigger source (fault, external contact, communication command), pre recording+fault recording;

Device self diagnosis: power on self-test, real-time monitoring of CPU, memory, and peripherals during operation, flashing fault code LED prompt, complete fault code comparison table in the appendix.

  • ADLINK CPCI-6860A - 51-31310-OB10 industrial motherboard CompactPCI SBC
  • ADLINK AmITX-SL-G-H110 - 51-7A104-0A30 Mini-ITX Industrial Motherboard
  • ADLINK PXI-2005-003 - CPCI Industrial PC Data Acquisition Card Multi-Function DAQ
  • ADLINK DININ-814M - 51-14032-0A3D SCSI-100P cable connection Interface Terminal Board
  • ADLINK CPCI-3920NA/C2D15/M1G - 3U CompactPCI Intel Core 2 Duo Single Board Computer
  • ADLINK PCIE-8560 - 51-18014-0A20 Communication Card High Speed DAQ
  • ADLINK PCI-C154+ - Motion Control Card 4-axis Motion Controller Board
  • ADLINK PCI-RTV24 - image capture card Analog Video Frame Grabber
  • ADLINK NuPRO-842LV/P - 51-41360-0B30 Industrial Motherboard CPU Board
  • ADLINK cBP-3208/3208R - CPCI Board 3U 8-Slot CompactPCI Backplane
  • ADLINK PCI-8134 - 51-12403-0B20 PCB Board Motion Controller Card
  • ADLINK LPCI-3488A - PCI Card 51-12801-0A30 Low Profile IEEE-488 GPIB Card
  • ADLINK NUPRO-900A - industrial computer motherboard Single Board Computer
  • ADLINK cPCI-6840V - industrial control motherboard CompactPCI SBC
  • ADLINK M-342 - industrial motherboard ATX Mainboard
  • ADLINK NUPRO-935A/LV - industrial control motherboard
  • ADLINK cPCI-3538 - CompactPCI Async Serial Communications Module
  • ADLINK PCI-1610 - Card 4-Port RS-232 PCI Serial Communication Card
  • ADLINK HSL-DI32-DB-N - Distributed I/O Module 32-CH Digital Input
  • ADLINK CPCI-6860A - motherboard E7501 CompactPCI Single Board Computer
  • ADLINK PCI-8134A - 4-Axis Motion Control Card PCB Board
  • ADLINK EURESYS LINK - grabbers Video Capture Card Frame Grabber
  • ADLINK NuPRO-965DV - motherboard Industrial Control Board
  • Thermo Fisher Scientific 80100-60500 - 80000-61010R 80000-21000R 80000-60457 Spectrum System Controller ADLINK Components
  • ADLINK PCI-7296 - IO card High Density 96-CH Opto-Isolated DIO Card
  • ADLINK MXC-6322D - Matrix Industrial Computer Fanless Embedded PC
  • ADLINK DIN-825-GP4 - connector board Terminal Block Interface
  • ADLINK AMP-208C - Motion Control Card DSP-based 8-axis
  • ADLINK PCIe-GIE72 - 51-18531-0A10 2-CH GigE Vision Frame Grabber PoE+ Card
  • ADLINK PXIS-3320 - PXI/PXIe Chassis 15-slot 6U PXI/CompactPCI SEM-I-1518=9N41
  • ADLINK MI-965 - Industrial CPU Motherboard
  • ADLINK M-302 - Industrial control motherboard
  • ADLINK PCI-6308V - 51-12202-0A50 Isolated Analog Output Card PCB-I-E-1813=ZA03
  • ADLINK NUPRO-935A - Industrial Mother Board CPU Board
  • ADLINK PCI-7434 - PLOTECH Digital Output Card PCB-I-E-1182=6EX2
  • ADLINK PCI-7432 - 64 Channel Isolated Digital I/O PCI CARD
  • ADLINK NUPRO-935A/DV - 51-41802-0A10 motherboard Industrial Control Board
  • ADLINK PCIe-GIE72 - 51-18531-0A10 2-CH GigE Vision Frame Grabber PoE+ Card
