+086-15305925923

K-WANG

Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

MOTOROLA FLN4235/FCN6650/FCN6599/FLN4235A adapter power supply

From: | Author:Wang | Time :2025-06-09 | 55 visit: | Share:

MOTOROLA FLN4235/FCN6650/FCN6599/FLN4235A adapter power supply

Product specifications

Input parameters: Expected to support wide voltage input, ranging from 100-240V AC, 50/60Hz, and can adapt to different global power standards without the need for additional voltage conversion equipment

Output parameters: The output voltage is specially customized for FLN4235 equipment and may be [specific voltage value] DC. The fluctuation range of the output voltage is controlled at a minimum value, such as ± 0.5%, to ensure stable operation of the equipment.

Electrical characteristics: It has high power conversion efficiency, reduces energy loss during the conversion process, lowers heat generation, and improves the service life of the adapter. Electrical isolation design is adopted between input and output to effectively prevent grid interference from entering the equipment, while avoiding the impact of equipment failure on the grid.


Functional Features

Stable power supply: Advanced voltage stabilization technology and high-quality filtering circuits are used to effectively suppress voltage fluctuations and current ripples, providing stable and pure DC power supply for FLN4235 equipment, ensuring stable operation and optimal performance even in complex power environments.

Intelligent protection: equipped with comprehensive protection mechanisms, including overvoltage protection, overcurrent protection, short circuit protection, and overheating protection. When the output voltage is too high, the load current is too large, the output terminal is short circuited, or the internal temperature exceeds the safe range, the adapter will quickly activate protective measures, automatically cut off the output or reduce power, and protect the equipment and adapter itself from damage.


Application scenarios

Mainly used in scenarios where FLN4235 devices are used, such as specific industrial automation control systems, related equipment in communication base stations, etc. Provide stable power to the FLN4235 controller in industrial automation production lines to ensure stable automation control and data transmission of the production line; At the communication base station, ensure that the FLN4235 communication module is working properly and maintain the stable operation of the communication network.


MOTOROLA FCN6650 adapter power supply

(1) Product specifications

Input parameters: It also supports wide voltage input, ranging from 90-264V AC, 47-63Hz. Compared with FLN4235 adapter power supply, the input voltage range is wider, which can better adapt to areas with large voltage fluctuations. At different input voltages, the input current will automatically adjust according to the device load to ensure efficient operation of the adapter.

(2) Functional Features

Efficient power supply: Designed for the high-performance requirements of FCN6650 equipment, it can provide stable and strong power output, ensuring that the equipment will not experience performance degradation or failure due to insufficient power when processing large amounts of data and complex tasks.

Flexible adaptation: Supports multiple output voltage regulation modes, which can be adjusted through software or hardware settings to adapt to different versions or configurations of FCN6650 devices. At the same time, it has intelligent recognition function, which can automatically detect equipment load, adjust output power, and improve energy utilization efficiency.

(3) Application scenarios

Suitable for scenarios with high requirements for power supply, such as communication equipment in large data centers and core control units in high-end industrial automation systems. Provide stable power to the FCN6650 communication processor in the data center to ensure high-speed data transmission and processing; In the automation production line of high-end manufacturing industry, ensure that the FCN6650 controller accurately controls the production process, improves production efficiency and product quality.


MOTOROLA FCN6599 adapter power supply

(1) Product specifications

Input parameters: The input voltage range is 90-250V AC, 50/60Hz, suitable for most industrial and commercial power environments. Has good power adaptability and can maintain stable power input during voltage fluctuations.

Output parameters: The output voltage is optimized specifically for the FCN6599 device, with a stable output current of up to [X8] A, meeting the conventional power requirements of FCN6599 in industrial control scenarios. Excellent voltage regulation rate, able to quickly stabilize the output voltage when the input voltage and load change. .

(2) Functional Features

Industrial grade reliable power supply: designed for industrial control environments, with high reliability and stability. The built-in surge protection and overvoltage protection functions can effectively resist common power anomalies in industrial sites and protect FCN6599 equipment from damage.

Strong environmental adaptability: The shell is made of high-strength and corrosion-resistant materials, which have certain dustproof and waterproof capabilities, and the protection level may reach IP54 or above. The working temperature range is wide, and it can still work stably in an environment of -20 ℃ -70 ℃, making it suitable for use in harsh industrial environments.

(3) Application scenarios

Widely used in the field of industrial automation control, such as equipment control for factory production lines, monitoring and control of power systems, and process control in the petrochemical industry. To provide stable power for the FCN6599 controller, ensuring precise operation of industrial equipment according to predetermined procedures, and guaranteeing production safety and product quality.


