Beckwith M-3425A Generator Integrated Protection Relay

From: | Author:Wang | Time :2026-06-11 | 10 visit: | 🔊 Click to read aloud ❚❚ | Share:

Beckwith M-3425A Generator Integrated Protection Relay

Product Overview

1. Positioning and core competencies

M-3425A is an integrated generator digital protection system that integrates six functions: protection, measurement, waveform recording, event recording, logic control, and communication. A single device can achieve a complete set of main and backup protection for the generator, supporting single machine and multi machine parallel scenarios, and adapting to generator sets with different grounding and winding structures.

2. Version and Feature Pack Division

The product is divided into basic function package and full function package, and also provides multiple optional extension functions, which can be selected as needed:

Basic package: comes standard with most of the conventional electrical protection, basic logic, and IO functions;

Full function package: includes all the functions of the basic package, and adds advanced protection such as distance protection, step loss protection, and low-frequency accumulation;

Optional functions: synchronous detection (25), rotor grounding/brush detachment protection (64F/64B), low-frequency injection type 100% stator grounding protection (64S), etc. Some optional functions require external hardware.

3. Supporting software, hardware, and options

Supporting modules: M-3925A action indication module, M-3931 human-machine interface (HMI), M-3921 rotor grounding coupler (64F dedicated);

Software tools: S-3400 IPScom (configuration, monitoring, communication), M-3801D IPSlot PLUS (waveform analysis);

Communication accessories: various types of RS-232/RS-485 communication cables, fiber optic components;

Power options: redundant power module (divided into low voltage/high voltage versions);

External hardware (64S dedicated): 20Hz signal generator, bandpass filter, dedicated current transformer.


Complete set of protection functions (numbered according to ANSI standards)

(1) Basic package protection function

24 overexcitation protection (V/Hz): with two characteristics of time limit and inverse time limit, it prevents the generator core from overheating due to low-frequency overexcitation. The parameter range, delay, and reset time can all be set.

27 phase low voltage protection: Three segment fixed value independent configuration, with delay logic, to deal with system voltage loss and fault low voltage.

27TN neutral point third harmonic low voltage protection: relying on the third harmonic to achieve stator grounding auxiliary protection.

32 direction power protection: with three fixed values, it can achieve reverse power, low forward power, and over power protection, used for generator and motor operating conditions, overload protection, and supports sequential tripping logic.

40 demagnetization protection (dual zone offset M-O characteristic): dual impedance area configuration, can stack low voltage acceleration trip logic to prevent generator demagnetization and step loss.

46 Negative sequence overcurrent protection: divided into time limit/inverse time limit, suppresses negative sequence current caused by unbalanced load and phase to phase faults, and prevents rotor overheating.

49 Stator Overload Protection: Based on positive sequence overcurrent, simulate winding thermal accumulation characteristics, set time constant and maximum overload current.

50 phase instantaneous overcurrent, 50N neutral point instantaneous overcurrent: no delay quick break, as the main protection for short circuit.

50DT phase separated differential timed overcurrent: specifically designed for differential protection of split phase windings.

50BF circuit breaker failure protection: After detecting a fault, if the circuit breaker does not open, the failure trip logic will be activated.

50/27 Mis power on protection: Combined with overcurrent and low voltage criteria, it prevents the generator from accidentally closing and being energized during shutdown.

51N neutral point inverse time overcurrent, 51V three-phase inverse time overcurrent with voltage control/lockout: equipped with IEC and IEEE multi class inverse time curves, adapted to different fault characteristics.

59X phase overvoltage, 59N neutral point overvoltage, and 59X multifunctional overvoltage: 59X can be used for inter turn short circuit and bus grounding protection.

59D Third Harmonic Voltage Ratio Protection: Utilizing the third harmonic ratio between the machine terminal and the neutral point to achieve stator grounding protection.

60FL voltage transformer disconnection detection: Identify VT circuit faults, automatically lock relevant voltage protection, and prevent misoperation.

67N residual direction overcurrent: zero sequence direction protection, for grounding faults.

81 frequency protection: four frequency settings, covering high-frequency and low-frequency faults.

87 differential, 87GD ground (zero sequence) differential: Generator main differential protection, distinguishing between phase and ground faults, supporting CT error compensation.

IPSigmic programmable logic: supports AND/OR/non Boolean logic+timer, customizable linkage, lockout, and trip logic.

Circuit Breaker Monitoring (BM) and Trip Circuit Monitoring (TC): Monitor the number of circuit breaker actions and the integrity of the trip circuit.

