Huichuan MCTC-ARD-C Elevator Automatic Rescue Device (ARD)

From: | Author:Wang | Time :2026-04-21 | 113 visit: | 🔊 Click to read aloud ❚❚ | Share:


Huichuan MCTC-ARD-C Elevator Automatic Rescue Device (ARD)

Product positioning and core functions

Product positioning

MCTC-ARD-C is an elevator automatic rescue device (ARD) independently developed by Huichuan

Perfectly compatible with Huichuan NICE series elevator controller

Core function: Automatic emergency rescue in case of power outage/phase loss in the city

work logic

Normal: Monitor the mains power and charge the battery

Exception: Power outage/phase loss detected for 200ms, confirmed before starting

Rescue: Output emergency power → Drive elevator in light load direction → Open door and release personnel on the nearest floor

Recovery: Automatically switch back to the main power supply after the mains power is normal


Model and specifications

1. Naming rules for models

MCTC C ARD 40 15

40: Three phase 380V; 20:220V

15:15kW;30:30kW

2. Core technical parameters

Parameter specifications

Input voltage three-phase 380~440VAC, 50/60Hz

Output voltage single-phase 380VAC, 50 ± 5Hz

Adaptive power 4015: ≤ 15kW; 4030:≤30kW

Battery configuration 12V x 3 cells x 7Ah

Emergency time limit: maximum operation time of 3 minutes, automatic stop

Protection level IP20

Working temperature -10 ℃~+40 ℃

Altitude<1000m (over 1000m requires capacity reduction)


Main components

Component specifications/models

MCB ARD3T153U1

Drive board ARD3T153M1

Battery 12V × 3 × 7Ah (Lishi DJW12-7.0)

Contactor (15kW) 3RT6028-1AN20380V/38A

Contactor (30kW) 3RT50-36-1AN20380V/50A

Air switch DZ47N, 400VAC/63A


Terminal and DIP settings

1. Key terminal functions

Terminal type identification function

Power input L1/L2/L3/N/PE mains three-phase input

Power output R/S/T connected to elevator control cabinet

Emergency operation start signal for control terminal Y1

X1 emergency operation completion signal

24V/COM external power supply and common terminal

CANH/CANL reserved communication

2. DIP switches K1/K2 (factory default 380V three-phase)

K1 K2 configuration

OFF ON three-phase 380V (default)

ON OFF single-phase 220V

ON, three-phase 220V

3. Protection switch

K4: Battery output cut-off switch

K5: Complete machine charging/power supply air switch

Installation specifications

Installation method

Wall mounted/floor standing

Installation location: inside the elevator machine room or shaft

Installation size (representative model)

Model Width W Depth D Height H Weight

4015 wall mounted 248mm 151.2mm 480mm 15kg

4030 wall mounted 303mm 151.2mm 480mm 17kg

Environmental Requirements

No conductive dust, corrosive/flammable gases

Humidity<95% RH (no condensation)

Natural ventilation and heat dissipation


Debugging process

Before powering on

K4 and K5 are turned off

Check wiring: Input/output must not be reversed

power on

Close K5 → Install panel → Close K4 → Close main power

Check battery: 3-4 grid battery level lights are on

Emergency testing

The elevator is located on the middle floor

Cut off the main power supply and verify automatic rescue


Maintenance and battery replacement

Precautions for battery replacement

The entire machine must be powered off for operation

Prohibition of short circuit/reverse connection between positive and negative poles

Use an insulated screwdriver

Battery specification: 12V x 3 cells, 7Ah

warranty

2-year limited warranty

Artificial damage and unauthorized modifications are not covered by the warranty


Fault diagnosis

1. Indicator light description

Power indicator: 25% per grid; The left light flashes while charging

Fault light: constantly on/flashing indicates a fault

2. Common faults and their solutions

Methods for handling the causes of fault phenomena

Output short circuit/overcurrent wiring error, load short circuit. After troubleshooting, power on again

Over temperature protection: The radiator automatically recovers when it reaches 90 ℃ and cools down to below 82 ℃

Battery undervoltage discharge < 28VDC, charging after mains power recovery

Unable to activate emergency K4/K5 not closed, battery depletion<27V, close or replace battery


