K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

LCD monitor upgrade for 14 inch Xycom 9450 and Xycom 9403 control with cable kit

From: | Author:Wang | Time :2025-05-29 | 553 visit: | 🔊 Click to read aloud ❚❚ | Share:

LCD monitor upgrade for 14 inch Xycom 9450 and Xycom 9403 control with cable kit

Overview

The Xycom 9450 and 9403, as important equipment in the industrial control field, may experience issues such as blurry display and interface aging with their original 14 inch LCD displays after long-term use. The upgrade of the cable kit this time aims to meet the modern industrial demand for efficient visual monitoring and precise data exchange by improving display resolution, enhancing color expression, and optimizing interface connection stability, ensuring the continuous and stable operation of equipment in complex industrial environments.


Specification parameters

(1) Display parameters

Resolution: 1280 × 1024

Compared to the original monitor, the screen details are clearer, and the edges of text and images are smoother, making it suitable for displaying complex industrial drawings, fine data charts, and reducing the risk of information misreading

Brightness: 300cd/m ²

Even in industrial workshops with strong lighting, it can ensure clear and visible screen content, reduce the interference of reflection on the operator's line of sight, and improve work efficiency

Contrast ratio: 1000:1

Make the bright parts of the screen brighter and the dark parts darker, and make the color differentiation of equipment operation status indicator lights, alarm prompts, etc. more prominent, making it easier to quickly identify abnormal situations

Display ratio: 4:3

Adapt to the original interface layout of Xycom 9450 and 9403, without the need for significant adjustments to device software display settings

Response time: 5ms

Effectively reducing dynamic image ghosting, the image is smooth and free of ghosting when the monitoring device is running quickly

(2) Cable kit parameters

HDMI cable

Length: Available in two specifications: 1.5 meters and 3 meters. 1.5 meters is suitable for compact installation scenarios of equipment, such as inside small control cabinets; 3 meters can meet the layout requirements of devices with long distances between them, such as connecting devices and displays installed in large workshops.

Transmission standard: Complies with HDMI 1.4 standard, supports 1080p high-definition video transmission, with a data transmission rate of 3.4Gbps, ensuring no delay or lag in image transmission, and realizing real-time high-definition monitoring of industrial production processes.

Material: Made of pure copper conductor and multi-layer shielding design, it can effectively resist electromagnetic interference in industrial environments, such as interference caused by motor operation and frequency converter operation, ensuring stable signal transmission and avoiding problems such as snowflakes and flickering on the screen.


VGA cable

Length: 2 meters standard length, suitable for most industrial equipment conventional installation distances, meeting the basic connection requirements between Xycom 9450 and 9403 and displays.

Interface type: Both ends are DB-15 male heads, using gold plating technology, with strong oxidation and corrosion resistance, low contact resistance, ensuring stable and reliable signal transmission, extending cable service life, and reducing the probability of display failures caused by poor interface contact.


Core functions

(1) High definition visualization upgrade

The upgraded monitor, with high resolution and excellent color performance, can clearly present industrial equipment operating parameters, real-time production process images, and complex engineering drawings. For example, in a machining workshop, parameters such as machine speed and feed rate can be clearly displayed; In chemical production monitoring, it can accurately present the pressure and temperature change curves of pipelines, helping operators to more accurately grasp the operating status of equipment, timely discover potential hazards, and provide reliable basis for production decisions.

(2) Flexible and stable connection

The cable kit offers a wide range of interface types (HDMI and VGA) and diverse length specifications, supporting flexible connection between the monitor and Xycom 9450, 9403, and other different types of industrial equipment. For old devices that are still using traditional VGA interfaces, stable connections can be achieved through VGA cables; For newly purchased high-performance industrial computers and other devices with HDMI interfaces, HDMI cables can achieve fast transmission of high-definition digital signals, improving device versatility and system integration. At the same time, the shielding design and high-quality interfaces of high-quality cables ensure stable and uninterrupted signal transmission in complex industrial electromagnetic environments.

(3) System compatibility optimization

This upgrade plan fully considers the system characteristics of Xycom 9450 and 9403, retaining the VGA interface to ensure compatibility with the original device system, making it convenient for users to gradually upgrade their devices without replacing all hardware, reducing costs and resource waste. At the same time, the newly added HDMI interface can adapt to the digital and intelligent upgrading needs of future devices, achieving a smooth transition between old and new devices.


