Xycom Automation XT1502T Pro Face

Introduction

The XT1502 is a high performance 15.0” XGA (1024 x 768) TFT industrial flat panel monitors for use in NEMA 4 and NEMA 12 applications.  Graphics and text can be displayed on the monitor in up to 262,144 colors and in the modes listed below.  When the monitor is being driven in modes other than XGA, it will automatically expand the image and center it on the LCD. 

The unit is fully self-contained needing only to be panel mounted in an appropriate enclosure and connected to 120/240 VAC and a VGA source.  The monitor features a bright 200-nit LCD display and conveniently located front panel controls with on screen menus for easy set up and adjustment. The XT1502 is designed to provide tool free access for quick back light replacement and cleaning.  Both models are available with optional integrated analog resistive touch screens,  304 stainless steel bezels and 18-36 VDC input.

Installation of Monitor

This monitor is intended to be mounted in and used where NEMA 4 and NEMA 12 type enclosures are employed.  When mounted properly, the monitor meets or exceeds the sealing requirements set forth in the NEMA 4 and NEMA 12 specifications.   The monitor uses “U”-shaped clips and a special gasket to achieve the proper seal.To install the monitor, make a cutout per the diagram below in one of the walls of your NEMA enclosure.  Enclosures made of heavier gauge metal work better in that they won’t deform or bend as easily when the monitor’s sealing gasket is compressed.  Next hold the monitor in place while you install the mounting clips.  Tighten the clips in a cross pattern. This will help to develop an even pressure on the sealing gasket.  Tighten the clips to the point were the back of the monitor’s front bezel just begins to contact the front of the NEMA enclosure.  DO NOT OVER TIGHTEN AS DAMAGE CAN RESULT IN THE MONITOR CAUSING LOSS OF SEALING INTEGRITY.


Mode and Image Adjustment

Not all video controllers produce exactly the same video output levels or the same timing.  The following procedure can be used to select the desired video mode as well as optimize your monitor’s image quality.  When adjusting your monitor, the use of video test software such as DisplayMate for Windows by SONERA Technologies can be very beneficial.

The XT1502 uses “On Screen Programming” to make setup and adjustment easy.  The menus are selected and the menu items are adjusted using the buttons located on the monitor’s front panel.  These buttons are enabled or disabled by a rocker switch labeled “SET UP” located on the side of the monitor.

This feature is provided to inhibit tampering once the monitor is in actual use.  Turn the SET UP switch to the ‘On’ position to enable set up and adjustment.  The following section describes the functions of the front panel buttons. Before connecting the XT1502to your computer, adjust your desktop display settings to the following:

Colors:256

Vertical Refresh: 60Hz

Resolution:1024 x 768

Monitor Type:Viewsonic 15

Once the monitor is powered up press the menu button.  After the On Screen Display (OSD) menu appears select the Auto Setup function by scrolling down using the  button a then activate this function by pressing the  button.  The monitor will automatically adjust to the incoming video signal. Now select the Tuning function and fine-tune the image using the ⇐  and  brightness and contrast settings to your individual preference.buttons.  Finally, set the brightness and contrast settings to your individual preference.


Back Light Replacement Procedure

This procedure applies to the XT1502 only.  After 50,000 hours of typical use, the two lamps used for back lighting in the XT1502 may become dim or burn out.  You may return the monitor to Viewtronix for lamp replacement or you can order new lamps and follow the procedure below to install them.

• TURN THE MONITOR POWER OFF AND DISCONNECT THE LINE CORD!

• Loosen the two thumbscrews located on the top of the back.

• The hinges located on the bottom of the monitor allow you to swing open the back. If the unit is equipped with a touch screen, you may want to disconnect its cable.  This is a white flat flexible cable that plugs into a five-pin black bulkhead connector located to the left of the LCD.

• Disconnect the two pairs of back light (pink and white silicone wires on the right upper and lower corner of the LCD) wires from the inverter extension cables.

• The lamps do not require tools for removal.  They are mounted in small plastic holders that slide outward to the right of the LCD.  Carefully pull on the pink and white wires to begin removing the lamps.

• Now slide the new lamps into place.

• Reconnect the lamp wires to the inverter extension cables.  Make sure you carefully tuck the wires under the LCD so they cannot be pinched when closing the back of the monitor.

• You may now want to clean the LCD and the inside of the monitor’s window or touch screen with a slightly damp soft cloth.

• Carefully close the back remembering to slide the flat flexible touch screen cable behind the LCD.

If you previously disconnected this cable, you should now reconnect it with pin-1 in the up position, making sure the cable is free of any twists.

