+086-15305925923

K-WANG

Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

EATON Ambassador series (models 5760X-405, etc.) counting controller

From: | Author:Wang | Time :2026-03-11 | 18 visit: | Share:


EATON Ambassador series (models 5760X-405, etc.) counting controller

Product Basic Core Information

Core positioning and model differences

Equipment type: Industrial grade programmable counting/batch/rate controller, supporting length measurement (exclusive to foot/inch models), can be programmed to adapt to various industrial needs such as counting, timing, trigger control, etc;

Model differentiation:

Model suffix, power supply type, display color, core function

405 DC/115VAC/230VAC green ordinary counter+rate meter

415 DC/115VAC/230VAC green foot/inch length control (without speedometer)

455 DC/115VAC/230VAC red ordinary counter+rate meter

465 DC/115VAC/230VAC red foot/inch length control (without speedometer)

Core advantages: Multi functional integration (counting, batch, rate), high flexibility (8 counting modes, 14 input functions), strong environmental adaptability (NEMA 4 protection).

Key technical parameters

Power supply and auxiliary output:

Power supply type, specification parameters, fuse requirements

DC 10-15VDC, Maximum 300mA 1/2A slow melting

115VAC ± 15% fluctuation, 50-60Hz, 7W 1/8A slow melting (US standard), 60mA slow melting (European standard)

230VAC ± 15% fluctuation, 50-60Hz, 7W 1/16A slow melting (US standard), 125mA slow melting (European standard)

Auxiliary output 12VDC ± 25%, maximum 100mA-

Counting and speed performance:

Functional specifications

Main counter with 6 bidirectional digits, preset with 4 digits (P1-P4), scale range 0.00001-9.99999

Accumulator 8-bit bidirectional, synchronized with the main counter for counting

Batch counter 6-digit unidirectional, 1 preset, main counter increments when cycling

Rate meter 1/Tau algorithm, accuracy ± 0.015%, 2 alarm setpoints

Counting frequency up to 16000Hz (orthogonal X4 mode), minimum 40Hz (contact input)

Input and output parameters:

Type and specification

Control 4 inputs, current mode, impedance 4.7k Ω, high level 3.7-24VDC, low level 0-0.9VDC

Count input 2 (A/B), support current injection/extraction, DC voltage 0.6-17VDC, maximum AC voltage 17VAC

Relay output 2 SPDT, 250VAC/360VA, 150VDC

Solid state output with 2 NPN open collectors, 30VDC maximum, 200mA maximum current

Communication parameters: RS-485 interface, baud rate 300-19200, data format 1 start bit+7 data bits+1 check bit+1 stop bit, supports host mode (response command) and printer mode (active output).


Safety regulations and installation process

Core security requirements

Operation taboos: All power sources must be disconnected before wiring and disassembly, and live working is prohibited; Separate the laying of signal cables and power cables to avoid electromagnetic interference;

Cable requirements: Shielded cables are required for counting, control, and communication signals, with the shielding layer connected to the equipment common end (terminals 2/3/4);

Power protection: The AC power input must be connected in series with a slow melting fuse to avoid overloading and damaging the equipment; Attention should be paid to the positive and negative polarity wiring of DC power supply models to prevent reverse connection.

Installation and wiring specifications

Mechanical installation:

Panel opening size: 68 × 68mm (± 0.7mm), equipment panel size 75 × 75mm, maximum panel thickness 12.7mm;

Installation accessories: including sealing gasket, 2 installation clips, 4 screws. During installation, ensure that the gasket is tightly attached to the panel and the screws are not too tight (to avoid gasket deformation);

Physical dimensions: The device body measures 67 × 67 × 142mm and weighs 0.54kg.

Wiring details:

Terminal specifications: 22 pluggable screw terminals, supporting 14-22AWG solid/multi strand wires;

Power wiring: AC model terminal 11 (live wire), 12 (neutral wire), DC model terminal 1 (positive electrode), common terminal (terminals 2/3/4);

DIP switch configuration: 4 switches are located at the bottom of the device, with the following functions:

Switch 1, Switch 2, Switch 3, Switch 4, Function

OFF OFF OFF OFF Input A/B are both current filled, high threshold

ON - Input A is the pulling current

-ON - Input B is the pulling current

-- ON - Input A is low threshold (compatible with magnetic sensor)

--- ON input B is a low threshold (compatible with magnetic sensors)

Wiring principle: All signal cables should be as short as possible to avoid being laid in close proximity and parallel with strong interfering equipment such as frequency converters and motors.

