Eaton XV-102-L Series Touch Screen Display

From: | Author:Wang | Time :2026-04-20 | 112 visit: | 🔊 Click to read aloud ❚❚ | Share:


Eaton XV-102-L Series Touch Screen Display

Product Overview

Product Series

Model: XV-102-L-35/57/70

Screen specifications:

3.5":QVGA(320×240)

5.7":VGA(640×480)

7.0":WVGA(800×480)

Touch type: 4-wire resistive touch

Core hardware:

CPU:800 MHz 32‑bit RISC

Memory: 512 MB DRAM+4 GB Flash

RTC battery: lithium battery, with a range of 10 years (25 ℃)

functional positioning

Standard: HMI operation display

Optional: HMI+PLC integration (CODESYS authorized version)


Interface configuration (standard/optional)

form

Type interface specification

Standard Ethernet 10/100 Mbps, RJ45

USB Host USB 2.0,500 mA

SD card supports SD/SDHC

Optional RS-232 (COM1) 9-pin D-Sub

RS-485 (COM2) 9-pin D-Sub

CAN CANopen / J1939


Safety regulations (mandatory requirement)

personnel qualification

Only certified electricians who comply with EN 50110-1 are allowed to install, wire, and maintain.

Electrical safety

The power supply must be a 24 VDC SELV/PELV safety isolated power supply

Operating voltage range: 19.2~30.0 VDC

Before wiring, it is necessary to: power off → prevent accidental closing → check the electricity → ground

Prohibition of use

Strictly prohibited for use in safety related functions (emergency stop, safety door, protection, etc.)

Only allowed for use in ATEX Zone 22 dusty environment

Prohibited for use in gas explosion-proof zone 0/1/2 environment

Protection level

Front panel: IP65, NEMA 4X/12

Rear: IP20

Installation environment and mechanical requirements

environmental parameters

form

Project values

Working temperature: 0~50 ℃

Storage/transportation temperature -20~+60 ℃

Humidity 10~95% RH (no condensation)

Altitude ≤ 2000 meters

Installation requirements

Installation method: Front embedded installation, can be installed horizontally/vertically

Panel thickness: 2~5 mm

Installation flatness: ≤ 0.5 mm

Heat dissipation gap: ≥ 30mm around the device**

Number of fixed brackets:

3.5 ": 4 pieces

5.7 ": 6 pieces

7.0 ": 8 pieces


Electrical connection

Power wiring

Connector: MSTB 2.5-3-ST-5.08 3-core terminal

Pin definition:+24V/0V/FE functional ground

Cable cross-section: 0.75~2.5 mm ²

Tightening torque: 0.6~0.8 Nm

power waste:

3.5":≤ 5 W

5.7"/7.0":≤ 7 W

Communication wiring rules

All use shielded cables

Single end reliable grounding of shielding layer

Laying of communication and power lines in separate slots

Serial port distance and baud rate

form

Maximum length and highest baud rate of the interface

RS‑232 30 m 115200 bps

RS‑485 1200 m 115200 bps

CAN 5000 m 10 k ~ 1 M bps

Debugging and Running

Power on start

The device has no power switch, immediately start when connected to 24V

There is no pre installed engineering at the factory, and it needs to be downloaded through CODESYS/GALILEO

Operation taboos

It is strictly prohibited to turn on the power when there is condensation

Reducing backlight brightness can extend lifespan

USB usage restrictions

Only allowed for maintenance purposes

Industrial sites prohibit long-term connection of ordinary USB devices (EMC interference risk)


Fault handling

form

Common causes and solutions for fault phenomena

Unable to power on, no 24V/reversed polarity/damaged fuse. Check power supply, wiring, and voltage

Touch unresponsive, uncalibrated/touch off, execute touch calibration

Communication abnormalities, wiring errors/poor shielding/baud rate mismatch. Check wiring, grounding, and parameters

Frequent crashes, voltage fluctuations/EMC interference, installation of power filter, optimization of grounding


Maintenance and Disposal

routine maintenance

Touch screen: wipe with a soft cloth, prohibit solvents and sharp objects

Touch offset: Perform recalibration

The equipment is maintenance free as a whole and disassembly is strictly prohibited

Storage and transportation

Original packaging must be used

Moisture proof, vibration resistant, and UV resistant

Disposal

Built in lithium batteries must be professionally recycled and incineration is prohibited

Classify and dispose of environmental protection according to local regulations


Certification and Standards

UL508、CE

DNV-GL classification certification

ATEX Zone 22 Dust Explosion proof

Compliant with EN 61131-2 and EN 61000 industrial EMC standards


Key issues (3, with different focuses)

Question 1 (Safety Focus)

What are the mandatory safety red lines for power supply and use of the XV-102-L series? answer:

24 VDC SELV/PELV safety isolated power supply must be used, with a voltage of 19.2-30V. Non isolated power supply is prohibited.