• The lamp replacement procedure is now complete


Core functions

(1) Intuitive operating interface

The XT1502T Pro Face is equipped with a 15 inch high-resolution color LCD display, which has clear images and bright colors, and can vividly display various operating parameters, status information, and operation interfaces of industrial equipment. Its touch operation design conforms to ergonomic principles, with sensitive response and convenient operation. Operators can easily complete tasks such as device monitoring, parameter setting, and command issuance through simple touch clicks, swipes, and other operations. Both beginners and experienced operators can quickly get started, greatly improving operational efficiency and reducing operational error rates.

(2) Efficient data exchange

Equipped with rich communication interfaces, it can stably and efficiently exchange data with various industrial equipment and control systems. Through Ethernet interface, it can quickly connect to industrial networks and achieve real-time data transmission and sharing with devices such as PLC (Programmable Logic Controller), frequency converter, sensors, etc; Serial communication interfaces such as RS-232 and RS-485 can meet the communication needs of different devices, ensuring close collaboration between the human-machine interface and various links in industrial systems. On the industrial automation production line, XT1502T Pro Face can collect real-time equipment operation data, display it intuitively on the operation interface, and send control signals to the equipment in a timely manner according to the instructions of the operator, achieving precise control and optimization of the production process.

(3) Powerful data processing and analysis

Built in high-performance processor and data processing module, capable of quickly processing large amounts of industrial data. Real time analysis and processing of collected equipment operation data, such as calculating production efficiency, counting equipment failure times, monitoring data anomalies, etc., and displaying the analysis results in intuitive forms such as charts and curves to help operators quickly understand the production operation status, discover potential problems and optimize space in a timely manner. By storing and querying historical data, powerful data support can also be provided for production management, equipment maintenance, and decision-making in enterprises.

(4) Stable and reliable operation

Using high-quality electronic components and optimized hardware design, it has undergone rigorous industrial testing and verification, and has excellent anti-interference ability and environmental adaptability. It can still maintain stable working conditions in harsh industrial environments such as high temperature, high humidity, and strong electromagnetic interference. The front panel design with IP65 protection level effectively prevents damage to equipment caused by dust, water splashes, etc., ensuring the reliability and durability of products in complex industrial environments, reducing downtime caused by equipment failures, and lowering production and maintenance costs for enterprises.


Precautions

(1) Installation requirements

Before installing XT1502T Pro Face, be sure to turn off the power of the relevant equipment and take anti-static measures, such as wearing an anti-static wristband, operating on an anti-static workbench, etc., to prevent static electricity from damaging the equipment. During the installation process, strictly follow the instructions in the product installation manual, correctly install the human-machine interface in the designated position, and ensure that it is firmly fixed. Pay attention to keeping the installation environment dry and well ventilated, and avoid installing in environments with high temperature, humidity, dust or corrosive gases to ensure the normal service life and performance of the equipment. At the same time, ensure that communication cables and power cords are connected correctly and firmly to avoid data transmission abnormalities or equipment failures caused by improper connections.

(2) Usage standards

During use, non professionals are strictly prohibited from arbitrarily changing the hardware settings and software parameter configurations of the device. If adjustments are required, they must be carried out by professional technicians in a power-off state, following the instructions in the product manual. Avoid frequent plugging and unplugging of communication cables or other equipment during device operation to prevent damage to equipment components due to transient current surges. Ensure stable and compliant power supply for the equipment to avoid equipment failure caused by power fluctuations or abnormalities. At the same time, regularly clean the equipment by wiping the screen and casing with a clean, soft cloth, avoiding the use of corrosive cleaning agents, and preventing damage to the surface of the equipment.

(3) Maintenance and troubleshooting

Regularly inspect and maintain the XT1502T Pro Face, checking the device's operating status, screen display effect, touch operation response, etc. to ensure they are functioning properly. If abnormal display (such as black screen, blurred screen, color distortion, etc.), touch operation failure, communication failure, etc. are found on the screen, you can refer to the troubleshooting guide in the product manual for preliminary inspection and diagnosis. Check whether the communication cable connection is loose, whether the interface is damaged, and whether the equipment power supply is working properly. For more complex faults, it is recommended to promptly contact Xycom's technical support personnel or professional maintenance personnel for handling. Do not disassemble the equipment on your own to avoid more serious damage. At the same time, regularly backup important data and programs in the device to prevent data loss due to device failure.


