ABB 3BHS600000 E80 RevF Service Manual PCS6000

From: | Author:Wang | Time :2025-05-24 | 700 visit: | 🔊 Click to read aloud ❚❚ | Share:

ABB 3BHS600000 E80 RevF Service Manual PCS6000

Security and Tools

Safe Working Practice

Strictly follow the "Seven Step Life Saving Rule", including risk assessment, power outage lockout (LOTO), voltage detection, grounding short circuit and other processes, to ensure operational safety.

The equipment poses risks of high voltage, high temperature, and electromagnetic fields. Maintenance personnel need to wear protective equipment to avoid contact with live parts and high-temperature surfaces.

Residual risks include electromagnetic interference with pacemakers, accidental movement, contact voltage, etc. It is necessary to ensure that the equipment operates within the specified parameter range.

special tools

Converter service toolbox: includes expansion tools for disassembling semiconductor stacks, stabilizing boards, etc., used to release stack pressure and replace components.

Debugging tools: such as RCI Box XU D194 (signal monitoring), PCS6000 HMI (human-machine interface), FADEC 3 (semiconductor testing equipment).

Replacement tools: including foundation beam jacks, chain hoists, pump maintenance platform kits, etc., used for dismantling and installing heavy components.

Preventive maintenance

Maintenance cycle and tasks

Daily/quarterly: visually inspect for dust and signs of overheating, clean cabinets, check bolt tightness and cable wear.

Year: Test the tripping circuit, insulation resistance, and grounding resistance of the main circuit breaker (MCB), and replace aging components such as batteries and fans.

Specific inspection:

Semiconductor stacking: Use FADEC 3 to detect IGCT and diodes, check stack alignment and clamping force.

Cooling system: Check the conductivity of the coolant, replace the ion exchange resin and filter, and inspect the function of the pump and valve.

Filter components: measure resistance and capacitance values to verify filtering performance.

Maintain records

Use the Preventive Maintenance Report to record component replacements, parameter adjustments, and abnormal situations to ensure traceability.


Component replacement and repair

1. Replacement of control components

AC 800PEC controller: Replace after power failure, pay attention to firmware version matching, and verify LED status after reconnecting the cable.

UPS and battery: When replacing, power off and release residual voltage. Pay attention to matching battery polarity and model, and test the charging and discharging function.

Fiber optic cable: Cut and polish with specialized tools to ensure that the connection loss meets the standard and avoid contaminating the fiber optic end face.

2. Replacement of power and cooling components

IGCT and diode:

Release the stacking pressure, use the expansion tool to separate the heat sink, replace it, realign the stack and tighten it.

Check the polarity and clean the contact surface, avoid using grease, and ensure even clamping force.

Cooling system components:

Pump: Drain the coolant, remove the flange and electrical connections, replace with a dedicated bracket, pay attention to the direction and sealing of the impeller.

Ion exchanger and filter: After replacement, the system needs to be flushed to test flow rate and conductivity.

Valves and sensors: After replacement, pressure and temperature sensors need to be calibrated to ensure that the control system is functioning properly.

3. Module level replacement

Voltage Limiting Module (VLM): After power failure, remove the cables and cooling pipelines, replace them, and test the voltage relief function.

Grid Circuit Breaker Unit (GBU): Use a dedicated trolley to disassemble the circuit breaker, check the wear of the contacts, reinstall and test the opening and closing time.

Dv/dt filter: When replacing reactors, resistors, and capacitors, it is necessary to match the model and parameters to ensure EMI suppression performance.

4、 Troubleshooting process

diagnostic procedure

Read the fault code through HMI or debugging tools, analyze the first fault (FF) and related alarms, check the LED status and historical records.

Check the power supply, communication links, sensors, and semiconductor components, and use tools such as multimeters and oscilloscopes to measure voltage and resistance values.

Typical fault handling

IGCT fault: Conduct characteristic detection through FADEC 3, replace and recalibrate trigger signal.

Cooling system leakage: locate the leakage point, replace the seals or pipelines, and test whether the pressure and flow are normal.

Communication interruption: Check the fiber optic connection, module power supply, and address settings, and replace the faulty S800 I/O module or communication board.

5、 Special precautions

Static Electricity Protection (ESD)

When operating the control board and semiconductor, it is necessary to wear a grounding wristband and use anti-static pads to avoid direct contact with circuit contacts.