(2) New protection added to the full-featured package

21. Three stage inter phase distance protection: with M-O impedance characteristics, equipped with load obstacle avoidance barriers and out of step locking, as a backup protection for the line;

78 out of step protection: detect generator and system out of step oscillations, configure impedance circle and sliding pole counting logic;

81A low frequency cumulative protection: divided into 6 frequency intervals, accumulating low frequency operation time to prevent blade resonance damage;

81R Rate of Change in Frequency (ROCOF) Protection: Monitor frequency mutations and respond to islanding and system disturbances.

(3) Optional extended protection

25 Synchronous detection: Verify the voltage, frequency, and phase difference on both sides, support empty line/empty bus logic, and be used for grid locking;

64F rotor grounding protection: To detect grounding faults in the rotor winding, an M-3921 coupler is required, and the injection frequency and grounding resistance can be set to a fixed value;

64B brush detachment protection: monitoring the status of the grounding brush circuit;

64S low-frequency injection type 100% stator grounding protection: external components such as a 20Hz signal source can achieve full range stator grounding protection during unit operation/shutdown.

Hardware, interfaces, and electrical parameters

1. Hardware form and installation

Standard 19 inch rack mounted, supporting horizontal/vertical panel installation, divided into standard IO version and extended IO version, with different sizes and weights;

The circuit board is detachable, and the power supply and main circuit are designed to be partitioned;

Working temperature: -20 ℃~+70 ℃, storage, temperature and humidity, vibration, and impact meet industrial relay protection standards.

2. Sampling and Input/Output

(1) Transformer adaptation

CT: Supports two secondary rated currents of 1A/5A;

VT: Suitable for conventional unit voltage transformers, supporting line voltage, phase voltage, and delta/star connection configurations.

(2) Switching quantity

Standard configuration: 6 programmable inputs, 8 programmable outputs;

Expand IO: Add an additional 8 inputs and 15 outputs;

The output contacts meet the ANSI/IEEE C37.90 standard and are capable of self holding/pulse output.

(3) Power system

Main power supply: supports multiple specifications of AC and DC, wide voltage input, and has surge withstand capability;

Optional redundant power supply to enhance power supply reliability;

The tripping circuit and auxiliary circuit voltage support multi-level adaptation.

3. Communication interface (Class III standard+optional network port)

COM1 (Front Panel RS-232): Local PC direct connection, used for on-site debugging;

COM2 (Backplane RS-232): capable of remote communication or IRIG-B timing; After enabling the network port, the communication function is disabled;

COM3 (Backplane RS-485): Two wire bus, supports multi unit network, can connect up to 32 devices at most;

Optional RJ45 Ethernet port: Supports Modbus TCP/IP, BECO2200, IEC 61850 protocols;

IRIG-B time synchronization interface: supports modulation/demodulation signals, achieving millisecond level accurate event timing.

4. Core accuracy and fixed value range

Analog quantities such as current, voltage, frequency, impedance, and power are all given with setting step size, measurement accuracy, and error range;

All protection delays are measured in cycles (1 cycle)= 20ms@50Hz  /  16.67ms@60Hz )The maximum setting range is up to 8160 cycles;

Built in multiple sets of inverse time curves: BECO, IEC, IEEE standard curves are fully covered.


Human computer interface and local operation

1. Panel components

M-3931 HMI: 2-line x 24 character backlit display screen+operation buttons, menu style operation;

Status indicator lights: device normal, fault, waveform recording trigger, power supply, circuit breaker position, synchronization status, etc;

M-3925A indicator module: 24 protection action LEDs, 8 output status LEDs, visually display which protection has tripped.

2. Permission management

Set third level access password:

Level 1: Only view parameters, status, and events;

Level 2: Can modify settings and view historical records;

Level 3: Complete configuration, system settings, password modification (highest authority);

Default password disabled, user customizable.

3. Local core functions

Real time monitoring: full electrical parameters such as voltage, current, power, frequency, impedance, harmonics, and third harmonic;

Fixed value viewing/modification, protection of investment and withdrawal;

Query and clear event and trip records;

Manual triggering and viewing of waveform recording;

System time, communication parameters, and device number settings;

Self diagnosis and fault code reading.


Data recording and waveform recording function

1. Event Record (SOE)

Resolution of 1ms, with precise time scale;

Record protection actions, IO displacement, device alarms, communication failures, etc;

Data is not permanently saved in the event of a power outage, resulting in loss. It supports export and printing.

2. Trip target record

Store the last 32 tripping events, record the action protection, current electrical quantity, input/output status, and time scale.