  • Pro-face / Xycom 4612T / 4612-102031015 - Flat Panel Industrial PC
  • Xycom XVME-203 / 70203-001 - VME Board
  • Xycom XVME-957 / 70957-001 - Mass Storage Sub-System
  • Xycom 9403t - Power Board
  • Xycom 3515-KPM - Operator Interface
  • Xycom XVME-560 / 70560-001 - AIN Analog Input Module
  • Xycom / Adept XVME-201 / 70201-001 - VME Digital Counter I/O Module Board Card
  • Xycom 9460 - Touch Screen
  • Xycom Automation 9000-FFP-HU - Module
  • Xycom XVME-201 - Digital I/O Controller Card
  • Xycom / Pro-face 5015T/R2 - Panel
  • Xycom 103711-001 / 103709 - Circuit Board Card
  • Xycom / Pro-face 5015KPMT - Operator Panel
  • Xycom SXT1811T / 1811-C00000000 - Touch Panel
  • Xycom / Analogic CDA XVME - VME TI DSP SCSI I/O Module Serial RS232 Card Board
  • Xycom 4153/C - Control Interface
  • Xycom / Pro-face 1547 / 1547-00113101 - Industrial Computer
  • Adept 10350-01064 - AWCII 060 Computer/CPU Module Card for MV Controller
  • Xycom / SPX Air Gage 3515 KPM / PM101874B - Operator Interface Panel
  • Xycom / Pro-face 5015T/R2 - Flat Panel Touch Monitor (Not Working)
  • Xycom 3515 - Operator Interface
  • Xycom 9406AC - Industrial Computer
  • Xycom 8100-0272A / 278811XFF - CNC Brown Out Sensor/PROM Card
  • Xycom 3115T / 1200-256-2K-N1 - Operator Touch Panel (For Parts)
  • Xycom 83060CA - Processor Module Board
  • Xycom XVME-540 - VMEbus AIO Module
  • Xycom XVME-955 - Floppy Disc Hard Drive Module
  • Xycom 2005 - 9-inch LCD Upgrade Kit for CRT with Cable Kit
  • Xycom 9000-EXF - Industrial Component
  • Xycom 4860A / 91886-001 - 12" Operator Interface Panel Terminal
  • Quarndon Systems / Xycom XVME-220 - 32pt Programmable Scanner
  • Xycom 98405A-001 - Main Board
  • Xycom / ViewTronix VT1040T - Touch Screen
  • Xycom XVME-566 / 74566-002 - Fast Analog Input VMEbus Module
  • Xycom 9987 / 9987-71338-010 - HMI & Open Interface Panels Display
  • Xycom 4100-AT2 - Single Board Computer PC/ATbus Product Manual
  • Xycom 8450 - LCD monitor with cables for 14inch display
  • Generic MP9W - LCD replacement for 12 inch Monochrome CRT with cables
  • Xycom / Pro-face 5017T - 17" Industrial Touch Monitor (For Parts/Repair)
  • Xycom XVME-675 / XVME-956 - Computer Module (Intel 100Mhz, SCSI, Networking, VGA)
  • Xycom 3100M / 3100-000000000 - Operator Interface
  • Xycom / Pro-face ST401-AG41-24V - Graphic Touchscreen Operator Interface
  • Xycom Automation 1300-000100000 - Node Module
  • Xycom 3615KPM - Operator Interface
  • Xycom 5019 / 5019-A00000000 - Operator Interface Screen Monitor (Not Working)
  • Xycom XVME-688 / 70688-011 / 71688C-001 - VMEbus CPU
  • Xycom XVME-977 / 70977-011 - VME Bus Card with Floppy Drive
  • Xycom 10330-00800 - Digital I/O Board
  • Xycom 9486 - Operator Interface Panel
  • Xycom 9462 - 12.1-inch Operator Interface Panel
  • Xycom XVME-428/1 - VME Bus Intelligent Asynchronous Serial Communication Module
  • Xycom XVME-957 / 70957-001 - VMEbus Mass Storage Sub-System
  • Xycom XVME-660 / 70960-001 - Processor Module Top Board
  • Xycom Automation / Pro-face XT1502T - Operator Interface
  • Xycom / SVG Thermco XVME-203/293 / 70203-001 / 602939-01 - VMEbus Module with Quadrature
  • Xycom 3015T - Operator Interface Panel
  • Xycom XVME-202 - Controller Module Board
  • Xycom XVME-545 - VMEbus Module
  • Xycom 1300-Client-AC - ACP Node
  • Xycom 2000T / 97957-101 - Operator Interface
  • Xycom XVME-682 / 716828-100 / 92373-001 - VMEbus Processor PCB Board
  • Xycom 9450 - PC/AT Computer Operator Interface HMI Screen Monitor Keypad Control
  • Xycom Automation 9987 / 9987-3338-2 - Operator Interface Computer Board