It is strictly prohibited to use it for any safety related functions (such as emergency stop, safety door, safety circuit).

Only allowed for use in ATEX Zone 22, prohibited for use in gas explosion-proof Zone 0/1/2 environments.

Only certified electricians are allowed to install, wire, and maintain.

Question 2 (Installation Focus)

What mechanical and heat dissipation conditions must be met during the installation of XV-102-L to ensure protection and longevity? answer:

The panel thickness must be 2-5 mm, and the flatness of the installation surface should be ≤ 0.5 mm.

A ventilation gap of ≥ 30mm must be reserved around the equipment for natural convection and heat dissipation.

All fixed brackets must be installed in quantity (3.5 "4, 5.7" 6, 7 "8) to ensure IP65.

Stay away from heat sources by ≥ 15 cm, avoid direct sunlight and UV aging.

Question 3 (Electrical Focus)

What are the key limitations when wiring the serial port and communication interface of XV-102-L? Why is USB only for maintenance use? answer:

The maximum length of RS-232 is 30 meters, and the maximum length of RS-485 is 1200 meters, and both ends must be connected to a 120 Ω terminal resistor.

All communication lines must be shielded, with the shielding layer grounded at one end and routed separately from the power line.

USB is limited to maintenance because ordinary USB devices have poor industrial EMC performance, which can easily introduce interference and cause crashes and communication failures.

