K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

Okonite Type SP-OS ITC/PLTC Instrument Cable

From: | Author:Wang | Time :2025-09-08 | 428 visit: | 🔊 Click to read aloud ❚❚ | Share:

Okonite Type SP-OS ITC/PLTC Instrument Cable

Product basic positioning

Okonite Type SP-OS cable belongs to the ITC/PLTC (Instrument Tray Cable/Power Limiting Tray Cable) category, with multi shielded pairs or three wire group structure and overall shielding design, rated voltage of 300 volts, temperature tolerance level of 105 ° C, designed specifically for cable tray scenarios, and meets multiple industry standards, suitable for electrical environments with high requirements for shielding and anti-interference.


Core specification parameters

(1) Conductors and Insulation

Category specific parameters

The conductor material is bare soft annealed copper, which meets the ASTM B-8 standard and adopts a 7-strand concentric structure; The communication cable is a 22 AWG solid bare copper wire with a 12 mil flame-retardant Okoseal insulation layer ® (PVC), Tolerant to 105 ° C

Insulation using flame retardant Okoseal ® (PVC) material, compliant with UL 13 and UL 2250 standards, nominal thickness of 15 mil, temperature rating of 105 ° C; X-Olene is recommended for special scenarios (DC applications in humid environments) ®  insulation

The conductor identification lines are colored in black and white; The three line group consists of black, red, and white; White conductor with numbers printed on it, used for group identification

(2) Shielding structure

Group shielding: Using aluminum/polyester tape overlapping wrapping to achieve 100% coverage, equipped with 7-strand tinned copper lead wires (two sizes smaller than conductors), and all group shields are completely isolated from each other to prevent crosstalk or capacitive coupling between adjacent wire pairs (especially for AC signals and pulse signals).

Cable overall shielding: Aluminum/polyester tape is also used to overlap and wrap to achieve 100% coverage. The drainage wire is made of 7-strand tinned copper with the same size as the conductor, which can isolate most of the static interference generated by the radiated electric field of power cables and other electrical equipment.

(3) Assembly and Sheath

Assembly method: Assemble wire pairs or three wire groups in a left twisted manner; If necessary, add flame-retardant and non absorbent fillers to ensure that the cable has a circular structure.

Sheath: Black flame retardant low-temperature Okoseal ®  Materials that comply with UL 13 and UL 2250 standards; A tear rope is longitudinally laid under the sheath for easy peeling.

(4) Electrical performance

Specific values of electrical indicators (different specifications)

Conductor resistance (20 ° C, per 1000 feet) 20 AWG: 10.4 ohms; 18 AWG: 6.5 ohms; 16 AWG: 4.1 ohms

Insulation test voltage (spark test) 5000 volts AC

Dielectric test voltage 1500 volts AC, lasting for 15 seconds

Insulation resistance constant (60 ° F, minimum value, typical value for natural materials) 2000 megaohms -1000 feet

Loop resistance (2 conductors, 20 ° C, every 1000 feet) 20 AWG: 2.8 ohms; 18 AWG: 13.0 ohms; 16 AWG: 8.2 ohms

Mutual capacitance (typical value, picofarads per foot) 20 AWG: 59; 18 AWG:68; 16 AWG:76

(5) Classification and Compliance

Obtained UL certification, listed as ITC/PLTC cable, can be used in accordance with Article 335 and Article 722 of the 2023 National Electrical Code.

Compliant with UL 2250 (ITC standard), UL 13 (PLTC, CL2, CL3 standard); It can also be used as a power limited fire-resistant signal cable (FPL) that complies with NEC Article 760 and is certified by OSHA.

Applicable scenarios

Circuit and Power Range: Suitable for ITC unclassified or non labeled circuits (voltage up to 150 volts, current up to 5 amps, power 750 volt amperes), as well as Class 2 or Class 3 power limiting circuits.

Environmental conditions: Can be used both indoors and outdoors; Adapt to humid or dry environments (maximum working temperature of conductors is 105 ° C, low temperature installation tolerance is -40 ° C); Can be used for cable trays, cable trays, scenes supported by overhead wires, and under raised floors.