  • Xycom 2060 - 12-inch LCD upgrade monitor with Cable Kit
  • Pro-face / Xycom PFXGP4501TAA - 10.4 inch TFT Color LCD
  • Xycom XVME-401 / 70401-001 - VMEbus Module
  • Xycom / Pro-face 5019T-SER - Operator Interface Screen Monitor
  • Xycom 81625DA - Control Board
  • Xycom 9465 / 01631B001601J - Operator Interface Industrial Computer Terminal
  • Adept / Xycom 10332-00800 - I/O PC Board VME Digital DIO Module
  • Xycom 4810A - 9-inch LCD monitor upgrade with Cable Kit
  • Xycom XVME-540 / 86-16098-001 - AIO VMEbus Module
  • Xycom XVME-212 / 70212-001 - 32 Channel Programmable Scanner VMEbus DIN Module
  • Xycom 510084 - Power Supply Board
  • Xycom XVME-240 / 70240-001 / 2800302 - DIO VMEbus Module Card
  • Xycom 9450-248661601 - HMI Panel
  • Xycom 9450 / 9450-27B131901 / 713332 - HMI Panel Display
  • Xycom 9450 / 4664 - Automation Interface Screen Monitor
  • Xycom XVME-220 - VMEbus 32pt Programmable Scanner DOUT
  • Xycom XVME-979 - CD-ROM/HDD/FDD Interface Card/Module for MV Controller
  • Xycom XVME-505/1 / 70505-001 - VME Analog I/O Module
  • Xycom 4615T - HMI
  • Xycom XVME-675 / 957 / 956 - VME Bus Card Floppy Drive CPU Assembly
  • Xycom 9485 / 9485-27A131701 - Operator Interface Panel
  • Xycom XVME-566 - Analog Input Module
  • Xycom 99142-025 - Circuit Board
  • Xycom 4615kPM - HMI / Operator Panel
  • Xycom Automation QPI-MBP-XA1 - Modbus Plus Communication Module
  • Xycom XVME-085 - Proto VMEbus Prototyping NIKL VME Module
  • Xycom Pro-face 1547 / 1547-00113101 - Industrial Computer
  • Xycom 81987-001-D / 1805 - General Purpose I/O Circuit Board
  • Xycom XVME-505/1 - VMEbus Analog I/O Module
  • Xycom Pro-face GLC150-BG41-DNM-24V - Graphic Logic Controller
  • Xycom Pro-face 3310T / 3310-001101001 - Operator Panel
  • Xycom 99157-001 - Circuit Board
  • Xycom Pro-face 5017T - 17" Industrial Touch Monitor
  • Xycom XVME-202 - VMEbus Module
  • Xycom XVME-103 / 10103-001 / 70401-001 - VMEbus CPU Module
  • Xycom XVME-240 - DIO VMEbus I/O PCB
  • Xycom XVME-977 - VME Bus Card with Floppy Drive
  • Xycom 4860VME - Keypad Operator Interface Panel Terminal Monitor
  • Xycom 8000 KB3 / 97788-001 - Keyboard
  • Xycom 71602C-100 - VME Board
  • Xycom XT1502-BB-RB / PM-102000 - Display Panel
  • Xycom Pro-face 5019T / 5019-A10010000 - Industrial HMI Display
  • Xycom / MESA Electronics 70956-411C / 4I29X - 16 Bit Ethernet PLC Card
  • Xycom 99222-001 - Industrial PC Board
  • Xycom XVME-955 - Storage Module for MV Controller (No HDD)
  • Xycom XVME-110 / 70110-001 - VMEbus Module
  • Xycom Automation 5019T / 5019-A10010000 / 144602-RS - HMI Display
  • Xycom 2000-KB1 / 94687-001 - Keyboard / Keypad
  • Xycom XVME-401 / 70401-001 - VMEbus Module
  • Xycom XVME / CU040103500 / 4200401 - VMEbus Rack Component
  • Xycom XVME-404 / 70404-001 - VME Disc Drive Controller Module
  • Xycom 3410-KP - 10.4" Operator Interface Flat Panel Industrial PC (For Parts)
  • Xycom / Micro Vitec 9457 / 9457-023812001 / 9457-713332 - Operator Interface Panel
  • Xycom XVME-675 / XVME-956 / PM101558 - CPU Module with DISK Module
  • LAM Research / Xycom 810-17033-003 / 70110-003 - 512K SRAM PCB Card
  • Xycom XVME-100 / 70100-001 - ROM PCB Board
  • Xycom Pro-face 5015T - Touch Monitor
  • Xycom Automation 1300-000100000 - Operator Interface
  • Xycom XVME-675 / XVME-956 / 70675-098 - CPU Module with DISK Module
  • Xycom 3015 / 139001-001 - Operator Interface Panel
  • Xycom Automation 143913-001 / 13ZT103-00-010 - TSKAM Board
  • Xycom XVME-956 - Disk Module
  • Xycom 3308-KP - Industrial Workstation
  • Xycom PMXVME-230 / PM-101659 - VMEbus Intelligent Counter Module
  • Xycom 4870 - Operator Interface Panel