K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

KUKA Robots KR QUANTEC-2 HC Assembly Instructions

From: | Author:Wang | Time :2026-09-15 | 200 visit: | 🔊 Click to read aloud ❚❚ ▶ | Share:

KUKA Robots KR QUANTEC-2 HC Assembly Instructions

HC = Health Care, Specialized heavy-duty robots for healthcare applications; Model: KR 300 R2700-2 HC, KR 300 R2700-2 HC II, rated load of 300   kg, maximum arm span of 2701   mm; only allowed for ground installation, base allows maximum ± 5 ° tilt; Ceiling and wall hanging are strictly prohibited; Adapt controllers KR C4-HC, KR C5-M6/M7. The main body is equipped with a liquid gas energy storage balance cylinder (pressure equipment) and a Patient Rescue exclusive system, aimed at automation scenarios in the medical industry. 

Product Description

Body structure: 6-axis serial robot; Components: In line hollow wrist, upper arm, connecting rod arm, rotating column, base frame, hydraulic pneumatic pressure balancing cylinder, Patient Rescue patient rescue system, complete set of micro RDC electrical components.

A1-A3 have mechanical hard stops for equipment protection purposes only; A2 Negative factory built-in mechanical limit; Personnel protection relies on the Safe Robot safety function of the controller.

Distinguishing between two major sub models

KR 300 R2700-2 HC: compatible with KR C4-HC and KR C5;

KR 300 R2700-2 HC II: Only compatible with KR   C5-M6/M7, cable specifications may vary.

Patient Rescue Patient Rescue System (exclusive to HC models): used for mobile robots in emergency situations during power outages, and for personnel rescue in medical settings; Composed of a storage box and an emergency stop handheld device; Open the storage box and trigger STOP 1 for safe shutdown of the robot; A1 (HC-II can release A1+A6) brake to achieve manual joint movement.

Installation of rigid constraints: Only for ground installation, maximum ± 5 ° inclination of the base, ceiling/wall mounting is prohibited; The balance cylinder structure only supports ground posture, and incorrect installation may cause the arm to fall and pose a risk of death.

Permitted use: Medical related handling and tooling operations; Environmental conditions must be met.

Prohibited misuse: Climbing and trampling, overloading, carrying people and animals, outdoors, explosion-proof, radioactive environment. Misuse will result in the loss of all warranty.

Wrist flange: ISO 9409-1, flange specifications, normal operation and emergency stop impact conditions flange force torque; Reserved additional load installation interface for column/boom.

Available options: brake manual release device, various flange adapters.


Technical Data

The KR 300 R2700-2 HC/HC-II models have the same mechanical body parameters, but differ in controller adaptation and cable specifications.

Public basic parameters

The self weight of the body is about 1150 kg; the rated load is 300 kg; the maximum arm span is 2701 mm; the repeat positioning accuracy is ± 0.05 mm; the working envelope is 53.9 m ³;

Protection level: IP65 for the entire machine and IP65 for the wrist; Noise level<75 dB (A); Base 754mm × 754mm;

Temperature: KR C4 operates at 5-35 ℃; KR C5 operates at 0-55 ℃; Storage -40~60 ℃;

Cable: KR   C4 maximum cable length 20   m; KR   C5 maximum 50   m; 16   mm ² equipotential grounding conductor;

Mastering angles: A1-25 °; A2-100 °; A3-100 °; A4 0°; A5 0°; A6   0 °.

Foundation load

Provide normal/peak operating conditions: vertical force Fv, horizontal force Fh, overturning moment Mk, A1 rotational moment Mr; additional loads on columns and connecting rod arms are not included in the foundation load and must be added to the foundation design; The minimum grade of concrete is C20/25.

Stop distance&stop time

Distinguish between STOP 0 (category 0 uncontrolled emergency stop) and STOP 1 (category 1 controlled shutdown);

Provide A1-A3 axes under KR C4 and KR C5 controllers, as well as stop angle and stop time curves for different POV program magnifications, extension lengths, and load masses;

STOP   0 will generate high load on the robot, so try to avoid frequent triggering as much as possible; Perform brake testing at least once a year.

Other

Wrist flange axial force, radial force, overturning torque (normal, emergency stop impact); Additional load installation dimension diagram; Instructions for the nameplate and warning label of the main body; REACH and RoHS compliance information.


