K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

Emerson DeltaV Controller

From: | Author:Wang | Time :2025-08-23 | 521 visit: | 🔊 Click to read aloud ❚❚ | Share:



Emerson DeltaV Controller

Core positioning and core advantages

The DeltaV controller redundancy function is applicable to M-series, S-series (including SZ type), and PK type controllers, aiming to avoid critical process interruptions and high downtime losses caused by controller hardware failures through the "primary backup controller" mode. The core advantages can be summarized as four key features:

Uninterrupted control operation: When the main controller fails, the backup controller automatically takes over without initialization or manual intervention. The on-site output signal is undisturbed and the process continues to run; No special wiring or additional configuration is required, redundancy can be achieved by simply adding controllers to the existing hardware foundation.

Online upgrade capability: Supports online upgrade of controller firmware and hardware. New firmware can be installed on the backup controller first (without affecting the current operation), and the backup controller will automatically configure and support switching after the upgrade is completed. After switching, the original main controller will be upgraded; At the hardware level, it supports online upgrades from MQ to MX and SQ to SX, meeting the requirements for expanding control strategies.


Automatic debugging and deployment: The system automatically detects, debugs, and downloads backup controller programs, making on-site equipment replacement safe and convenient; When adding redundancy, only a 2-slot backplane with system power supply needs to be installed for the M/Q/MX/SQ/SX controller. The SZ controller can directly use its 2 slots on the carrier, and the PK controller does not require an additional carrier (comes with 2 slots); No need to set up dip switches, jumpers or addresses, the backup controller automatically assigns addresses, the engineering database is automatically updated, and activation only requires assigning and downloading redundant licenses, without affecting the operation process.

Uninterrupted switching transition: When switching between primary and backup, the output channel remains in its current state until the switching is completed and the control module is started; The control module confirms that all I/O channels are normal through signal status before executing control actions, and uses the I/O read back function to synchronize output signals, ensuring that control calculations are based on real-time output status; This feature is suitable for scenarios where CHARM or DeltaV classic I/O cards are used, regardless of whether Foundation fieldbus devices are connected or not.

Product Core Function Details

(1) Working mechanism

The backup controller stores the same control strategy as the main controller, and redundant links transmit control parameters in real-time to ensure that the backup controller can take over at any time.

After enabling redundancy, each control module will calculate the required update data for the backup controller during execution and transmit it through the redundant link; Redundant functions typically reduce CPU idle time by about 10%.

After the fault triggers a switch, the DeltaV event recorder will store the switch record and the identified cause of the fault; Replacing the backup controller only requires disassembling and assembling the hardware, and the main controller will automatically detect the new backup device and complete debugging and program download.

(2) Switch detection logic

The main and backup controllers continuously self check and monitor each other, and the main controller runs a real-time self check program to determine the functional status.

Scenarios that trigger switching: hardware failure of the main controller, communication failure between the main controller and I/O, communication failure between the dual control network ports of the main controller, removal of the main controller from the carrier, and user switching requests initiated through a diagnostic browser.

If the main controller fails and does not initiate a switch, the backup controller will identify the abnormality by monitoring the I/O bus flow. Before switching, a verification cycle must be passed, during which all output signals remain unchanged until the new main controller starts the control strategy.

(3) System compatibility

Version requirements: The M/S/SZ series supports DeltaV v12.3 and above, while the PK series supports v14.3 and above; In the segmented models, SQ/SX requires v11.3.1+, SZ requires v12.3+, MX requires v10.3+, MQ requires v11.3.1+, and PK requires v14.3+.

Hardware pairing rule: Redundant controller pairs must be from the same series (e.g. M series and S series cannot be paired); Although SX can serve as a backup for SQ and MX can serve as a backup for MQ, it is recommended that the primary and backup hardware be consistent (low configuration primary controllers may not be able to support programs for high configuration controllers), and only temporary mixing during the upgrade period is recommended.