Key issues

Question 1: What is the complete emergency rescue process for MCTC-ARD-C? How to handle timeout?

answer

Detected power outage/phase loss, confirmed for 200ms

ARD battery discharge, output 380VAC emergency power supply

Send Y1 emergency start signal to elevator controller

The controller drives the elevator to run in the direction of light load until the nearest floor opens the door

Stop output and exit emergency mode upon receiving X1 completion signal

If no completion signal is received within 3 minutes, the output protection will be automatically forced to stop

Question 2: What are the consequences of reversing the input and output of ARD? How to avoid it?

answer

Consequence: Direct damage to the internal motherboard and power components of ARD, irreparable

Avoidance methods:

Strictly follow the terminal definition for wiring: L1/L2/L3=mains input, R/S/T=output to elevator

Double check after wiring

Before powering on, check the phase and line sequence with a multimeter

Question 3: What is the threshold for determining that the ARD battery cannot be rescued due to low power? How to recover?

answer

Discharge protection threshold: < 28VDC → stop output, rescue prohibited

Power loss judgment during startup: < 27VDC → Fault light on, unable to start

Recovery method:

Restore mains power, ARD automatic charging

After charging, it still cannot be used. Replace it with 3 standard 12V 7Ah batteries

  • Woodward 8272-796 - Real Power Sensor Module 115/230v-ac
  • Woodward 5463-873 - NetCon Output Module
  • Woodward 8271-567 - Load Sensor Module 120/208v-ac
  • Woodward Type UG-8 P/N 8522-300 EG - Governor R.P.M 1075-1650 With Motor Groschopp
  • WOODWARD 9905-971 REV J - LINKNET 16 CHANNEL DISCRETE INPUT MODULE
  • WOODWARD 8280-3014 - 723 PLUS DIGITAL CONTROL REV NEW
  • Woodward 505DE - Digital Control System
  • Woodward 5453-750 - Ethernet Interface FTM
  • Woodward 9907-018 Rev H - 2301A Load Sharing & Speed Control
  • WOODWARD 5420-1080 V4.3 - BOARD-PPA WITHBOX
  • Woodward b 8271-347SP - 2301 speed control
  • Woodward 9905-795 Rev B - Digital Synchronizer and Load Control
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8272-582 - Generator speed control module
  • WOODWARD 9907-247 REV K - 828 DIGITAL CONTROL UNIT
  • WOODWARD 5466-353 REV C - NETCON MAIN CHASSIS TRANSCEIVER
  • Woodward Type UG-8 P/N 8524-708 - Governor 760-1560 Governor R.P.M
  • WOODWARD 9907-247 REV K - 828 DIGITAL CONTROL UNIT
  • WOODWARD 8440-1831 REV. H - EASYGEN3000 3200-5 - WITHOUT ACCESSORIES
  • WOODWARD 8444-1002 REV G - UMT1 MEASURING TRANSDUCERS
  • Woodward 5410-312C - Digital Marine Control Printed Circuit Board
  • Woodward 9905-799 REV F - Digital Synchronizer & Load Control , V#456
  • Woodward 9907-014 - 2301A for controller
  • Woodward Type UG-8 P/N B522-446 - Governor R.P.M 500-1200
  • WOODWARD 8272-221 REV.B - DIGITAL REFERENCE UNIT
  • Woodward 8901-037 - Booster Servomotor Single
  • WOODWARD 8444-1019 REV G - UMT 1 MEASURING TRANSDUCER