Planning and Design

Provide 3 sets of ground installation plans, all for ground use only:

S780 with fixed base kit (part number 0000-327-118, approximately 58.5 kg): concrete foundation; Bottom plate, positioning pin, M24 bolt, chemical anchor bolt; Leveling mortar is allowed for uneven foundations, and it is strictly prohibited to pour mortar into bolt holes; Provide the dimensions of the foundation section and the distance between the edges of the steel bars.

150mm raised base S780 (part number 0000-338-338, approximately 261kg): Raise the robot body.

Rack direct installation kit (part number 0000-310-641, approximately 3.52 kg): Customer steel structure/slide table; Cylindrical pin+flat pin positioning, 8 M24 bolts are tightened diagonally in steps.

Cable and interface planning

The external interface at the rear of the A1 base of the main body includes motor cables, data cables, Patient Rescue patient rescue cables X25/XG25, balance cylinder system cables X26/XG26, teaching pendant cables, and grounding terminals.

Complete definition of KR C4 and KR C5 connector pins; Minimum bending radius; The equipotential must meet VDE0100 and EN   60204-1.

Special requirement: The operating location of the Patient Rescue system must ensure that the operator can access it on site.

Reminder: Continuous extreme working conditions (high temperature, high frequency start stop) require a shortened maintenance cycle and consultation with KUKA services is needed.

Transportation

Mandatory standard transportation posture (unified for all models): A1   0 °, A2-135 °, A3   150 °, A4   0 °, A5   105 °, A6   0 °; The transportation posture cannot be changed.

Transportation method

Forklift: Base fork slot, minimum load capacity of 2 tons, can be forked in both directions;

Crane lifting: Special lifting equipment part number 0000-342-903; Dismantle tools and pipeline packages to prevent center of gravity deviation.

Prohibit non certified suspension points; Provide the center of gravity coordinates of the entire machine; Avoid impact and vibration during transportation.


Startup and Re Debugging

Complete start-up process for three installation conditions: standard centering base, 150mm raised base, and rack steel structure installation.

General process: Place the lifting device in place → Clean the installation surface, install the positioning pin → Position the robot → Tighten the M24 bolts diagonally in multiple stages; Necessary grouting and leveling; Dismantle the transportation lifting equipment.

Wiring specifications

Grounding M8 nut torque 23 Nm;

The tightening torque of the motor cable is 3 Nm; the data cable buckle must be completely locked;

Patient Rescue rescue cable X25/XG25 and balance cylinder system cable X26/XG26 must be connected;

The wiring is completed and a complete equipotential conduction test is performed.

Special start-up steps: Exhaust the balance cylinder, move the A2 axis ± 30 ° to release the accumulated air inside, and prevent the protective cover from popping out and injuring people.

T1 mode low-speed whole machine trial operation; Complete cable pin allocation diagram.


Maintenance

Before maintenance of HC medical models, the equipment must be decontaminated and a hygiene status statement must be provided. Maintenance beyond the scope of the manual should be handed over to KUKA certified engineers.

Maintenance cycle benchmark

5000 hours or at the latest 1 year: lubrication of balance cylinder bearings; Pressure inspection of balance cylinder system; Functional testing of Patient Rescue rescue system;

20000 operating hours or 5 years, whichever comes first: replace all gearbox oil;

The balance cylinder must be replaced as a whole after 10 years (pressure components are mandatory).

consumables

Gearbox oil: Optigear Synt.   ALR   150; Lubricating grease LGEP   2 for balance cylinder bearings; The capacity manual table for each axis is provided.

Key points for oil change operation: The gearbox is in a hot working state; Ventilate and release pressure before draining oil to prevent scalding caused by hot oil splashing; Magnetic plug specified torque; Flush the gearbox with less than 70% of the nominal capacity when draining oil; Rinse less than 50% multiple times; Oil change completed T1 low-speed running in, check the seal for no leakage.

Maintain project list

Drain oil, rinse, and add oil to each axle gearbox;

Balance cylinder: pressure detection, standard pressure 176 bar (± 5 bar) bar@20 ℃); Check the corrugated pipe and seal for leaks;

Complete functional testing of Patient Rescue rescue system;

Whole machine cleaning: only neutral water-soluble cleaning agents; High pressure steam jet cleaning is strictly prohibited;

Grounding circuit continuity test, grounding resistance limit ≤ 0.1   Ω.


Maintenance

Medical application equipment must be decontaminated before maintenance; To return spare parts to the warehouse, a repair card needs to be filled out.

