K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

Hirschmann OCTOPUS OS20/OS24 Network Managed IP65/IP67 Industrial Switch Installation Manual

From: | Author:Wang | Time :2026-06-22 | 196 visit: | 🔊 Click to read aloud ❚❚ ▶ | Share:


Hirschmann OCTOPUS OS20/OS24 Network Managed IP65/IP67 Industrial Switch Installation Manual

Product overall definition and model code

Product line differentiation

Model PoE Capability Port Overall Configuration

OS20 without PoE 9-way M12 100Mbps electrical port (2-channel uplink T5 M12)

OS24 PoE+IEEE802.3at 9-way M12 100Mbps, with a total of 8 ports 2-9 supporting PoE. The total PoE output limit of the whole machine is 61.6W

Complete model code segmented interpretation

Series: OS20 (without PoE)/OS24 (PoE+)

00=no gigabit port; 08=8 PoE ports

09=9 100M M12 electrical ports

00=no gigabit; T5=100Mbps M12 upstream port (2)

Temperature range T: -40 ℃~+70 ℃ Wide temperature range

Power supply: A (5-core M12, 9.6-60VDC), F (5/7/8 connector 16.8-60VDC), N (4-core 7/8 connector 50.4-138VDC locomotive high voltage)

Certification E (Rail Vehicle)/F (Rail+Ship GL)

B Basic firmware, HH=IP65/67 sealed machine

Whole machine hardware layout (unified panel)

Power connector: A=5-core M12; F/N=7/8 industrial connector, dual redundant P1/P2;

FAULT passive M12 signal relay terminal;

V. 24. Debug M12 serial port (ACA11 adapter/CLI console);

9 D-encoded M12 100Mbps electrical ports (8 ports PoE after OS24);

Global LED of the whole machine (P1/P2 power supply, RM ring network, FAULT fault);

Each port has an independent LS link, DA data, and PoE indicator light;

M3/M4 grounding screw, IP sealed housing, MAC/IP identification area.

Whole machine management method

Local: M12 V.24 serial port (9600 8N1), ACA11 configuration adapter;

Remote: Web pages Telnet; Batch operation and maintenance of HiDiscovery/Industrial HiVision;

Core software: HIPER Ring self-healing ring RSTP、 Port isolation, link monitoring, PoE power management.


Detailed parameters of the three major types of power supply

Type A (5-core M12 connector)

Rated 24-48VDC, operating range 9.6~60VDC, dual redundant, 0.6Nm tightening torque, standard ELWIKA 5-core M12 connector.

F-type (5-pin 7/8 "connector)

Rated 24-48VDC, wide range of 16.8-60VDC, suitable for PoE models; The power cord needs to pass through the matching magnetic ring for 3 turns, tightly adhere to the equipment to reduce EM interference, and have a torque of 2.5Nm.

N-type (4-pin 7/8 "locomotive specific)

High voltage DC 50.4~138VDC (nominal 72-110V), dedicated for rail locomotives, with a tightening torque of 2.5Nm, limited to installation in restricted machine rooms only.

FAULT Passive Relay Function

Normally closed contact, report disconnection in case of fault: loss of one/two power sources, interruption of port links, machine self-test fault, abnormal HIPER Ring network configuration; The web interface allows manual control of relay external alarm devices. Contact maximum 1A/48VDC resistive load.


Port specification (M12 D encoding)

Ordinary 100Mbps M12:10/100M, automatic negotiation/automatic line sequence/automatic polarity, Cat5e shielded cable up to 100m long; 4-pin D-code M12.

OS24 PoE port: IEEE802.3at 30W phantom power supply, 1/3, 2/4 wire pair output, total power limit of 61.6W, overload automatically cuts off port power supply; There is no electrical isolation between PoE ports, and the ring network needs to mix non PoE ports to avoid potential differences.

V. 24 Debugging M12: Define TX/RX/GND with 4 pins and adapt to VT100 terminals.

Complete definition of LED indicator lights

Global indicator light for the entire machine

P1/P2 green light is always on: corresponding power supply is normal; Extinguish=undervoltage;

RM Ring Network Manager: Off=Ring Network Closed; Evergreen=RM enabled, redundant ports disabled; Huang Changliang=redundant port activated; Flashing=Loop network wiring/configuration error;

FAULT red light is always on: there is a fault alarm; Extinguish=The whole machine is normal.