  • LTI Servo-One Junior SO22.006.0080.1000.0 - Servo Controller Servoregler
  • LUST CDA32.004, C1.4, H08, B0 - Servo Drive & LTI CM-CAN1 Module
  • LTI DRIVES LSP08-035-320-30-B0R1PY170 - Servo Motor
  • LUST LTI CDA32.004,C1.4.H08.B0 - SERVO CONTROLLER DRIVES
  • LUST LTi DRiVES CDS44.072LC1.2 - Servo Drive
  • Lti Servo-One Junior SO22.006.0082.1000.0 - Servo Controller Servoregler
  • LUST CDA32.008,C2.0,HF - Lti DRIVES Spindle Drive Inverter
  • LTI SO22.003.0082.0000.0 - Servo Drives One junior Servo Controller Servoregler
  • Lust Lti Drives CM-CAN1 - Communication Module
  • LUST Lti Drives Vf1202s, G8, I6 - Frequency Inverter Drive
  • LTI DRIVES BR-090.03.540.UR.H38 - Bremswiderstand Brake Resistor
  • LTi DRIVES PM-E40.2DRA054P - Wind Turbine Pitch Control Inverter
  • LTi Drives GmbH br-110.01.540-UR - Brake Resistor
  • LTI Drives LSN-097-0960-30-0560/T1,S4,B - Servo Motor
  • LUST CDA34.006.C2.0 - LTI Drives Servoregler
  • LUST LTI DRIVES SERVO ONE JUNIOR SO24.002.0020.0000.1 - Servo Drive Controller
  • LTI MOTION SO84.032.0003.0001.2 - Servo drives
  • LTI DDTD750V2-120 - IBOP ACTUATOR CYLINDER FOR TOP DRIVE
  • LTI CDE32.004, C2.4 - SERVO DRIVE
  • LUST LTI DRIVES CDD34.017 W3.4PC1 - Servo Drive Controller
  • LTI CDA3208,C3,0,HF - AC SERVO DRIVE
  • LUST LTI DRIVES LSH-074-3-30-560/T1,G6.1S - SERVO MOTOR
  • LUST Lti CDB32.004.C2.4.SH - AC Servo Drive
  • LTi CDA32.006, C3.0, H09 - Servo Drive
  • LTI SO22.003.0010.0000.0 - Servo Drive Servo one junior Servoregler Controller
  • LTi Drives DSM4-14.2-21R83-200 - Servo Motor
  • LUST Lti Drives Lsh-097-1-30-560/T1, 1R - Servomotor
  • LTI 1237 - 7 Piece 1/2" Drive Flip Socket Set
  • LTI Drives CDE34.008.W2.4 - Servo Drive
  • Lust LTi Drives SO84.008.1020.0070.1 - Servo One Drive
  • LTI DRiVES LSP06-015-320-30-00H1MY 170 - Servomotor
  • LUST LTi CDF30.008.C2.4 - Drives Inverter
  • Lust LTI Drives CDA34.017.C2.CP - Servo Controller
  • LUST CDA32.008,C1.4,HF - Lti DRIVES Spindle Drive Inverter
  • LTI Drives LSP08-028-320-55-B0H1MY17W - Sevomotor
  • LTI Motion SO84.032.0173.0100.1 - Servo Drive
  • LTi DRIVES LR32.8 0925.0018 - Einphasen-Netzdrossel Line Choke
  • LTI CDB34.006,W3.0,PC1,H39 - Servo Drive
  • LUST LTI Drives ALW80 BR-200.02,540,UR - R茅sistance Brake Resistor
  • LTi REENERGY Motion E230 G360 /1,2 BWrg-CFpu - Frequency Inverter Drive Controller
  • Lust CDB32.003,C2.4 - LTi Drives Servoregler Frequenzumrichter
  • LTi DRIVES BR-026.03.540-UR - Brake Resistance
  • Lust LTI DRIVES CDA32.006, C3.0, H09 - Frequency Inverter
  • LUST LTi Drives CM-CAN1 - Communication Module
  • LTI DRIVES lsn-127-2000-30-560/t1,s4x,b - Servomotor
  • LUST LTI Drives CDA34.017.C2.CP - Servoregler
  • LTi DRIVES SO84.016.1030.0000.0 - Servo one Drive
  • LTI Servo-One Junior SO22.006.0080.1000.0 - Servo Controller Servoregler
  • LUST Lti Drives Lsh-097-1-30-560/T1, 1R - Servomotor
  • LUST Lti Drives Vf1202s, G8, I6 - Frequency Inverter
  • LUST LTI Drives CDB32.003,C2.4 - Servo Drive
  • LTI MOTION SO24.004.0030.0001.1 - Servo drives
  • LUST CDA32.004,C1.4 - LTI Drives Servoregler
  • Lti Drives Lust CDA34.017.W3.0 - Control Unit
  • LUST CDA34.006, W3.0 - Controlador Servoregler LTI Drives
  • LTI Motion SO24-004-0030-1000-0 - Servo One Junior Drive Controller
  • Lust LTi Drives CDE34,010.D2.4 - Positioning Controller
  • Lust LTi Drives CDF30.002 C3.0 - Positioning Controller
  • LTI SO22.003.0080.0000.0 - Servo Controller Servo Regulator
  • LUST LTi CDB32.004,C2.4.SH - SERVO DRIVE
  • LTI DRiVES LSP06-015-320-60-B0H1MY170 - Servo Motor
  • LTI MOTION PM-D35.1WVA02 - Drive Module
  • LUST ANTRIESTECHNIK BC1300 - LTI DRIVES Brake Chopper
  • LTi DRIVES BR-090.03.540.UR.H38 - Bremswiderstand Brake Resistor
  • LUST LTi DRiVES CDE32.003,C2.3 - Servo Drive Controller
