K-WANG



Basic Information
Scope of application: MSK full series permanent magnet three-phase synchronous servo motors (MSK030, 040, 043, 050, 060, 061, 070, 071, 075, 076, 100, 101, 103, 131, 133 machine bases); Includes standard, explosion-proof Ex version, with brake, air-cooled, liquid cooled FN version.
Personnel qualifications: Only electrical/mechanical personnel who have received professional training can carry out handling, installation, wiring, and maintenance operations.
Warning classification: DANGER (fatal serious injury), Warning (potentially fatal serious injury), CAUTION (minor injury), NOTICE (equipment damage); Comes with symbol identification for ESD static electricity, high voltage, rotating parts, strong magnetism, high temperature, etc.
Compliance standards: EN 60034-1, EN 60034-5; Satisfy mechanical instructions EMC、 Low voltage CE certification, some models have UL/CURus certification.
Safety standards
1) Electrical safety
Standard process for power-off operation: Disconnect the power supply → Lock and prevent closing → Confirm complete power-off → Grounding short circuit → Cover adjacent live parts; Reverse the sequence operation during restoration.
When the rotor of a permanent magnet motor rotates, a dangerous voltage greater than 60V will be generated at the motor terminals. It is prohibited to plug or unplug plugs or wires in the rotating state of the rotor.
It is necessary to reliably connect the protective grounding wire; It is not allowed to plug and unplug connectors with power on.
Encoders and temperature sensors are electrostatic sensitive devices, and ESD protection must be implemented during operation.
2) Mechanical safety
The 24V brake that comes with the motor cannot be used as a personal safety brake; The vertical axis must have an additional mechanical locking/external clamping mechanism to prevent falling.
Couplings, pulleys and other transmission components must be prevented from flying out, and protective covers must be installed in the operating area.
The lifespan of bearing L10 is 30000 hours, but it may be shortened due to radial and axial loads.
3) Magnetic field and human health
The motor is equipped with a strong permanent magnet; Personnel wearing pacemakers, metal implants, and hearing aids are prohibited from approaching disassembled or operating motors.
Strong magnets can demagnetize bank cards, watches, and magnetic media, keeping them away from magnetic objects; It is recommended to wear protective gloves during disassembly and assembly to prevent compression and injury.
4) High temperature safety
The operating shell temperature can reach above 70 ℃; Wait at least 15 minutes for the machine to cool down before touching.
5) Battery safety
The absolute value encoder is equipped with a built-in battery and is prohibited from charging, disassembling, or using open flames. It should be recycled as hazardous waste.
6) Prohibited Unexpected Use
It is prohibited to directly connect to the three-phase power grid and must be used in conjunction with the Rexroth IndraDrive servo drive;
The regular version is not allowed to be used in explosion-proof hazardous areas (the - xSxx explosion-proof model must be selected).
Product Introduction
1) Main technical features
Type: Three phase permanent magnet synchronous servo motor; Protection level: standard IP65, equipped with sealed air kit up to IP67;
Cooling form:
Natural convection NN: Maintain a heat dissipation gap of ≥ 100mm around the perimeter, with a maximum ambient temperature of 40 ℃;
Surface air cooling: Radial/axial fan unit, please note that the inhaled air should not contain dust, abrasives, or salt spray;
Liquid cooled FN: Closed heat exchange coolant circuit; The maximum inlet pressure is 6 bar (3 bar for old models before 2010).
Encoder selection:
S1/S2/S3: Single lap (Hiperface/EnDat2.1)
M1/M2/M3: Multi turn absolute value encoder
Brake: Optional 24 VDC ± 10% electric release type holding brake.
Bearings: Lifetime lubricated deep groove ball bearings, with fixed bearings on the B-side.
Installation form: B5 flange, B35 foot flange composite installation; Installation altitude up to 1000m.
Output shaft: optical axis, keyway shaft, cone shaft; Equipped with DIN standard center threaded holes for installing transmission components.
2) Model code and nameplate
MSK model code: machine base size - machine base length - winding - cooling - encoder - electrical interface - shaft form - brake - special version of housing;
The nameplate includes: model, serial number, weight, torque constant, insulation level, brake parameters, protection level, CE/UL identification.
3) Scope of Supply
Motor body, additional nameplate, operation manual; Options: junction box, shaft seal protection cover, cooling pipeline plug, etc. Upon arrival, the packaging and body must be immediately inspected for damage. Damaged motors are strictly prohibited from being powered on.

