Eaton XV-102-L Series Touch Screen Display

From: | Author:Wang | Time :2026-04-20 | 142 visit: | 🔊 Click to read aloud ❚❚ | Share:


Eaton XV-102-L Series Touch Screen Display

Product Overview

Product Series

Model: XV-102-L-35/57/70

Screen specifications:

3.5":QVGA(320×240)

5.7":VGA(640×480)

7.0":WVGA(800×480)

Touch type: 4-wire resistive touch

Core hardware:

CPU:800 MHz 32‑bit RISC

Memory: 512 MB DRAM+4 GB Flash

RTC battery: lithium battery, with a range of 10 years (25 ℃)

functional positioning

Standard: HMI operation display

Optional: HMI+PLC integration (CODESYS authorized version)


Interface configuration (standard/optional)

form

Type interface specification

Standard Ethernet 10/100 Mbps, RJ45

USB Host USB 2.0,500 mA

SD card supports SD/SDHC

Optional RS-232 (COM1) 9-pin D-Sub

RS-485 (COM2) 9-pin D-Sub

CAN CANopen / J1939


Safety regulations (mandatory requirement)

personnel qualification

Only certified electricians who comply with EN 50110-1 are allowed to install, wire, and maintain.

Electrical safety

The power supply must be a 24 VDC SELV/PELV safety isolated power supply

Operating voltage range: 19.2~30.0 VDC

Before wiring, it is necessary to: power off → prevent accidental closing → check the electricity → ground

Prohibition of use

Strictly prohibited for use in safety related functions (emergency stop, safety door, protection, etc.)

Only allowed for use in ATEX Zone 22 dusty environment

Prohibited for use in gas explosion-proof zone 0/1/2 environment

Protection level

Front panel: IP65, NEMA 4X/12

Rear: IP20

Installation environment and mechanical requirements

environmental parameters

form

Project values

Working temperature: 0~50 ℃

Storage/transportation temperature -20~+60 ℃

Humidity 10~95% RH (no condensation)

Altitude ≤ 2000 meters

Installation requirements

Installation method: Front embedded installation, can be installed horizontally/vertically

Panel thickness: 2~5 mm

Installation flatness: ≤ 0.5 mm

Heat dissipation gap: ≥ 30mm around the device**

Number of fixed brackets:

3.5 ": 4 pieces

5.7 ": 6 pieces

7.0 ": 8 pieces


Electrical connection

Power wiring

Connector: MSTB 2.5-3-ST-5.08 3-core terminal

Pin definition:+24V/0V/FE functional ground

Cable cross-section: 0.75~2.5 mm ²

Tightening torque: 0.6~0.8 Nm

power waste:

3.5":≤ 5 W

5.7"/7.0":≤ 7 W

Communication wiring rules

All use shielded cables

Single end reliable grounding of shielding layer

Laying of communication and power lines in separate slots

Serial port distance and baud rate

form

Maximum length and highest baud rate of the interface

RS‑232 30 m 115200 bps

RS‑485 1200 m 115200 bps

CAN 5000 m 10 k ~ 1 M bps

Debugging and Running

Power on start

The device has no power switch, immediately start when connected to 24V

There is no pre installed engineering at the factory, and it needs to be downloaded through CODESYS/GALILEO

Operation taboos

It is strictly prohibited to turn on the power when there is condensation

Reducing backlight brightness can extend lifespan

USB usage restrictions

Only allowed for maintenance purposes

Industrial sites prohibit long-term connection of ordinary USB devices (EMC interference risk)


Fault handling

form

Common causes and solutions for fault phenomena

Unable to power on, no 24V/reversed polarity/damaged fuse. Check power supply, wiring, and voltage

Touch unresponsive, uncalibrated/touch off, execute touch calibration

Communication abnormalities, wiring errors/poor shielding/baud rate mismatch. Check wiring, grounding, and parameters

Frequent crashes, voltage fluctuations/EMC interference, installation of power filter, optimization of grounding