Heavy component operation

Components weighing over 25 kg, such as reactors and circuit breakers, require the use of lifting tools, with two people working together to avoid the risk of falling.

Documentation and Compliance

Replacing serialized components (such as IGCT and capacitors) requires updating the ABB database and recording the new serial number.

Follow environmental requirements, dispose of waste components (such as batteries and circuit boards) correctly, and avoid environmental pollution.


The relevant models and component models of ABB PCS6000 are as follows:

Main device model

PCS6000

The medium voltage frequency converter models covered by the core of the manual are suitable for industrial scenarios such as large wind turbines and tidal energy, and support 1CL (single conversion line) and 2CL (dual conversion line) configurations.

Core component model

1. Power Unit (POU)

IGCT model:

5SHY 3545L0016 (old generation)

5SHY 4045L0006 (new generation, can replace old models one-on-one)

DC capacitor:

DCMKP 2.6kV/2x1.5mF(3BHB006617R0013)

DCMKP 3.15kV/2x1.01mF(3BHB006617R0014)

2. DC Link Unit (DLU)

Neutral Connection Module (NCM):

Includes resistors - R461, - R462_1/- R462_2, and capacitor - C461.

Voltage Limiting Module (VLM):

VLM30 (weighing approximately 50kg), VLM70 (weighing approximately 60kg).

Dv/dt filtering module (VFM):

Reactors, resistors, and capacitors components (such as - R581 to - R586, - C581 to - C587).

3. Grid Circuit Breaker Unit (GBU)

Circuit breaker model:

GEB (Generator Circuit Breaker), GRI (Grid Circuit Breaker), weighing approximately 160kg, compatible with VD4 series.

Dv/dt filter component:

Reactors, resistors, capacitors (such as - R581 to - R586, - C581 in GBU).

4. Water cooling unit (WCU)

Pump model:

Sweden water series: such as 300l/min pump (3BHE038551R0001, weight 77kg), 565l/min pump (3BHE043674R0001, weight 90kg).

ARMATEC series: Please refer to the accompanying service manual (such as Appendix B06).

Ion exchanger: For resin model adaptation, please refer to Safety Data Sheet (SDS) 81000-193.

5. Filter Unit (FIU)

High pass filtering module (HFM):

Reactors (such as 3BHE035425R0001, weighing 25kg) and capacitors (- C541 to - C544, weighing 41kg).

Filter Reactor Module (FRM):

For FRM70 (weighing 900kg), a dedicated replacement kit (3BHE039651R0001) is required.

6. Braking resistor unit (BRU)

model:

BRU50 (200kg), BRU51 (235kg), BRU70 (400kg), etc., suitable for different power requirements.


Control and auxiliary components

AC 800PEC controller:

PP D113 B03-20-110110(3BHE023584R204Z)。

S800 I/O module:

DI811 (digital input), AI810 (analog input), DO820 (digital output).

Power module:

QUINT-PS/3AC/24DC/40 (AC/DC converter, 3BHE031065R0001)

QUINT-DC-UPS/24DC/40(UPS,3BHB056371P0

ABB PSTX300-600-70 全智型软起动器/电机启动器(PSTX系列)