MOTOROLA FLN4235A adapter power supply

(1) Product specifications

Input parameters: The input voltage supports 100-240V AC, 50/60Hz, which is the same as the input voltage range of the FLN4235 adapter power supply. However, there may be some improvement in the optimization of the input current, which can more efficiently power the device under different voltage inputs.

Output parameters: The output voltage is accurately matched with the FLN4235A device, and the output current may increase compared to the FLN4235 adapter power supply to meet the power needs of the FLN4235A device after upgrading or expanding its functions. The output voltage has higher accuracy and the fluctuation range is controlled within ± 0.3%.

Electrical characteristics: Adopting a new generation of power conversion technology, the power conversion efficiency is significantly improved, the electromagnetic shielding design is strengthened, the self electromagnetic radiation is reduced, and the anti-interference ability is improved, providing equipment with purer power supply.

(2) Functional Features

High performance upgrade: customized for the high-performance requirements of FLN4235A equipment. Compared with FLN4235 adapter power supply, it has improved power supply stability, output power, and efficiency, ensuring that FLN4235A equipment can work stably even under high load operation.

Intelligent energy-saving: Equipped with an intelligent energy-saving mode, it automatically reduces its own power consumption and energy waste when the device is in standby or light load state. At the same time, it supports remote monitoring and management functions, and users can view the working status and parameters of the adapter in real time through the network for remote configuration and fault diagnosis.

(3) Application scenarios

Suitable for scenarios with higher requirements for equipment performance and power supply, such as next-generation industrial automation control systems, high-end communication equipment, etc. Provide stable and efficient power to the FLN4235A controller in the automated production line of the smart factory, supporting the intelligent upgrade and efficient operation of the production line; Ensure the stable operation of FLN4235A communication module in high-end communication base stations, and improve the performance and reliability of communication networks.


Installation precautions

(1) Environmental selection

Temperature and humidity: Although these adapter power supplies have different operating temperature ranges, they all need to be installed in a suitable temperature environment to avoid exceeding their respective maximum operating temperatures (such as FLN4235A, which may experience performance degradation in high temperature environments above 70 ℃), and to prevent accelerated aging or even damage to internal components due to overheating. At the same time, the relative humidity of the installation environment should be maintained within the specified range (usually 5% -95% without condensation). A humid environment can easily cause problems such as circuit short circuits and component corrosion. Therefore, a moisture-proof box or dehumidification device can be equipped for the power supply in places with high humidity.

Ventilation and heat dissipation: It is essential to ensure that the installation location is well ventilated, away from heat sources and enclosed spaces with poor ventilation. For example, the power adapter cannot be installed in a completely enclosed metal cabinet without heat dissipation holes, or near large heating equipment that is currently in operation. Good ventilation helps dissipate heat inside the power supply, preventing excessive temperature caused by heat accumulation, which affects the stability and service life of the power supply.

Electromagnetic interference: Stay away from strong electromagnetic interference sources such as large motors, transformers, frequency converters, and other equipment. Strong electromagnetic interference may affect the normal operation of the power supply, leading to unstable output voltage, abnormal noise, and other situations. It is recommended to maintain a distance of at least 1 meter between the installation location and the interference source. If necessary, electromagnetic shielding measures can be taken, such as using a shielding cover to protect the power supply.

(2) Connection operation

Power off operation: Before connecting the power adapter to the device or mains power, it is necessary to ensure that all related equipment has been powered off. It is strictly prohibited to perform wiring operations while the power is on. This not only prevents operators from getting electrocuted, but also avoids the instantaneous current surge caused by live plugging and unplugging, which can damage power adapters and connecting devices.

Interface matching: Carefully check the input and output interface labels of the power adapter to ensure proper connection. When connecting the input interface to the mains power, use a power cord that meets the specifications and confirm that the power plug is in good contact with the socket to avoid safety hazards caused by electrical sparks due to poor contact. When connecting the output interface to the corresponding device (such as FLN4235, FCN6650, etc.), insert it accurately according to the interface shape and pin definition to prevent the device from not working properly or even being damaged due to reverse or incorrect insertion.

Grounding requirements: For power adapters that require grounding, be sure to connect the grounding wire correctly. Good grounding can effectively prevent safety hazards caused by power leakage and enhance the anti-interference ability of the power supply. The grounding wire should be selected with appropriate specifications of wire, and the grounding resistance should comply with relevant standards. Regularly check whether the grounding wire is loose or broken to ensure the reliability of the grounding system.