Maintenance and Disposal

routine maintenance

Touch screen: wipe with a soft cloth, prohibit solvents and sharp objects

Touch offset: Perform recalibration

The equipment is maintenance free as a whole and disassembly is strictly prohibited

Storage and transportation

Original packaging must be used

Moisture proof, vibration resistant, and UV resistant

Disposal

Built in lithium batteries must be professionally recycled and incineration is prohibited

Classify and dispose of environmental protection according to local regulations


Certification and Standards

UL508、CE

DNV-GL classification certification

ATEX Zone 22 Dust Explosion proof

Compliant with EN 61131-2 and EN 61000 industrial EMC standards


Key issues (3, with different focuses)

Question 1 (Safety Focus)

What are the mandatory safety red lines for power supply and use of the XV-102-L series? answer:

24 VDC SELV/PELV safety isolated power supply must be used, with a voltage of 19.2-30V. Non isolated power supply is prohibited.

It is strictly prohibited to use it for any safety related functions (such as emergency stop, safety door, safety circuit).

Only allowed for use in ATEX Zone 22, prohibited for use in gas explosion-proof Zone 0/1/2 environments.

Only certified electricians are allowed to install, wire, and maintain.

Question 2 (Installation Focus)

What mechanical and heat dissipation conditions must be met during the installation of XV-102-L to ensure protection and longevity? answer:

The panel thickness must be 2-5 mm, and the flatness of the installation surface should be ≤ 0.5 mm.

A ventilation gap of ≥ 30mm must be reserved around the equipment for natural convection and heat dissipation.

All fixed brackets must be installed in quantity (3.5 "4, 5.7" 6, 7 "8) to ensure IP65.

Stay away from heat sources by ≥ 15 cm, avoid direct sunlight and UV aging.

Question 3 (Electrical Focus)

What are the key limitations when wiring the serial port and communication interface of XV-102-L? Why is USB only for maintenance use? answer:

The maximum length of RS-232 is 30 meters, and the maximum length of RS-485 is 1200 meters, and both ends must be connected to a 120 Ω terminal resistor.

All communication lines must be shielded, with the shielding layer grounded at one end and routed separately from the power line.

USB is limited to maintenance because ordinary USB devices have poor industrial EMC performance, which can easily introduce interference and cause crashes and communication failures.