Working principle

The upgraded monitor receives video and data signals from Xycom 9450 and 9403 devices through HDMI or VGA interfaces. The digital signal transmitted by HDMI cable can be directly received and processed by the digital processing chip of the display, quickly converted into high-definition images and displayed on the screen; The analog signal transmitted by VGA cable first goes through the A/D conversion module inside the display, which converts the analog signal into a digital signal. Then, the digital processing chip performs color correction, image scaling, and other processing to finally display a clear image. During cable transmission, its shielding layer effectively blocks external electromagnetic interference, while the anti-interference circuit inside the display further filters out clutter, ensuring signal integrity and accuracy, and achieving stable and high-definition display effects.


Upgrade Operation Guide

(1) Preparation work

Confirm that the Xycom 9450 and 9403 devices have been completely powered off, and turn off the power supply of related supporting equipment to avoid the risk of electric shock or equipment damage during operation.

Prepare the installation tools required for the upgrade, including a 14 inch LCD upgrade monitor, cable kit, screwdriver, anti-static wristband, etc. Wear anti-static wristbands to prevent damage to electronic components caused by human static electricity.

(2) Disassemble the original monitor

Use a screwdriver to unscrew the screws that secure the original monitor, carefully remove the monitor casing, and be careful to preserve the screws and casing components.

Carefully disconnect the cables connecting the original monitor to the Xycom 9450 and 9403 devices, remember the connection position and interface type of each cable, and take photos or record annotations for future reference when installing a new monitor.

(3) Install a new monitor

Place the new monitor in its original installation position and secure the monitor housing with screws to ensure a secure installation. Tighten the screws appropriately to avoid damaging the monitor housing due to excessive tightness or loosening during device vibration.

Choose the appropriate cable (HDMI or VGA) based on the interface type of the Xycom 9450 and 9403 devices. If the device has an HDMI interface, prioritize using an HDMI cable. Connect one end of the cable to the device's HDMI interface and the other end to the monitor's HDMI interface; If the device only has a VGA interface, use a VGA cable for connection to ensure that the interface is tightly connected without looseness or skewness.

(4) Testing and Debugging

Connect the Xycom 9450, 9403 devices and monitor power, turn on the devices and monitor in sequence, and check if the monitor is displaying the image normally.

If the display is abnormal, first check whether the cable connection is correct and the interface is secure, and try unplugging the cable again; If the problem still persists, you can try replacing the cable for testing or checking if the device display settings are correct.

Enter the monitor settings menu and adjust parameters such as resolution, brightness, contrast, color mode, etc. according to actual needs to achieve the best display effect. At the same time, test whether the various functions of the monitor, such as menu operation and button response, are normal.


Precautions

(1) Installation and use

During the installation process, it is strictly prohibited to pull or tug on the cable with force to avoid internal conductor breakage or interface damage, which may affect the signal transmission performance. If the cable length is not suitable, do not forcefully stretch or bend it. Choose a cable of appropriate length for installation.

Do not use the monitor in harsh environments such as high temperatures (over 60 ℃), humidity (relative humidity greater than 85%), and strong magnetic fields (such as near large motors or transformers). If it is unavoidable to use in special environments, corresponding protective measures should be taken, such as installing a cooling fan, protective casing, and using shielding devices for the monitor.

Regularly check the connection of cables, especially after the equipment has been running for a period of time, as cables may become loose or fall off due to vibration or other reasons. Conduct a comprehensive inspection at least once a month to ensure a stable and reliable connection between the device and the monitor.

(2) Maintenance and upkeep

When cleaning the monitor screen, a dedicated screen cleaning cloth and cleaner should be used. First, gently wipe the surface of the screen to remove dust and stains. Avoid using rough fabrics or cleaning agents containing corrosive ingredients to prevent scratching the screen or damaging the screen coating. The cleaning frequency depends on the usage environment and frequency, generally cleaning once every 1-2 weeks.

Regularly dust the monitor by using dry compressed air or a soft bristled brush to clean the dust from the cooling holes, interfaces, and other parts of the monitor. Deep dust removal should be carried out every 3-6 months to maintain good heat dissipation and electrical connection performance of the equipment, prevent overheating and poor interface contact caused by dust accumulation, and extend the service life of the monitor.

