K-WANG
ZYGO ZMI 501A shell
Basic product information
Product Code and Configuration: Model ZMI 501A, corresponding to part number (P/N) 8020-0237-05, with 2 channels
Physical characteristics
Dimensions and Weight: The weight is 2 pounds (approximately 1 kilogram), and the specific external dimensions need to refer to the figures in the document (Dimensions: See Figure)
Cable gap: The gap between both ends of the cable is 5 inches (127 millimeters)
Installation and heat dissipation: Adequate ventilation space should be reserved to ensure heat dissipation, and it cannot be installed near the measuring axis; The bottom mounting hole includes two specifications, M3 threaded hole (depth 4 millimeters) and 6-32 UNC threaded hole (depth 1/8 inch), with the use of 6-32 UNC threaded hole being optional
Electrical parameters
Power requirements: The nominal power supply is+5.2 volts direct current (VDC), with an allowable voltage fluctuation range of -0.0/+0.4 volts, and a working current of 3.3 amperes
Environmental parameters
Working temperature: Applicable temperature range is 0 to 40 degrees Celsius
Working humidity: Suitable humidity range is 0 to 85%, and it needs to be in a non condensing environment
Core specifications of measuring board
Basic configuration: A single measurement board supports 2 axes (Number of Axes per Board: 2), with a minimum optical input power of ≥ 8 microwatts (μ W) and a linear accuracy of 1.3 LSB
Serial (Orthogonal) Data Specification (Based on Dual Channel Interferometer):
Highest position resolution: λ/512 (approximately 1.24 nanometers)
Maximum position range: 10.6 meters
Maximum speed of target reflector: 475 millimeters per second
Data rate: selectable between 3 and 24 megahertz (MHz)
Parallel data specification (based on dual pass interferometer):
Position resolution: fixed at λ/512 (approximately 1.24 nanometers)
Position range: fixed at ± 10.6 meters
Maximum speed of target reflector: 475 millimeters per second
Precautions
Safety specifications are generally applicable to control system handling. Instructions and warnings related to a specific subject or operation of the product.
The following norms must be strictly observed:
must strictly comply with the technical specifications and typical applications of the product system
Personnel training: Only trained personnel shall install, operate, maintain or repair the product system. must
Provide guidance and explanation of the situation in danger areas to these personnel.
Unauthorized changes: Changes or structural changes to the product system may not be made.
Maintenance responsibility: Must ensure that the product system is used only under appropriate conditions and in full fitness for use.
Working environment: The user must meet the specified environmental conditions:
Safety regulation
The following safety provisions of EN 50110-1 shall be fully complied with when handling product systems (maintenance) :
1 Disconnect completely.
2 Secure to prevent reconnection.
3 Verify that the installation is complete.
4 Ground and short-circuit the device.
Warning: Only qualified maintenance personnel can remove and insert the module. In order to ensure the personal safety of the operator, before each pulling out or inserting, you must
Disconnect the power supply and ensure that there is no voltage on all terminals at the back, and the product is effectively grounded with the ground screw at the back.