K-WANG
HIMA HIMax Flexible Safety for Maximum Profitability
HIMax is a flexible platform for critical production processes that you can never afford to have go down.
HIMax adapts to all I/O-count, response-time and fault-tolerance requirements as well as centralized
and distributed applications. HIMax delivers availability for life by enabling uninterrupted system operation
throughout your plant’s life cycle. Hardware and software changes can be performed without system
interruption. Alternative CPU modules make HIMax suitable for meeting high performance and critical
control requirements as well as for use in small and mid-sized safety applications.
HIMax systems
• SIL 3, PL e
• SIL 4 CENELEC
• Nonstop operation
• Maximum performance
• Maximum configuration
flexibility for life
• Different mechanical concepts
• Small, mid-sized and large
applications
Certificates/standards
• IEC 61508:2010, Part 1–7
• IEC 61511:2004, Part 1–3
• ANSI/ISA-84.00.01-2004
• EN ISO 13849-1:2008 (PL e)
• EN 62061:2005
• EN 50156-1:2004
• EN 12067-2:2004
• EN 298:2012
• EN 61131-2:2007
• EN 61000-6-2:2005
• EN 61000-6-4:2007 + A1:2011
• EN 54-2:1997/A1:2006
• EN 50130-4:1998-2003
• NFPA 72:2010, 85:2011, 86:2011
• EN 60079-15:2010 ATEX (Zone 2, T4),
IEC Ex (Zone 2, T4)
• EN 50271:2010
• EN 50495:2010
• ANSI/ISA-S 71.04 Class G3
(Tropicalization)
• UL (UL 508)
• cUL (CSA-C22.2 No. 142)
• FM CLASS 1 DIV2
• Achilles Level I Certification
• EN 50126:1999 (SIL 4)
• EN 50129:2003 (SIL 4)
• EN 50128:2011 (SIL 4)
• BUREAU VERITAS
• DNV (DET NORSKE VERITAS)
• Lloyd’s Register Type Approval
• Russia EAC
• ABS Design Assessment
Additional certificates available
on website
List of Modules
Highlights
• XMR architecture and integrated redundancy management deliver “availability for life”
• Unique common-cause protection
• All changes, additions and maintenance procedures are possible without stopping
a HIMax system
• CPU self-educates when processor module is replaced
• Proof tests can be conducted online
• Stores up to 2,500 diagnostic entries in the processor module and 500 entries per
I/O module automatically
• Multitasking – run up to 32 user programs simultaneously
• Sequence of event (SOE), storage for 5,000 events, 1 ms resolution quality
• Redundant integrated and protected power distribution
• Two or three wiring inputs/outputs per channel to help eliminate additional wiring
• Remote rack functionality enables star topology
• HIMax – HIMatrix PES, redundant link via SafeEthernet
• Optimize process simulation and operator training with the HIMax Safety Simulator X-OTS
HIMax Modules Type Description
Central modules
Processor module X-CPU 01 For high performance and critical control requirements
Processor module X-CPU 31 For small and mid-sized safety applications
System bus module X-SB 01 –
Communication module X-COM 01 4 x RJ-45, 2 x 9-pole D-Sub, up to 6 different protocols
Input/output modules
Input modules
Digital input module X-DI 64 01 64 channels, 24 VDC, SIL 3
Digital input module X-DI 64 51 64 channels, 24 VDC
Digital input module X-DI 32 01 32 channels, 24 VDC, SIL 3
Digital input module X-DI 32 02 32 channels, 8.2 VDC, proximity switch, line monitoring, SIL 3
Digital input module X-DI 32 03 32 channels, 48 VDC, SIL 3
Digital input module X-DI 32 04 32 channels, 24 VDC, SOE, SIL 3
Digital input module X-DI 32 05 32 channels, 8.2 VDC, proximity switch, line monitoring, SOE, SIL 3
Digital input module X-DI 32 51 16 channels, 120 VAC, SIL 3
Digital input module X-DI 32 52 32 channels, 8.2 VDC, proximity switch, line monitoring
Digital input module X-DI 16 01 16 channels, 120 VAC, SIL 3
Analog input module X-AI 16 51 16 channels, 0/4
Typical applications
• Emergency Shutdown
Systems (ESD)
• Fire & Gas Systems (F&G)/
(Gas Warning Systems)
• High Integrity Pressure
Protection Systems (HIPPS)
• Pipeline Management &
Control (PMC)
• Turbo Machinery Control
(TMC)
• Burner Control Systems
and Boiler Protection (BCS)
• Interlocking
• Level Crossings
• Rolling Stock
SILworX
• Function Block Diagrams
• Sequential Function Charts
• ST (Structured Text)
• C-Code (Optional)
Operating principles
• De-energize to trip
• Energize to trip
Communication options
Additionally each COM can
simultaneously operate up to
6 protocols from the following
list:
• SafeEthernet
• OPC DA (OPC A&E)
• Modbus TCP Master & Slave
• PROFINET and PROFIsafe
• Modbus RS485 Master &
Slave
• PROFIBUS DP Master &
Slave
• Send & Receive TCP
• ComUserTask (CUT),
user-programmable port
RS422, RS485, UDP, TCP,
SNTP
• HART over IP (V7)