LCD upgrade kit for Xycom 2050 | T2 Industrial Xycom 2050 LCD


  • Beckhoff CX5020-0112 - PLC Module
  • Beckhoff CP2912-0000 - Control Panel
  • Beckhoff C6920-1047-0030 - industrial control cabinet control PC
  • BECKHOFF CX1020-0121 - CPU Module Power Supply Setup
  • Beckhoff EL6752 - DeviceNet Master EtherCAT Terminal
  • Beckhoff IP1002-B518 - Fieldbus Box Module
  • Beckhoff CP6606-0001-0020 - 7 inch Economy Panel PC incl. Connection Cable
  • Beckhoff CX5010-0111 - Controller Module
  • BECKHOFF AX2020-S62000-520 - SERVO DRIVE 5.76
  • Beckhoff EL1904 - 4-Channel Digital Input Module
  • BECKHOFF AX5201-0000 - Servo Drive
  • Beckhoff CP7201-1000-0000 - Industrial PC with Touch Screen
  • Beckhoff BK7350 - module Bus Coupler
  • BECKHOFF C6930-0010 - PLC PC Industrial PC
  • Beckhoff AX5125-0000 - Servo Amplifier
  • Beckhoff CX2100-0914 - Power Supply for External UPS for CX20xx
  • Beckhoff CP6608-1000-0010 - Control Panel
  • Beckhoff EL7221-9014 - EtherCAT Terminal, 1 Channel Motion Interface, 48 V DC
  • BECKHOFF CP2919-0000 - Multitouch Built-In Control Panel 24VDC 19"
  • BECKHOFF C6015-0010 - TWINCAT2 Single Core 1.46GHz Industrial PC
  • Beckhoff CU8803-0000 - Controller Module Transmitter
  • BECKHOFF CU1521-0000 - EtherCAT media converter
  • Beckhoff CX5140-0111 - Control Embedded PC HW 3.1 + Flash Card CX2900-0028 4GB
  • Beckhoff AX2513-B200 - Servo Amplifier Servodrive
  • Rexroth MSK061C-0600-NN-M1-UP1-NNNN - Engine Servo Motor
  • Beckhoff AM3031-0C01-0000 - Servo Motor
  • BECKHOFF CP7201-1000-0000 - Industrial PC with touch screen
  • BECKHOFF C6925-0000 - PLC Module Industrial PC
  • BECKHOFF EL5151-0021 - PLC module Encoder Interface
  • Beckhoff CX5130-0125-1001 - Module Embedded PC
  • BECKHOFF EP3356-0022 - EtherCAT Box Module
  • BECKHOFF AX5203-0000 - SERVO DRIVE
  • B&R X20IF1082 - COMMUNICATION INTERFACE MODULE POWER LINK
  • BECKHOFF EL7342 - PLC Module 2-Channel DC Motor Output
  • BECKHOFF CX8190 - Ethernet Controller
  • BECKHOFF CX2020-0120/4GB - CPU CX2100-0904 3x EL6900 EL1904 16GB RAM
  • Beckhoff CX5130-0112 - Module Embedded PC
  • Beckhoff CP7701-0001-0020 - Panel-PC Touch Panel 12" ELO Accutouch AMD ALX 500MHz
  • BECKHOFF CX5020-0111 - Embedded PC Controller
  • Beckhoff CX2040-0100 - Embedded PC HW: 4.0 + CX2100 0014 + 4GB CFast Card
  • Beckhoff CP6512-0001 0030 - Control Panel
  • beckhoff CX9020-0111-0900 - Controller Modules
  • Beckhoff IE3112 - Module Fieldbus Box
  • BECKHOFF CX8051 - PLC Module
  • BECKHOFF CX1100-0920 - module Power Supply
  • Beckhoff CP7921-1075-0000 - Control Panel
  • B&R 3NC352.6 - PLC Module
  • Beckhoff CX8095 - module Controller
  • beckhoff CX1020-0021 - CPU controller module
  • BECKHOFF BK9103 - PROFINET BUS COUPLER
  • Beckhoff C6930-0050 - Schaltschrank-Industrie-Pc Core i7-4700 CPU+FC9062 Modules
  • Beckhoff AM8013-0DH0-1001 - Servo Motor
  • BECKHOFF EPP3184-0002 - Module EtherCAT-P Box
  • BECKHOFF AM8041-0H10-0000 - servo motor
  • BECKHOFF CX1010-0100 - Embedded PC Module System
  • beckhoff CP2916-0000 - Industrial touch screen
  • Beckhoff C6110 - Industrial PC Boser HS6237
  • Beckhoff CX1010-0111 - CPU Module Setup
  • Beckhoff EL3751 - EtherCAT Terminal 1 Channel Analog Input Multifunction 24 Bit
  • BECKHOFF AX5721-0000 - Encoder Interface Card
  • Beckhoff CX1020-0122 - module Embedded PC
  • BECKHOFF CP3921-0000 - Control Panel
  • BECKHOFF CX2040-0155 - STANDARD CPU MODULE INTEL I7 2715QE 2.1GHz