3. Fault recording (oscilloscope function)

Sampling frequency: 16 times the system frequency;

The memory can be divided into 1-16 partitions, with a maximum record length of 416 cycles;

Support pre/post waveform recording, triggering methods: protection action, switch value, communication manual triggering;

File format: COMTRADE, BECO universal format, can be parsed, plotted, and analyzed using IPSplot software;

Wave recording data lost due to power outage.

4. Cumulative quantity monitoring

Accumulated circuit breaker actions and fault current integration;

Accumulated frequency operation (81A dedicated), calculate the total duration of low-frequency operation of the unit.


S-3400 IPScom software operation

This software is a PC core configuration tool that supports multiple connection methods such as serial port, Ethernet, and modem. Its core functions are as follows:

Communication management: Establish connections, set baud rates, addresses, protocols, DHCP/static IP addresses;

Parameter configuration: all protection settings, IO allocation, logic programming, curve setting;

Real time monitoring: primary/secondary electrical quantities, phasor diagram, impedance diagram, out of step/synchronous visualization interface;

File management: parameter upload/download, saving configuration files;

Data analysis: Read SOE, trip records, and waveform files;

Equipment maintenance: firmware upgrade, calibration, counter reset, output circuit testing.

The software menu includes seven modules: File, Communication, Monitoring, Relay Settings, Tools, Windows, and comes with a complete interface operation guide and pop-up instructions.


System Configuration and Logic (IPSigmic+Fixed Value Group)

1. Four sets of fixed value groups

The device is equipped with four independent constant value schemes, which can be manually/automatically switched through panel, communication, and switch values to adapt to different operating conditions of the unit (no-load, grid connected, maintenance, special methods).

2. Programmable Logic (IPSpeegic)

By utilizing device input and protection action signals, and customizing interlocking, locking, interlocking tripping, and alarm circuits with/or without logic and timers, flexible adaptation to special logic requirements on site can be achieved.

3. IO configuration

Each input function (protection interlock, remote control, circuit breaker position, etc.) and output purpose (trip, alarm, signal) can be freely defined, supporting pulse/hold output and action delay settings.


Testing, Diagnosis, and Maintenance

1. Factory/on-site testing items

The complete process includes hardware self check, input/output circuit testing, LED/button testing, communication circuit testing, analog calibration, and protection transmission testing.

2. Self diagnostic function

The device performs power on self-test and monitors hardware, power supply, communication, and VT/CT circuits in real-time during operation. Faults are presented in code form, and a complete fault code table is attached to the manual.

3. Daily maintenance

Regularly check the wiring, grounding, and terminal fastening;

Regularly export event and waveform data for archiving;

Upgrade firmware and calibrate sampling circuit as needed;

Follow the general scrap and anti-static regulations for electrical equipment.


Compliance, Standards, and Certification

Safety regulations and electromagnetic compatibility: comply with IEC 60255, ANSI/IEEE C37 series standards, and pass surge, static, fast transient, and radiation immunity tests;

Mechanical environment: meet the requirements of vibration, impact, high and low temperature, humidity, and salt spray tests;

Certification: UL, CSA, CE and other international certifications;

Document Appendix: Includes inverse time curve chart, wiring diagram, terminal definition, communication pins, installation dimensions, and drawing index.