  • LUST LTI Drives CDA34.017.W2.0.H18 - Servo Drive
  • LTi DRIVES FGP 111/002-25 AA - Servomotor Servo Motor
  • Lti SO22.006.0080.1000.1 - Servo Controller Servoregler
  • LUST Lti Drives Vf1202s,G8,I6 - Frequency Inverter Drive
  • Lust CDA34.008,W1.4,BR - LTi Drives Servo Drive
  • LTi Drives Lust CDA34.017.W3.0 - Steuerungseinheit Control Unit
  • Keba/LTI Drives LSN-127-2400-15-560/T1.B.S4X - Servomotor
  • Drives by Lust LTI CDA34.006 W 1.5 - Frequenzumrichter Frequency Inverter
  • LTI DRIVES lsn-127-2000-30-560/t1,s4,b - Permanent Magnet Motor
  • LUST LTI Drives VF1204S, G10, FA - Frequency Inverter Drive
  • LTi DRiVES SO84.004.1030.0000.2 - Servo Drive
  • LUST CDA34.006, W3.0 - LTI Drives Servoregler Servo Controller
  • Lust CDE32.004,C2.4 - LTI Drives Controller
  • LTI MOTION CDE32.003,C2.4 - Servo Drive Controller
  • LTI CDE32.004, C3.0 - Servo Drive Controller
  • LUST CDA34.006.C2.0 - LTI Drives Servoregler Servo Controller
  • LUST LTI DRIVES LSH-097-2-30-560/T1,S4,G6.1S - Servo Motor
  • Lust Cdb32.003, C2.4 - Lti Drives Servo Controller
  • LTi DRiVES SO84.076.S030.0001.2-W - Servo One Drive
  • LUST LTI Drives CDA34.017.C2.CP - Regulador De Servomotor Servo Controller
  • LUST LTI Drives CDA34.008.C1.3 - Servoregler Servo Controller
  • LUST LTI Drives CDA34.017.C2.CP - Servoregler Servo Controller
  • Lust LTi Drives CDB32.003C2.3 - Servoregler Servo Controller with LTi UM-8I40 Module
  • LTI D-35633 - Servo Drive
  • LTi Drives Lust CDA34.017.W3.0 - Steuerungseinheit Control Unit
  • Lti SO22.003.0082.0000.0 - Servo Controller Servoregler
  • LTI Tools LT-1400Q - 1/2" Drive Wheel Torque Extension Tool
  • LTI CDE32.003-C3.0 - Servo Drive Controller
  • LTI CDA32.004 - Servo Drive
  • Lust Lti Drives CDB32.008, C2.3 - Servo Controller
  • LUST LTi Drives SO82.004.0030.0060.2 - Servo Drive
  • Lust LTI DRiVES CDA32.006,C3.0,H09 - Servo Drive
  • LUST LTI Drives CDA34.003. C3.0 - Servo Controller
  • LTI Motion CDE32.003.C2.4 - Servo Drive Positioning Controller
  • LTI CDB32.004.C3.7.SH - Servo Drive
  • LTI DRIVES VF1202S - Frequency Inverter Drive
  • LTI DRIVES GMBH LR34.44-UR - Line Choke Reactor
  • LUST LTi DRIVES LSH-097-1-30-560/T1,1R - Servo Motor
  • LTI DRIVES LSH-127-3-30-560 - Servomotor
  • LUST CDA32.008,C1,4,HF - LTi Spindle Drive Inverter
  • LUST LTI Drives CDA34.017.C2 - Servoregler Servo Controller with LUST LTI CM-DPV1,3.0 Modul
  • LTI DRIVES CM-DPV1,3.0 - Input Drive Communication Module
  • LTI CDE34.005,W2.4 - Servo Drive
  • Lust Lti Drives Cda32.008.C2.0,Hf - Servo Drive Spindle Inverter
  • LUST CDA34.006,W3.0 - LTI Drives Servoregler Servo Controller
  • LUST ANTRIESTECHNIK LR32.8 -- 0925.0018 - LTI DRIVES Choke Reactor
  • LUST LTI Drives CDA32.008,C3.0 - Servo Drive
  • LUST LTi DRIVES CM-DPV1 3.0 - Communication Module
  • LUST Lti Drives CDA34.008.C1.3 - Servoregulador Servo Controller
  • LTI DRIVES GMBH SO84.008.0020.0000.2 - Servo One Drive
  • LUST CDA34.006,W3.0 - LTI Drives Servoregler Servo Controller
  • LUST LTI DRIVES CDE32.003,C2.3 - Servo Drive Controller
  • LTI CD32.004 C3.0 AND CM-CAN1 - Servo Drive with Communication Module
  • LTI Motion CDE32.003.C3.0 - Servo Drive Positioning Controller
  • LUST SO84.012.0030.1700.2 - LTi Drives Servo Drive
  • LUST LTI Drives CCD34.024.W2.1.BR - Servo Drive with CM-CAN2 Communication Module
  • Lust CDA34.006.C2.0 - LTI Drives Servoregler Servo Controller
  • Lust Lti Drives VF1202S, G8, I6 - Frequency Inverter Drive
  • Lust LTi Drives CDE32.008,W2.2.BR - Positionierregler Position Controller
  • LTi DRiVES LSH-050-3-45-320/T1,S4,1R - Servomotor
  • LUST LTI Drives CDA34.006,W1.5,BR - Inverter with CM-RS485 Module
  • LUST ANTRIESTECHNIK VF1204S,G10,FA - LTI DRIVES VFD Variable Frequency Drive
  • Lust LTi Drives CDB32.008,C2.3 - Servoregler Servo Controller