Supporting redundant controller models: MQ, MX, SQ, SX, PK (details can be found in the product manuals of each model), SZ (details can be found in the "DeltaV SIS Electronic Grouping" or "DeltaV SIS IS Electronic Grouping" manuals).


Ordering and preconditions

(1) Order Information

Product Description Model

DeltaV Controller Redundancy License VE31RED

(2) Pre requirements

Except for SZ and PK controllers, each controller in the redundant pair needs to have an independent control network communication interface.

Except for SZ and PK controllers, each controller in the redundant pair needs to be equipped with an independent system power supply on the same 2-slot carrier.


  • LTI Drives CDF30.002.C0.7 Compact Servo Controller 08685963 DC 24V Industrial Module
  • LUST LTI Drives CDB32.008.W2.4.BR.PC1 Servo Drive Industrial Motion System
  • LUST LTI Drives CDB34.003.C2.4.PC1.H15 Servo Motor Driver Industrial Control Unit
  • LUST LTI Drives CDA32.004.C1.4.H08.B0 Servo Drive Mat. 3084456 Industrial Control
  • LUST LTI Drives CDE34.005.W2.2 Industrial Servo Drive Motion Control Unit
  • LUST LTI Drives CDA34.006.W3.0 Servo Drive Software V3.70-04 Industrial Controller
  • LTI Drives CDB32.004.C2.4.SH Servo Drive Compact Motion Controller
  • Woodward 9905-373 - Digital Synchronizer And Load Controller
  • WOODWARD MAGNETIC PICKUPS - Sensor
  • WOODWARD GCP-30 - Steuertafel for Industrial Regulator Genset Control Package
  • WOODWARD GOVERNOR 9907-1183 REV A - 505 ENHANCED TURBINE CONTROL
  • WOODWARD 9907-173 REV B - Module Load Sharing 120 Volt
  • WOODWARD 9907-014 - 2301A controller
  • Woodward 9905-029 - SPM-A Synchronizer Module Rev C
  • WOODWARD 8440-1799 EASYGEN-350 REV B - Genset Controller
  • WOODWARD 5466-258 REV M - SIMPLEX DISCRETE I/O MODULE
  • Woodward 8440-1884 C - Controller Easygen 2500-5
  • Woodward 8441-1153 - Monitoring Unit 250VAC
  • WOODWARD 8406-120 REV G - EGCP-2 DIGITAL CONTROL
  • Woodward 8273-584 - Atlas-ii Digital Control
  • Woodward 8272-582 - APM Motor Control 8272582
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8272-517 - Pm Motor Control
  • WOODWARD 9905-797 REV.B - DIGITAL SYNCHRONIZER AND LOAD CONTROL DSLC-D
  • WOODWARD 8272-582 - APM MOTOR CONTROL
  • Woodward Seg FP2-8-24 - Emergency Power Telecommunications Module NP2
  • WOODWARD 2001-12E2U1B1S1A - Fuel Shut Off Valve Stop Solenoid Valve 2000-4505
  • Woodward 8440-1884 K - Genset Controller Easygen-2500-5
  • Woodward 9905-760 - Linknet Termination Module
  • Woodward 8404-009 - Proact Digital Plus Front Panel Rev. H
  • Woodward 8271-651 - Digital Speed Reference
  • Woodward 3077-474C - 8605895 5501-031 D Circuit Module
  • WOODWARD 5466-257 REV.-C - NETCON 5000 MODEL REMOTE TRANSCEIVER I/O MODULE