  • ADLINK HPCI-14S12U - Industrial Control Backplane 12PCI Backplane PCI-14S Passive Backplane
  • ADLINK PCIe-GIE74C - image acquisition card 4-CH GigE Vision PoE+ Frame Grabber
  • ADLINK PCI-8164 - control card 4-Axis Advanced Motion Controller Board
  • ADLINK PCIe-U304 - 4 Port USB3 PCIe Frame Grabbers USB Screw Hole Card
  • ADLINK PCI-9112 - Multi-Function Data Acquisition Card DAQ Card
  • ADLINK PCI-7432 - 51-12013-0A50 4-CH Isolated Numérique I/O PCI Cartes Digital I/O Card
  • ADLINK PCA-6106P3-0C1 REV.C1 - backplane 6-Slot Passive Backplane Board
  • ADLINK PCI-7224 - 24-CH Opto-Isolated Digital I/O PCI Board
  • ADLINK CPCI-7433R(G) - Digital Input Board Rear I/O CompactPCI Card
  • ADLINK EBP-13E4 - 51-46703-0A30 Industrial PC Backplane Passive Backplane
  • ADLINK PCIE-HDV62 - Image acquisition card High Definition Video Frame Grabber
  • ADLINK EBP-13E4 - 51-46703-0A30 Industrial Backplane Board Passive Backplane
  • ADLINK 90111-B1 / CPCI-6770 - PCB CPU MODULE CompactPCI Single Board Computer
  • ADLINK PCI-7248 - DATA ACQUISITION PCI CARD 48-CH Parallel Digital I/O Board
  • ADLINK PCI-7230 - 51-12003-0a50 board PCI7230 32-CH Isolated Digital I/O Card
  • ADLINK PCI2A000CB - 51-20000-0B30 Multi-Function DAQ Card Baseboard
  • ADLINK PCI-8134-005 - 4-Axis Motion Controller Card
  • ADLINK PCI-7224 - 24-CH Opto-Isolated Digital I/O PCI Card
  • ADLINK PCI-7434 - 64-CH Isolated Digital Output Card
  • ADLINK PCI-8132 - motion control card 2-Axis Servo & Stepper Controller
  • ADLINK PCI-8134 - Motion Controller PCI Card 4-Axis Controller Board
  • ADLINK PCI-8164 - Motion Control Card 51-12406-0A40 4-Axis Controller
  • ADLINK 51-12001-0C20 - Circuit Board Data Acquisition Interface Module Hardware
  • ADLINK NuPR0-840 - industrial control motherboard Full-Size PICMG CPU Board
  • ADLINK PCI-7444 - 51-12023-0A10 card 128-CH Isolated Digital Output Board
  • ADLINK PCI-1612B - data acquisition card 4-Port RS-232/422/485 Serial Communication Card
  • ADLINK PCI-6208V 009 - 8/16-CH 16-Bit Analog Output Cards PCB-I-E-482=6BX3
  • ADLINK NUPRO-935A/LV - industrial control motherboard Full-Size PICMG SBC Board
  • ADLINK PCI-9114DG - Multi-Function DAQ Card Data Acquisition PCI Card
  • ADLINK ACL-7130 - Data acquisition card Isolated Digital I/O Board
  • ADLINK ABX-6300D-4E1-BP - board ABX6300D4E1BP Video Interface Expansion Card
  • ADLINK CPCI-6940 - CPCI-6940/D1539/M16-0(EA)-000E 6U CompactPCI Processor Board
  • ADLINK NuPRO-760 - industrial control motherboard Half-Size PICMG SBC CPU Board
  • ADLINK IMB-M42H (G)-0020 - industrial control motherboard LGA1155 Micro-ATX Mainboard
  • ADLINK RTV-24 / PCI-MP4S - 51-12519-1C30 4-Channel Real Time Video Capture Board
  • ADLINK PCI-8134 - 4-Axis Servo & Stepper Motion Controller Card
  • ADLINK MXC-6101D - V.PC000.002.ST.00 Box PC Configurable Embedded Computer
  • ADLINK PCI-8134A - 51-12421-0A10 Motion Control Card 4-Axis Controller Card
  • ADLINK DIN-100S / DIN-100SA1 - Technology SCSI-II TB 100-PIN Terminal Block Board
  • ADLINK DIN-812M001 / DIN812M001 - 51-14034-0A1 51140340A1 Terminal Module Breakout Interface
  • ADLINK PCI-8164 - Servo motion control 4-Axis Advanced Controller Card
  • ADLINK PCIe-GIE64 - Acquisition card GigE Vision PoE+ Frame Grabber
  • ADLINK M-302 - Industrial control motherboard ATX PC Board Mainboard
