Overall system architecture
Three system versions
System version core controller positioning
MTX compact IndraControl L40 compact, rail mounted, up to 8 axes
MTX standard IndraControl P40 (PCI card) standard type, up to 8 axes
MTX Performance IndraControl P60 (PCI board) high performance, up to 64 axes, 12 NC channels
P40/P60 are PCI cards that are inserted into Rexroth standard/high-end industrial PCs;
L40 is a DIN rail mounted terminal module that does not require a PC host.
Unified bus: SERCOS fiber optic (driver), PROFIBUS-DP (IO, operation panel), Ethernet (upper communication).
IO system: RECOM Inline (rail IO inside the control cabinet), RECOM Fieldline (distributed IO near the equipment with IP65/IP67 rating).
Human machine components: VSP/VSB/VPP/VPB industrial PC host, VDP display unit, VAM machine tool operation panel, VCP small operation unit, VAK keyboard.
Two major product series of industrial PC
Standard Type (VSP/VSB)
Anti vibration 0.25g, impact 5g; component supply cycle ≥ 2 years;
VSP: Display+PC integrated all-in-one machine;
VSB: PC box inside the cabinet, external VDP passive display panel, connected through GIGASTAR cable.
High end model (VPP/VPB)
Resistance to vibration 1g, impact 15g; long-term supply of components ≥ 5 years; Suitable for harsh working conditions;
VPP: Display PC all-in-one machine;
VPB: PC box inside the cabinet, external VDP passive display screen.
VDP is a passive display unit that has no computing power and must be paired with a VSB/VPB host.
Hardware parameters of core CNC control module
1) IndraControl P40/P60 (PCI card, plugged into IPC slot)
P40: Maximum 8 axes, 2 NC channels, maximum 4 interpolation axes per channel, SERCOS minimum cycle of 6ms;
P60: Maximum 64 axes, 12 NC channels, maximum 8 interpolation axes per channel, SERCOS minimum cycle of 250 μ s;
Processor Celeron 650MHz, onboard SDRAM+SRAM, power consumption of approximately 21W;
Environment: Operating temperature+5~+55 ℃, storage -20~+70 ℃, non condensing;
Interface:
SERCOS (X7S1/X7S2) fiber optic ring network connected servo drive;
PROFIBUS-DP master station (X7P);
Ethernet RJ45; Ready relay contact (connected to emergency stop circuit, 60V/1A);
Optional high-speed IO motherboard: 8-in/8-out high-speed digital IO.
Status indicator lights: Ready Active, Power Good, OK/Error, SERCOS LERR; Equipped with Watchdog reset button;
Repair: Replace the module as a whole, only the CPU fan can be replaced on site, and internal repair of the board is prohibited.
2) IndraControl L40 (DIN rail compact controller, MTX compact)
Model CML40.2-SP-330-NA-NNNNN-NW; AMD LX800 500MHz;
Performance: Maximum 8 axes, 2 main axes, 4 interpolation axes, SERCOS minimum cycle of 6ms;
Power supply: Three channels of 24V DC (logic U_LS, segment U_S, main U_S); Onboard 8-way isolation DI+8-way isolation DO;
Interface: SERCOS fiber optic, PROFIBUS-DP master station, Ethernet, RS232, CompactFlash card (system firmware, program storage, card removal prohibited during operation), Inline IO bus;
Expansion: The FM Bus functional module bus must be paired with CFL01.1-Y1 (an 8MB battery buffered SRAM module with a battery life of 5 years); Optional cooling fan CAL01.1-F1;
Environmental conditions:+5~+55 ℃; The fan must be turned on when the temperature exceeds 45 ℃; Automatically enter standby safety mode at 75 ℃ internally, and set the output to safety;
Local operation: 8-character LCD display screen+4 buttons, reset button, status LED.

Complete set of human-machine HMI components
VSP all-in-one machine (standard): 12 "VSP16/15" VSP40, with integrated display and PC.
VSB40: Standard PC box inside the cabinet, external VDP16 (12 ")/VDP40 (15" including touch version), GIGASTAR dedicated cable.