Precautions for use

(1) Load management

Rated power matching: Strictly use according to the rated output power and current of each adapter power supply, and prohibit overload operation. Overloading may cause severe heating of the power supply, shorten its lifespan, and even lead to safety accidents such as fires. When connecting the device, it is necessary to calculate the total load power of the device to ensure that it does not exceed the rated value of the power adapter. For example, the maximum output current of the FCN6650 adapter power supply is [X5] A. If the total current demand of the connected devices exceeds this value, a higher power supply should be replaced or the number of connected devices should be reduced.

Avoid frequent start stop: Frequently turning on and off the power adapter may generate surge currents, which can impact the internal components of the power supply and affect its performance and service life. If you need to temporarily stop the device from running, you can keep the power supply in standby mode instead of completely shutting it down. For example, in daily work, when leaving the workstation for a short period of time, there is no need to turn off the adapter power, just turn off the equipment.

(2) Voltage adaptation

Input voltage confirmation: Before use, confirm that the input voltage matches the local mains voltage. For adapters that support wide voltage inputs (such as FLN4235, FCN6650, etc.), it is recommended to use a voltage regulator in areas with large voltage fluctuations to ensure that the input voltage remains stable within the normal range. Avoid damaging the power adapter or causing it to malfunction due to high or low input voltage.

Output voltage regulation (if any): For adapters with output voltage regulation function (such as FCN6650), when adjusting the output voltage, it is necessary to follow the operation steps in the user manual, gradually adjust it to the desired voltage value, and avoid adjusting the amplitude too large at once, which may cause damage to the connected equipment. During the adjustment process, the operating status of the equipment should be monitored in real time to ensure that voltage adjustment does not affect the normal operation of the equipment.


Maintenance precautions

(1) Daily inspection

Status indicator light monitoring: Regularly check the working status indicator light of the power adapter. Under normal circumstances, the indicator light should light up or flash according to established rules. If there is abnormal flashing, extinguishing, or abnormal color on, the power supply working status should be checked immediately to determine if there is a fault. For example, if the indicator light is constantly red, it may indicate that the power supply has overvoltage, overcurrent, or short circuit problems, and should be promptly shut down for inspection.

Monitoring of operating parameters: Use professional instruments to detect the output voltage and current of the power supply every month to ensure that they fluctuate within the rated range. If there is a significant deviation in output voltage or current, it is necessary to calibrate or repair it in a timely manner. For some devices that require high power stability, the monitoring frequency can be increased, such as weekly testing.

(2) Cleaning and maintenance

Surface cleaning: Regularly clean the dust on the surface of the power adapter, at least once every quarter. Use a dry, soft brush or vacuum cleaner to remove dust from the power supply casing, avoid wiping with a damp cloth, and prevent moisture from entering the interior of the power supply. In dusty environments, the cleaning frequency should be appropriately increased, such as once a month.

Internal maintenance (professional operation): For power adapters that have been used for a long time, professional personnel need to open the casing every year (with power off and safety ensured), clean the internal dust, and check whether the internal components are loose, deformed, burnt, etc. If any abnormalities are found, please contact professional maintenance personnel in a timely manner for handling. Do not disassemble and repair them at will to avoid causing greater damage.

5V 3A/3000mA DC Universal Power Supply Adapter, 100-240V 50/60Hz AC to ...