  • Beckhoff KL3162 - PLC Module KL 3162
  • Beckhoff EL3255 - PLC module
  • Beckhoff AX5201-0000 - servo driver
  • Beckhoff CX5130-0125 - Embedded PC Intel Atom 1.75GHz processor, 4GB DDR3 RAM
  • Beckhoff CU1521 - industrial switch
  • Beckhoff C6920-1057-0030 - #NAME?
  • B&R 7CP476.60-1 - 1 module 1
  • Beckhoff KL2552 - PLC module
  • Beckhoff CP6223-0002-0060 - #NAME?
  • Unknown BK7350-1060 - EtherCAT bus coupler
  • Beckhoff CX2040-0155 - Automation Basic CPU module, Windows 10 IoT Enterprise
  • Beckhoff CX5230-0175 - 000029724 Embedded PC Industrial PC On Rail
  • Beckhoff EL4134 - PLC Modules
  • Beckhoff EK1100 - automation coupling module EtherCat coupler coupling modules
  • Beckhoff EL6201 - Programmable Controller Module
  • Beckhoff CX2033-0175 - 000107116 embedded PC
  • Beckhoff AM3021-0C40-0000 - #NAME?
  • Beckhoff CX1020-0021 - CPU Module
  • Beckhoff CX2030 - PLC CPU Module
  • Beckhoff CX5130-0120 - PLC Modules
  • Beckhoff CX5230-0175 - 000029724 Embedded Controller Auf Schiene Industrial Pc
  • Beckhoff CX5130-0175 - PC CPU Module HW 4.4 Intel Atom Industrial CX2900 0038 40GB
  • Beckhoff AX5125-0000-0200 - #NAME?
  • Beckhoff KL3011 - One PLC Module
  • Beckhoff CX2020-0120 - 4 GB Basic CPU Module
  • Beckhoff CX1100-0920 - PLC CPU Module Module
  • AB 20F11NC3P5JA0NNNNN - Industrial Automation Part
  • Beckhoff AX5206-0000-0200 - #NAME?
  • Beckhoff CP6700-0001-0050 - , -
  • Beckhoff BECKHOFF-FOR-CX2000-4GB-CFAST-CARD-SLC-FLASH - - - -
  • B&R X67BC6321.L12 - X67 SYSTEM
  • Beckhoff CX9000-0001 - Controller module
  • Beckhoff AX5206-0000-0200 - #NAME?
  • Beckhoff CP2919-0000 - Multitouch Built In Control Panel 24VDC 19"
  • Beckhoff CP6032-0000-0010 - - 15" OPERATOR CONTROL PANEL
  • Beckhoff KL2791 - PLC module
  • Beckhoff CP7902-0001-0000 - - Touch Panel Power Supply 24VDC
  • Beckhoff CP6702-0001 - Open Interface Panels
  • Beckhoff CU8800-0010 - Communication / Interface Module Module
  • Beckhoff C6920-0010 - Driver
  • Beckhoff EL6614 - EtherCAT / Bus Terminal
  • Beckhoff AX5203-0000-0200 - #NAME?
  • Beckhoff EK1322 - 2 port EtherCATP junction Rev 0017
  • Beckhoff EP2349-0021-16 - EtherCAT Box - 16 Channel Module
  • Beckhoff CP6801-0021-0010 - Touch Panel - 12" 14 1 1020
  • Beckhoff CX1020-0112 - - N00 N010 CX1100 0004 PLC CONTROLLER R1S13.7
  • Beckhoff EL2784 - EtherCAT / Bus Terminal Module
  • Beckhoff CX2020-0155 - PLC CPU Module Module
  • Beckhoff EK1914 - PLC EK 1914 Module
  • Beckhoff Cx5130-0122 - PLC CPU Module
  • Beckhoff CX5010-0112 - CPU module
  • Beckhoff CP7811-0001 - - 0 0
  • Beckhoff EL3162 - controller module
  • Beckhoff CU2508-0000 - 8 Port Port Multiplier PLC Processor
  • Beckhoff CX5010-1112 - Mod CPU Module K Bus Windows Runtime TwinCAT 2 NC
  • Beckhoff BECKHOFF-CX2100-0914-CX21000914 - Industrial Automation Part
  • Beckhoff CX1500-M310 - PLC Module
  • B&R 7CP476.60-1 - 1 module 1
  • Beckhoff EL5042 - EtherCAT / Bus Terminal
  • B&R AT6402 - X20 PLC MODULE X20 ORIGINAL
  • Beckhoff CP7802-1327-0010 - #NAME?
  • Beckhoff CX1100-0002 - Power Module
  • Beckhoff CX2040-0155 - PLC CPU Module
  • Beckhoff EP1809-0021 - PLC Modules
  • Beckhoff CX2040 - 0142 Communication Module
  • Beckhoff CX2900-0033 - PLC CPU Module
  • Beckhoff CX2500-0030 - Interface Module