General safety rules for motor replacement: disassembly of A2/A3/A5/A6 motors, mechanical locking of the suspension arm, and locking of the balance cylinder at the same time; Power off the brake and balance cylinder energy storage will cause the arm to fall and squeeze to death.

Motor replacement steps: Disassemble the connector; Remove the bolts; Apply Microlube GL261 lubricating grease to the involute spline of the new motor (excessive grease is prohibited from entering the brake); Replace all O-ring seals with new ones; Do not install the motor at an angle; Tighten the bolts diagonally in stages; Restore the connector.

Motor replacement completed: The axis must be master calibrated at zero point; T1 low-speed test.

In addition to the replacement of each axis motor, it also includes the replacement of additional brakes, inline hollow wrist assembly, transmission shaft, balance cylinder cable, and the disassembly and replacement of the entire Patient Rescue system.

Complete electrical schematic: motor, brake, temperature sensor, micro RDC encoder, balance cylinder pressure sensor, patient rescue circuit, all grounding circuits.

High voltage safety 5-step procedure: power-off, locking to prevent restart, electrical inspection, grounding short circuit, isolating adjacent live parts.


Shutdown, Storage, and Scrap Disposal

Dismantling process: The robot moves to the standard transport posture; Emergency stop, lock and power off; Dismantling tools and fixtures; Disconnect the cables (including Patient Rescue and balance cylinder cables) and ground them; Loosen the M24 bolt on the base, lift it vertically, and protect the positioning pin.

Storage conditions: dry and dust-free, avoiding condensation, -40~60 ℃; Clean and cover the body, remove tool accessories, seal electrical connectors, and place desiccants if necessary.

Scrap and dismantle

Classification and recycling of cast aluminum, cast steel, steel, copper cables, and electrical components; Used gear oil as hazardous waste;

Before disassembling the balance cylinder, it must be completely depressurized. There is a risk of explosion if the internal high-pressure nitrogen gas is not depressurized;

Complete decontamination and disinfection and sterilization before scrapping medical application equipment.


Options: Brake Manual Release Device

Purpose: Manual movement of joints in case of power failure, limited to emergency rescue only;

After using the release device to move the joint, all axes must be recalibrated and the brake must be fully functional tested to prevent injury from collision.

