K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

Beckhoff CP39xx series industrial touch control panel

From: | Author:Wang | Time :2026-06-12 | 7 visit: | 🔊 Click to read aloud ❚❚ | Share:

Beckhoff CP39xx series industrial touch control panel

Product positioning and overall characteristics

Product purpose and core capabilities

CP39xx is an industrial cantilever mounted multi touch panel, mainly used as a field operation and visualization terminal for mechanical equipment and automation systems, for parameter monitoring, command operation, and status display. According to the interface scheme, it is divided into two main models:

CP39xx-0000: equipped with DVI+USB extension interface, with a maximum signal transmission distance of 50m;

CP39xx-0010: Equipped with CP Link 4 bus interface, the maximum transmission distance can reach 100m.

Screen and configuration selection

The entire series adopts PCT projection type multi touch glass panel, aluminum alloy body+front glass design, with an overall front protection of IP65, which can resist water spray and dust intrusion in any direction. We offer multiple sizes and resolution specifications, covering different application scenarios: 7-inch (800 × 480), 12 inch (800 × 600), 12.1-inch (1280 × 800), 15 inch (1024 × 768), 15.6-inch (1366 × 768), 18.5-inch (1366 × 768), 19 inch (1280 × 1024), 21.5-inch/24 inch Full HD (1920 × 1080), supporting both horizontal and vertical installation display modes.

Optional extension accessories

Button Expansion Module: Multiple models can be pre installed with C9900-G02x/C9900-G05x series button expansion units, suitable for physical button+touch combination operation needs;

Mechanical accessories: tool tray (for placing keyboards and tools), aluminum alloy handle, all of which are original factory optional components;

Cantilever adapter: compatible with Rittal and Rolec standard 48mm cantilever tubes, supporting rotation and pitch adjustment;

External USB interface, dedicated connection cable, adapter box and other supporting accessories to meet the needs of peripheral expansion.

airframe structure

The whole machine has a front touch display screen, integrated interface module on the back, cantilever installation position, and optional expansion interface; The interface area is equipped with a detachable cover plate, and cantilevered cables can be stored in pipes and cable trays, with neat wiring and protection against cable bending and wear.


Detailed interface definition and communication scheme

CP39xx is divided into two major hardware versions, with clear distinctions in interface configuration, wiring rules, and transmission schemes. At the same time, it is uniformly equipped with a 24VDC power supply interface.

Universal power supply interface (shared across the entire system)

Adopting a 4-core M12 circular socket, pin 1/4 is+24V, 2/3 is GND, and the rated current of the interface is 16A. The maximum compatible cable diameter is 4 × 0.75mm ²; The voltage drop of the circuit must be strictly controlled, and the input voltage of the panel must not be lower than 22VDC, otherwise abnormal operation may occur. The power supply circuit must be equipped with UL248 standard, maximum 4A fuse, and the power supply must be NEC Class 2 isolated 24V DC power supply.

CP39xx-0000 (DVI+USB Extended Edition)

DVI Extended Interface: a dedicated extended video interface with a built-in signal restoration chip to compensate for signal attenuation caused by long-distance transmission. It can be transmitted up to 50m with a dedicated cable and defines complete TMDS signal, DDC, 5V power supply, hot plug detection, and other pins;

USB Extended Interface: A dedicated interface for USB signal extension, based on Class 5 cable transmission, without network protocol, cannot be connected to external switches/hubs, with a maximum transmission distance of 50m, enabling long-distance extension of USB peripheral signals such as keyboard and mouse.

CP39xx-0010 (CP Link Version 4)

Equipped with an 8-core M12 specification CP Link 4 interface, this bus can simultaneously transmit DVI video and USB 2.0 signals, with a maximum transmission distance of 100m. It provides two switching solutions:

CU8802 adapter box: dual cable solution, the adapter box and panel are independently powered, and the panel must be connected to an external 24V power supply;

CU8803 adapter box: single cable power supply+signal integration solution. It is strictly prohibited to connect external power to the panel, otherwise it will cause hardware burnout.