Dangerous Area: Suitable for Class 1, Zone 2, Zone 2, and Zone 2 hazardous areas.

Functional requirement: It is necessary to shield external interference to the greatest extent possible, or to shield between wire groups (especially when cables may be subjected to abnormally high current or voltage interference); The cable has a built-in communication line that can be used for voice communication during installation or instrument calibration.


Product Features

Flame retardant performance: Passed UL 13 and IEEE 383-1974 vertical tray combustion tests.

Weather and chemical resistance: resistant to sunlight and oil, with excellent weather resistance.

Anti interference capability: 100% shielding coverage, reduces electromagnetic noise pickup, and has good external noise suppression effect.

Convenience of use: Strong flexibility, easy to operate and end connect; Complete isolation of wire pairs or three wire groups, precise shielding effect.


Other supplementary information

(1) Cable tray filling calculation

The cross-sectional area of the cable needs to be calculated according to NEC Article 392.22 to determine the reasonable filling amount of the cable tray.

(2) Length tolerance

When cutting lengths of 1000 feet or more, the tolerance is ± 10%.

When the cutting length is less than 1000 feet, the tolerance is ± 15%.


  • Woodward 9905-373 - Digital Synchronizer And Load Controller
  • WOODWARD MAGNETIC PICKUPS - Sensor
  • WOODWARD GCP-30 - Steuertafel for Industrial Regulator Genset Control Package
  • WOODWARD GOVERNOR 9907-1183 REV A - 505 ENHANCED TURBINE CONTROL
  • WOODWARD 9907-173 REV B - Module Load Sharing 120 Volt
  • WOODWARD 9907-014 - 2301A controller
  • Woodward 9905-029 - SPM-A Synchronizer Module Rev C
  • WOODWARD 8440-1799 EASYGEN-350 REV B - Genset Controller
  • WOODWARD 5466-258 REV M - SIMPLEX DISCRETE I/O MODULE
  • Woodward 8440-1884 C - Controller Easygen 2500-5
  • Woodward 8441-1153 - Monitoring Unit 250VAC
  • WOODWARD 8406-120 REV G - EGCP-2 DIGITAL CONTROL
  • Woodward 8273-584 - Atlas-ii Digital Control
  • Woodward 8272-582 - APM Motor Control 8272582
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8272-517 - Pm Motor Control
  • WOODWARD 9905-797 REV.B - DIGITAL SYNCHRONIZER AND LOAD CONTROL DSLC-D
  • WOODWARD 8272-582 - APM MOTOR CONTROL
  • Woodward Seg FP2-8-24 - Emergency Power Telecommunications Module NP2
  • WOODWARD 2001-12E2U1B1S1A - Fuel Shut Off Valve Stop Solenoid Valve 2000-4505
  • Woodward 8440-1884 K - Genset Controller Easygen-2500-5
  • Woodward 9905-760 - Linknet Termination Module
  • Woodward 8404-009 - Proact Digital Plus Front Panel Rev. H
  • Woodward 8271-651 - Digital Speed Reference
  • Woodward 3077-474C - 8605895 5501-031 D Circuit Module
  • WOODWARD 5466-257 REV.-C - NETCON 5000 MODEL REMOTE TRANSCEIVER I/O MODULE
  • Woodward 8273-101 Rev: A - 2301D Digital Load Sharing and Speed Control
