General specifications
Power supply: 24V d.c. (19.2 - 30V)
Temperature range: 0…55°C
Protection class: IP20
Standards complied with:
Electrical safety: EN 3810, EN 5017-8, IEC 61131-2,
UL508, CSA 22.2 No. 142-M1987
Hazardous locations (Class 1, Div. 2):
CSA 22.2 No. 213-M1987, FM 3600, FM 3611, UL 1604
Corrosive gases: ISA Class G2 (G3 pending)
Isolation test voltage: 500/2000V a.c.
Communication media
Advant Fieldbus 100. Twisted pair screened/coaxial/fiberoptic cable. Up to 79 stations per bus. Up to 32 per
twisted-pair segment. Bus length: Up to 750m
(2 460ft.) per twisted-pair segment overall up to:
15km (9.3 miles).
Profibus DP. Twisted pair screened/fiber-optic cable. Up to
99 stations per bus. Up to 32 per twisted-pair
segment. Bus length: Up to 1200m (3937ft.) per
twisted-pair segment.
Communication interfaces
CI810 For Advant Fieldbus 100. Supports dual bus-cable
redundancy.
CI801 For PROFIBUS-DP/V1. Hot Configuration in Run &
HART® pass-through. GSD-file provided.
TB820 / 825 / 810 / 811 / 842. Optical cluster modem/ports
for ModuleBus/drives integration.
Redundant interface
CI820 For redundant Advant Fieldbus 100 in combination
with Advant Controller 400 series controllers.
TB815 Interconnection Unit. An electrical and optical
ModuleBus interface for coordination of the two
parallell CI820 needed.
CI840 For redundant PROFIBUS-DP/V1. Hot Configuration in Run & HART® pass-through. GSD file
provided.
TB840 Optical cluster modem for redundant Modulebus.
Installed on TU840/TU841. Used with AC 800M.
Module Termination Units (MTU:s)
Compact, 50V applications
TU810 With screw terminals.
TU812 With 25 pin D-sub connector.
TU814 With 3 crimp snap-in connectors.
Compact, 250V applications
TU811 With screw terminals.
TU813 With 3 crimp snap-in connectors.
Compact for intrinsic safety
TU89X With screw terminals & isolated power supply.
Extended, 50V applications
TU830 / TU835 / TU838
With screw terminals, pwr. distribution & fuse.
TU833 With spring-cage term., pwr. distribution & fuse.
Extended, 250V applications
TU831 / TU836 / TU837
With screw terminals, pwr. distribution & fuse.
Redundancy, 50V applications
TU842 / 843 (horiz./vert. mounting) w. screw terminals.
TU844 / 845 (horiz./vert. mounting)
With screw terminals and shunt sticks, TY80X.
TU805 For DI801 & DO801. With field power distribution
screw terminals.
Station layouts
No. of I/O modules:
Up to 24 per I/O station.
Extension cable:
Plug-in, lengths: 0.3, 0.6 and 1.2m (1, 2 & 4ft).

Optical ModuleBus: Up to 7 I/O clusters and/or 24 I/O
modules. Max length: 15 or 200m (49 or 656ft).
S800 I/O modules
Digital input modules
DI810 16 channels, 2 groups of 8 ch., 24V d.c., current
sink.
DI811 16 ch., 2 groups of 8 ch., 48V d.c., current sink.
DI814 16 ch., 2 groups of 8 ch., 24V d.c., current source.
DI820 8 ch., separate returns, 110V d.c., 120V a.c.
DI821 8 ch., separate returns, 220V d.c., 230V a.c.
DI825 With time tagging, 8 ch., sep. returns, 125V d.c.
DI830 With time tagging. 16 ch., 2 groups of 8 ch., 24V
d.c., current sink. Resolution: <0.5ms.
DI831 With time tagging. 16 ch., 2 groups of 8 ch., 48V
d.c., current sink. Resolution: <0.5ms.
DI885 With time tagging & wire-fault detection.
8 ch., common return, 24-48V d.c., current sink.
Time tagging resolution: 1ms.
Pulse input module
DP 820 2 channels, separate returns, 0.25Hz - 1.5MHz,
signal voltage: 5 / 24V d.c.
Digital output modules
DO810 16 channels, 2 groups of 8 ch., 24V, max 0.5A d.c.,
transistor, current source, short-circuit-proof.