  • GE 369B1860G0026 MPU50 Nexus Controller
  • GE IS420ESWBH3A Industrial ESWB Ethernet Switch
  • GE IS420ESWBH2A Mark VIe IONet Network Switch
  • GE IS200SRTDH2ACB RTD Terminal Board Mark VI
  • GE SR469-P5-HI-A20 Motor Protection Relay
  • GE VMIVME-7750 Pentium III VME CPU Module
  • GE IS215UCVEH2AE VMIVME-7614-132 VME Controller Card
  • GE MVDL800-47931101-A Liquid-Cooled Delta Module for MV3000 Medium Voltage Drive Systems
  • ABB BRC410 SPBRC410 Harmony Bridge Controller
  • ABB PFCL201CE-50kN 3BSE006699D0005 Pressductor PillowBlock Load Cell
  • ABB 5SHY3545L0009 3BHB013085R0001 IGCT Module
  • Wika IPT10 - Process Pressure Transmitter
  • Omron SK20-C1DT-D - Programmable Controller PLC Unit
  • Foxboro Eckardt (Schneider) AE214 - Field Indicator Digital Display Meter
  • Omron CJ1W-OD232 - Transistor Output Unit PLC Module
  • Jetter JX2-IO16 - Digital Input Output Module PLC
  • SEFI ACS 48.6A-NS - Power Supply Unit
  • Schneider (Telemecanique) XBTF011110 - Magelis Membrane Keyboard Overlay
  • Siemens 6ES5246-4UA41 - Simatic S5 Positioning Module
  • Siemens 6SL3120-2TE13-0AA3 - Sinamics S120 Dual Motor Module Inverter
  • SEW Eurodrive MAS51A005-503-50 - Movidyn Servo Drive Controller
  • Record ATE 20 - Automatic Door Brake Motor
  • Record ATE STA 21 - Automatic Door Brake Motor
  • Sanyo Denki R2AA06040FXP02 - AC Servo Motor
  • Omron NX-ID4442 - DC Digital Input Unit PLC Module
  • Schneider (Telemecanique) XBTGT2330 - Magelis Advanced Touch Panel HMI
  • ABB DX561-A1 - AC500 Digital Input Output PLC Module
  • SEW Eurodrive MC07B0004-2A3-4-00 - Movitrac B AC Frequency Inverter Drive
  • Schneider (Telemecanique) FT20CBCL030 - Connection Communication Cable
  • Visions AXFR 600601 - Gap Control Side Board PCBA
  • Allen Bradley 1797-CEC-A-C01 - Flex Ex Communication Interface Adapter
  • Siemens 6ES5095-8MC03 - Simatic S5 Programmable Controller CPU
  • Tectrol / Pitney Bowes TC53S-1392 - Power Supply Unit
  • Bronkhorst P-702C-FAC-88-Z - Digital Mass Flow Controller
  • Allen Bradley 1757-SRM - ControlLogix Redundancy Module
  • Neste 0635-107 - Control Board for SLX Automatic Sliding Door
  • RSF Elektronik MS 2x.x4 MO - Linear Encoder Sensor
  • Pro-face GP37W2-BG41-24V - Graphic Terminal Operator Panel HMI
  • Allen Bradley 2711P-RP1 - PanelView Plus Logic Module HMI
  • ABB (Asea Brown Boveri) GNT0144700R0004 - Power Supply Electronic Board Module
  • SEW Eurodrive MC-LTE-B-0008-2B1-1-40 - Movitrac LTE AC Frequency Inverter Drive
  • Siemens 3RK1301-0AB10-0AA4 - Direct Starter Modular Motor Starter
  • Yaskawa SGDB-15VD - Servopack Servo Drive Amplifier
  • National Instruments NI 9421 - 8-Channel C Series Digital Input Module
  • Yaskawa SGDB-10VD - Servopack Servo Drive Amplifier
  • National Instruments NI 9476 - 32-Channel C Series Source Digital Output Module
  • Pitney Bowes R782000 - Turbojet Controller Board PCBA
  • Lika IT65-Y-1000BND2 - Incremental Encoder Sensor
  • Came 002ZT6 - Control Panel Board for Gear Motors
  • Desin HS-300/7500 - Multivariable Process Controller Unit
  • Pilz PNOZ mc1p - Modular Safety Relay Controller
  • Innovative Robotics PTNR2-2-NES - Controller Interface Board Module
  • Schneider Electric (Telemecanique) TSXCB4020 - Printer Communication Link Cable
  • Wika IPT10 - Process Pressure Transmitter
  • Schneider Electric (Modicon) TSXDMF342A - Extension Digital Analog Module for TSX17 PLC
  • Omron F150-KP - Vision System Cursor Key Pack Console
  • National Instruments BNC-2110 - Shielded Connector Block Accessory
  • Bosch Rexroth (Indramat) CSH01.2C-SE-EN2-EN2-CCD-NN-S-FW - Servo Drive Control Panel Interface Module
  • GHM / Gefran / Baumer GHM510573A/1000 - Incremental Encoder Sensor
  • National Instruments NI 9425 - 32-Channel C Series Digital Input Module
  • Schneider (Telemecanique) STBDDO3705 - Digital Output Module STB
  • Siemens 6EP1436-1SH01 - Regulated Power Supply Unit
  • Schneider Electric (Modicon) TSXFPP20 - Fipway PCMCIA Communication Board
  • April QMB 3202 - PLC Output Card Module with Parameter Surveillance