  • Woodward 8272-796 - Real Power Sensor Module 115/230v-ac
  • Woodward 5463-873 - NetCon Output Module
  • Woodward 8271-567 - Load Sensor Module 120/208v-ac
  • Woodward Type UG-8 P/N 8522-300 EG - Governor R.P.M 1075-1650 With Motor Groschopp
  • WOODWARD 9905-971 REV J - LINKNET 16 CHANNEL DISCRETE INPUT MODULE
  • WOODWARD 8280-3014 - 723 PLUS DIGITAL CONTROL REV NEW
  • Woodward 505DE - Digital Control System
  • Woodward 5453-750 - Ethernet Interface FTM
  • Woodward 9907-018 Rev H - 2301A Load Sharing & Speed Control
  • WOODWARD 5420-1080 V4.3 - BOARD-PPA WITHBOX
  • Woodward b 8271-347SP - 2301 speed control
  • Woodward 9905-795 Rev B - Digital Synchronizer and Load Control
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8272-582 - Generator speed control module
  • WOODWARD 9907-247 REV K - 828 DIGITAL CONTROL UNIT
  • WOODWARD 5466-353 REV C - NETCON MAIN CHASSIS TRANSCEIVER
  • Woodward Type UG-8 P/N 8524-708 - Governor 760-1560 Governor R.P.M
  • WOODWARD 9907-247 REV K - 828 DIGITAL CONTROL UNIT
  • WOODWARD 8440-1831 REV. H - EASYGEN3000 3200-5 - WITHOUT ACCESSORIES
  • WOODWARD 8444-1002 REV G - UMT1 MEASURING TRANSDUCERS
  • Woodward 5410-312C - Digital Marine Control Printed Circuit Board
  • Woodward 9905-799 REV F - Digital Synchronizer & Load Control , V#456
  • Woodward 9907-014 - 2301A for controller
  • Woodward Type UG-8 P/N B522-446 - Governor R.P.M 500-1200
  • WOODWARD 8272-221 REV.B - DIGITAL REFERENCE UNIT
  • Woodward 8901-037 - Booster Servomotor Single
  • WOODWARD 8444-1019 REV G - UMT 1 MEASURING TRANSDUCER
  • WOODWARD 1767-367 Z21 WK 0920702 - GOVERNOR MOTOR 2700 RPM KM 58-20 K 230V
  • WOODWARD 9905-972 Rev:G - LINKNET 6 CHANNEL 4-20mA OutPut
  • Woodward E8250-501 - Actuator Governor
  • WOODWARD 5466-258 REV M - SIMPLEX DISCRETE I/O MODULE
  • WOODWARD 5501-470 REV E - NETCON CPU MODULE
  • Woodward 8406-120 rev H - egcp-2 digital control
  • Woodward 8440-1799 - Easygen-350 Rev B
  • Woodward 8440-1878 - DSLC-2 Digital Synchronizer Load Control
  • Woodward 5464-843 - Cpu Processor Module
  • WOODWARD 8440-1409 Rev. J - MFR2 MDE Synchronization & Protection MSP
  • Woodward 9907-014 - controller
  • WOODWARD 9907-173 - LOAD SHARING MODULE 120V
  • WOODWARD 8440-1831 REV. K - EASYGEN 3200-5 - WITHOUT ACCESSORIES
  • Woodward 9905-969 - LinkNet Module LinkNet 6C 4-20ma in w/24v
  • Woodward 8520-498 - Governor Type UG-8 Governor R.P.M 850-1650
  • WOODWARD 5466-257 REV.-C - NETCON 5000 MODEL REMOTE TRANSCEIVER I/O MODULE
  • WOODWARD 8800 - 1001 REV-C - DSS-2, 2 CHANNEL DIGITAL SPEED SWITCH
  • WOODWARD 5501-467 REV. C - MICRONET SIMPLEX POWER SUPPLY
  • Woodward 8273-584 - Atlas-ii Digital Control
  • Woodward 8440-1019 b - spm-d10 synchronizing system
  • Woodward CSC3SUWA REV K - CSC3SUWA Controller
  • Woodward 5441-693 Rev B - Digital I/O Module
  • WOODWARD DPG-2201-002 REV.D - Governor Onan DIGITAL SPEED CONTROLLER
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8440-1884K - GENERATOR CONTROLLER EASYGEN-2500-5 REV,K
  • WOODWARD 8404-1006 - Industrial Component
  • WOODWARD 5437-1118 - PROTECHTPS MODULE Relay Bulkhead Panel
  • Woodward 8440 1801 Rev C - Easygen-350-50B/X Genset Control Engine Generator 24VDC
  • WOODWARD 5466-348 - MODULE
  • Woodward 9905-799 REV F - Digital Synchronizer & Load Control , V#456
  • Woodward 9907-018 - 2301A Load Sharing & Speed Control Rev H
  • Woodward GM9412H918-R2 1766-039 REV E - Cruise Control Motor
  • 5466-258 WoodWard - 48 Input 24 Output Discrete I/O, (UPP)
  • WOODWARD 5484-877 - PM MOTOR 24VDC 15RPM
  • Woodward 8272-221 B - Digital Reference Unit