VPP all-in-one machine (high-end): VPP16 (12 "), VPP40 (15").
VPB40: High end PC box inside the cabinet, externally connected to VDP16/VDP40.
VAM machine tool operation panel: PROFIBUS-DP bus; Equipped with emergency stop, mode knob, feed/spindle ratio knob, and machine buttons; VAM10/40 is used for ordinary CNC; VAM11/41 is used for automated production lines.
VAK keyboard: Pull out, embedded industrial keyboard with pointing stick.
VCP Mini Operation Panel: VCP02/05/08/20/25; Text/graphics/touch, PROFIBUS‑DP, Suitable for easy operation.
IO system
RECOM Inline: Control cabinet DIN rail installation, PROFIBUS‑DP; Coupling module, digital IO, analog, counting module; L40 has a maximum of 63 Inline modules.
RECOM Fieldline: on-site distributed IO, protection IP65/IP67; M12 connector, directly installed near the machine tool body; DI, DO, DIO hybrid module.
Power supply and optional accessories
UPS uninterruptible power supply VAU01.1S-230-255-NN: prevents instantaneous power failure, achieves safe system shutdown, and communicates through COM serial port and IPC; Supporting rail installation bracket.
External Battery Pack SUP-E01-BTV16/40: Used for high-end IPC to cope with power outage protection.
Safety points
For hardware basic security only, machine manufacturers must conduct a complete machine risk assessment.
Operators must undergo professional training; The equipment can only be installed as a whole inside the control cabinet.
High voltage hazard: After power failure, wait for 30 minutes for the capacitor to discharge, measure and confirm that there is no voltage before maintenance; Protect the ground wire with a minimum of 10mm ² copper conductor; It is not allowed to use RCD leakage protectors as drive protection.
Dangerous sports: The built-in monitoring of the drive is not sufficient to ensure personal safety; External emergency stop circuits, safety fences, and light barriers are required; Vertical axis cannot rely solely on motor brake, mechanical locking must be added; It is recommended to string the Ready relay contacts into the emergency stop chain of the entire machine.
Magnetic field risk: Personnel with pacemakers and metal implants are prohibited from approaching the operating drive/motor.
High temperature: The radiator and motor casing can reach over 60 ℃, and sufficient cooling is required before touching during shutdown.
Battery: non rechargeable, prohibited from disassembly and incineration, treated as hazardous waste.
Unauthorized modification of hardware and decompilation of software source code is prohibited; Damaged components are not allowed to be installed on the machine.
Grounding and EMC must meet EN50081-2 and EN50082-2; Cables must be shielded, and high-power power cables and signal cables should be wired separately.
System Connection Example
The manual provides 8 complete topology diagrams: VSP16/VSP40; VSB40+VDP16/VDP40; VPP16/VPP40; VPB40+VDP16/VDP40。 Typical link: IPC host → PROFIBUS-DP → VAM operation panel, VCP operation unit Inline IO、Fieldline IO; CNC board (L40/P40/P60) → SERCOS fiber ring network → servo drive; IPC Ethernet → upper PC, maintenance computer; UPS connected to IPC serial port to achieve power-off shutdown.
System backup
Rexroth Industrial PC comes pre installed with Acronis True Image for full machine disk image backup (. tib image files).
Purpose: Full disk image backup of the system, including operating system, drivers, and MTX software; Used for overall recovery after hard disk failure or misoperation; Do not perform selective backup of individual files.
Acronis Secure Zone: A protected hidden partition on a hard drive (recommended 10GB) that stores images; Startup Recovery Manager can be called by pressing F11, and the system can be restored without the need for a USB flash drive when the hard drive fails to start.
Support: Full backup, incremental backup, image verification, creating bootable rescue USB/CD, scheduled backup tasks.
Key suggestion: It is recommended to use F11 recovery manager or rescue media for system partition recovery, and not to restore the system disk while Windows is running; After completing the image backup, it is necessary to perform image verification.

K-JIANG
Add: Jimei North Road, Jimei District, Xiamen, Fujian, China
Tell:+86-15305925923