ABB DI801 digital input module
Operator Menus Configuration and Service Menus
FastSetUp
See 3.8
WebTension
0 N
Tension A
0 N
Tension B
0 N
PresentationMenu
See 3.12.1
SetObject
See 3.12.2
NominalLoad
ZZ kN ZZ lbs
MiscellaneousMenu
See 3.12.8
ServiceMenu
See 3.12.9
ZeroSet
See 3.12.4
TensionDiff A-B
0 N
Error and
warning messages
SetWrapGain
See 3.12.5
> 5 s
3) 1)
2)
Operator menus are described
in Section 4.7.
Error and warning messages are
described in Section 6.6.
Press for 5 seconds to go to
the first of the Configuration and
Service menus.
This menu appears if unit is set
to N/m, kN/m, kg/m or pli.
Note! Some sub menus asking
confirmation questions are not
shown in this overview. In these
menus you have to confirm that
your settings should be
performed.
VoltageOutput
See 3.12.6
5)
CurrentOutput
See 3.12.7
The fast setup can be made in two ways
depending on how the wrap gain is set.
Language, Unit, Web width4 and desired
number of decimals are set in the presentation
menu.
Select standard roll (2 load cells), single side A
or single side B measurement.
Check the nominal load on the load cell name
plate. Select nominal load from the list with
or . Confirm with .
Zero set is used to compensate for load cell
zero signal and tare weight.
Wrap gain can be determined by using hanging
weights or by calculating.
Set voltage output, filter and tension settings.
Set current output, filter and tension settings.
This menu is used to set profibus parameters
or to set factory default.
View maximum load and current offset settings
for load cell A and B. Reset maximum load
memory and offset. Simulation of load cell
signals.

Step Measurement See section
1 Check that the main supply voltage is switched off.
2 Check all cabling according to the cable diagrams. Appendix
B, C, D, E, F
or G
3 Check the supply voltage 3.7
DIN-rail mounted IP20-unit (unsealed)
Nominal 24 V DC, Working range 18 - 36 V DC, X1:1-2
Wall mounted IP65-unit (NEMA 4)
85 - 264 V AC (100 V - 15% to 240 V + 10%), 45-65 Hz, X9:1-2
Nominal 24 V DC, Working range 18 - 36 V DC, X1:1-2
4 Perform basic settings (if necessary) 3.7
5 Perform setup:
Fast setup 3.8
Complete setup 3.11
6 Check load cell signal polarity 3.9
7 Check load cell function 3.10