Single port indicator light

LS green light constantly on=link connected; Cycle 1 flash=port standby; 3 flashes=port closed;

DA yellow light flashing=transmitting and receiving data; No flicker=no flow;

PoE green light always on=terminal power supply; 1 flicker=complete machine power overload and power outage; 3 flashes=Web manually turns off PoE output.


Complete installation and wiring process

Open box inspection: Check the host, matching connectors, magnetic ring (F model), sealing protection screws, safety manual, and verify that the housing seal is not damaged;

Flat fixing: M5 screws for flat wall/cabinet installation, with reserved space for upper, lower, left, and right heat dissipation;

Grounding: M3/M4 grounding screw with tooth pad, ground wire ≥ 0.75mm ², priority grounding;

power wiring

Type A: 5-core M12 connected to dual DC+FAULT;

F-type: 7/8 power connector, power cord threaded through magnetic ring three times close to the body;

N-type: locomotive 4-core 7/8 high-voltage connector;

All connectors should be tightened with the specified torque, and unused interfaces should be equipped with sealing plugs;

Fault signal terminal M12 wiring;

M12 Ethernet cable access: Shielded Ethernet cable shell connected to equipment ground, strong and weak electrical wiring divided into slots, cross 90 ° to reduce interference;

Power on self-test: After about 30 seconds of power on, the whole machine self-test is completed, and the LED flashes in full sequence before it is ready.


Factory default basic configuration

IP address: default DHCP automatic acquisition;

Account: admin (read-write, password private), user (read-only, public); It is recommended to change the high-strength password for the first login;

V. 24 serial port: 9600 baud, 8 data bits, 1 stop bit, no checksum;

Port: auto negotiation enabled, PoE enabled by default;

Redundancy: RSTP enabled, HIPER Ring disabled, link alarm disabled.


Maintenance, temperature monitoring, and disassembly

The consumable parts are only FAULT relays, and the contact resistance is regularly checked in high-frequency scenarios;

The device CLI/Web can read the internal temperature, which is higher than the environment; The upper limit of the bottom plate temperature for PoE models is 90 ℃, and if the temperature exceeds the limit, the PoE power will be reduced;

Regularly check the integrity of M12 sealing plugs to avoid water and dust ingress; Official website firmware update fixes vulnerabilities;

Dismantling sequence: Disconnect all cables first → Remove the ground wire → Loosen the fixing screws and remove the entire machine; Immediately install protective screws on the idle interface.


Core mechanical and electrical technical parameters

Physical specifications

Fixed overall size, weight 1900g; IP65/IP67 protection, no fan; Flat M5 screw installation without DIN buckle.

Power supply and power consumption

Type A: Maximum power consumption of 6.7W;

N high-voltage model: 12W;

The maximum power output of the OS24 PoE machine is 80W, and the upper limit of PoE output is 61.6W;

Input built-in slow melting non replaceable fuse, power down buffer>10ms.

Environmental conditions

Working temperature -40 ℃~+70 ℃; Storage -40~+85 ℃; Condensation can occur when the humidity is between 5% and 100%; The highest altitude is 2000m, with a pollution level of 2.

transmission distance

Shielding Cat5e twisted pair cables up to 100m.

Supporting accessories

Various M12 connectors, 7/8 power connectors, EMC magnetic rings, sealing protection screws, ACA11-M12 configuration adapters, M12 to RJ45 adapters, HiVision network management software.


Industry certification and implementation standards

Safety UL60950-1, CE, FCC; Rail transit EN50155/EN50121; Ship GL classification; Industrial EMC complete set of anti-interference standards; RoHS Environmental Directive.