Programming configuration core process

The device programming is completed through 8 buttons on the panel, and the core menu is divided into 9 modules. The key programming process is as follows:

Basic Configuration (Phase I)

Program Count In: 8 counting modes (such as A-B addition and subtraction, orthogonal X4, etc.) that need to be matched with sensor types (encoder/proximity switch, etc.);

Program Scalers:

C Scaler: Formula CS=DPF/PPI (DPF is the decimal factor, PPI is the number of pulses per unit);

R Scaler: Formula RS=(SEC x DPF)/PPI (SEC is the unit of time in seconds);

Preset and reset settings: preset number of main counters (1-4), reset mode (reset to zero/final preset), automatic loop function (whether to automatically reset at the preset position).

Input/output configuration (Phase II)

Program Input Allocation: Four inputs can be configured for 14 functions including reset, output control, pause counting, print trigger, etc;

Program Out Mode Configuration:

Trigger type: Count trigger (preset/reset event) or rate trigger (above/below set point);

Output logic: Normal/reverse mode, latch/pulse output (pulse time 0.01-99.9s), supports delayed start (0-99.99s);

Program Display: 15 types of operation screens (such as main count+preset, rate+alarm point, etc.) can be set to display/hide, and support editing 8-character unit text (such as "COUNT", "FEET").

Serial communication configuration (Program Ser Port/Ser Out)

Port settings: Device ID (00-99, unique identifier), baud rate (default 19200), parity (none/odd/even), transmission delay (2ms/100ms);

Transmission mode: Host mode (responds to external commands) or printer mode (triggers transmission by pressing the print button/input);

Transmission List: 13 data items (SEND/SKIP) including main count, batch, accumulator, preset, etc. can be selected for transmission.

Exclusive configuration for foot/inch models

Counting display: The main counter is divided into 4 feet and 2 inches (separated by a fixed decimal point), with internal counting in inches, ranging from 0000.00 to 9999.11;

Pre alarm function: The pre alarm value (Pw) automatically tracks the final preset value (Pf), with a fixed interval (such as Pw=240.00 when Pf=250.00);

Restricted function: No speed meter, no speed alarm output, some display screens are unavailable.


Operation and maintenance

Running operation process

Power on self-test: automatically performs 6 internal tests (ROM/RAM/NOVRAM, etc.) after power on, and displays "ERROR X" (X is the test number) when a fault occurs;

Panel operation:

Screen switching: Use the up and down keys to switch between 15 running screens and view data such as main counter, accumulator, batch, rate, etc;

Preset editing: After selecting the preset screen, press the SEL key, flash the digit to adjust with the plus or minus keys, and confirm with the ENT key;

Reset operation: Press the RST/CLR key (the function of this key needs to be programmed first) to reset the main counter/accumulator/batch counter;

Data transmission: In printer mode, pressing the PRNT key or triggering the corresponding control input can output the preset transmission list data.

Troubleshooting and Maintenance

Common faults and solutions:

Possible causes and solutions for the fault phenomenon

Display blank power supply wiring error/abnormal voltage. Check the power terminal voltage and confirm that the fuse is intact

Do not count scale setting error/DIP switch configuration incorrect/sensor fault scale set to 1.00000 for testing, check DIP switch, use jumper to test terminals 4 and 20 (count+)

Error "ERROR 3" running data storage failure Press RST key to reset all counts/preset to zero

Error "ERROR 4" program configuration storage failure. Press RST key to restore factory default settings

Daily maintenance: Regularly check the tightness of wiring, clean the panel, and avoid corrosive cleaning agents from contacting the equipment;

Accessory selection: Optional accessories include RS-485 to RS-232 converter, signal conditioner, RC surge suppressor, encoder, etc.