  • WOODWARD 8272-799 - 2301A SPEED CONTROL WITH REMOTE REFERENCE REV:C
  • Woodward 8272-517 - PM Motor Control
  • Woodward 8290-048 8290048 Rev. F - Generator Load Sensor
  • woodward 8273-1012 rev c - 2301e Load Sharing and Speed Control
  • WOODWARD 9905-797 - DIGITAL SYNCHRONIZER AND LOAD CONTROL FOR 3 PHASE GENERATORS
  • WOODWARD 8280-3014 - 723 PLUS DIGITAL CONTROL REV NEW
  • WOODWARD 8440-1884 REV G - GENSET CONTROLLER EASYGEN-2500-5/P1
  • Woodward 8272-683 K - Digital Reference
  • WOODWARD 9907-014 - SPEED CONTROL 2301A REV H
  • Woodward Type UG-8 P/N 037260 - Governor R.P.M 1075-1650 Motor KM58-20
  • WOODWARD 9905-970 - LINKNET 6 CHANNEL 100 OHM RTD Rev:J
  • Woodward 9907-1183 Rev C - Steam Turbine Digital SCREEN 505E Turbine Control
  • Woodward 8440-1614 - GCP-30 Genset Control Package, Rev: F, Type 1, E231544
  • Woodward DC11006-304-024 - ACTUOTOR DYNA ACTUATOR - BARBER-COLMAN
  • Woodward 9905-971 - LINKNET 6 CHANNEL 100 OHM RTD Rev:K
  • Woodward DYNK-10249 - Actuator Controller Kit - DYNA 2000
  • Woodward LR21035 - MFR1 MULTI FUNCTION RELAY REV F
  • Woodward 8440-1831 - EASYGEN 3200-5 P/N: REV. G Gererator Controller
  • Woodward 8272-516 - PM MOTOR CONTROL REV J
  • Woodward 8440-2080 - EASYGEN 2000 genset controller EASYGEN-2300-5/P1
  • Woodward 505DE - Digital Control System
  • Woodward 701 - Digital Speed Control 18-40 VDC 4-20 MA
  • Woodward 8440-1799 - EASYGEN-350 REV B
  • Woodward 8272-582 - Apm Motor Control 100-220v AC/DC
  • Woodward 5501-031 D - 3077-474C 8605895 Circuit Module
  • Woodward XD1-T - XD1T55SAT TRANSFORMER DIFFERENTIAL PROTECTION RELAY
  • Woodward 8272-517 - PM Motor Control 220vac
  • Woodward 8934-658 - Repair Kit UG8D Governor
  • Woodward 5437 18 - module netcon derivative analog rev.A
  • Woodward 8272-171 A - Pm Motor Control
  • Woodward MRN3-1/2 - SEG mains uncoupling relay MRN314D mains decoupling relay
  • Woodward 9905-373 - Digital Synchronizer and Load Control 18-40 VDC Rev P
  • Woodward 5431-640 C - Dual Dynamics 1000 Series Speed Control Module
  • Woodward 5501-031 D - 3077-474C 8605895 Circuit Module
  • Woodward 9907-247 - 828 DIGITAL CONTROL
  • Woodward 8440-1855-G - EASYGEN-2200-5 /P1 12/24VDC GENSET CONTROLLER
  • Woodward NC3-2-8 (NO) - GENERATOR CONTROLLER
  • Woodward 8271-467 K - 2301 LOAD SHARING AND SPEED CONTROL PART NO:
  • Woodward 8440-2177 A - SPM-D2-10 Digital Synchronising Controller
  • Woodward LXMG1614E-14-11 - CCFL and UV Lamps Inverter Module
  • Woodward 8270-990 - signal converter
  • Woodward 9905-068 - LOW VOLTAGE 2301A LOAD SHARING & SPEED CONTOL P/N:
  • Woodward 8901-051 - BOOSTER SERVOMOTOR, SINGLE CYLINDER, 2:1
  • Woodward 8444-1024 D - MWS4-55M CONTROL MODULE UNIT
  • Woodward 5448-914 - GCP-20 Genset Control GCP-20 REV D P/n:
  • Danfoss BHA-1 018-1942 - Hydraulic Actuator
  • Woodward 9905-001 L - SPM-A SYNCHRONIZER
  • Woodward 5464-850 - Module
  • Woodward 5501-371 - Micronet Simplex Mpu Aio Rev C
  • Woodward 8272-132 B - POWER SENSOR