  • ALPHA WIRE 1636-RD001 - Hook-Up Wire
  • FANUC A06B-6078-H211#H501 / A06B6078H211H501 - Servo Amplifier Module
  • Alpha H47016 / CA400 - 400W Switching Power Supply Unit
  • Alpha Wire 2821/2 WH001 - Multi-Conductor Communication Control Cable
  • Wittenstein Alpha SP 100S-MF2-25-1E1-2S - Planetary Gearbox Reducer
  • FANUC A06B-6090-H008 / A06B6090H008 - Servo Power Supply Module
  • Alpha Wire 2821/2 WH001 - Multi-Conductor Communication Control Cable
  • NOVOTRON / Alpha NBL2-0080-45-3-320 T0B + SP075-MF1-3-031-000 - Servo Motor with Planetary Gearbox
  • Alpha 0100044-001 CXRF 48/4.6KW - Rectifier Module
  • Lambada-TDK / Alpha YM-00-470B / AMAT 50513215200 - 600W Power Supply Unit
  • FANUC A06B-6290-H122 - Alpha iSV 10HV-B 3-Axis Servo Amplifier Drive
  • Alpha SP 140S-MF1-5-1/1-2S - Planetary Gearbox Reducer
  • Wittenstein Alpha SP 100S-MF1-5-1K1-2S - Planetary Gearbox Reducer
  • Wittenstein Alpha LP 120Z-MF1-10-1/1-3S-INF - LP Series Planetary Gearbox
  • Wittenstein Alpha LP 090-M01-7-111-000 / Schneider - Planetary Gearbox with Servo Motor
  • Alpha TP 050-MX1-7-450-000 - Gearbox Reducer
  • Fanuc A06B-0377-B577#7000 - AC Servo Motor Alpha M2.5/3000
  • ALPHA WIRE 1705-SL001 - Hook-Up Wire
  • ALPHA WIRE 1953/3T-BK003 - Hook-Up Wire
  • ALPHA WIRE 5855/7-SL001 - Hook-Up Wire
  • ALPHA WIRE 2158-NA005 - Hook-Up Wire
  • Wittenstein Alpha TP 025S-MF1-7-0G0-2S - Planetary Gearbox
  • ALPHA WIRE 5356C - 37 Conductor 20AWG Foil & Braid Shield Cable
  • Wittenstein Alpha NP 025S-MF1-5-1G1-1S - Planetary Gearbox
  • Allen Bradley / Alpha N-3412-2-H00AA / LP 120-M02-100-111-000 - Servo Motor with Planetary Gearbox
  • FANUC A06B-6089-H204 - Alpha Series Servo Amplifier Module
  • Man Diesel & Turbo 3157168-7 - Alpha Lubricator Sbu
  • FANUC A20B-2100-0742 - ALPHA ia Servo Control Board
  • ALPHA ALPHA6000E-31R5GB - Frequency Inverter Drive Power Converter
  • Alpha Industries G287775-1 / 5985-01-341-9652 - Variable Attenuator
  • FANUC A06B-6124-H206 - Alpha iSV Servo Amplifier Module
  • Wittenstein Alpha NP 025S-MF1-5-1G1-1S - Planetary Gearbox
  • NOVOTRON / Alpha NBL2-0080-45-0-320-B-S-A + SK060-MF1-3-031-000 - Servo Motor with Alpha Gearbox
  • FANUC A20B-2100-0742 - ALPHA ia Servo Control Board
  • Honeywell CK65-L0N-BLC210F / CK65 - Mobile Computer Barcode Scanner
  • Wittenstein Alpha TK+ 004S-MF2-12-5B1-1S10 - Right Angle Gearbox
  • FANUC A20B-2100-0742 - ALPHA ia Servo Control Board
  • Rexroth MSK071E-0450-NN-M1-UG1-NNNN - 3-Phase AC Motor with Alpha Reducer
  • JAVAD ALPHA2 - GPS Receiver GrAnt G3
  • GROSCHOPP / Alpha WK 1621309 / EK 66-45 NR + TP 010-MF2-61-030-000 - Motor with Alpha Gearbox Construction
  • ALPHA WIRE 5060C-SL005 - Multi-Conductor Cable Wire
  • ALPHA B10 K X 2 T80887 - Potentiometer
  • Alpha 400W J40005 - Switching Power Supply Unit
  • FANUC A20B-1007-0650 - ALPHA Power Supply Module Board