  • WOODWARD 1767-367 Z21 WK 0920702 - GOVERNOR MOTOR 2700 RPM KM 58-20 K 230V
  • WOODWARD 9905-972 Rev:G - LINKNET 6 CHANNEL 4-20mA OutPut
  • Woodward E8250-501 - Actuator Governor
  • LTI Drives CDF30.002.C0.7 Compact Servo Controller 08685963 DC 24V Industrial Module
  • LUST LTI Drives CDB32.008.W2.4.BR.PC1 Servo Drive Industrial Motion System
  • LUST LTI Drives CDB34.003.C2.4.PC1.H15 Servo Motor Driver Industrial Control Unit
  • LUST LTI Drives CDA32.004.C1.4.H08.B0 Servo Drive Mat. 3084456 Industrial Control
  • LUST LTI Drives CDE34.005.W2.2 Industrial Servo Drive Motion Control Unit
  • LUST LTI Drives CDA34.006.W3.0 Servo Drive Software V3.70-04 Industrial Controller
  • LTI Drives CDB32.004.C2.4.SH Servo Drive Compact Motion Controller
  • Woodward 9905-373 - Digital Synchronizer And Load Controller
  • WOODWARD MAGNETIC PICKUPS - Sensor
  • WOODWARD GCP-30 - Steuertafel for Industrial Regulator Genset Control Package
  • WOODWARD GOVERNOR 9907-1183 REV A - 505 ENHANCED TURBINE CONTROL
  • WOODWARD 9907-173 REV B - Module Load Sharing 120 Volt
  • WOODWARD 9907-014 - 2301A controller
  • Woodward 9905-029 - SPM-A Synchronizer Module Rev C
  • WOODWARD 8440-1799 EASYGEN-350 REV B - Genset Controller
  • WOODWARD 5466-258 REV M - SIMPLEX DISCRETE I/O MODULE
  • Woodward 8440-1884 C - Controller Easygen 2500-5
  • Woodward 8441-1153 - Monitoring Unit 250VAC
  • WOODWARD 8406-120 REV G - EGCP-2 DIGITAL CONTROL
  • Woodward 8273-584 - Atlas-ii Digital Control
  • Woodward 8272-582 - APM Motor Control 8272582
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8272-517 - Pm Motor Control
  • WOODWARD 9905-797 REV.B - DIGITAL SYNCHRONIZER AND LOAD CONTROL DSLC-D
  • WOODWARD 8272-582 - APM MOTOR CONTROL
  • Woodward Seg FP2-8-24 - Emergency Power Telecommunications Module NP2
  • WOODWARD 2001-12E2U1B1S1A - Fuel Shut Off Valve Stop Solenoid Valve 2000-4505
  • Woodward 8440-1884 K - Genset Controller Easygen-2500-5
  • Woodward 9905-760 - Linknet Termination Module
  • Woodward 8404-009 - Proact Digital Plus Front Panel Rev. H
  • Woodward 8271-651 - Digital Speed Reference
  • Woodward 3077-474C - 8605895 5501-031 D Circuit Module
  • WOODWARD 5466-257 REV.-C - NETCON 5000 MODEL REMOTE TRANSCEIVER I/O MODULE
  • Woodward 8273-101 Rev: A - 2301D Digital Load Sharing and Speed Control
  • WOODWARD 8272-799 - 2301A SPEED CONTROL WITH REMOTE REFERENCE REV:C
  • Woodward 8272-517 - PM Motor Control
  • Woodward 8290-048 8290048 Rev. F - Generator Load Sensor
  • woodward 8273-1012 rev c - 2301e Load Sharing and Speed Control
  • WOODWARD 9905-797 - DIGITAL SYNCHRONIZER AND LOAD CONTROL FOR 3 PHASE GENERATORS
  • WOODWARD 8280-3014 - 723 PLUS DIGITAL CONTROL REV NEW
  • WOODWARD 8440-1884 REV G - GENSET CONTROLLER EASYGEN-2500-5/P1
  • Woodward 8272-683 K - Digital Reference
  • WOODWARD 9907-014 - SPEED CONTROL 2301A REV H
  • Woodward Type UG-8 P/N 037260 - Governor R.P.M 1075-1650 Motor KM58-20
  • WOODWARD 9905-970 - LINKNET 6 CHANNEL 100 OHM RTD Rev:J
  • Woodward 9907-1183 Rev C - Steam Turbine Digital SCREEN 505E Turbine Control