Optional external USB interface

IP65 protection waterproof USB-A interface, with anti loss screw cap, supports USB 2.0 protocol, can be connected to external devices such as USB flash drives, keyboards, mice, printers, etc. It is available in two installation forms: adapter integrated and body side mounted.

Equipment nameplate

The nameplate indicates the equipment model, version, serial number, production date, screen specifications, touch model, power supply parameters, and CE, FCC, UKCA certification information. The serial number is an important basis for equipment after-sales and spare parts matching.

Installation, wiring and wiring specifications

Transportation and Storage

The internal screen and touch components of the device have weak resistance to impact and temperature difference, and must be transported in original factory packaging; After transportation across temperature zones, it is necessary to let it stand at room temperature. If condensation occurs, it must wait for more than 12 hours before powering on. Storage temperature range -20 ℃~+65 ℃, working environment humidity ≤ 95% RH (no condensation).

Installation requirements for cantilever

Suitable for standard 48mm cantilever pipes, with a diameter tolerance range of -0.1mm to+0.8mm for the pipe body;

The cantilever adapter supports ± 165 ° rotation and ± 20 ° pitch adjustment, with clear torque requirements for installation screws (M6 screw 6Nm, pipe body fastening screw 3Nm, slotted nut 20Nm);

The installation position should avoid direct sunlight to ensure the viewing angle of the screen and device heat dissipation.

Cable wiring rules

The cables need to be threaded into cantilever tubes and dedicated cable trays, and the power and signal lines should be arranged in different zones. They should be fixed with zip ties to prevent the cables from being pulled or worn out when the equipment rotates or tilts;

Models with button expansion, the button cables are connected to the cable tray through M20 gland or 19 pin connectors, and the two wiring methods correspond to different accessory models;

All cable bending angles should not be too large, and bending resistant cables should be preferred for long-term moving parts.

Grounding specifications

The equipment must be equipped with both protective grounding and functional grounding, with a recommended grounding wire diameter of ≥ 4mm ². The PE on the cabinet side should maintain an equal potential with the power supply at 0V, in accordance with EN 60204-1 standard. Good grounding can prevent electric shock, suppress electromagnetic interference, and ensure EMC performance (in accordance with EN 61000-6-2/EN 61000-4 series standards).

Wiring and power on process

Strictly follow the sequence of wiring first, then connecting data lines, and finally connecting power supply; Do not plug or unplug any interfaces during thunderstorms. When connecting external devices with power supply, it is necessary to ensure that both parties have a potential of 0V and PE to avoid potential difference damage to the interface.


Operation, maintenance and upkeep

Guidelines for using touch screens

Only operate with bare hands or dust-free soft gloves, and do not touch the screen with hard objects; Special dust-proof and scratch resistant protective film can be pasted, and the film should be operated in a dust-free environment to avoid bubbles and impurities. The device comes with a built-in cleaning mode that can be activated using the Beckhoff Display Control tool (lasting 5-120 seconds). Once activated, it can be touch locked for easy screen cleaning.

Daily cleaning

Allow the use of glass cleaners, alcohol, and light solvents;

It is strictly prohibited to use abrasives, corrosive cleaning agents, high-pressure water guns, compressed air, and steam cleaning to avoid damaging the IP65 protective layer and touch glass;

During cleaning, the device can be kept powered on by simply locking the touch function.

Regular operation and maintenance

Regularly check the cable fixing status and cantilever fastening screws to prevent loosening;

Check the integrity of the interface waterproof cap and sealing strip to ensure the protection level;

A small number of bad pixels on the screen are within the normal production range and cannot be used as a basis for malfunction.


Dismantling and scrapping treatment

Power off and disassembly: First cut off the external 24V power supply, remove the power and data cables in sequence, loosen the cable tie and cable tray cover, and then disassemble the cantilever tube and adapter; When disassembling the cantilever nut, it is necessary to take protective measures to prevent the panel from falling.