  • ADLINK HSL-DI16DO16-M-NN - HSL-DI16DO16-M-NN(G)-0280 Discrete I/O Module Distributed I/O
  • ADLINK cPCI-6760D / cPCI-6840V - cPCI Single Board Computer Industrial Motherboard
  • ADLINK NuPRO-A301 - Motherboard IPC Motherboard
  • ADLINK NuPRO-935A/LV - motherboard Industrial Control Board
  • ADLINK NUPRO-E320LV - motherboard Industrial Control Board
  • ADLINK NuPRO-E42 - Industrial Control Board Motherboard
  • ADLINK M-342 - ATX Motherboard Industrial PC Mainboard
  • ADLINK CPCI-6860 / 6860A - Industrial Control Motherboard CompactPCI SBC
  • ADLINK AmITX-SL-G-Q170/GEHC(EA)-021E - 51-7A104-0A20 Industrial Motherboard w/ DDR4
  • ADLINK NUPRO-852 / NUPRO-852LV - industrial control motherboard
  • ADLINK DAQ-2006-004 - Multi-Function DAQ Cards Data Acquisition
  • ADLINK PCIe-RTV24 - Frame Grabbers Video Capture Cards PCI-e x1 4-CH 120fps
  • ADLINK PCI-8134 - 51-12403-0B20 4-Axis Motion Controller Card
  • ADLINK PCI-8132 - 2-Axis Motion Controller Card
  • ADLINK cBP-6402 - Backplane Passive Backplane
  • ADLINK cPCI-6760D - cPCI Single Board Computer Industrial Control Motherboard
  • ADLINK DIN-825-4PO(G)-0030 - Terminal Board Motion Control Breakout Board
  • ADLINK M-322 - Industrial Motherboard
  • ADLINK ABX-1301 - 51-63808-0A20 Industrial Motherboard
  • ADLINK PCI-7433 - 64-CH Isolated Digital Input Card
  • ADLINK AMP-208C - Motion Control card
  • ADLINK DIN-50S-01 - TECHNOLOGY TERMINAL BLOCK INTERFACE MODULES W/ DIN RAIL
  • ADLINK PCI-8134 - 51-12403-0B20 4-Axis Motion Controller Card
  • ADLINK MXE-201/MSSD64G - Technology Automation Computer Fanless Embedded System
  • ADLINK USB-3488A (G) - USB to GPIB CARD Controller Interface
  • ADLINK cPCI-3720L2 - SBC Single Board Computer PCB AMAT 0190-14599
  • ADLINK PCI-7251 - Relay Output Board Expansion Module
  • ADLINK PCI-8124-C - PCB Board 4-CH Encoder Trigger Card
  • ADLINK HD636 - Industrial Computer Board PCB-I-E-2200=9L32-2 Main Board
  • ADLINK USB-3488A - THERMOTRON INDUSTRIES IEEE 488 CPU INTERFACE WITH USB/GPIB
  • ADLINK MI-965 - motherboard Industrial CPU Board
  • ADLINK LPCIe-7250 - Technology Digital IO card Low Profile PCIe Relay Output
  • ADLINK NuPro-720/SCOPUS - Technology With 256MB Industrial MotherBoard
  • ADLINK NuPR0-840 - industrial control motherboard
  • ADLINK M-342 - Motherboard ATX PC Mainboard
  • ADLINK MI-965 - motherboard Industrial CPU Board
  • ADLINK CPCI-6530V/4402E/M4G - AMAT CPCI-6503VED/4402E/M4-0/SD64G-2550 Universal SBC
  • ADLINK IMB-M43-IRV - Industrial Motherboard ATX PC Board
  • ADLINK 52983 / 58183 - Chroma PXI I/O Input/Output Card + Carrier Adapter
  • ADLINK PXI-3920 - PXI 3U cPCI Industrial Controller w/ RAM SSD Embedded CPU
  • ADLINK NuPRO-842LV/P - motherboard Industrial Control PC Board
  • ADLINK PCI-7442 - 64-Channel Datalogging Acquisition Switch Card
  • ADLINK PCIe-RTV24 - Cadre Agrippeurs Vidéo de Capture Cartes Pci-E x1 4-CH
  • ADLINK ACL-7122A - TECHNOLOGY 51-11004-1A1 CIRCUIT BOARD 96-CH DIO Card