  • ADLINK PCI-8134 - Motion Controller PCI Card 4-Axis Controller Board
  • ADLINK PCI-RTV24 - Image capture card Analog Video Frame Grabber
  • ADLINK PCI-8102 - Motion control card 2-Axis Servo & Stepper Controller Board
  • ADLINK PCI-9112 REV.B1 - Card Multi-Function Data Acquisition Card
  • ADLINK HSI-DI32-M-N / HSL-TB32-M-DIN - Discrete I/O MODULE Distributed Automation Module System
  • ADLINK PCI-7296 - IO card REV.A3 96-CH Parallel Digital I/O Card
  • ADLINK DIN-814P-A4 / 814Y - terminal board Motion Control Interface Block
  • ADLINK DIN-814P-A4 - 51-14056-0A10 PCB-I-E-2736=ZA01 Screw Terminal Board Breakout
  • ADLINK M-322 - motherboard Industrial Control Computer Mainboard
  • ADLINK NUPRO-406 REV:B1 - industrial control motherboard Full-Size PICMG CPU Board
  • ADLINK AMP-204C - card DSP-Based 4-Axis Advanced Pulse-Train Controller
  • ADLINK HPCI14S REV.B1 - industrial computer baseboard 14-Slot Passive Backplane
  • ADLINK PCI-7250 - 8-CH Relay Output & 8-CH Isolated DI PCI Card
  • ADLINK EBP-13E2 - baseplate Passive Backplane Industrial Computer Chassis Board
  • ADLINK LPCI-3488A - PCI-GPIB card 51-12801-0A30 acquisition card IEEE-488 Interface Board
  • ADLINK PCI-6216V-GL - 51-12201-0C30 16-CH 16-Bit Voltage Analog Output Card
  • ADLINK ACL-8454 - 16-CH Isolated Digital I/O & 4-CH Counter Card
  • ADLINK HPCI-9S7U - backplane Passive Backplane Compatible with NuPRO-A301 852 841 842
  • ADLINK DAQ-2010-007 - Simultaneous-Sampling Multi-Function Data Acquisition Card
  • ADLINK MP-C154 - 51-64205-0A10 Motion Control Card 4-Axis Controller Board
  • ADLINK MXE-202/mSSD16B/WiFi-BT - Matrix Rugged I/O Platform Embedded Fanless Computer
  • ADLINK CM-920-R-17 - PC/104-Plus Single Board Computer Module Intel Celeron M
  • ADLINK PCI-7250 NSMP - 8-CH Relay Output & 8-CH Isolated DI Card
  • ADLINK PCI-8164 - 4-Axis Motion Controller PCI Card W/ Cable and Breakout Box
  • ADLINK EMX-100 - Ethernet-based 4-axis Motion Controllers Distributed Motion Module
  • ADLINK PCI-8134A - Press control card 4-Axis Motion Controller Board
  • ADLINK M-845EG REV:3.2 - industrial motherboard Pentium 4 Socket 478 Micro-ATX
  • ADLINK PCI-9114A Rev A2 DG - card High-Resolution Multi-Function Data Acquisition Board
  • ADLINK IEC-915GV - REV 1.1 Industrial motherboard Socket 478 CPU Board
  • ADLINK PCI-9111DG(G) - Data Acquisition Card Multi-Function DAQ Card
  • ADLINK HPCI-15S10 REV:B2 - Industrial computer base plate Passive Backplane Board
  • ADLINK NuPR0-840 / NuPR0-840DV - industrial control motherboard Full-size PICMG CPU Board
  • ADLINK RTV-24 / PCI-MP4S - 51-12519-1C30 4-Channel Real Time Video Capture Board
  • ADLINK NUPRO-780 - industrial control motherboard Pentium III Single Board Computer
  • ADLINK PCI-7296 - 0050 card 96-CH Opto-Isolated Parallel DIO Card Set
  • ADLINK NUPRO-780 - industrial control motherboard PICMG Full-Size SBC
  • ADLINK PCI-7248 - 51-12006-0A3 002 Pci 7248 48-CH Parallel Digital I/O Card
  • ADLINK PCI-7230 - 32-CH Isolated Digital I/O Card
  • ADLINK AMP-204C - motion control card 4-Axis Advanced Controller Board
  • ADLINK PCI-1714UL - Card Ultra High-Speed 4-CH Simultaneous Sampling DAQ
  • ADLINK NuPRO-E330 - industrial computer equipment motherboard PICMG 1.3 SHB SBC
  • ADLINK AMP-204C - DSP-Based 4-Axis Advanced Pulse-Train Motion Controller Module