  • Beckhoff EK1100 - Module Ethernet Kommunikaton Modul
  • Beckhoff KL4428 - Bus Terminal 8 Channel Analog Output
  • Beckhoff CX5130-0122 - embedded PC CPU module 4 GB industrial PC CPU module HW 3.5
  • Beckhoff CX9020-0111-1002 - PLC CPU Module
  • Beckhoff CP6929-0001-0000 - Touchscreen Panel 6.5" ELO Model -
  • Beckhoff EP4174-0002 - Module HTP0
  • Beckhoff CP6092-0011-0000 - - Touch Screen 15" Panel
  • B&R 5WCC00000440K0-001 - PANEL PC 2100 SYSTEM UNIT AUTOMATION PANEL
  • Beckhoff CX2100-0014 - Original
  • Beckhoff CX5120-0115 - 3243
  • Beckhoff CP3919-1039-0011 - Multi Touch Control Panel - 19" G190ETN01.2
  • Beckhoff CX9001-0101 - PLC Module QW
  • Beckhoff BECKHOFF-CX5120-121 - Industrial Automation Part
  • Beckhoff BECKHOFF-BX8000-0000 - Industrial Automation Part
  • Beckhoff AX511200000200 - AX5112 0000 0200 Servo Driver
  • Beckhoff EL2564 - EtherCAT Terminal, 4 channel LED output, 5 8VDC, 4A, RGBW
  • Beckhoff KL4494 - EtherCAT / Bus Terminal
  • B&R 5e9000.17 - Control Panel
  • Beckhoff BX8000 - PLC Module
  • Beckhoff AS1060-0110 - , Stepper Motor Precision .........
  • B&R 0702-10B - 6PPT50. Touch Panel
  • Beckhoff C6930-0050 - Schaltschrank Industrie Pc Core i7 4700 CPU+FC9062 Module
  • Beckhoff KL2702 - PLC Controller Module
  • Beckhoff EL4038 - Communication Module
  • Beckhoff EK1110-0008 - EtherCAT / Bus Terminal Module
  • Beckhoff CX5020-0111 - PLC CPU Module
  • Beckhoff CP7232-0001-0050 - #NAME?
  • Beckhoff FC3101-0000 - communication module
  • Beckhoff EL6930 - EtherCAT Klemme
  • Beckhoff EL6631 - EtherCAT / Bus Terminal
  • Beckhoff EK1100 - ,EL2202,EL1904,EL1809,EL9189,EL9188,EL2809,EL3122,EL3102,EL4102
  • Beckhoff EL6695 - EtherCAT / Bus Terminal
  • Beckhoff CX1500-M510 - CX1020 N000 CX1020 0011 CX1100 0002 Controller Set
  • Beckhoff AM8052-1F20-0000 - - motor -
  • Beckhoff C6925-1004 - Industrial PC
  • Beckhoff 7132-0001 - CPPC
  • Beckhoff CP6001-0011-0010 - - Control Panel 12 inch TFT Display, 001...
  • Beckhoff CX2020-0120 - 4GB CPU ,CX2100 0904 3x EL6900, EL1904 16 GB Memory
  • Beckhoff C6920-0030 - Controller
  • B&R 3DM486.6 - DIGITAL MIXED MODULE DM486
  • Beckhoff KL3361 - PLC Module KL 3361
  • Beckhoff C9900-H391 - operating system
  • Unknown CKS-10T - Industrial Automation Part
  • Beckhoff CX1100-0910 - Power Supply Module
  • Beckhoff C5210-0010 - Communication Module C5210
  • BECKHOFF KL1352 - Bus Terminal SET OF 2 FREE FAST SHIP
  • Beckhoff EL3058 - 8 x analog input single ended 4...20mA 85惟 shunt 12bit
  • Beckoff CX1100-0920 - UPS Module 24VDC (US SELLER) * *
  • BECKHOFF C6920-0000 - C69200000 PLC Moudule
  • Beckhoff CX5120-0115 - CPU controller module CX5120-0115
  • Unknown 15F5C1E-Y50A - Of Frequency Converters
  • Beckhoff AX5118-0000-0200 - Servo Drive HTP0
  • BECKHOFF AX5106-0000-0200 - Servo Drive
  • Beckhoff CX5240-0175 - Module (free) #U2327D YG
  • Beckhoff CP6607-0001-0000 - Compact PC Panel Economy Installation Operator 5,7 "
  • Beckhoff EP3744-0041 - 2022 EP37440041 Module
  • Beckhoff CP6209-0001-0020 - 6.5" PC Touch Screen Control Panel 24VDC
  • Beckhoff CX9020-0111 - /U900 +8x+2xEL3121+1x EL9410+3xEL1008+1x EL2008 Set
  • Beckhoff C6525-1030-0050 - Industrial PC
  • Beckoff CX1100-0920 - UPS Module 24VDC (US SELLER)
  • Beckhoff CX5010-0120 - CX5010 Processor Intel Atom Z510 B24