K-WANG



Product positioning and safety certification
SNO 4062 K/KM is a basic dual channel safety relay used for emergency stop and protective door monitoring, which meets the highest level of certification as follows:
EN ISO 13849-1:PL e、Category 4
DIN EN 62061:SILCL 3
DIN EN 60204-1:Stop Category 0
Model differentiation
Model Core Function Applicable Scenarios
SNO 4062 K synchronous monitoring, no input debounce emergency stop button, safety door, grating OSSD
SNO 4062 KM without synchronous monitoring, input stabilization, safety carpet dedicated to safety carpet, safety edge, safety corner
Core functions
Channel Mode
Single channel: Two channels in parallel
Dual channel: independent monitoring of two channels
Startup method
Manual start: Reset triggered by the falling edge of S32/rising edge of S35
Auto start: S35 and S33 are short circuited, and the rising edge of the safety signal automatically starts
monitoring function
Cross short circuit detection: CH1 connected to positive and CH2 connected to negative to identify a short circuit in the circuit
External contactor feedback: monitoring the status of the main contactor
Synchronous monitoring (K only): CH1 must close before CH2, with a synchronization time of tS ≈ 200ms
Input debounce (KM only): Filter short-term triggers to prevent frequent start stop
Signal compatibility
Supports grating OSSD signals (DIN EN 61496-1)
Support 4-wire safety carpet (DIN EN 1760-1, KM only)

Electrical and mechanical parameters
power supply
Rated voltage: AC/DC 24V
Power consumption: DC 2.0W, AC 2.4W/4.4VA
Output (forced guidance relay)
Safety enable: 2-channel NO, maximum 6A/240VAC, 5A/24VDC
Signal circuit: 1 NC channel
Disconnecting time:<25ms
Environment and Installation
Working temperature: -25~+55 ℃
Protection level: shell IP40, terminal IP20
Weight: 0.21kg
Wiring: Spring terminal, wire diameter 0.14-2.5mm ²
Typical applications
Dual channel emergency stop monitoring (with cross short circuit detection)
Sliding safety door monitoring (with synchronous monitoring)
Grating OSSD signal processing
Safety carpet/safety edge monitoring (KM only)
Model and Order Number
Model, wiring method, order number
SNO 4062 K fixed spring terminal R1.188.0699.2
SNO 4062 K-A pluggable connector R1.188.0709.2
SNO 4062 KM fixed spring terminal R1.188.0719.2
SNO 4062 KM-A pluggable connector R1.188.0729.2
Key issues
Question 1: What is the core functional difference between SNO 4062 K and KM? What devices are applicable to each?
answer:
K version: equipped with synchronous monitoring (tS ≈ 200ms), no input jitter reduction; Suitable for emergency stop buttons, safety doors, and light barriers.
KM version: No synchronous monitoring, but with input stabilization, specifically designed for high-frequency micro motion signal scenarios such as safety carpets and safety edge touches.
Question 2: What is the highest security level achieved by the device? Which standards do these levels correspond to?
answer:
PL e/Category 4: Corresponding to EN ISO 13849-1 (highest level of functional safety)
SILCL 3: Corresponding to DIN EN 62061 (Safety Related Electrical Control Systems)
Stop Category 0: Corresponding to DIN EN 60204-1 (Immediate power off and shutdown)
Question 3: What is the function of cross short circuit detection? How to achieve it?
answer:
Function: To detect short circuit faults between input lines and avoid undetected safety signal failures.
Implementation: Channel CH1 is connected to the positive pole and CH2 is connected to the negative pole. Once the line is short circuited, it will be immediately identified and the safety output will be cut off.

KONG JIANG
Add: Jimei North Road, Jimei District, Xiamen, Fujian, China