  • ADLINK PCI-7256 - 001 51-12206-0A2 REV.A2 LPCI-7256 16-CH Latching Relay Output Card
  • ADLINK ND6050 - NUDAM DIGITAL I/0 MODULE Distributed I/O Unit
  • ASEM BM100 - Box PC Embedded Fanless Industrial Computer
  • ADLINK PCI-7250 - PCI Acquisition Card 8-CH Relay Output & Isolated DI Board
  • ADLINK PCI-8164 - Servo motion control 4-Axis Controller Card
  • ADLINK NuPRO-A40H - Industrial Motherboard 51-41807-1A30 OSP LGA1155 H61
  • ADLINK ADMAX X300 SERVER - 51066010-0A30 motherboard Multi-Processor Mainboard
  • ADLINK CMe-GIE62+ - 51-32903-0A30 control card PC/104-Plus GigE Vision Frame Grabber
  • ADLINK NUPRO-780 - industrial control motherboard Full-Size PICMG SBC CPU Board
  • ADLINK ETX-AT-N270-18/GKTEL - 51-71111-OB10 motherboard ETX CPU Module Board
  • ADLINK DIN-812M - interface module Terminal Block Connection Board
  • ADLINK IMB-M42H - industrial control motherboard LGA1155 Micro-ATX Mainboard
  • ADLINK PXIS-2508 - 8-slot 3U PXI Instrument Chassis Power Hardware Assembly
  • ADLINK AMP-208C - Motion Control card DSP-Based 8-Axis Pulse-Train Controller
  • ADLINK PCI-9111 / PCI-9111DG - Multi-Function Data Acquisition Card DAQ Board
  • ADLINK IEEE-488 GPIB card - Bus Interface Controller Communication Board
  • ADLINK RTV-24 - 51-12519-1C30 image acquisition card Video Frame Grabber Card
  • ADLINK TB-24P/24-01 - Board 24 Way Screw Terminal Breakout Board
  • ADLINK HSL-DI16DO16-DB-NN - 51-23015-0A40 Distributed Discrete I/O Module Set
  • ADLINK PCI-7442 - switch quantity card data acquisition card 64-CH Isolated Card
  • ADLINK ACL-7130 REV. B2 - industrial control capture card Isolated Digital I/O PCI Card
  • ADLINK PCI-6S / PCI6S - Backplane 6-Slot Passive Backplane Chassis Board
  • ADLINK ACL-8113A - card Isolated Digital Input Card
  • ADLINK CPCI-6208V-003 - board cPCI CompactPCI 8-CH Analog Output Card
  • ADLINK DIN-100S-01(G) - SCSI 100-Pin Terminal Block Interface Board
  • ADLINK PCI-7433 - Isolated Digital Input Card 64-CH
  • ADLINK PCI-9812 - Synchronous sampling analog input card High-Speed DAQ Board
  • ADLINK PCI-7434 REV.B1 - PLOTECH PCB-I-E-1182=6EX2 64-CH Isolated Digital Output Card
  • ADLINK PCIe-RTV24 - 51-18016-0A20 4-CH Real-Time Video Capture Card PCIe Frame Grabber
  • ADLINK PCI-8144 / PCI-8144N - Motion control card 4-Axis Stepper Motor Controller
  • ADLINK DIN-68S-01 - terminal board 68-Pin Connector Terminal Block
  • ADLINK MP-C154 - Motion control card 4-Axis Advanced Controller Card
  • ADLINK PCI-7248 (G) - Motherboard 48-CH Parallel Digital I/O Card
  • ADLINK MXE-1301(G) - Intel Atom D2550+NM10 MXE 1300 Series 93-4130-0030 Embedded Computer
  • ADLINK PRO-841 Rev 2.0 / PRO-060907000670 - CPU 2.26GHz & RAM Industrial PC Board
  • ADLINK NuPRO-E330 - Industrial Motherboard System Host Board PICMG 1.3 SHB
  • ADLINK EBP-13E2 - Passive Backplane Industrial Chassis Baseboard
  • ADLINK PCI-8154 - 4-axis Motion Control Card Servo & Stepper Controller Board
  • ADLINK NuPrO-596 REV.B1 - industrial control motherboard Half-size PICMG CPU Board
  • ADLINK PCI-7852 / PCI-7851 - PLOTECH High-Speed Link Control Card Interface Board
  • ADLINK PCI-9112 - 51-12252-0D20 data acquisition card Multi-Function DAQ
  • ADLINK PCI-9112 - Circuit Board 51-12252-0C20 Multi-Function Data Acquisition Card
  • ADLINK NUPRO-761 REV:1.1 - industrial control motherboard PICMG Full-Size CPU Board