  • Alstom vajh13yf1001aba - Automatic Trip Relay 220-250 V
  • ALSTOM Servo Inverter Type:ALSPA MV 1007-IT - - 3.0 kW
  • ALSTOM Cegelec Interface Modnet 1 / MB+ Fbk Mbp S1/S - Interface Module
  • Alstom Input / Output Card I/O Module SA44647.A - Module
  • Alstom Plug-in card Input/Output module SA44650.C - Module
  • ALSTOM Adjustment Module Keypad Alspa MV1000 - Keypad
  • Alstom Operating module Keypad Alspa MV1000 - Keypad
  • Alstom Plug-In Input/Output Module Sa 45629.B - Module
  • ALSTOM Adjustment Module Keyboard Alspa MV1000 - Keyboard
  • ALSTOM Control Set - 15 V 029.069642/26472/1011 - Voltage regulator
  • Alstom Input/Output Card Module SA44650.C - Module
  • Alstom Input / Output Card I/O Module - Module
  • Alsthom Alstom Plug-In Input/Output Module SA41630 B - Module
  • ALSTOM Servo Inverter Type: ALSPA MV 1007-IT - - 3.0 kW
  • Alstom Plug-In Input/Output I/O Module SA44647.A - Module
  • Alstom Plug-In Input/Output Module Sa 45629.B - Module
  • Alstom Plug-in card Input/Output module SA46623.B - Module
  • ALSTOM Control Module Keyboard Alspa MV1000 - Keyboard
  • Alstom Plug-In Input/Output Module SA46623.B - Module
  • Alstom Plug-In Input/Output Module SA44650.C - Module
  • Alstom Plug-In Input/Output Module SA43610.E - Module
  • Alstom Insertion Card Input / Output Module SA43610.E - Module
  • Alsthom Alstom Plug-In Input/Output Module SA41630 B - Module
  • Alstom Plug-In Input/Output I/O Module - Module
  • Alstom Plug-In Input/Output Module SA46623.B - Module
  • Alstom Plug-in card Input/Output I/O module SA44647.A - Module
  • Alstom Plug-in card Input/Output I/O module SA44647.A - Module
  • Alstom Plug-in card Input/Output module SA 45629.B - Module
  • ALSTOM Alspa VF Inverter Type : VF 4004b - - 1.5 Kw
  • Alstom Plug-In Input/Output Module SA46617.B - Module
  • Alstom PS 431 - Control Unit
  • Alstom Plug-In Input/Output Module Sa 46624.A - Module
  • Alstom Plug-In Input/Output Module SA44650.C - Module
  • Alstom Plug-In Input/Output Module SA43610.E - Module
  • ALSTOM Alspa MV1000 Frequency Type : Alspa MV1032 - - 15 Kw
  • Alstom Input/Output Card Module SA46617.B - Module
  • Alstom Input/Output Card Module Sa 45629.B - Module
  • Alstom Input/Output Card Module SA46623.B - Module
  • ALSTOM Servo-Converter Type : ALSPA MV 1007-IT - - 3.0 Kw
  • ALSTOM Frequency Type : ALSPA MD2000 - 43-400 (49-460)
  • ALSTOM Servo-Converter Type : ALSPA MV 1007 - - 3.0kW
  • Alstom PS 431 - Control
  • ALSTOM Alspa Cegelec Guide Value Transmitter 029.087.176/98N115099109 - Transmitter
  • Alstom Input/Output Card Module Sa 46624.A - Module
  • ALSTOM Control Set - 15 V 029.069642/26472/1011 - Voltage regulator
  • ALSTOM Alspa Module Control Set 029.111.890/27347/1018 - Module
  • ALSTOM Alspa Module Control Set 029.063.255/25443/1044 - Module
  • ALSTOM Alspa Cegelec Module Control Set 029.063.292/25943/1008 - Module
  • ALSTOM Microverter D 4-8/500/029.130.005 - Inverter
  • Alstom ISTAT M233 M233X2GUYECAL0A - Measurement unit M233X2GUYECAL0A NEW
  • ALSTOM Alspa Cegelec Guide Value Transmitter 029.087.176/98N115099109 - Transmitter
  • Alstom Input/Output Module SA 46624.A - Plug-in card
  • ALSTOM Cegelec Interface Modnet 1 / MB + Fbk - Mbp S1/S
  • ALSTOM MAE 00-11 - 8 Channel isolated analog i/o termination panel LC11-13 24118b
  • Alstom MMLG01 137945N - Test block electric panel 715209M T&D protection and control
  • ALSTOM Mae 00-11 - Channel Isolated Analog I/O Terminal Panel LC11-13 24118b Al
  • CONVERTEAM S20X4262/50 / S20X426250 - Module
  • CONVERTEAM MV530A4C1A / MV530A4C1A - Inverter
  • CONVERTEAM C100/5302 / C1005302 - Module
  • CONVERTEAM 20X4355B1L / 20X4355B1L - (new without box)
  • CONVERTEAM GM0020002 / GM0020002 - Module
  • CONVERTEAM P111-6052 / P1116052 - Module