  • Woodward 8273-101 Rev: A - 2301D Digital Load Sharing and Speed Control
  • WOODWARD 8272-799 - 2301A SPEED CONTROL WITH REMOTE REFERENCE REV:C
  • Woodward 8272-517 - PM Motor Control
  • Woodward 8290-048 8290048 Rev. F - Generator Load Sensor
  • woodward 8273-1012 rev c - 2301e Load Sharing and Speed Control
  • WOODWARD 9905-797 - DIGITAL SYNCHRONIZER AND LOAD CONTROL FOR 3 PHASE GENERATORS
  • WOODWARD 8280-3014 - 723 PLUS DIGITAL CONTROL REV NEW
  • WOODWARD 8440-1884 REV G - GENSET CONTROLLER EASYGEN-2500-5/P1
  • Woodward 8272-683 K - Digital Reference
  • WOODWARD 9907-014 - SPEED CONTROL 2301A REV H
  • Woodward Type UG-8 P/N 037260 - Governor R.P.M 1075-1650 Motor KM58-20
  • WOODWARD 9905-970 - LINKNET 6 CHANNEL 100 OHM RTD Rev:J
  • Woodward 9907-1183 Rev C - Steam Turbine Digital SCREEN 505E Turbine Control
  • Woodward 8440-1614 - GCP-30 Genset Control Package, Rev: F, Type 1, E231544
  • Woodward DC11006-304-024 - ACTUOTOR DYNA ACTUATOR - BARBER-COLMAN
  • Woodward 9905-971 - LINKNET 6 CHANNEL 100 OHM RTD Rev:K
  • Woodward DYNK-10249 - Actuator Controller Kit - DYNA 2000
  • Woodward LR21035 - MFR1 MULTI FUNCTION RELAY REV F
  • Woodward 8440-1831 - EASYGEN 3200-5 P/N: REV. G Gererator Controller
  • Woodward 8272-516 - PM MOTOR CONTROL REV J
  • Woodward 8440-2080 - EASYGEN 2000 genset controller EASYGEN-2300-5/P1
  • Woodward 505DE - Digital Control System
  • Woodward 701 - Digital Speed Control 18-40 VDC 4-20 MA
  • Woodward 8440-1799 - EASYGEN-350 REV B
  • Woodward 8272-582 - Apm Motor Control 100-220v AC/DC
  • Woodward 5501-031 D - 3077-474C 8605895 Circuit Module
  • Woodward XD1-T - XD1T55SAT TRANSFORMER DIFFERENTIAL PROTECTION RELAY
  • Woodward 8272-517 - PM Motor Control 220vac
  • Woodward 8934-658 - Repair Kit UG8D Governor
  • Woodward 5437 18 - module netcon derivative analog rev.A
  • Woodward 8272-171 A - Pm Motor Control
  • Woodward MRN3-1/2 - SEG mains uncoupling relay MRN314D mains decoupling relay
  • Woodward 9905-373 - Digital Synchronizer and Load Control 18-40 VDC Rev P
  • Woodward 5431-640 C - Dual Dynamics 1000 Series Speed Control Module
  • Woodward 5501-031 D - 3077-474C 8605895 Circuit Module
  • Woodward 9907-247 - 828 DIGITAL CONTROL
  • Woodward 8440-1855-G - EASYGEN-2200-5 /P1 12/24VDC GENSET CONTROLLER
  • Woodward NC3-2-8 (NO) - GENERATOR CONTROLLER
  • Woodward 8271-467 K - 2301 LOAD SHARING AND SPEED CONTROL PART NO:
  • Woodward 8440-2177 A - SPM-D2-10 Digital Synchronising Controller
  • Woodward LXMG1614E-14-11 - CCFL and UV Lamps Inverter Module
  • Woodward 8270-990 - signal converter
  • Woodward 9905-068 - LOW VOLTAGE 2301A LOAD SHARING & SPEED CONTOL P/N:
  • Woodward 8901-051 - BOOSTER SERVOMOTOR, SINGLE CYLINDER, 2:1
  • Woodward 8444-1024 D - MWS4-55M CONTROL MODULE UNIT
