The SINUS series is a high-frequency induction heating power supply launched by HIMMELWERK, designed specifically for industrial induction heating. It covers a power range of 5-25kW and a frequency range of 50kHz~2000kHz, with a total of 10 standard models that can meet different heating depths, speeds, and process requirements.
Core model and specification parameters
1) 5-12kW Small Series
Model HF Power Frequency Input Capacity Main Current Water Cooling Flow Host Size (mm) Weight (kg)
SINUS 51 5kW 500~1000kHz 5.5kVA 9A 4~5L/min 380×280×320 28
SINUS 52 5kW 1000~2000kHz 5.5kVA 9A 4~5L/min 380×280×320 28
SINUS 55 5kW 200~500kHz 5.5kVA 9A 4~5L/min 380×280×320 28
SINUS 62 6kW 50~200kHz 6.5kVA 10A 4~5L/min 380×280×320 28
SINUS 101 10kW 500~1000kHz 11kVA 16A 6~8L/min 400×280×420 33
SINUS 102 10kW 1000~2000kHz 11kVA 16A 6~8L/min 400×280×420 33
SINUS 105 10kW 200~500kHz 11kVA 16A 6~8L/min 400×280×420 33
SINUS 122 12kW 50~200kHz 13kVA 19A 7~9L/min 400×280×420 33
2) 25kW high-power series
Model HF Power Frequency Input Capacity Main Current Water Cooling Flow Host Size (mm) Weight (kg)
SINUS 251 25kW 500~1000kHz 28kVA 41A 10~12L/min 600×1100×600 110
SINUS 252 25kW 1000~2000kHz 28kVA 41A 10~12L/min 600×1100×600 110
Electrical and cooling specifications
standards of power supply
Input: 3 × 400V ± 10%/N/PE, 50/60Hz
Power factor: cos φ=0.95
Fuse: 16A~63A (matched by model)
Water cooling requirement (mandatory)
Flow rate: 4-12L/min
Inlet pressure:<6 bar
Pressure difference:>3.5 bar
Water temperature: 18-25 ℃
Advantage: No need for deionized water
Structure and physical parameters
Host: low-power model with a volume of 380 × 280 × 320mm, high-power model with a volume of 600 × 1100 × 600mm
External heating circuit: Compact design, size 120 × 140 × 240~250 × 300 × 170mm
Weight: Host 28~110kg, external circuit 7~28kg
Connection: Flexible cable connected to heating head

Product advantages
High efficiency, high reliability, highly reproducible parameters
Selective heating, precise temperature control
Support 100% duty cycle continuous operation
Ready to use, easy to integrate into production lines
High cost-effectiveness, easy maintenance
Can be connected to external dual heating heads (some models)
Support free programming and external control systems
Communication and Expansion
Standard: External Control Interface
Optional: Profibus, Profinet
Optional: Pyrometer interface
Other communication methods can be customized
Typical applications
Covering the vast majority of induction heating processes: brazing Soldering、 Quenching, hot assembly (shrinkage), preheating, annealing, melting, drying, tempering, forging, sintering, sealing.
Key issues
Question 1: What are the power and frequency coverage ranges of the SINUS series? What are the main impacts of different frequencies?
Answer: Power coverage ranges from 5kW to 25kW, and frequency coverage ranges from 50kHz to 2000kHz. Frequency determines heating depth: the higher the frequency, the stronger the skin effect, and the more concentrated the heating is on the surface; The lower the frequency, the deeper the heating depth.
Question 2: What are the mandatory requirements for cooling water in this series of equipment? Why not use deionized water?
Answer: The required flow rate is 4-12L/min, inlet pressure is * *<6bar * *, pressure difference is * *>3.5bar * *, and water temperature is 18-25 ℃. The product design allows the use of ordinary industrial cooling water without the need for deionized water, reducing on-site usage and maintenance costs.
Question 3: What are the core differences between SINUS 251 and 252, which are both 25kW models? What scenarios are suitable for each?
Answer: The difference lies in the working frequency:
SINUS 251:500~1000kHz, Suitable for medium depth and medium speed heating.
SINUS 252:1000~2000kHz, High frequency version, suitable for surface ultra high speed heating (such as fine brazing, surface quenching).