Transportation and Storage
1) Transportation
Original packaging must be used; Transportation temperature -20 to+80 ℃; Humidity ≤ 75%, salt spray environment is prohibited.
Do not lift the shaft or fan cover for hoisting; Use eyebolt, the eyebolt must be fully tightened; Do not stand under heavy loads.
Before transporting liquid cooled motors, the coolant must be drained to prevent low-temperature freezing and pipeline cracking.
The encoder is an electrostatic sensitive component and should be handled for ESD protection.
2) Storage
Storage conditions: -20~+60 ℃, no condensation, no salt spray, dry, dust-proof, and dark.
The checks that must be performed before powering on corresponding to the storage duration are: | Storage duration | Homework items | | ------------ | | > 1 month | Visual inspection of appearance | | > 12 months | Check for contact corrosion; Run at 800-1000rpm for 1 hour without load; measure insulation resistance; Brake polishing | |>60 months | All on top, plus replacement of bearings and encoder|
Long term storage of cables also requires visual and contact corrosion inspections; The storage of liquid cooled motors must be emptied of coolant.
Mechanical assembly
1) Flange installation
All installation holes must be used to ensure rigidity; Specify the tightening torque corresponding to grade 8.8 bolts;
Ensure alignment and avoid introducing additional radial/axial loads to the motor.
The shaft sealing ring cannot be immersed in liquid for a long time and cannot be connected to non sealed gearboxes.
2) Bottom B35 installation
The radial force of the foot structure is only allowed in the ± 15 ° direction perpendicular to the installation surface, and other directions of force will damage the bearing;
Priority should be given to flange installation. If the gear mechanism transmits lateral force, foot installation cannot be used.
3) Assembly of transmission components (couplings, pulleys)
Use a puller and heat the transmission components if necessary; It is strictly prohibited to strike the motor shaft;
The dynamic balance of transmission components must match the motor's full key balance level; Strictly adhere to the radial and axial force limits allowed by the sample.
Electrical connection
There are two electrical interface forms for motors: rotary circular plug (RLS power/RGS encoder) and junction box (RZK, RKL series).
Circular plug version
Power plug RLS, encoder plug RGS, the plug can rotate and adjust the angle (maximum rotation times not exceeding 10 times, with maximum torsional torque);
Strictly use Rexroth prefabricated cables; The plug must be plugged and unplugged in a dry and power-off state; Ensure reliable connection of PE protection ground;
Provide a complete wiring diagram, including U/V/W power lines, brake BD+BD -, PTC temperature sensor, encoder A/B/CLK/Data.
Junction box versions (RZK3100/RKL1200/RKL1300)
Support single cable and double cable parallel power output (high current scenarios); Dual wiring requires the addition of external fuses;
The specified tightening torque for each terminal; The sealing ring and sealing packing must be installed properly to maintain IP protection;
Large area grounding of shielding layer; The PE terminal must be reliably connected.
Fan unit wiring: divided into single-phase and three-phase fans, with built-in thermal protection T-version and external protection N-version.
Liquid cooling pipeline connection
Threaded interface, specifying tightening torque and screwing depth; Prohibit raw material tape and hemp thread sealing, and require O-ring axial sealing joints;
The direction of entry and exit can be interchanged; Sealing test must be conducted after assembly is completed; Regularly inspect pipelines.
Debugging and Running
Pre debugging inspection
If stored for a long time, perform pre-processing corresponding to the storage (running in, insulation, brake check);
Confirm that the power supply for the brake is 24V DC ± 10%, and test the opening and closing of the brake;
Confirm that all joints are securely fastened, transmission components are anti flying, and protective covers are in place.
Inspection items during operation
Abnormal noise and vibration;
Cleaning of motors and fans; There is no leakage in the liquid cooling pipeline;
Monitor driver alarms and temperature; Stop the machine immediately in case of any abnormality.
Maintenance, repair, and replacement of motors
Key points of maintenance cycle
The cooling fins should be cleaned at least once a year, as dust accumulation can cause overheating;
It is recommended to replace the bearings after 30000 operating hours; The shaft sealing ring should be inspected according to the working conditions for about 5000 hours and replaced if necessary;
Regularly inspect power cables and shielding grounding, replace damaged cables directly, and prohibit temporary repairs.
Repair: It is recommended to provide official service from Rexroth for components such as bearings and encoders. It is not recommended to disassemble the motor body on site.
Motor replacement process
Power off and lock; Record the position of the absolute value encoder;
Dismantle the mechanical transmission and unplug all plugs;
Replace with a motor of the exact same model;
Key point: If it is an indirect position measurement with a built-in encoder in the motor, the machine coordinate system must be reset to zero after replacing the motor.
Replace the motor to be stored: reinstall the transport protection cover; Thoroughly drain the coolant from the liquid cooled motor.
Troubleshooting Summary Table
Possible causes and solutions for the fault phenomenon
The motor does not rotate and the driver is missing; The brake is not released; Uncontrolled power supply; Driver fault check enable signal; Check the 24V power supply of the brake; Troubleshooting Drive Malfunctions
Poor alignment of vibration coupling; Unbalanced transmission components; Loosening of bolts and re centering; Rebalance; Tighten bolts according to torque
Abnormal noise and foreign objects entering the motor; Stop the machine due to bearing damage, contact the manufacturer for repair
Motor overheating alarm exceeding rated operating conditions; Heat dissipation blockage; Fan malfunction; Temperature sensor malfunction reduces load; Clean and dissipate heat; Overhaul the cooling system; Check the wiring of the sensor
Tip: For detailed performance parameters, boundary conditions, and permissible axle loads, please refer to the project planning manual. This operating manual does not provide performance curves.
Accessories and Optional Parts
Prefabricated power/feedback cables, refer to the cable selection manual;
Axial/radial air-cooled fan unit;
Sealed air kit SUP-M01-MSK/SUP-M02-MSK: used to improve the protection level of the plug part to IP67; Compressed air requires 0.1 bar ± 0.05 bar, clean, oil-free, and dry.
Environmental protection and disposal of waste
The motor contains rare earth permanent magnets, copper, and aluminum; Free return to the original factory of Lishile for recycling;
The permanent magnet rotor must be demagnetized before being scrapped; Magnetized rotors are prohibited from transportation;
Batteries are classified as hazardous waste according to local regulations for disposal; Packaging material cardboard/foam can be recycled locally.

K-JIANG
Add: Jimei North Road, Jimei District, Xiamen, Fujian, China
Tell:+86-15305925923