Main characteristics
Multiple given inputs
Differential voltage input: ± 10 V;
Current input: 4-20 mA;
4 groups can call the given value input w1~w4 (± 10 V);
Internal signal inversion can be achieved through 24V digital input or jumper J1 on the board.
Slope (acceleration/deceleration) generator
T1 version: 1 set of slopes; T5 version: 5 sets of ramp times can be externally called;
Support quadrant recognition to select slopes; Jumper J3 can enlarge the slope as a whole by 10 times, with two ranges: 20 ms~5 s/0.2 s~50 s; J2 can close the slope (<2 ms);
Support external potentiometer to extend ramp time; Automatically cut internal preset values when disconnected.
Curve correction function: The positive and negative directions can independently set the step level S+/S - and maximum amplitude G+/G -; Zero crossing remains linear without any step.
Enable input: Only when the enable is valid, will the power level output. Given that it is generated through a ramp, it avoids valve step opening.
Status signal: "Ready for operation" ready to run output;
T5 version specific: switchable measurement point selection switch, multi-channel signal output measurement socket;
Reverse polarity protection of power supply; Onboard DC/DC power supply, no lifting zero point.
Model coding rules VT-VRPA2-XX-1X/V0/XX/*
Meaning of the paragraph
VT-VRPA2 product: Proportional valve amplifier board
Paragraph 2: 1=Adaptation to 4WRE6-2X; 2=Suitable for 4WRE10-2X
1X component series 1X (10-19 series, pin electrical unchanged)
V0 Standard Version
Option T1: 1 Road Slope; T5:5 Slope+Measurement Point Switch
*Additional Text Remarks
Supporting accessories: VT 3002-1-2X/48F open Euro card bracket (refer to manual 29928); Connector DIN 41612 48 pin F-type male head.
Internal functional logic
Power supply unit [1]: equipped with current limiting DC-DC to generate all internal positive and negative power supply.
Given summation [6]: Internal given=differential input+current input+call given w1-w4+zero offset Zw potentiometer.
Signal -100% 0%+100% flow direction
4-20 mA current 4 mA 12 mA 20 mA P-A/B-T
Differential voltage -10 V 0 V+10 V P-B/A-T
When the current input is disconnected/not connected, set it to 0% automatically; Voltage and current inputs take effect simultaneously, and a superposition operation is performed.
Given call logic [4]: four sets of given values from w1 to w4, external+10V/-10V or external potentiometer setting; Multiple signals are triggered simultaneously, with w4 having the highest priority and w1 having the lowest priority; The activation channel is indicated by a yellow LED on the panel.
Given inversion [7]: J1 jumper or external 24V signal is used to invert the polarity of the internal given after summation, and the panel LED "-1" indicates the inversion status.
Enable [8]: 24V digital input; Not enabled, power output stage turned off; Enable connection, given entry into the ramp generator.
Slope generator [9]: Limit the given rate of change; The step and amplitude limiting modules will not change the duration of the slope. Slope Voltage Comparison Table:
Measure socket voltage 5V 3V 2V 1V 0.5V 0.3V 0.2V 0.1V 0.05V 0.03V 0.02V
Time ms (J3 disconnected) 20 33 50 100 200 333 500 1000 2000 3333 5000
J3 closed, all times multiplied by 10.
Characteristic curve generation [11]: S+/S-step level, G+/G-amplitude limiting; Maintain linearity at zero crossing.
Amplitude limit [12]: The maximum limit given internally is approximately ± 110% of the rated value.
Oscillator [14]: provides excitation for the valve's built-in inductive position sensor; The demodulator [15] reads the actual position signal of the valve core (100% corresponds to 10 V).
Position controller [17]: Optimize closed-loop position adjustment for the corresponding valve model.
Power output stage [18]: outputs approximately 5 kHz clock driven electromagnet; Single channel electromagnetic current limiting 2.5~2.8 A; output short-circuit protection; Output power failure when faulty or not enabled.
Fault identification [19]: Monitoring position sensor primary side disconnection or short circuit; Power output overcurrent; Cut off power output in case of malfunction, Ready output becomes low level.
The difference between T1 and T5 block diagrams: T5 supports four quadrant recognition to call slopes and adds a measurement point selection switch module [20]. The measurement switch of T5 can be selected to measure: internal given w1‑w4、 There are a total of 15 internal signals, including zero offset, ramp output, and time signals for each ramp.

Key electrical technical parameters
Project parameters
Power supply UB 24 VDC, allowing 18-35 V, power consumption<24 VA, current<2 A; 2A delay, replaceable fuse
Simulate given input w1-w4: ± 10 V,>100 k Ω; differential input: ± 10 V,>50 k Ω; current 4-20 mA, 100 Ω load
Digital input enable, reverse, given call, ramp call (T5); Above 8.5V ON, 0-6.5V OFF; Input impedance>100k Ω
Adjustable potentiometer Zw zero point; W1-w4 given; S+/S step (0-50%); G+/G amplitude (0-110%); T Slope time
Slope time 20 ms -5 s; jumper J3 switching x 10 times → 0.2-50 s
Power output electromagnetic clock 5 kHz, maximum single channel 2.5-2.8 A, short circuit protection
Auxiliary output ± 10V reference power supply 25 mA (short circuit protection); Actual value output ± 10 V; Ready output>16V is normal, fault<1V
Connector DIN41612-F 48 pin male head
Physical specifications Euro card: 100 × 160 mm; weight 0.17 kg
Temperature working range: 0~+50 ℃; Storage -25~+85 ℃
Board jumper, potentiometer, LED (T1/T5 versions)
Jumpers Function
J1: Reverse the polarity of the given signal;
J2: Slope switch; Close=Close the slope (<2 ms);
J3: Slope ratio; Open=20 ms -5 s; Close=x 10 times (0.2-50 s);
J4: Step function switch;
J5/J6/J7 are reserved with no functionality.
Panel potentiometer
Zw: Zero offset;
W1-w4:4 calls given;
S+/S ---: positive and negative step levels;
G+/G ---: Positive and negative amplitude limiting;
T (T1)/t1-t5 (T5) ramp time;
Unauthorized adjustment of the sealed potentiometer will result in loss of product warranty.
LED indicator light
Green: Ready for operation
Yellow: Enable
-1 "LED: reverse indication for given signal;
W1-w4 yellow LED: displays the current activated call for the given channel.
Measuring sockets
T1: Three measuring terminals x, w, t+measuring ground ⊥;
T5: Add a measurement selection knob switch and v measurement terminal, which can switch more than ten internal signal voltage observations.
Mechanical dimensions
Standard Eurocard specifications: 3HE height, 4TE width; Board body 100 × 160 mm; total length including connectors 182 mm; hole opening and installation compatible with DIN 41494 chassis; VT 3002-1-2X/48F bracket can be selected.