  • MOOG 76-264 - Servo Valve
  • MOOG 72-101 SER.1907R - Servo Valve
  • MOOG B52576-1 - Controls Valve Part
  • MOOG CN1000 - Servo Controller
  • MOOG CM-65-105-G-A04 - Servo Controller Evaluation
  • MOOG WSH53P32C108CS - Clamp Proportional Valve
  • MOOG ZFDRP06A4K0ASA - Check Valve
  • MOOG CCE40B64WX06A2 - Check Valve
  • MOOG CCE32B61WX06C3 - Check Valve
  • MOOG CCE25B62DAX - Check Valve
  • MOOG CCE25B61DX - Check Valve
  • MOOG CCE50C11WX06 - Hydraulic Proportional Cartridge Solenoid Valve
  • MOOG CCE50A6RH1X10 - Hydraulic Cartridge Valve HPN703404
  • MOOG CCE25B62DRX - Cartridge Valve XGB10016-000-01
  • MOOG Cce16 B6rma0v06/A12 - Throttle Valve Xeb15892-001-01
  • MOOG CB64541-001 - Crimp Connector 11+PE 24V
  • MOOG CB64539-001 - Crimp Connector 11+PE
  • MOOG RSE25BU6T2WX - Cartridge Valve HPN2946887
  • MOOG XPB10004-000-01 - Cartridge Proportional Valve
  • MOOG XEB11483-000-01 - Cartridge Proportional Valve
  • MOOG XCB10235-000-00 - Cartridge Valve
  • MOOG C43285-203 Rev. D - Control Board and Coil
  • MOOG BS23-28FC-04CHP - Servo Motor
  • MOOG G631-3005A - Servo Valve
  • MOOG BN34-35CD-04CHEP - Servo Motor
  • MOOG BN34-25CD-01LH - Servo Motor
  • MOOG BN23-28EF-01CHG - Servo Motor
  • MOOG BI160D - Servo Drive Evaluation
  • MOOG B97012-024 - Hydraulic Servo Valve D-71034
  • MOOG B80HXAGGNSF2 - Servo Valve Component
  • MOOG B64569-2V - 10 Micron Hydraulic Filter Element
  • MOOG B48333-801 - Hydraulic Component
  • MOOG B35829-008A - Linear Actuator
  • MOOG API090E - Servo Evaluation Component
  • MOOG SM23205D-DN-F1 - Animatics Smart Motor Servo
  • MOOG AC6023-24C - Servo Valve Component
  • MOOG AC4598-6 - Servo Valve Component
  • MOOG A72068-1 - Hydraulic Component
  • MOOG A32179-1 - Hydraulic Servo Valve
  • MOOG A11592 - Hydraulic Servo Valve D635-606C
  • MOOG A076-795 - ServoCon Valve A076795
  • MOOG A076-506 - Servo Valve A076506
  • MOOG A076-401R - Hydraulic Servo Valve
  • MOOG A076-103HRI-10 539 - Servo Valve
  • MOOG A076-102 - Servo Valve
  • MOOG A076-101A - Hydraulic Servo Valve
  • MOOG A05891-1 - Hydraulic Component
  • MOOG 963.364.8011A - Hydraulic Servo Valve
  • MOOG 963.364.8011 - Hydraulic Servo Valve
  • MOOG 897012-024 - Hydraulic Servo Valve
  • MOOG 7WEFS42P06C88B - Hydraulic Proportional Servo Valve
  • MOOG 79.212 - Servo Valve
  • MOOG 79.211 - Servo Valve
  • MOOG 78.5113 - Servo Valve
  • MOOG 78 Series - Servo Valve Series
  • MOOG 771F232 - Hydraulic Servo Valve
  • MOOG 771-117 - Hydraulic Servo Valve
  • MOOG 770-147E - Valve Assembly G2761AM002
  • MOOG 77-703 - Servo Valve
  • MOOG 77-553 - Servo Valve
  • MOOG 77-159 - Servo Valve
  • MOOG 77-123 - Servo Valve
  • MOOG 761-5077B - Electro-Hydraulic Servo Valve
  • MOOG 761-4088B5 - Hydraulic Servo Valve