DO814 16 ch., 2 groups of 8 ch., 24V d.c., max 0.5A,
transistor, current sink, short-circuit-proof.
DO815 8 ch., 2 groups of 4 ch., 24V d.c., max 2A,
transistor, current source, short-circuit-proof.
DO820 8 ch., separate returns, 5-250V, max 3A a.c./d.c.,
relay (N.O.).
DO821 8 ch., separate returns, 5-250V, max 3A a.c./d.c.,
relay (N.C.).
Analog input modules
AI810 8 channels, single-ended, 0(4)-20mA, 0(2)-10V, 12
bits.
AI820 Differential inputs, 4 ch., 0(1)-5V, ±0(2)-10V,
±0(4)-20mA, 14 bits + sign.
AI825 Galvanically isolated, 4 ch., ±0(2)-10V, ±0(4)-
20mA, 14 bits + sign.
AI830 RTD inputs, 8 ch., Pt100, Ni100, Ni120, Cu10,
resistor 0-400Ω, 14 bits, 3-wire.
AI835 TC inputs, 8 ch., (7+ ref. junction), separate
returns. TC types B, C, E, J, K, N, R, S, T, -
30…75mV, 15 bits.
Analog output modules
AO810 8 channels, common return, 0(4)-20mA, 14 bits,
load: 850Ω (short-circuit-proof).
AO820 Isolated output. 4 ch., separate returns,
measuring range: ±0(2)-10V, ±0(4)-20mA,
resolution: 12 bits + sign, load: ≤500Ω (current) /
≥2kΩ (voltage), short-circuit-proof.
I/O modules with intrinsic-safety interface
DI890 digital inputs with wire-fault detection
8 ch., separate returns, 24V d.c., current sink.
DO890 digital outputs with wire-fault detection
4 ch., separate returns, load 150-5000Ω, 11V @
40mA, current source, short circuit-proof.
AI890 Analog inputs. 8 ch., single-ended, 0(4)-20mA, 12
bits, transmitter power supply
AI893 TC/RTD inputs. 8 ch., TC: 7 + ref. junction, sep.
returns. TC types B, C, E, J, K, L, N, R, S, T, U,
-10…80mV. RTD: Pt50-1000, Ni100-500, Cu10-
100, resistor 0-4000Ω, 3-wire. 15 bits + sign.
AI895 with intrinsic safety & HART interface
8 ch., single-ended, 4-20mA, 12 bits, transmitter
power supply.
AO890 with intrinsic safety & wire-fault detection
8 ch., common return, 0(4)-20mA, 12 bits, load:
750Ω (short-circuit-proof).
AO895 with intrinsic safety, HART interface & wire fault detection. 8 ch., common return, 4-20mA, 12
bits, load: 750Ω (short-circuit-proof).
S800L I/O modules
DI801 16 channels, 1 group, 24V d.c., current sink.
DI802 8 ch., 110V d.c., 120V a.c.
DI803 8 ch., 220V d.c., 230V a.c.
DO801 16 ch., common return, 24V, max 0.5A d.c.,
transistor, current source, short-circuit-proof.
DO802 8 ch., 5-250V, max 2A a.c./d.c., relay (N.O.).
AI801 8 ch., single-ended, 0(4)-20mA, 12 bits.
AO801 8 ch., common return, 0(4)-20mA, 12 bits, load:
<750Ω.
S800 I/O modules for redundancy & SIL3
DI840 16 channels, common return, 24V d.c., current
sink, extended diagnostics.
DI880 16 ch., 24V d.c., current sink, SIL3, extended
diagnostics.
DP840 8 ch., sep. returns, freq. measurement or pulse
counting, 0.5-20 kHz, 12/24V d.c or NAMUR.
DO840 16 ch., common return, 24V d.c., max. 0,5A,
current source, short-circuit-proof, extended
diagnostics.
D0880 16 ch., 24V d.c., max. 0.5A, current source, SIL3,
short-circuit-proof, extended diagnostics.
AI843 TC input, 8 ch. + ref. junction. TC types: B, C, E, J,
K, L, N, R, S, T, U, -30…75mV, 16 bits, extended
diagnostics.
AI845 8 ch., common return, 0(4)-20mA 0(1)-5V,
extended diagnostics, HART support.
AI880A 8 ch., common return, 0(4)-20mA, SIL3, extended
diagnostics, HART support.
AO845 8 ch., common return, 4-20mA, extended