1. Apply a known weight on the roll (see Figure 3-1).
2. Enter the value of the known weight. Confirm with .
10
Select Yes and press to set up the voltage output.
11 Enter the tension value corresponding to 10 V.
Confirm with .
12 Select filter settings (15, 30, 75, 250, 750 or 1500 ms) from
the list with or . Confirm with .
13 Select Yes and press to set up the current output.
Confirm with .
14 Enter the tension value corresponding to 20 mA.
Confirm with .
15 Select filter settings (15, 30, 75, 250, 750 or 1500 ms) from
the list with or . Confirm with .
16 Press to finish the fast setup and go to the operator
menu.
Table 3-1. Units used in the Hang Weight menu.
Selected unit in the
presentation menu
Shown and entered unit
in the Hang Weight menu
N/m N
kN/m kN
kg/m kg
pli lbs

Performing Fast Setup using Wrap Gain
1 Press for 5 seconds to go to the fast setup menu.
2 Press to start the fast setup sequence.
3 The menu SetWebWidth will only be available when the
selected unit is N/m, kN/m, kg/m or pli.
Default Web Width is 2m (78,740 inch).
4 Select WrapGain from the list with or .
Confirm with .
5 Select the number of load cells that support the roll (2 or
Single Side A or Single Side B) from the list with or .
Confirm with .
6 Check the nominal load on the load cell name plate.
Select nominal load from the list with or .
Confirm with .
7 Zero set is used to compensate for load cell zero signal and
tare weight.
Zero set must be done with no tension applied to the roll.
8 1. Check that no load is applied on the roll.
2. Press to zero set. “ActionDone” is shown on the
display for one second to confirm the zero setting action.
9 Enter the calculated wrap gain. For calculating wrap gain,
see Appendix (B, C, D, E, F or G) for installed load cell type.
Confirm with .
10 Select Yes and press to set up the voltage output.
11 Enter the tension value corresponding to 10 V.
Confirm with .
12 Select filter settings (15, 30, 75, 250, 750 or 1500 ms) from
the list with or . Confirm with .
13 Select Yes and press to set up the current output.
14 Enter the tension value corresponding to 20 mA.
Confirm with