Accessory disassembly: Tool trays, handles, and other accessories can be disassembled and assembled using the bottom M5 screws.

Scrap requirements: Strictly follow local electronic waste recycling regulations, classify and dispose of metal, plastic, circuit boards and other components.


Troubleshooting

Manual compilation of typical fault phenomena, causes, and corresponding solutions:

The device is completely inactive: priority should be given to checking the 24V power supply, fuses, and power cord connections. If there are still abnormalities, contact Beifu after-sales service;

Screen black/intermittent lighting: Check for backlight components and internal hardware faults, need to return to the factory for maintenance;

Touch malfunction: Focus on checking whether the grounding function is reliable. Operators need to wear regular shoes and socks to ensure normal grounding of the human body;

USB communication abnormality (TwinCAT environment): Adjusting the system task cycle from the default 10ms to 50-80ms can solve it.


Core technical parameters

Power supply: 22-30VDC (nominal 24VDC, NEC Class 2);

Protection level: The front panel is IP65, and the interface area is sealed and protected by a cover plate;

Mechanical performance: Vibration complies with EN 60068-2-6, impact 5G/30ms (EN 60068-2-27);

Environmental temperature: working 0 ℃~+55 ℃, storage -20 ℃~+65 ℃;

Humidity: Maximum 95% RH, no condensation;

EMC: Radiation and anti-interference comply with EN 61000-6-4 and EN 61000-6-2 respectively;

Machine weight: Divided by screen size, ranging from 1.8kg for small screens to 8.4kg for large screens;

Certification: Standard CE and FCC, some models come with EAC, UKCA and other certifications.