  • Woodward 5448-914 - GCP-20 Genset Control GCP-20 REV D P/n:
  • Danfoss BHA-1 018-1942 - Hydraulic Actuator
  • Woodward 9905-001 L - SPM-A SYNCHRONIZER
  • Woodward 5464-850 - Module
  • Woodward 5501-371 - Micronet Simplex Mpu Aio Rev C
  • Woodward 8272-132 B - POWER SENSOR
  • Woodward 9907-028 - SPM-A Synchronizer
  • Woodward SA-3678-AM-2 - Overspeed Electric Governor, Model ESSE2-AM
  • Woodward E8250-502 - GOVERNOR ACTUATOR
  • Woodward 8440-1884 J - Controller EASYGEN-2500-5
  • Woodward 5441-693 - DIGITAL I/O MODULE -MISSING PART
  • Woodward SA-4450 - Speed Controller APECS 3100 For Magnetic Pickup
  • Woodward 9903-466 - 701 DIGITAL SPEED CONTROL REV G
  • Woodward 1765-843 - Governor Speed Adjusting Motor P/N Type: SMM40 220V AC 50/60Hz
  • Woodward 9905-760 - Linknet Termination Module
  • Woodward 9907-247 - 828 DIGITAL CONTROL UNIT REV K
  • Woodward 5484-721 - motor
  • Woodward 8440-1734 - MFR-2 Rev.A Multi Function Relay MFR-2
  • Woodward CSC3SUWA - Controller
  • Woodward 8440-1667 - REV B SPM-D1010B/XN
  • Woodward 8406-120 - egcp-2 digital control
  • Woodward DPG-2201-002 - DIGITAL CONTROLLER REV D
  • Woodward 8272-516 - Pm Engine Control Rev J
  • Woodward 8440-1831 - EASYGEN 3200-5 P/N: REV. K - WITHOUT ACCESSORIES
  • Woodward 8273-101 - LOAD SHARING & SPEED CONTROL
  • Woodward 8440-1855-G - EASYGEN-2200-5 /P1 12/24VDC GENSET CONTROLLER
  • Woodward 9907-247 - 828 DIGITAL CONTROL UNIT REV K
  • Woodward LR21035 - MFR1 MULTI FUNCTION RELAY REV J
  • Woodward 8404-009 - PROACT DIGITAL PLUS FRONT PANEL REV J
  • Woodward 9905-204 - Rev N SPM-A synchronizer
  • Woodward 8521-367 - UG-8 P/N r R.P.M 750-1280 Governor / UG8
  • Woodward 9907-175 - Load Sharing Module Rev. B
  • Woodward 5464-645 - DRIVER MODULE REV A 2C ACT DRIVE
  • Woodward 8404-009 - PROACT DIGITAL PLUS FRONT PANEL REV J
  • Woodward 9907-175 - Load Sharing Module Rev. B
  • Woodward 8406-102 - Rev A EGCP-2 Digital Control Engine Generator 8406102
  • Woodward EASYGEN-2500-5 - Controller Genset
  • Woodward 8440-2082 - Controller
  • Woodward 8272-516 - PM MOTOR CONTROL REV J
  • Woodward 9905-373 - Digital Synchronizer and Load Control 18-40 VDC Rev P
  • Woodward 5501-429 - Actuator Controller 25mA 2 Channel , (UPP)
  • Woodward 8440-1869 - SPM-D10 Synchronizing System Control-SPM-D10B/PSY4-F-D
  • Woodward 9907-175 - Load Sharing Module Rev. A
  • Woodward 8200-224 - Servo Position Controller
  • Woodward 9906-619 - 723 PLUS DIGITAL CONTROL ( 8280-604 )
  • Woodward 8440-1519 - EASYGEN PART NO: REV: 4
  • Woodward 5501-371 - REV C MODULE- MICRONET SIMPLEX MPU & AIO FTM
  • Woodward EASYGEN-3200-5/P1 - Generator Controller Module Rev F
  • Woodward 8440-1884K - GENERATOR CONTROLLER EASYGEN-2500-5 REV,K
  • Woodward 5466-353 - REV C NETCON MAIN CHASSIS TRANSCEIVER