  • ADLINK PCIe-RTV24 - 51-18016-0A20 Image Acquisition Video Capture Card
  • ADLINK AMP-204C - DSP-Based 4-Axis Advanced Pulse-Train Motion Controller
  • ADLINK 52981 / 58183 - Chroma PXI Digital I/O DIO Input/Output Card + Carrier Adapter
  • ADLINK PCI-8102 - motion control card 2-Axis
  • ADLINK NuPRO-E320LV - industrial computer motherboard
  • ADLINK PCI-RTV24 - card Analog Video Capture Frame Grabber
  • ADLINK M-302 - Motherboard P/N: 08GSAQ96501102
  • ADLINK NEON-1020 - Smart camera Industrial Machine Vision
  • ADLINK AMP- 208C - card DSP-based 8-axis Motion Controller
  • ADLINK PCI-9114DG - Multi-Function Daq Card Data Acquisition
  • ADLINK MXC-6322D/BE_FanG) - Matrix PM2-MXC Fanless Embedded Computer
  • ADLINK DIN-825-4P0 - Terminal Board Motion Control Breakout Board
  • ADLINK HPCI-8S4 REV.B2 - Industrial Control Base Plate Passive Backplane
  • ADLINK HSL-DI32-DB-N - Distributed I/O Module 32-CH Digital Input
  • ADLINK NuPRO-935A/DV - industrial control motherboard
  • ADLINK PCI-7442 - Switch card 64-CH Datalogging Acquisition Card
  • ADLINK NuPRO-E42 - motherboard 51-41808-0A30 Industrial Motherboard
  • ADLINK CPCI-3610D/N45/M1G(G)-10B0 - CompactPCI Intel Atom Single Board Computer CPU Board
  • ADLINK LPCI-7250 - GP Output Isolated Digital Input Card PCB 51-12803-0A10
  • ADLINK PCI-7250 - 51-12007-0A40 PCI7250 8-CH Relay Output & 8-CH Isolated DI Card
  • ADLINK STC-1005 - 10.4inch touch panel PC E3845 CPU
  • ADLINK PCI-FIW64 - image card FireWire Frame Grabber
  • ADLINK NuPRO-935A/LV - industrial computer motherboard
  • ADLINK PCI-8164 00B0 - Centralized Motion Controller 4-axis PCB-I-E-1179=6EX2
  • ADLINK ACLD-9137F REV A1 - 51-14006-101 Screw Termination Board
  • ADLINK PCI-7248 - 51-12006-0A40 Control Card Digital I/O
  • ADLINK HPCI-8S4 - Technology Backplane PCB GaSonics 3500 Asher Passive Backplane
  • ADLINK NuPRO-E320LV - Cpu Board 51-41804-0A20 Industrial Motherboard
  • ADLINK HPX-13S4 - device baseboard Passive Backplane
  • ADLINK M-322 - industrial motherboard
  • ADLINK NuPRO-865 REV :3.0 - industrial motherboard
  • ADLINK DIN-68S-01 - Terminal Block Interface Module Cable Connection
  • ADLINK ETX-IM266-C100Z - motherboard ETX CPU Module
  • ADLINK NuPRO-E320LV - motherboard Industrial Control Board
  • ADLINK NuPRO-841 REV:2.0 - motherboard Industrial PC Board
  • ADLINK ETX-AT-N270-18 - N270 Board ASH-EAT-18/S512 ET Mainboard
  • ADLINK PCI-RTV24 - Image capture card Analog Frame Grabber
  • ADLINK PCI-8102 - card 2-Axis Motion Controller
  • ADLINK M-322 - industrial motherboard
  • ADLINK PCI-9114 REV.C2 - acquisition card Multi-Function DAQ
  • ADLINK NuPRO-865 REV :3.0 - industrial motherboard
  • ADLINK DIN-68S-01 - Terminal Block Interface Module Cable Connection
  • ADLINK M-322 - Industrial Motherboard Mainboard
  • ADLINK CPCI-6860A - E7501 dual Xeon CPCI Single Board Computer
  • ADLINK MXC-6301D(G) - Technology Expandable Fanless Embedded Computer i7-3610E
  • ADLINK NuPRO-842LV - 51-41360-0B1 Industrial Motherboard