  • Eberline HP-100B - Gas Proportional Alpha Beta Probe GM Geiger Counter
  • ALPHA WIRE 5858-BK001 - Single Conductor Hook-Up Wire
  • FANUC A06B-6127-H103 - Alpha I AiSV-20HV Servo Amplifier Module
  • VIASYS / CareFusion SOMNOSTAR CEPHALO PRO - Portable EEG Neurodiagnostic Sleep System
  • DSI Surgical Instruments Universal - Dental Implant Abutment Surgical Instruments Kit
  • FANUC A06B-6078-H211#H501 / A06B6078H211H501 - Servo Amplifier Module
  • Fanuc A06B-6089-H209 - Alpha Series Servo Amplifier Module
  • Generic / DSI Straight Anatomic Plastic Adapter Head + Screw Hex - Dental Implant Fixture
  • FANUC A20B-1006-0680 - ALPHA Power Supply Module Board
  • B&L Biotech Alpha II - Endodontic Starter Kit
  • FANUC A06B-0166-B088 C009A5653 - AC Servo Motor
  • ALPHA WIRE 74010-BK002 - Multi-Conductor Cable Wire
  • Wittenstein Alpha SPK 100-MF2-10-041-000 - Gear Box Reducer Ratio 10:1
  • Alpha Getriebebau 10-FL-M1-5 - 10:1 Ratio 7/8 Inch Shaft Gear Reducer
  • ALPHA WIRE 2172-SV005 - Multi-Conductor Cable Wire
  • Aloka UST-5410 - Linear Array Probe Compatible Transducer
  • Alpha Xtra-Guard 1 SupraShield - Multiconductor Cable 16 AWG 2 Conductor
  • ALPHA ALPHA7000E-37R5GB/3011PB - Frequency Inverter Drive Power Converter
  • SIEMENS / Alpha 1FT5066 / SP 100 ROD 426B - Servo Motor with Actuator
  • FANUC A06B-6089-H210 / A06B6089H210 - Servo Amplifier Module
  • LAMBDA ALPHA 600W H60553 - Switching Power Supply Unit
  • Alpha 400W J40071A - Switching Power Supply Unit
  • Hyva Alpha Series FC A4.5-3-98-K6-1DA-HC / 70593139 - Dump Body Hydraulic Cylinder
  • ALPHA WIRE 1293C-SL001 - Multi-Conductor Cable Wire
  • NSS Galaxy / Alpha 20 and 16 - Floor Strip and Wax Slow Speed Buffer and Wet Vac
  • Alpha Xtra-Guard 1 SupraShield - Multiconductor Cable 16 AWG 2 Conductor
  • ALPHA ALPHA6000-3015JB - Frequency Inverter Drive Power Converter
  • Densei-Lambda MA4000591A/ME Alpha 400 / MV6500271A Alpha II-650 - Power Supply Unit
  • Wittenstein Alpha SP 140G-MF2-28-0E1-2S-PGG - Planetary Gear Reducer
  • FANUC ROBOCUT ALPHA-1iC - CNC Wire EDM Machine
  • Fanuc A06B-6081-H101 - Alpha Series Power Supply Module PSMR-1
  • ALPHA WIRE 5855-BL001 - Hook-Up Wire
  • Wittenstein Alpha SPK 100-MF2-20-141-000 - Right Angle Gear Reducer 20:1 Ratio
  • LNS ALPHA SL65-S - Bar Feed System
  • ALPHA WIRE 5356C - 37 Conductor 20AWG Foil & Braided Shield TC Shield Cable
  • TDK-Lambda / Alpha H60552 - 600W Switching Power Supply Unit
  • Bruker Alpha - Infrared Spectrometer FTIR Instrument
  • Wittenstein Alpha SP 060S-MF1-7-0B1-2S - Planetary Gearbox Reducer
  • Digital Alpha VME 5/480 - VME SBC Motherboard CPU Board
  • Glentek Alpha Series - Digital Brushless Servo Amplifier Drive
  • Wittenstein Alpha TPM 004S-021M-6KB1-053B-G6 - Rotary Servo Actuator
  • Wittenstein Alpha TP 110-MF2-61-031-000 / 20009377 - Planetary Gearbox Reducer