  • Woodward 9905-796 - Digital Synchronizer And Load Control (Rev. H)
  • WOODWARD 5441-645 REV.G - 10AMP RELAY INTERFACE 11459968
  • Woodward 9907-207 - 721 Digital Control 88-132VAC
  • WOODWARD 8272-582 - APM MOTOR CONTROL AC/DC 100~220V
  • Woodward 5464-843 - Cpu Processor Module
  • Woodward 9905-001 L - SPM-A Synchronizer 115/230V 50/60Hz 10W
  • Seg Power Protection PCK4 P/N 8445 1006 A / PCKR-MW - Protection Relay 24VDC
  • Woodward 8405-062 - Actuator
  • Woodward 5464-738 - Industrial Control System
  • Woodward CSC3HUWB - controller
  • Woodward 8272-517 - PM Motor Control 220vac
  • Woodward 8272-582 - APM Motor Control
  • Woodward LR20025 MFR1375M MFR 1 - Controlling
  • Woodward 9905-392 - Proact Driver Model III
  • WOODWARD 8250-774 - ACTUATOR/GOVERNOR
  • Woodward 505DE - Digital Control System
  • Woodward 8280-303 D - 721 Digital Control Rev.G 2.0 AMP 28 VDC
  • WOODWARD DPG-2201-002 REV NEW - DIGITAL CONTROLLER
  • WOODWARD 8272-286 - 2301A LOAD SHARING & SPEED CONTROL MODULE
  • WOODWARD 8440-1884 REV M - GENSET CONTROLLER EASYGEN-2500-5/P1
  • Woodward 9905-797 Rev. M - Digital Sync And Charge Control
  • W0ODWARD ART-01681 - IDS Communicator Control Box
  • Woodward 8273-584 - Digital Control Unit ATLAS-II REV: A 18-32VDC, 60W
  • WOODWARD 5501-470 REV E - NETCON CPU MODULE
  • Woodward 1752 1752-227 - Revision D FireFly Current Load input Engine Control
  • Woodward 8440-1877 - MSLC-2-5 Control
  • Woodward 8271468 - Generator Loading Control (Rev. D)
  • Woodward 9905-387 - Pro Act Driver Model lll (Rev. F)
  • Woodward 9905-363 - Sincronizzatore Digitale E Controllo Carico
  • WOODWARD 8272-583 - APM MOTOR CONTROL
  • WOODWARD EGCP-2 - Digital Generator Control Panel 4-20MA 5V 500HZ
  • Woodward 9905-392 - Proact Driver Model III
  • Woodward 9905-392 - Proact Driver Model III
  • Woodward 8270-007 - Load Signal Control
  • Woodward 8271-651 - Digital Speed Reference
  • WOODWARD 8440-2219 - EASYGEN-2500-5-P1-K49 GENSET CONTROLLER
  • Woodward D8271-394 - 2301 Load Sharing And Speed Control Module 20-40v-dc
  • Woodward 8200-1504 Rev:E - Peak200 Steam Turbine Control Front Panel Mount HVAC
  • WOODWARD 8444-1022 REV F - UMT 1 MEASURING TRANSDUCER
  • WOODWARD 8440-1923 A - EASYGEN-3200-5 CONTROLLER
  • WOODWARD 9907-014 - 2301A controller
  • Woodward 8272-583 - Amp Motor Control DC24V
  • Woodward 9907-147 REV N - ProTech 203 Overspeed Protection System
  • Woodward 8270-417 - 2301 speed sensor
  • Woodward 8272-583 - Amp Motor Control DC24V
  • Woodward 8934-658 - Repair Kit UG8D Governor
  • Woodward 5437-281 - analog module
  • Woodward 8440-2177 A - SPM-D2-10 Digital Synchronising Controller
  • SA-4478 EPS1000 - Speed Switch
  • Woodward 9907-014 Rev: J - 2301A Speed Control
  • Woodward 9907-026 Rev C - Load Sharing Module
  • Woodward B8271-464 H B8271464 - 2301 Speed Control
  • WOODWARD 8440-1667 REV C - SPM-D10 SYNCRONIZING UNIT
  • Woodward 8440-2082 - EASYGEN-3200XT-P1 Engine Generator Control
  • Woodward 8406-120 rev H - egcp-2 digital control
  • WOODWARD SPM-D - SYNCHRONIZING SYSTEM
  • Woodward 8271-651 - Digital Speed Reference
  • WOODWARD 8444-1074 A - MODULE
  • WOODWARD 8440-2050 Rev B - EASYGEN-3200-5 CONTROLLER
  • Woodward 8440-1613 REV E - GCP30 Genset Control Package
  • Woodward 9907-018 - Load Sharing & Speed Controller Rev H 90-240VAC
  • Woodward 5466-315 - module
  • Woodward 9905-204 Rev N - SPM-A synchronizer
  • Woodward XG2 - Protection relay
  • WOODWARD 9907-175 LOAD SHARING MODULE REV A - Load Sharing Module
  • Woodward 9907-166 REV: N - 505E Turbine Control 110V AC/DC