Product overview
WOODWARD LSOV25 liquid fuel shut-off valve is a critical safety component designed specifically for industrial gas turbines and other equipment, playing an indispensable role in ensuring stable operation and safe production of the equipment. Its design aims to quickly cut off all liquid fuel flows, effectively preventing fuel leakage to the turbine, thereby avoiding potential safety hazards and equipment damage.
Product Structure and Working Principle
(1) Structural Design
Overall structure: LSOV25 belongs to a three-way, two-stage valve structure. The valve body is made of anodized aluminum material, which not only has good corrosion resistance and can adapt to various complex working environments, but also has a relatively light weight, making it easy to install and maintain. All internal moving parts are made of hardened stainless steel to ensure high wear resistance and reliability during long-term and frequent operation, reducing the probability of failure caused by component wear.
Key component: The valve is equipped with a flushing flow filter inside, which can effectively block pollutants with a particle size exceeding 40 μ m (nominal), prevent them from entering the pilot valve section, avoid damage to the pilot valve, and ensure the normal operation of the entire valve. At the same time, the setting of the filter screen will not have a significant filtering effect on the normal fuel flow, ensuring that the fuel can pass smoothly through the valve.
(2) Working principle
Normal working state: In the normal working state when powered on, the valve remains open, and fuel can flow in normally from the inlet and be delivered to the corresponding position according to the equipment operation requirements, meeting the continuous supply of fuel for gas turbines and other equipment.
Cut off working mechanism: When the current of the solenoid valve terminates, the valve will quickly respond. This valve utilizes supply pressure to achieve complete cut-off of fuel flow and can complete this operation in 0.09 seconds or less. The closing process of the valve is completed by the combined action of spring compression and auxiliary supply pressure. At the moment of power outage, the spring quickly releases its elastic force and cooperates with the supply pressure to push the relevant components to move, quickly cutting off the fuel passage and bypassing all fuel entering the valve to the return system, effectively preventing the fuel from continuing to flow to the turbine and avoiding possible dangerous situations such as turbine overspeed and abnormal combustion caused by fuel loss of control.
Product specifications
Voltage configuration: To meet the electrical requirements of different devices and systems, this valve offers four voltage configuration options, namely nominal voltage of 24 Vdc, 125 Vdc, and also available in 115 Vac or 220 Vac versions. Users can flexibly adapt according to the power type of the actual usage scenario.
Pressure parameters: During normal operation, the valve is designed to withstand a maximum supply pressure of up to 1200 PSI (8274 kPa), which can meet the working requirements of high-pressure fuel delivery systems. Its designed pressure resistance is stronger, capable of withstanding a verification pressure of 1800 PSI (12 411 kPa) and a burst pressure of 6000 PSI (41 370 kPa). Even under extreme pressure conditions, it can ensure the structural integrity of the valve and prevent serious failures such as rupture.
Flow parameters: Based on MIL-C-7024 calibration fluid from the United States, tested at 70 ° F (21 ° C), the rated flow rate of the valve is 30000 lb/h (13600 kg/h), which can meet the basic requirements of fuel flow for most industrial gas turbines under different operating conditions.
Fuel compatibility: This valve has excellent fuel compatibility and can be used with almost all common fuels, including diesel, methanol, ethanol, Jet "A" aviation kerosene, regular kerosene, # 2 household heating oil, heated light crude oil, and residual fuel. Moreover, within the prescribed pollution limits, the valve can operate normally, ensuring stable operation even if the fuel contains a certain amount of pollutants.
Temperature range: The valve can adapt to a fuel temperature range of 0 to+250 ° F (-18 to+121 ° C), and can operate normally under a wide range of temperature conditions, meeting the fuel control needs of different seasons and working environments.
Cycle life: After rigorous testing and practical application verification, the cycle life of this valve can reach 10000 times, with high durability, reducing the cost and maintenance workload caused by frequent valve replacement.
PRODUCT FUNCTION
Quick cut-off function: It can cut off fuel supply in a very short time (0.09 seconds or less), ensuring that in emergency situations such as equipment failure, control system issuing shutdown commands, or detecting abnormal conditions, the delivery of fuel to the turbine can be quickly stopped, effectively preventing accidents from occurring or expanding.
Fault safety function: The valve design follows the principle of fault safety. Once the electrical signal is lost or terminated, the valve will automatically bypass all incoming fuel to the return system, ensuring that the system is in a safe state. This design greatly improves the safety and reliability of equipment operation, reducing the risk of fuel loss due to electrical faults.
Protection function: mainly used to protect the turbine in the event of normal fuel control failure for any reason. If the valve cannot cut off the fuel supply to the turbine normally, it may cause serious overspeed problems, leading to mechanical damage and even personal injury. Therefore, the LSOV25 liquid fuel cut-off valve is an important line of defense to ensure the safe operation of equipment such as gas turbines.
Product advantages
High reliability: Using high-quality anodized aluminum shell and hardened stainless steel internal components, combined with advanced design and manufacturing processes, the valve has excellent durability and fatigue resistance, and can operate stably in harsh industrial environments for a long time, reducing equipment failure and maintenance frequency.
Rapid response: The fuel cut-off action can be completed within 0.09 seconds. This rapid response capability can respond to various emergency situations in a timely manner, effectively reducing potential risks caused by fuel loss of control and ensuring the safety of equipment and personnel.
Wide fuel adaptability: Compatible with various types of fuels, whether it is common diesel, kerosene, or some special fuels, it can work normally under specified conditions without the need to customize valves separately for different fuel types, improving the product's versatility and application range.
Complete safety design: Fault safety function and quick cut-off mechanism provide safety guarantee for equipment operation from multiple aspects, comply with strict industrial safety standards, and make users feel more at ease during use.
Application scenarios
In the field of power generation: In gas turbine power plants, the LSOV25 liquid fuel cut-off valve is a key component to ensure the safe operation of power generation equipment. When the generator set malfunctions, such as control system failure, abnormal turbine vibration, or overheating, the valve can quickly cut off the fuel supply, avoiding more serious accidents and ensuring the stability and continuity of power supply.
Industrial drive equipment: For gas turbines that drive industrial machinery such as compressors and pumps, LSOV25 valves also play an important role. During the operation of the equipment, if unexpected situations arise, such as mechanical component damage that may affect the normal control of fuel supply, valves can promptly cut off the fuel to prevent further damage to the equipment and protect the safety and stability of the entire industrial production process.
Marine ship power system: In the gas turbine power system of marine ships, due to the complex and ever-changing marine environment, the equipment requires extremely high safety and reliability. The LSOV25 liquid fuel cut-off valve can quickly cut off fuel in emergency situations such as severe sea conditions and equipment failures, ensuring the safety of the ship's power system, avoiding fire, explosion and other hazards caused by fuel leakage or loss of control, and ensuring the safety of ship navigation.