  • MOOG 760N1181B - Electro-Hydraulic Servo Valve 3000psi
  • MOOG 760N1087A - Servo Valve
  • MOOG 760N1085A - Servo Valve
  • MOOG 760K645B - Electro Hydraulic Servo Valve
  • MOOG 760C461A - Servo Valve
  • MOOG 760C262A - Servo Valve MOD 252.23C-01
  • MOOG 760A509A - Servo Valve
  • MOOG 760A508A - Servo Valve
  • MOOG 760A191A M3741851 - Flow Control Hydraulic Servo Valve
  • MOOG 760-851A - Servo Hydraulic Valve
  • MOOG 760-795A - Attica Servo Valve
  • MOOG 760-748A - Directional Control Valve
  • MOOG 760-508A - Servo Valve
  • MOOG 760-101 - Servo Valve
  • MOOG 76-263C - Hydraulic Valve
  • MOOG 76-185 M2021851 - Flow Control Hydraulic Servo Valve
  • MOOG 76-100 - Hydraulic Servo Valve
  • MOOG 74937-1 - Hydraulic Control Valve
  • MOOG 744F007 - Servo Valve 2019 Model
  • MOOG 744F006 - Servo Valve
  • MOOG 744 Series - Servo Valve Evaluation
  • MOOG 743-003D - Servo Valve
  • MOOG 743 Series - Servo Valve Evaluation
  • MOOG 730Y218-H P5 - Servo Valve
  • MOOG 73-797 - Hydraulic Servo Valve
  • MOOG 73-744 - Hydraulic Servo Valve
  • MOOG 73-233 - Hydraulic Servo Valve
  • MOOG 73-104 - Hydraulic Servo Valve
  • MOOG 73-103 - Hydraulic Servo Valve
  • MOOG 73-101 - 2 Stage Flow Control Servo Valve
  • MOOG 720B210062554 - Electronic Control Unit
  • MOOG 72-516 - 72 Series Servo Valve
  • MOOG 72-101 - Servo Valve 1906R
  • MOOG 642-515A - Proportional Valve T654R
  • MOOG 641-229B - Proportional Directional Control Valve
  • MOOG 631F172F5 - Hydraulic Servo Valve
  • MOOG 631-3015B - Hydraulic Servo Valve
  • MOOG 631 SERIES - Hydraulic Servo Valve
  • MOOG 630-1283D - Servo Valve S30HOGB4NNL
  • MOOG 62F120 - Hydraulic Servo Valve
  • MOOG 62-321 - Electro-Hydraulic Servo Valve
  • MOOG 62-314A - Hydraulic Servo Valve
  • MOOG 62-134 - Hydraulic Control Valve
  • MOOG 60B401H - Hydraulic Servo Valve
  • MOOG 60B023H - Hydraulic Servo Valve
  • MOOG 60-B021H - Hydraulic Control Valve
  • MOOG 60-297 - Hydraulic Control Valve
  • MOOG 505-50 - Hydraulic Servo Valve 5GPM
  • MOOG Jul-63 - Torque Motor Servo Component
  • MOOG 306A-133B - Power Supply Module
  • MOOG 306-235 - Power Supply Module
  • MOOG 305A-141C - Valve Driver Card
  • MOOG 304-131A - Signal Conditioning Module
  • MOOG 304-121A - Signal Conditioning Module
  • MOOG 218-121 - Hydraulic Servo Valve 15GPM
  • MOOG 211A-630 - Hydraulic Servo Valve 3000PSI
  • MOOG 211A-153 - Hydraulic Servo Valve
  • MOOG XCB 10826-000-00 - 2-Way Active Cartridge Valve
  • MOOG M-CEE25B6RS - 2 Way Cartridge Check Valve
  • MOOG G761-3004B - Servo Valve H38JOGM4VPL
  • MOOG 192R S20F0FM4VBR - Electro-Hydraulic Servo Valve
  • MOOG 164003B00A72 - Servo Controller Module
  • MOOG 164-009E-10-B2-2 - Servo Controller Module
  • MOOG 164-009D-10-B1-2 - Servo Controller Module