  • Woodward 9907-028 - SPM-A Synchronizer
  • Woodward SA-3678-AM-2 - Overspeed Electric Governor, Model ESSE2-AM
  • Woodward E8250-502 - GOVERNOR ACTUATOR
  • Woodward 8440-1884 J - Controller EASYGEN-2500-5
  • Woodward 5441-693 - DIGITAL I/O MODULE -MISSING PART
  • Woodward SA-4450 - Speed Controller APECS 3100 For Magnetic Pickup
  • Woodward 9903-466 - 701 DIGITAL SPEED CONTROL REV G
  • Woodward 1765-843 - Governor Speed Adjusting Motor P/N Type: SMM40 220V AC 50/60Hz
  • Woodward 9905-760 - Linknet Termination Module
  • Woodward 9907-247 - 828 DIGITAL CONTROL UNIT REV K
  • Woodward 5484-721 - motor
  • Woodward 8440-1734 - MFR-2 Rev.A Multi Function Relay MFR-2
  • Woodward CSC3SUWA - Controller
  • Woodward 8440-1667 - REV B SPM-D1010B/XN
  • Woodward 8406-120 - egcp-2 digital control
  • Woodward DPG-2201-002 - DIGITAL CONTROLLER REV D
  • Woodward 8272-516 - Pm Engine Control Rev J
  • Woodward 8440-1831 - EASYGEN 3200-5 P/N: REV. K - WITHOUT ACCESSORIES
  • Woodward 8273-101 - LOAD SHARING & SPEED CONTROL
  • Woodward 8440-1855-G - EASYGEN-2200-5 /P1 12/24VDC GENSET CONTROLLER
  • Woodward 9907-247 - 828 DIGITAL CONTROL UNIT REV K
  • Woodward LR21035 - MFR1 MULTI FUNCTION RELAY REV J
  • Woodward 8404-009 - PROACT DIGITAL PLUS FRONT PANEL REV J
  • Woodward 9905-204 - Rev N SPM-A synchronizer
  • Woodward 8521-367 - UG-8 P/N r R.P.M 750-1280 Governor / UG8
  • Woodward 9907-175 - Load Sharing Module Rev. B
  • Woodward 5464-645 - DRIVER MODULE REV A 2C ACT DRIVE
  • Woodward 8404-009 - PROACT DIGITAL PLUS FRONT PANEL REV J
  • Woodward 9907-175 - Load Sharing Module Rev. B
  • Woodward 8406-102 - Rev A EGCP-2 Digital Control Engine Generator 8406102
  • Woodward EASYGEN-2500-5 - Controller Genset
  • Woodward 8440-2082 - Controller
  • Woodward 8272-516 - PM MOTOR CONTROL REV J
  • Woodward 9905-373 - Digital Synchronizer and Load Control 18-40 VDC Rev P
  • Woodward 5501-429 - Actuator Controller 25mA 2 Channel , (UPP)
  • Woodward 8440-1869 - SPM-D10 Synchronizing System Control-SPM-D10B/PSY4-F-D
  • Woodward 9907-175 - Load Sharing Module Rev. A
  • Woodward 8200-224 - Servo Position Controller
  • Woodward 9906-619 - 723 PLUS DIGITAL CONTROL ( 8280-604 )
  • Woodward 8440-1519 - EASYGEN PART NO: REV: 4
  • Woodward 5501-371 - REV C MODULE- MICRONET SIMPLEX MPU & AIO FTM
  • Woodward EASYGEN-3200-5/P1 - Generator Controller Module Rev F
  • Woodward 8440-1884K - GENERATOR CONTROLLER EASYGEN-2500-5 REV,K
  • Woodward 5466-353 - REV C NETCON MAIN CHASSIS TRANSCEIVER
  • Woodward 9905-001 - SPM-A SYNCHRONIZER REV.L
  • Woodward 9907-838 - Speed control panel 9907-838 9907838
  • Woodward 9907-164 - 505 Digital Governor Turbine Control
  • Woodward 8273-465 - ATLAS W/O PC104 MODULE
  • Woodward 8200-1504 - Peak200 Steam Turbine Control Front Panel Mount HVAC Rev:E
  • Woodward 8272-582 - Apm Motor Control 100-220v AC/DC
  • Woodward 8440-1884 C - Controller Easygen 2500-5