ABB 3HNE00313-1 teach pendant
Current ratings - IEC non regenerative converters (S01)This unit type can be used as large field exciter. Do not forget the SDCS-DSL-H10 (+S521).
A 10 % current de-rating is strongly recommended.
1190 ADC for 35°C and 1140 ADC for 40°C ambient temperature. As option.
Note:
AC current IAC = 0.82 * IDC
Standard duty cycles
Unit type IDC I IDC II IDC III IDC IV Size Internal
field current
2-Q converters continuous
100 %
15 min
150 %
60 s
100 %
15 min
150 %
120 s
100 %
15 min
200 %
10 s
400 V / 500 V (IEC) / 525 V (UL) [A] [A] [A] [A]
DCS880-S01-0020-04/05 20 16 24 16 24 15 30 H1 0.3 ... 6 A
DCS880-S01-0045-04/05 45 36 54 35 52 31 62 1 ... 12 A
DCS880-S01-0065-04/05 65 54 81 52 78 49 98
DCS880-S01-0090-04/05 90 76 114 74 111 73 146
DCS880-S01-0135-04/05 135 105 157 100 150 93 186 H2 1 ... 18 A
DCS880-S01-0180-04/05 180 130 195 125 187 110 220
DCS880-S01-0225-04/05 225 170 255 165 247 148 296
DCS880-S01-0270-04/05 270 200 300 195 292 180 360
DCS880-S01-0315-04/05 315 240 360 235 352 215 430 H3 2 ... 25 A
DCS880-S01-0405-04/05 405 310 465 300 450 270 540
DCS880-S01-0470-04/05 470 350 525 340 510 310 620
DCS880-S01-0610-04/05 610 455 682 435 652 425 850 H4 2 ... 30 A
DCS880-S01-0740-04/05 740 570 855 540 810 525 1050
DCS880-S01-0900-04/05 900 680 1020 650 975 615 1230
DCS880-S01-1190-04/05 1190 860 1290 835 1253 745 1490 H5 25 A
+S164 DCS880-S01-1200-04/05 1200 888 1332 872 1308 764 1528 H6
DCS880-S01-1500-04/05 1500 1200 1800 1156 1734 1104 2208
DCS880-S01-2000-04/05 2000 1479 2219 1421 2132 1361 2722
DCS880-S01-2050-05 2050 1550 2325 1480 2220 1450 2900 H7 -
DCS880-S01-2500-04/05 2500 1980 2970 1880 2820 1920 3840
DCS880-S01-3000-04/05 3000 2350 3525 2220 3330 2280 4560
DCS880-S01-3300-04/05 3300 2416 3624 2300 3450 2277 4554 H8 -
DCS880-S01-4000-04/05 4000 2977 4466 2855 4283 2795 5590
DCS880-S01-5200-04/05 5200 3800 5700 3669 5504 3733 7466
600 V / 690 V
DCS880-S01-0290-06 290 240 360 225 337 205 410 H3 -
DCS880-S01-0590-06 590 470 705 472 708 434 868 H4 -
DCS880-S01-0900-06/07 900 684 1026 670 1005 594 1188 H6 25 A
+S164 DCS880-S01-1500-06/07 1500 1200 1800 1104 1656 1104 2208
DCS880-S01-2000-06/07 2000 1479 2219 1421 2132 1361 2722
DCS880-S01-2050-06/07 2050 1520 2280 1450 2175 1430 2860 H7 -
DCS880-S01-2500-06/07 2500 1940 2910 1840 2760 1880 3760
DCS880-S01-3000-06/07 3000 2530 3795 2410 3615 2430 4860
DCS880-S01-3300-06/07 3300 2416 3624 2300 3450 2277 4554 H8 -
DCS880-S01-4000-06/07 4000 3036 4554 2900 4350 2950 5900
DCS880-S01-4800-06/07 4800 3734 5601 3608 5412 3700 7400
800 V
DCS880-S01-1900-08 1900 1500 2250 1430 2145 1400 2800 H7 -
DCS880-S01-2500-08 2500 1920 2880 1820 2730 1860 3720
DCS880-S01-3000-08 3000 2500 3750 2400 3600 2400 4800
DCS880-S01-3300-08 3300 2655 3983 2540 3810 2485 4970 H8 -
DCS880-S01-4000-08 4000 3036 4554 2889 4334 2933 5866
DCS880-S01-4800-08 4800 3734 5601 3608 5412 3673 7346
990 V
DCS880-S01-2050-10 2050 1577 2366 1500 2250 1471 2942 H8 -
DCS880-S01-2600-10 2600 2000 3000 1900 2850 1922 3844
DCS880-S01-3300-10 3300 2551 3827 2428 3642 2458 4916
DCS880-S01-4000-10 4000 2975 4463 2878 4317 2918 5836
1190 V Data on request

Control board SDCS-CON-H01 (H1 ... H8)
The control circuit terminals are common for all sizes H1 … H8.