  • Woodward 8440-1614 - GCP-30 Genset Control Package, Rev: F, Type 1, E231544
  • Woodward DC11006-304-024 - ACTUOTOR DYNA ACTUATOR - BARBER-COLMAN
  • Woodward 9905-971 - LINKNET 6 CHANNEL 100 OHM RTD Rev:K
  • Woodward DYNK-10249 - Actuator Controller Kit - DYNA 2000
  • Woodward LR21035 - MFR1 MULTI FUNCTION RELAY REV F
  • Woodward 8440-1831 - EASYGEN 3200-5 P/N: REV. G Gererator Controller
  • Woodward 8272-516 - PM MOTOR CONTROL REV J
  • Woodward 8440-2080 - EASYGEN 2000 genset controller EASYGEN-2300-5/P1
  • Woodward 505DE - Digital Control System
  • Woodward 701 - Digital Speed Control 18-40 VDC 4-20 MA
  • Woodward 8440-1799 - EASYGEN-350 REV B
  • Woodward 8272-582 - Apm Motor Control 100-220v AC/DC
  • Woodward 5501-031 D - 3077-474C 8605895 Circuit Module
  • Woodward XD1-T - XD1T55SAT TRANSFORMER DIFFERENTIAL PROTECTION RELAY
  • Woodward 8272-517 - PM Motor Control 220vac
  • Woodward 8934-658 - Repair Kit UG8D Governor
  • Woodward 5437 18 - module netcon derivative analog rev.A
  • Woodward 8272-171 A - Pm Motor Control
  • Woodward MRN3-1/2 - SEG mains uncoupling relay MRN314D mains decoupling relay
  • Woodward 9905-373 - Digital Synchronizer and Load Control 18-40 VDC Rev P
  • Woodward 5431-640 C - Dual Dynamics 1000 Series Speed Control Module
  • Woodward 5501-031 D - 3077-474C 8605895 Circuit Module
  • Woodward 9907-247 - 828 DIGITAL CONTROL
  • Woodward 8440-1855-G - EASYGEN-2200-5 /P1 12/24VDC GENSET CONTROLLER
  • Woodward NC3-2-8 (NO) - GENERATOR CONTROLLER
  • Woodward 8271-467 K - 2301 LOAD SHARING AND SPEED CONTROL PART NO:
  • Woodward 8440-2177 A - SPM-D2-10 Digital Synchronising Controller
  • Woodward LXMG1614E-14-11 - CCFL and UV Lamps Inverter Module
  • Woodward 8270-990 - signal converter
  • Woodward 9905-068 - LOW VOLTAGE 2301A LOAD SHARING & SPEED CONTOL P/N:
  • Woodward 8901-051 - BOOSTER SERVOMOTOR, SINGLE CYLINDER, 2:1
  • Woodward 8444-1024 D - MWS4-55M CONTROL MODULE UNIT
  • Woodward 5448-914 - GCP-20 Genset Control GCP-20 REV D P/n:
  • Danfoss BHA-1 018-1942 - Hydraulic Actuator
  • Woodward 9905-001 L - SPM-A SYNCHRONIZER
  • Woodward 5464-850 - Module
  • Woodward 5501-371 - Micronet Simplex Mpu Aio Rev C
  • Woodward 8272-132 B - POWER SENSOR
  • Woodward 9907-028 - SPM-A Synchronizer
  • Woodward SA-3678-AM-2 - Overspeed Electric Governor, Model ESSE2-AM
  • Woodward E8250-502 - GOVERNOR ACTUATOR
  • Woodward 8440-1884 J - Controller EASYGEN-2500-5
  • Woodward 5441-693 - DIGITAL I/O MODULE -MISSING PART
  • Woodward SA-4450 - Speed Controller APECS 3100 For Magnetic Pickup
  • Woodward 9903-466 - 701 DIGITAL SPEED CONTROL REV G
  • Woodward 1765-843 - Governor Speed Adjusting Motor P/N Type: SMM40 220V AC 50/60Hz
  • Woodward 9905-760 - Linknet Termination Module
  • Woodward 9907-247 - 828 DIGITAL CONTROL UNIT REV K
  • Woodward 5484-721 - motor
  • Woodward 8440-1734 - MFR-2 Rev.A Multi Function Relay MFR-2
  • Woodward CSC3SUWA - Controller
  • Woodward 8440-1667 - REV B SPM-D1010B/XN