Product Overview
Equipment form: 19 inch 4U rack mounted analyzer, compatible with CEM continuous emission monitoring cabinet.
Measurement principle: zirconia ZrO ₂ sensor uses the same sensing technology as the mature OXITEC 5000 in-situ oxygen analyzer; Configure microprocessor and graphical human-machine interface.
Measurement capability: Equipped with a sampling preprocessing system, it can measure wet/dry flue gas, sample gas, and steam, with a minimum detection limit of oxygen content less than 1 ppm.
Typical application scenarios
Smoke emission monitoring CEM;
Inert gas monitoring (detection of trace oxygen in nitrogen and water vapor);
Air separation process;
Food production, monitoring of trace oxygen quality under carbon dioxide atmosphere;
Closed loop control of combustion process.
Core advantages: high measurement accuracy, extremely low detection limit; Fast response speed (<1s); Support two-point calibration; Can quickly respond to changes in process gases and achieve real-time combustion regulation; Equipped with calibration history, sensor remaining life display, and self-monitoring function; The airtight sensor structure has a long service life.
Hardware interface and output
Analog output: Oxygen measurement value, 0/4-20 mA active output, electrically isolated DC.
Digital relay output (relay contacts): fault status, maintenance reminder, range switching, measurement limit 1, measurement limit 2; Maximum 24V AC/DC, maximum 1A resistive load.
Digital input: Optocoupler isolated DC input, used for external range selection; 0-24 VDC.
Communication: Standard basic communication; Optional HART and Fieldbus Foundation fieldbus; RS232/RS485 interface.
Technical parameters
Electricity
Power supply: 115VAC/230VAC ± 10%, 50/60Hz; maximum power consumption of 250VA.
Gas path conditions
Instrument Air Version (External Instrument Air)
Quick connector 6mm trachea; Air source ISO 8573-1 Class 2; Pressure 4-10 bar; Gas consumption is 40-60 L/h.
Built in pump reference air version: The internal pump obtains reference air.
Sample gas/calibration gas interface: Swagelok connector compatible with 6/10mm pipeline
Sample gas temperature: Wet sample gas+120~+300 ℃; Dry sample gas/calibration gas 0~+300 ℃;
Sample gas flow rate 40-60 L/h ± 5%; The sample gas is prohibited from containing flammable components;
Calibration gas 1:20.95% O ₂ ± 2%, balance gas N ₂/instrument air;
Calibration gas 2:2.1% O ₂ ± 2%, equilibrium gas N ₂.
environmental conditions
Working temperature: External instrument air version -20...+55 ℃; Built in pump version -20...+40 ℃;
Protection level IP20; Appearance 19 "4U: 177 × 483 × 400 mm; Weight approximately 12 kg.
Measurement performance
Principle: ZrO ₂ zirconia battery;
Detection limit:<1 ppm;
Two groups of users can configure the range: 0.00%~100.00% O ₂ or ppm range;
Accuracy: ± 0.2% of the reading;
Response time:<1 second.
Compliance Certification
EC compatible with 89/336/EEC; EMC complies with EN50082-2 and EN55011 Class B;
T Ü V certification, meeting Germany's 13.17.BlmShV (requires GASMET CX40000 or equivalent multi-component analyzer).

Optional configuration
Two options for air supply: external instrument air; Built in pump extracts reference air;
Fieldbus: HART/Fieldbus Foundation;
Serial interface RS232/RS485.
System features
Extremely high measurement accuracy
Save complete calibration history records
The display screen shows the expected remaining life of the sensor
Structure of airtightness sensor
Whole machine self-monitoring and diagnosis
Long service life