  • Alstom PS 431 - Controller
  • ALSTOM Type : Alspa BC 32 - Brake Chopper Unit
  • ALSTOM Alspa MV500 SE23400075/MV502A4C1A - - 0.75kW Inverter
  • Alstom M30-Tx200 DIN931 - Hexagon screw stamped 8A B screw GE Alstom SW 46
  • Alstom Sa 46624.A - Plug-In Input/Output Module
  • ALSTOM Adjustment Module Keyboard Alspa MV1000 - Keyboard
  • Alstom PA20397/2186-03-H01 - Circuit Board
  • Alstom KBCH12001H12MEL 228633J - Relay Differential KBCH120
  • Alstom MMLG01 137945N - TestBlock Electric Panel 715209M T&D Protection & Control
  • Alstom KBCH12001H12MEL 228633J - Differential Relay KBCH120
  • Alstom MMLG01 137945N - Test Block Electrical Panel 715209M T&d Protection &
  • ALSTOM Mae 00-11 - 8 Channel Isolated Analog I/O Terminal Panel LC11-13 24118b
  • Alstom KBCH12001H12MEL 228633J - Differential Relay KBCH120 and extended warranty
  • Alstom MMLG01 137945N - Test Block Electrical Panel 715209M T & D Protection & De
  • Alstom DFI-110-0340F - DFI1100340F Diagnostic Flame Indicator
  • KCGG142 KCGG14201D20EEA - 287362J
  • ALSTOM MAE 00-11 - Channel isolated analog i/o termination panel LC11-13 24118b Al
  • KCGG122 KCGG12201DEED - 463055L and extended warranty
  • Alstom MMLG01 137945N - Test Block Electrical Panel T&D Protection & Control
  • Alstom 3FAFA5100A - Voltage Sensor TN7 112 003 Alstom T&D Protection & Control
  • Used ALSTOM PIB100 F 3BEB0169 - Board
  • Alstom Keypad - Alspa MV 1000
  • Alstom MMLG01 137945N - Test Block Electrical Panel 715209M T & D Protection &
  • ALSTOM PS441 - Overcurrent protection - Used
  • Alstom Power 2506305 - Circuit Board
  • ALSTOM PS431 - CONTROL UNIT
  • ALSTOM MV502S2B1A - 1 pc X Frequency Drive Alspa MV500
  • Alstom 3VAFS5500A - Voltage Sensor TN7105 002 Alstom T&D Protection & Control
  • ALSTOM MV507A2D1A - 1 pc X Frequency Drive Alspa MV500
  • KCGG KCGG12201L20EED - 655002M and extended warranty
  • ALSTOM TRVP059753000 - AGC3X-007 BLOCK ENCODER TRVP05975400
  • KCGG KCGG14202l20EEB - 654833M and extended warranty
  • Alstom 029 204 538 - cegelec Interface RS422/RS232 Alspa MV 1000
  • ALSTOM PIB100 F - 3BEB0169 Board
  • CONVERTEAM 8321-4002 / 83214002 - (new with box)
  • CONVERTEAM MVAJ14D1GA0774A / MVAJ14D1GA0774A - Relay
  • CONVERTEAM 8178-4002 / 81784002 - (new with box)
  • CONVERTEAM QTWIE2-VD4A / QTWIE2VD4A - (new with box)
  • CONVERTEAM A48DI-40DX-B7/95 / A48DI40DXB795 - Meter
  • CONVERTEAM V96LC/0-400RPM / V96LC0400RPM - Meter
  • CONVERTEAM A72DI-5-40X4/95 / A72DI540X495 - Meter
  • CONVERTEAM 8321-4002 / 83214002 - Module
  • CONVERTEAM 029.081-942 / 029081942 - Module
  • CONVERTEAM V96LC/0-600RPM / V96LC0600RPM - Meter
  • CONVERTEAM 20X4524B1L / 20X4524B1L - Module
  • CONVERTEAM EGS3C-ST11001 / EGS3CST11001 - Module
  • CONVERTEAM S8503-4001 / S85034001 - Module
  • CONVERTEAM MVAX12B1DA0752A / MVAX12B1DA0752A - Relay
  • CONVERTEAM 11P408ND8268/7 / 11P408ND82687 - (new without box)
  • CONVERTEAM MVAJ26L1BB0502A / MVAJ26L1BB0502A - Relay
  • CONVERTEAM C100/5120 / C1005120 - Module
  • CONVERTEAM D-984-0578 / D9840578 - Board
  • CONVERTEAM GDS1017-4001 / GDS10174001 - Enhancement Card
  • CONVERTEAM MBC101F1AD0761A / MBC101F1AD0761A - Module
  • CONVERTEAM GDS1006-4001 / GDS10064001 - Keypad
  • CONVERTEAM 25X8521/10 / 25X852110 - Module
  • CONVERTEAM VSELC1011A1AB / VSELC1011A1AB - (new without box)
  • CONVERTEAM RTS-13060102-R / RTS13060102R - Relay
  • CONVERTEAM LGPG-11101P55LEF / LGPG11101P55LEF - Relay
  • CONVERTEAM 203-399 / 203399 - Module
  • CONVERTEAM MV516A4C1 / MV516A4C1 - Inverter
  • CONVERTEAM SW867577-007 / SW867577007 - Module
  • CONVERTEAM MCGG22D1CD0503D / MCGG22D1CD0503D - Relay
  • CONVERTEAM MV506A4C1A / MV506A4C1A - Inverter
  • CONVERTEAM GM0025002 / GM0025002 - Module
  • CONVERTEAM MBCI01F1AD0511A / MBCI01F1AD0511A - Module