  • Siemens 6ES5240-1AA12 - Simatic S5 Communication Processor Module
  • Midi Engineering MI907A - Stepper Motor Midi Amplifier Driver
  • Schneider Electric (Telemecanique) TSXAEZ414 - TSX Series Analog Input Module
  • Schneider (Telemecanique) TSX17-20 - TSX17 Compact PLC Controller Unit
  • Siemens 6ES5955-3LC14 - Simatic S5 Modular Power Supply Unit
  • Schneider (Telemecanique) ATV66U72N4 - Altivar 66 AC Frequency Inverter Drive
  • Omron NX-OD4256 - Transistor Output Unit PLC Module
  • Yaskawa / Omron SGDH-04AE-OY - Sigma II Servo Drive 400W
  • RSF Elektronik MS 20.04-2M - Linear Encoder Scale Sensor
  • ITT GMW (Metrosx) DAA288-240 A - LED Message Display Board
  • Allen Bradley 1757-SRM - ControlLogix Redundancy Module
  • Sensorex Alpha-LSE - Display Inclinometer Indicator
  • Omron NX-DA3603 - Analog Output Unit PLC Module
  • Grundig Electronic NRP 02 - Power Supply Control Unit Module
  • ProSoft Technology RLX-FHES-F - RadioLinx Industrial Wireless Hotspot Router
  • Omron NX-EIC202 - EtherCAT Coupler Unit PLC Module
  • Omron NX-TS3201 - Temperature Sensor Input Unit PLC Module
  • Omron CQM1-CPU41-V1 - Sysmac CQM1 PLC CPU System
  • April CPU5001 - PLC CPU Processing Unit
  • Yaskawa JZDP-D008-020-E - Linear Servo Motor Actuator
  • Bronkhorst P-702C-FAC-88-Z - Digital Mass Flow Controller
  • Allen Bradley 2711-K3A17L - PanelView 300 Operator Terminal HMI
  • Schneider (Telemecanique) TSXAEM411 - TSX Series Analog Input Module
  • Schneider Electric (Telemecanique) XBTGT5330 - Magelis Advanced Touch Panel HMI
  • Siemens 6ES5928-3UA12 - Simatic S5 Central Processing Unit PLC
  • Schneider (Telemecanique) TSXSUP65 - Power Supply Module
  • Schneider (Telemecanique) TSXLES61 + TSXLES60 - TSX Series Fine Line Box Local Module
  • Siemens 6SE6440-2AD23-0BA1 - Micromaster 440 AC Frequency Inverter Drive
  • National Instruments NI 9205 - 32-Channel C Series Analog Input Module
  • Yaskawa CIMR-PCC42P2 - Varispeed AC Frequency Inverter Drive
  • ABB PM554-T-A1 - AC500 PLC CPU Module
  • National Instruments cDAQ-9178 - 8-Slot CompactDAQ USB Chassis Backplane
  • Allen Bradley 1786-RPA - ControlNet Repeater Adapter Module
  • Allen Bradley 1770-KFD - DH-485 Communication Interface Module
  • Grundig Electronic NSP 02 - Power Supply Control Unit Module
  • Teq Q07.K3S.002A - Control Panel Logic Board
  • Allen Bradley 1300-ITSSC - Signal Converter Interface Module
  • Omron CQM1H-CPU51 - CQM1H Modular PLC System
  • ProSoft Technology 4207-DFNT-MCM - ProLinx Industrial Gateway Module
  • Schneider Electric TSXSCP114 - RS485 PCMCIA Communication Board
  • Grundig NGE 01 - Power Supply Unit
  • Grundig NZP 03 - Power Supply Unit
  • Siemens 6ES5246-4UA41 - Simatic S5 Positioning Module
  • Danaher / Atlas Copco / Socapel SAM-PA-400-30-E - Servo Power Supply Controller Unit
  • Klöckner Moeller EM4-101-DD1 - Easy Control Relay Module
  • Bosch Rexroth DKC-10.3-012-3-MGP-01VRS - Indramat Digital Servo Controller Drive
  • Schneider (Telemecanique) XBTGT2110 - Magelis Touch Panel HMI with Cutter
  • Berger Lahr (Sig Positec) WD3-004.1802 - Stepper Motor Controller Driver
  • ProSoft Technology MVI56-WA-EIP - ControlLogix Wireless EtherNet/IP Communication Module
  • Allen Bradley 1794-ACNR15 - Flex I/O ControlNet Adapter Module
  • Fanuc A06B-6096-H201 - Servo Amplifier Module
  • Panasonic MSDA083A1 - AC Servo Driver Amplifier
  • Teq Q07.K3P.003B - Control Panel Logic Board
  • Schneider (Telemecanique) XBTH002010 - Magelis Operator Terminal HMI
  • Wika IPT10 - Process Pressure Transmitter
  • Teq Q07.A4P.001A - Control Panel I/O Module Board
  • Teq Q07.A3L.003A - Control Panel Module I/O Board
  • Siemens 6ES5246-4UA31 - Simatic S5 Positioning Module
  • Mitsubishi / Harmonic Drive HC-KFS43 - AC Servo Motor with Harmonic Reducer
  • Mitsubishi HC-KFS43 - AC Servo Motor
  • SES Store Electronic Systems 37120/120 - VLF Radio Transmitter Label System
  • Siemens 6SE9213-6BA40 - Micromaster AC Frequency Inverter Drive
  • Rosemount 1151DP5S22 - Differential Pressure Transmitter
  • Siemens 6FM1470-4AA20 - Simatic FM 470 Positioning Module Processor