  • Woodward 8272-796 - Real Power Sensor Module 115/230v-ac
  • Woodward 5463-873 - NetCon Output Module
  • Woodward 8271-567 - Load Sensor Module 120/208v-ac
  • Woodward Type UG-8 P/N 8522-300 EG - Governor R.P.M 1075-1650 With Motor Groschopp
  • WOODWARD 9905-971 REV J - LINKNET 16 CHANNEL DISCRETE INPUT MODULE
  • WOODWARD 8280-3014 - 723 PLUS DIGITAL CONTROL REV NEW
  • Woodward 505DE - Digital Control System
  • Woodward 5453-750 - Ethernet Interface FTM
  • Woodward 9907-018 Rev H - 2301A Load Sharing & Speed Control
  • WOODWARD 5420-1080 V4.3 - BOARD-PPA WITHBOX
  • Woodward b 8271-347SP - 2301 speed control
  • Woodward 9905-795 Rev B - Digital Synchronizer and Load Control
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8272-582 - Generator speed control module
  • WOODWARD 9907-247 REV K - 828 DIGITAL CONTROL UNIT
  • WOODWARD 5466-353 REV C - NETCON MAIN CHASSIS TRANSCEIVER
  • Woodward Type UG-8 P/N 8524-708 - Governor 760-1560 Governor R.P.M
  • WOODWARD 9907-247 REV K - 828 DIGITAL CONTROL UNIT
  • WOODWARD 8440-1831 REV. H - EASYGEN3000 3200-5 - WITHOUT ACCESSORIES
  • WOODWARD 8444-1002 REV G - UMT1 MEASURING TRANSDUCERS
  • Woodward 5410-312C - Digital Marine Control Printed Circuit Board
  • Woodward 9905-799 REV F - Digital Synchronizer & Load Control , V#456
  • Woodward 9907-014 - 2301A for controller
  • Woodward Type UG-8 P/N B522-446 - Governor R.P.M 500-1200
  • WOODWARD 8272-221 REV.B - DIGITAL REFERENCE UNIT
  • Woodward 8901-037 - Booster Servomotor Single
  • WOODWARD 8444-1019 REV G - UMT 1 MEASURING TRANSDUCER
  • WOODWARD 1767-367 Z21 WK 0920702 - GOVERNOR MOTOR 2700 RPM KM 58-20 K 230V
  • WOODWARD 9905-972 Rev:G - LINKNET 6 CHANNEL 4-20mA OutPut
  • Woodward E8250-501 - Actuator Governor
  • WOODWARD 5466-258 REV M - SIMPLEX DISCRETE I/O MODULE
  • WOODWARD 5501-470 REV E - NETCON CPU MODULE
  • Woodward 8406-120 rev H - egcp-2 digital control
  • Woodward 8440-1799 - Easygen-350 Rev B
  • Woodward 8440-1878 - DSLC-2 Digital Synchronizer Load Control
  • Woodward 5464-843 - Cpu Processor Module
  • WOODWARD 8440-1409 Rev. J - MFR2 MDE Synchronization & Protection MSP
  • Woodward 9907-014 - controller
  • WOODWARD 9907-173 - LOAD SHARING MODULE 120V
  • WOODWARD 8440-1831 REV. K - EASYGEN 3200-5 - WITHOUT ACCESSORIES
  • Woodward 9905-969 - LinkNet Module LinkNet 6C 4-20ma in w/24v
  • Woodward 8520-498 - Governor Type UG-8 Governor R.P.M 850-1650
  • WOODWARD 5466-257 REV.-C - NETCON 5000 MODEL REMOTE TRANSCEIVER I/O MODULE
  • WOODWARD 8800 - 1001 REV-C - DSS-2, 2 CHANNEL DIGITAL SPEED SWITCH
  • WOODWARD 5501-467 REV. C - MICRONET SIMPLEX POWER SUPPLY
  • Woodward 8273-584 - Atlas-ii Digital Control
  • Woodward 8440-1019 b - spm-d10 synchronizing system
  • Woodward CSC3SUWA REV K - CSC3SUWA Controller
  • Woodward 5441-693 Rev B - Digital I/O Module
  • WOODWARD DPG-2201-002 REV.D - Governor Onan DIGITAL SPEED CONTROLLER
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8440-1884K - GENERATOR CONTROLLER EASYGEN-2500-5 REV,K
  • WOODWARD 8404-1006 - Industrial Component
  • WOODWARD 5437-1118 - PROTECHTPS MODULE Relay Bulkhead Panel
  • Woodward 8440 1801 Rev C - Easygen-350-50B/X Genset Control Engine Generator 24VDC
  • WOODWARD 5466-348 - MODULE
  • Woodward 9905-799 REV F - Digital Synchronizer & Load Control , V#456
  • Woodward 9907-018 - 2301A Load Sharing & Speed Control Rev H
  • Woodward GM9412H918-R2 1766-039 REV E - Cruise Control Motor
  • 5466-258 WoodWard - 48 Input 24 Output Discrete I/O, (UPP)
  • WOODWARD 5484-877 - PM MOTOR 24VDC 15RPM
  • Woodward 8272-221 B - Digital Reference Unit
