K-WANG



Product positioning
DIAX04 is a modular multi axis AC servo drive system, which is divided into HDS modular plug-in card drives and HDD fixed configuration dual axis drives; Equipped with HE/HVR power supply unit, suitable for AC servo/spindle motors such as MKD and MHD; Applied to machine tools, printing, packaging, robots, and handling equipment.
Supporting options
HZB braking resistor: consumes braking energy without regenerative power grid
HZK capacitor module: frequent start stop conditions
HZF power connection module
System hardware architecture
2.1 HDS Drive (Modular, with optional card insertion)
HDS consists of 5 parts: basic unit body+command communication module+HSM software module+additional card insertion module+configuration nameplate
Command communication module: SERCOS (DSS02.1M), analog interface (DAE02.1M), serving as the interface between the driver and the upper controller.
HSM software module: stores firmware and all driver parameters; When replacing the drive, simply plug and unplug the HSM to migrate parameters and quickly restore device operation.
Various types of additional cards (U1-U4 slots)
Digital IO card DEA series: PLC bidirectional data exchange, 15 in 16 out/32 in 24 out multiple specifications
Measurement system interface card: supports square wave incremental encoder, 1Vpp sine encoder, SSI multi turn absolute value, rotary transformer, and Rexroth gear encoder; Some interface cards cannot be mixed at the same time.
Bus coupling card: ARCNET, multi master CLC-D control card, SSI absolute value simulation card.
Configure nameplate: Record the module model of each slot, and confirm the hardware configuration based on the nameplate when repairing or replacing spare parts.
2.2 HDD02.2-W040N-HD32 (fixed configuration dual axis drive)
Fixed hardware, a single unit can drive 2 motors, and card insertion cannot be freely replaced.
Built in SERCOS fiber optic interface, each axis comes with a 1Vpp sine encoder second feedback port.
The number of slots is less than HDS, and there are no U3/U4 expansion slots.
2.3 Model coding rules
HDS Code: Product Line Series Version Cooling Method Rated Current Special Version Controller Family Communication Type Function ID Function Version Firmware Identification FW
HDD encoding: Similar in structure, the communication bits represent the built-in SERCOS interface.
2.4 Overview of Key Technical Parameters
Project Description
Power specification HDD02.2-W040:40A; HDS02.2‑W040:40A; HDS03.2‑W075/100; HDS04.2‑W200; HDS05.2‑W300A
Switching frequency 4kHz/8kHz, the higher the switching frequency, the lower the allowed continuous current and the greater the loss
Rated operating condition of ambient temperature+5~+45 ℃; Maximum derating+55 ℃; Storage -30~+85 ℃
Installation altitude ≤ 1000m full power; 1000m requires derating, provide altitude and temperature derating coefficient curves; Multiply two derating coefficients when temperature and altitude exceed the standard
Protection level IP10, must be installed inside the control cabinet
Weight 6.5-25kg, increases with increasing power
The greater the power loss, the higher the loss; The manual provides loss continuous current curves for different models at 4/8kHz; Simultaneously provide the power consumption value of each card for cabinet heat dissipation calculation
Attention: If the output capacity exceeds the temperature and altitude range, it must be converted according to the derating factor, otherwise the equipment will be damaged and the warranty will be lost.

Safety regulations
It must be operated by trained and qualified electrical personnel.
High voltage hazard: After power failure, the capacitor needs to wait for 5 minutes to discharge. Before operation, measure and confirm that there is no residual high voltage; The cross-sectional area of the copper conductor for protecting the ground wire is ≥ 10mm ²; Prohibit the use of residual current devices (RCD) to protect this drive; The casing must be permanently grounded.
Prevent misoperation: The monitoring of the driver itself cannot serve as a personal safety guarantee; External safety fences, safety gates, and emergency stops must be added; The vertical axis cannot rely solely on the motor brake, it requires a mechanical locking/external clamping mechanism to prevent falling.
Magnetic field risk: Personnel wearing pacemakers or metal implants are prohibited from approaching running motors/drives.
High temperature components: radiator, shell high temperature, stop and wait for 10 minutes for cooling before touching.
Battery safety: Onboard batteries are classified as hazardous waste and are prohibited from disassembly, incineration, or charging.
Prohibited use scenarios: Passenger elevators, cranes, medical equipment, nuclear/radioactive equipment, mining equipment, etc. are not allowed to be used.
Usage standards
Compliant use: can only be used for industrial multi axis servo control such as industrial machine tools, handling, packaging, printing, etc; The manual must specify the motor, cable, and accessories; Hardware modification is prohibited, and software decompilation is prohibited.
Non compliant use: underwater use, exceeding environmental conditions, non Rexroth unreleased application scenarios; The manufacturer is not responsible for damages caused by misuse, and the warranty is invalid.
Electrical connection planning
Static protection requirements: The human body, tools, and soldering iron must be grounded, as static electricity can damage the circuit board; Strong current cables and signal lines must be routed separately, and analog signals must be shielded; Before conducting the overall voltage withstand insulation test, it is necessary to disconnect all wiring of the driver to avoid damaging electronic components.
Main connector definition
Connector function
X1 adjacent unit integrated bus, flat cable, power supply for electronic board, power unit to drive internal interconnection, maximum 1m
X2 serial interface, supporting RS232 (single unit, 15m)/RS485 (up to 31 stations, 500m), used for PC debugging (DriveTop/SERCTOP software)
X3 analog diagnostic output (± 10V), ready Bb relay contact, start interlock safety circuit AS; start interlock only prohibits start and cannot stop the motion axis
X4 motor encoder feedback 1 (HSF/RSF Rexroth encoder, rotary converter)
X5 DC bus, motor three-phase power terminal; Provide terminal torque and cable cross-sectional area requirements for each power level; Double grounding of equipment (backboard guide rail+front grounding buckle)
X6 motor brake, motor temperature sensor PTC/NTC; The brake requires an external 24V power supply, and the driver only controls internally; The motor brake cannot be used as a personnel safety brake
X7.1/X7.2 (HDD only) second 1Vpp sine position feedback interface, external measurement such as grating, cable length up to 50m
X10/X11 (HDD only) SERCOS fiber optic interface; Can set transmission power and baud rate (2M/4Mbaud), in compliance with IEC/EN61491
X12.1/X12.2 (HDD only) External digital inputs: reference switch, limit, measuring probe, emergency stop input
Motor cable: Rexroth prefabricated cable with a maximum length of 75m; the cable includes three-phase power PE、 Temperature shielding wire, brake shielding wire.
Design and planning of control cabinet body
Installation guide rail: Special guide rail SUP-M01-HD, vertical installation of the driver; Specify the minimum installation gap around the interior of the cabinet to ensure heat dissipation.
Loss and heat dissipation calculation
System total heat generation=power unit loss+total driver loss+all card insertion power consumption.
Driver losses are divided into fixed losses in the control part, power losses, and current related losses; The manual includes loss curves for 4kHz and 8kHz of each power driver; Provide a complete example of a 4-axis system.
Cooling must be configured when the temperature inside the cabinet exceeds 45 ℃; The installation of the cooling system should prevent condensation water from falling onto electronic components, and there should be a correct/incorrect installation diagram.
EMC wiring requirements: power cables and signal cables should be arranged separately; Simulate and feedback cables using shielded cables; Perform proper shielding and grounding treatment.