Location of the control circuit board SDCS-CON-H01
The SDCS-CON-H01 is mounted on an electronic tray. The electronic tray is attached in the housing by means of
two hinges.
Watchdog function
The SDCS-CON-H01 has an internal watchdog. The watchdog controls the proper function of the
SDCS-CON-H01 and the firmware. If the watchdog trips, it has the following effects:
– The thyristor firing control is reset and disabled.
– All DI’s will not be processed.
– All DO’s are frozen in the actual state.
– All AI’s will not be processed.
– All programmable AO’s are frozen in the actual state.
Recommended wire size - Tightening torques
Control cables:
Wire sizes: Tightening torques:
0.5 … 2.5 mm2 (24 … 12 AWG) 0.5 Nm (5 lbf·in) for both stranded and solid wiring
XAI: Reference voltages and analog inputs
XAO: Analog outputs
XD2D: Drive-to-drive link
The drive-to-drive link is a daisy-chained RS-485 transmission line that allows basic master-follower
communication with one master and multiple followers. It is also used for the embedded fieldbus.
Set the termination switch J3 (see Jumpers and switches) next to terminal block XD2D to terminated ( ) at
the two physical ends of the drive-to-drive link. All intermediate switches have to be set to not terminated
( ).
Use double shielded twisted-pair cable ( 100 , for example, PROFIBUS compatible cable) for the wiring. For
best immunity, high quality cable is recommended. Keep the cable as short as possible. The maximum complete
length of the link is 50 meters. Avoid unnecessary loops and running the link near power cables.
+VREF +10 VDC, ±1 %
RL = 1 … 10 k
Maximum wire size 2.5 mm2
-VREF -10 VDC, ±1 %
RL = 1 … 10 k
Maximum wire size 2.5 mm2
AI1+ ±10 V [Rin 200 k], 0 (4) ... 20 mA or ±20 mA [Rin = 100 ] depending on J1
Maximum wire size 2.5 mm2
Differential inputs, common mode range ±30 V
Sampling interval per channel: 0.25 ms
Hardware filter: 0.25 ms
Resolution: 15 bit + sign
Inaccuracy: 1 % of full scale range
AI1-
AI2+ ±10 V [Rin 200 k], 0 (4) ... 20 mA or ±20 mA [Rin = 100 ] depending on J2
Maximum wire size 2.5 mm2
Differential inputs, common mode range ±30 V
Sampling interval per channel: 0.25 ms
Hardware filter: 0.25 ms
Resolution: 15 bit + sign
Inaccuracy: 1 % of full scale range
AI2-
AI3+ ±10 V [Rin 200 k]
Maximum wire size 2.5 mm2
Differential inputs, common mode range ±30 V
Sampling interval per channel: 0.25 ms
Hardware filter: 0.25 ms
Resolution: 15 bit + sign
Inaccuracy: 1 % of full scale range
AI3-
Parameter settings see DCS880 Firmware manual Group 12 Standard AI