  • Woodward 9905-796 - Digital Synchronizer And Load Control (Rev. H)
  • WOODWARD 5441-645 REV.G - 10AMP RELAY INTERFACE 11459968
  • Woodward 9907-207 - 721 Digital Control 88-132VAC
  • WOODWARD 8272-582 - APM MOTOR CONTROL AC/DC 100~220V
  • Woodward 5464-843 - Cpu Processor Module
  • Woodward 9905-001 L - SPM-A Synchronizer 115/230V 50/60Hz 10W
  • Seg Power Protection PCK4 P/N 8445 1006 A / PCKR-MW - Protection Relay 24VDC
  • Woodward 8405-062 - Actuator
  • Woodward 5464-738 - Industrial Control System
  • Woodward CSC3HUWB - controller
  • Woodward 8272-517 - PM Motor Control 220vac
  • Woodward 8272-582 - APM Motor Control
  • Woodward LR20025 MFR1375M MFR 1 - Controlling
  • Woodward 9905-392 - Proact Driver Model III
  • WOODWARD 8250-774 - ACTUATOR/GOVERNOR
  • Woodward 505DE - Digital Control System
  • Woodward 8280-303 D - 721 Digital Control Rev.G 2.0 AMP 28 VDC
  • WOODWARD DPG-2201-002 REV NEW - DIGITAL CONTROLLER
  • WOODWARD 8272-286 - 2301A LOAD SHARING & SPEED CONTROL MODULE
  • WOODWARD 8440-1884 REV M - GENSET CONTROLLER EASYGEN-2500-5/P1
  • Woodward 9905-797 Rev. M - Digital Sync And Charge Control
  • W0ODWARD ART-01681 - IDS Communicator Control Box
  • Woodward 8273-584 - Digital Control Unit ATLAS-II REV: A 18-32VDC, 60W
  • WOODWARD 5501-470 REV E - NETCON CPU MODULE
  • Woodward 1752 1752-227 - Revision D FireFly Current Load input Engine Control
  • Woodward 8440-1877 - MSLC-2-5 Control
  • Woodward 8271468 - Generator Loading Control (Rev. D)
  • Woodward 9905-387 - Pro Act Driver Model lll (Rev. F)
  • Woodward 9905-363 - Sincronizzatore Digitale E Controllo Carico
  • WOODWARD 8272-583 - APM MOTOR CONTROL
  • WOODWARD EGCP-2 - Digital Generator Control Panel 4-20MA 5V 500HZ
  • Woodward 9905-392 - Proact Driver Model III
  • Woodward 9905-392 - Proact Driver Model III
  • Woodward 8270-007 - Load Signal Control
  • Woodward 8271-651 - Digital Speed Reference
  • WOODWARD 8440-2219 - EASYGEN-2500-5-P1-K49 GENSET CONTROLLER
  • Woodward D8271-394 - 2301 Load Sharing And Speed Control Module 20-40v-dc
  • Woodward 8200-1504 Rev:E - Peak200 Steam Turbine Control Front Panel Mount HVAC
  • WOODWARD 8444-1022 REV F - UMT 1 MEASURING TRANSDUCER
  • WOODWARD 8440-1923 A - EASYGEN-3200-5 CONTROLLER
  • WOODWARD 9907-014 - 2301A controller
  • Woodward 8272-583 - Amp Motor Control DC24V
  • Woodward 9907-147 REV N - ProTech 203 Overspeed Protection System
  • Woodward 8270-417 - 2301 speed sensor
  • Woodward 8272-583 - Amp Motor Control DC24V
  • Woodward 8934-658 - Repair Kit UG8D Governor
  • Woodward 5437-281 - analog module
  • Woodward 8440-2177 A - SPM-D2-10 Digital Synchronising Controller
  • SA-4478 EPS1000 - Speed Switch
  • Woodward 9907-014 Rev: J - 2301A Speed Control
  • Woodward 9907-026 Rev C - Load Sharing Module
  • Woodward B8271-464 H B8271464 - 2301 Speed Control
  • WOODWARD 8440-1667 REV C - SPM-D10 SYNCRONIZING UNIT
  • Woodward 8440-2082 - EASYGEN-3200XT-P1 Engine Generator Control
  • Woodward 8406-120 rev H - egcp-2 digital control
  • WOODWARD SPM-D - SYNCHRONIZING SYSTEM
  • Woodward 8271-651 - Digital Speed Reference
  • WOODWARD 8444-1074 A - MODULE
  • WOODWARD 8440-2050 Rev B - EASYGEN-3200-5 CONTROLLER
  • Woodward 8440-1613 REV E - GCP30 Genset Control Package
  • Woodward 9907-018 - Load Sharing & Speed Controller Rev H 90-240VAC
  • Woodward 5466-315 - module
  • Woodward 9905-204 Rev N - SPM-A synchronizer
  • Woodward XG2 - Protection relay
  • WOODWARD 9907-175 LOAD SHARING MODULE REV A - Load Sharing Module
  • Woodward 9907-166 REV: N - 505E Turbine Control 110V AC/DC