  • BECKHOFF CX5020-0111 - Controller module
  • Beckhoff AX5201-0000-0200 - servo drive
  • BECKHOFF CP2921-0000 - Multi-touch built-in Control Panel with DVI/USB
  • BECKHOFF CP3907-0000 - Touch Panel
  • Beckhoff CX5120-0115 - CPU Module
  • Beckhoff KL3361 - PLC Module Oscilloscope Terminal
  • Beckhoff CX1000-0111 - Embedded PC System Combination
  • Beckhoff AM8023-0E20-0000 - Servo motor with Tramec EP75/2 Transmission
  • beckhoff am8533-2f10-0000 - servo motor
  • BECKHOFF EL5042 - EtherCAT Terminal
  • Beckhoff CX9001-1001 - PLC Module
  • BECKHOFF CX9020-0112 - Digital Module CPU Controller
  • BECKHOFF CP6709-0001-0000 - Touchpanel
  • Beckhoff 1004B2060000 - Communication Module
  • Beckhoff CX5020-0112 - PLC Controller
  • BECKHOFF EL2904 - EtherCAT Safety Input Output Module 24V
  • Beckhoff CX2040-0142 - Embedded PC Controller Module
  • BECKHOFF AM8121-0F20-0000 - SERVO MOTOR
  • Beckhoff CX9020-0112 - CPU Module
  • BECKHOFF CB3050-0008 - PCB Motherboard Board
  • Beckhoff EK1512-0010 - PLC Module EtherCAT Junction
  • BECKHOFF CX1001-0121 - Embedded PC And CPU Basic Module Controller
  • Beckhoff C6032-0070 - Industrial PC
  • Beckhoff CX1020-0122 - Module Embedded PC
  • BECKHOFF CX8010 - Controller Module
  • BECKHOFF EK1818 - Modules EtherCAT Bus Coupler
  • BECKHOFF CX5140-0155 - PLC Embedded PC
  • BECKHOFF CX1100-0910 - Power Supply Module
  • Beckhoff CX1001-0121 - CPU Module + CX1000-C00L + CX1100-0002 + CX1000-N001
  • Beckhoff CP6801-0001-0010 - Control Panel
  • BECKHOFF BK9103-1005 - Bus Coupler PROFINET
  • Beckhoff AX5203-0000-0202 - 161336 Digital Compact Servo Amplifier 2 Channel
  • BECKHOFF CX5020-0111 - Controller module
  • BECKHOFF CP7032-1031-0010 - Cp-Link Control Panel
  • Beckhoff AX5112-0000-0200 - Servo Driver
  • Beckhoff BX8000-0000 - RS232/RS485 Bus Terminal Controller | HW:1.4
  • BECKHOFF CX2020-0120 - CPU MODULE WITH CX2100 Power Supply
  • Beckhoff EL4012 - Module EtherCAT Terminal
  • BECKHOFF CP6204-0001-0030 - ECONOMY INSTALLATION CONTROL PANEL
  • Beckhoff CP6833-0001-0011 - Built-In Control Panel-Without Control Panel Monitor
  • BECKHOFF EK1521-0000 - module EtherCAT junction
  • Beckhoff EP3314-0002 - EtherCAT Compact Box M12 4x Analog Input Thermoelements
  • Beckhoff CX8090 - PLC modules Controller
  • Beckhoff AM8033-0JG0-0000 - Servo Motor
  • Beckhoff CP9035.2 - CP9035 capture card
  • Beckhoff CP7802-1241-0010 - Industrial Touchscreen 15 Inch
  • Beckhoff BX8000-0000 - Module Bus Terminal Controller
  • BECKHOFF IE1002-0000 - Junction box
  • Beckhoff AM237S-0021 - Servomotor
  • Beckhoff EL2564 - EtherCAT Terminal, 4-channel LED output, 5-48VDC, 4A, RGBW
  • BECKHOFF EL1918 - EtherCAT Terminal 8-Channel Digital Input 24V DC
  • Beckhoff CB3052-0005 - Circuitboard Motherboard
  • Beckhoff AM8023-2E11-0000 - Servomotor
  • Beckhoff CX8190 - Ethernet Controller
  • BECKHOFF EL4038 - Module EtherCAT Terminal
  • B&R 5PC910.SX01-00 - APC910 Industrial PC | i5-6440EQ 8GB
  • Beckhoff CP9030-A002 - CP-Link Karte Version: 1.1
  • BECKHOFF BK7200 - CTNET Control Techniques Bus Coupler
  • Beckhoff CP2616-0000 - Multi-Touch Touchscreen Panel for 24V DC Automation
  • BECKHOFF LOT 31 modules - PLC Module Bundle
  • BECKHOFF EJ2889-0000 - Module EtherCAT Plug-in Module
  • BECKHOFF AM8043-0H20-0000 - Servomotor
  • BECKHOFF EL3154 - module EtherCAT Terminal
  • Beckhoff C6017-0030 - Industrial PC
  • BECKHOFF CX9020-0112 - CPU Module