  • Emerson Alpha 1800 24 60 / 5070800001 - Rectifier Power Module
  • Fanuc A06B-0377-B577#7000 - AC Servo Motor Alpha M2.5/3000
  • Novotron / Alpha NBL2-0080-45-3-320 T0B + SP075 - Servo Motor with Alpha Gearbox
  • Alpha & Omega Semiconductor AOD442 - N-Channel MOSFET Reel Surface Mount
  • Alpha Wire 2156-NA005 - Hook-Up Wire Cable
  • Sankyo 15AD-04277R-LR3VW1 - Rotary Indexer with Motor
  • Wittenstein Alpha TP025S-MF1-7-0G0-2S - Planetary Gearbox i=7
  • Fanuc A20B-2001-0950 - Control Circuit Board PCB
  • TDK-Lambda / Alpha H60553 - 600W Switching Power Supply Unit
  • Alpha Wire 391845-WH001 - Hook-Up Wire Cable
  • Wittenstein Alpha SPK 100-MF2-10-041-000 - Gear Box Reducer Ratio 10:1
  • Novotron / Alpha NBL2-0080-45-0-320-B-S-A + SK060 - Servo Motor with Alpha Gearhead
  • Wittenstein Alpha TP050S-MA2-27.5-0G1-2S - Planetary Gearbox Reducer
  • Fanuc A06B-6096-H305 - Alpha Servo Amplifier Module
  • TDK-Lambda / Alpha H47006 / CA400 - 400W Switching Power Supply
  • Wittenstein Alpha SPK140 MF2-10-051-000 - Bevel Planetary Gearbox Reducer
  • Fanuc A06B-6117-H205 - Alpha iSV Servo Amplifier Module
  • Fanuc A20B-1007-0650 - Alpha Power Supply Module Board PCB
  • Alpha Wire 2248C-SL005 - Multi-Conductor Cable Wire
  • Alpha Wire 6829-BK001 - Hook-Up Wire Cable
  • Wittenstein Alpha SPK+100S-MF2-25-1E1-1K01 - Right Angle Planetary Gearbox Reducer
  • MAN B&W 99100724 - Maintenance Tools Set for Alpha Lubricator
  • Tokyo Electron (TEL) A3619-9215E / Vexta - Carrier Transfer Assembly
  • Tokyo Electron (TEL) Alpha 8 Auto Shutter 200mm - Diffusion Furnace Auto Shutter Assembly
  • Fanuc A06B-6089-H105 - Alpha Series Servo Amplifier Module
  • Aikoku Alpha EZ Amplifier Type Z - Servo Amplifier Drive
  • Fanuc A06B-6096-H204 - Dual Axis Alpha Servo Amplifier Module
  • Ferrocontrol / Alpha Getriebebau FMR063-04-60-RMK-B0 - Servo Controller with Gear Reducer
  • Fanuc A20B-1006-0680 - Alpha Power Supply Module Board PCB
  • Wittenstein Alpha SP 140S-MF1-5-0I1-2S / 20027211 - Servo Speed Reducer Gearbox
  • Stanley / Alpha 21A108721 - QMP Controller Unit
  • TDK-Lambda / Alpha J40071A - 400W Switching Power Supply Unit
  • Fanuc A06B-0235-B300 - AC Servo Motor Alpha iFS 8/4000
  • Tokyo Electron (TEL) Alpha 8s Manifold Flange Plenum - Right Side Ports Manifold Flange
  • Fuji Frontier 570 PS1 / Alpha 650II - Power Supply Assembly
  • Tokyo Electron (TEL) WCIF-01A - T-Bawl Control Unit PCB Assembly
  • Fanuc A06B-6079-H106 - Alpha Servo Drive Amplifier Module
  • Fanuc A06B-6096-H204 - Dual Axis Alpha Servo Amplifier Module
  • Fanuc A06B-6114-H302 - Triple Axis Servo Drive Amplifier Module
  • Fanuc A06B-6110-H015 - Alpha Servo Amplifier Module
  • Hitachi Aloka Prosound Alpha 7 Premier - Diagnostic Ultrasound System
  • Alpha BC35 - Canning Line for Carbonated Beverages Beer RTD