K-WANG



Product Overview
1. Product positioning
BRS BOBCAT's full range of fanless DIN rail industrial layer 2 network management switches are designed for harsh working conditions such as factory automation, rail transportation, ships, and substations; Supports 100/1000/2.5G power, multi specification SFP fiber, some models are equipped with IEEE802.3af/at PoE power supply, supports wire and ring network networking, built-in HiOS layer 2 firmware, compatible with industrial protocols such as RSTP, HIPER Ring, MACsec encryption, PROFINET, etc.
2. Division of complete machine series (ability to distinguish model prefixes)
BRS20: Pure 100M 10/100M electrical port model, without gigabit uplink
BRS22: 100Mbps+PoE power supply model
BRS30: Basic model with gigabit SFP expansion slot
BRS32: Gigabit Expansion+PoE Model
BRS40: Full Gigabit Electric (10/100/1000M) Basic Model
BRS42: Full Gigabit+PoE
BRS50: Supports 2.5G high-end electrical port models
BRS52: 2.5G+PoE model
3. Model coding rules (complete segmented definition)
BRS series identification; 2. Speed level (2=100Mbps/3=1G/5=2.5G); 3. Hardware type (standard/MACsec/PoE composite); Number of 4-7 100Mbps electrical ports; 8-9 Gigabit/2.5G port quantity; 10-13 uplink medium (RJ45/DSC fixed optical/SFP slot); 18 shell material C (plastic IP30)/D/E metal (IP40); 19-20 industry certifications (CE/UL/DNV/ATEX/Railway EN50121, etc.); 22 firmware versions (Entry/HIOS Standard/Advanced); 24 temperature width S (0-60 ℃)/T/E/G (-40~70 ℃).
4. Port media selection
Type of electrical port
10/100M RJ45: Automatic negotiation, automatic line sequence, automatic polarity, factory negotiation enabled;
10/100/1000M gigabit electricity;
100/1000/2.5G ultra gigabit power;
The PoE (af 15.4W)/PoE+(at 30W) models provide power to terminals through Ethernet cables, with two power supply specifications: U (up to 90W full machine PoE) and P (up to 240W high-power PoE).
fiber optic interface
Fixed DSC/DST multimode/single-mode 100Mbps optical port;
Pluggable SFP slot: Supports FastE/GE/2.5G, single-mode/multi-mode/long-distance LH, bidirectional BiDi optical modules, only original EEC wide temperature SFP can be used for -40~70 ℃ models, ordinary SFP will cause temperature derating.
5. Unified layout of body hardware
6-pin self-locking terminal: dual redundant power supply (P1/P2)+FAULT passive fault relay;
2-pin terminal: digital DI sensor input;
USB-C debugging port: paired with ACA22-USB-C adapter, for storage configuration, firmware upgrade, and local debugging;
V. 24 serial port cancellation, unified USB-C local management;
Whole machine status LED (P power supply, FAULT fault, PoE, ACA storage); Port LS link/DA data dual color indicator light;
MAC and IP handwritten identification area; Front grounding screw; DIN rail buckle on the back;
6. Management approach: Omnichannel
Local: USB-C ACA adapter; Remote: Web pages SSH、Telnet; Network management software: Industrial HiVision (batch configuration, topology, SNMP/OPC integration with SCADA); Protocol: DHCP/BOOTP/HiDiscovery automatically assigns IP addresses.
7. Core software functions
Dual redundant power monitoring, FAULT remote alarm relay, RSTP fast spanning tree, HIPER Ring self-healing loop, MAC/IP access control, port isolation, system time synchronization, hardware self-test, port standby/shutdown function, MACsec encryption, PROFINET industrial protocol, digital DI external signal acquisition.
Complete installation, wiring, and power on process
2.1 Preliminary Inspection
Unpacking and checking accessories: switch body, power terminal, DI terminal, magnetic ring (EMC optional), paper safety instructions; Check for transportation collision damage.
2.2 DIN rail installation and grounding
Compatible with 35mm standard DIN EN rail, with snap on upper and lower fastening fixation;
The grounding screw of the body is connected to the protective grounding wire, and the cable section is ≥ 1mm ²;
EMC magnetic ring optional model: The power cord passes through the magnetic ring twice and is installed within 5cm of the terminal to suppress conducted interference.
2.3 SFP optical module installation (optional)
Only use original SFP; Remove the dust cap, close the lock buckle and push it into the slot until it locks into place; Open the lock buckle and pull it out during disassembly, and promptly put on the dust cap; Non EEC optical modules will lower the maximum operating temperature of the entire machine.
2.4 Terminal Wiring (Divided into 4 Types of Terminals)
1) Power supply terminals (divided into four voltage specifications: T/F/U/P)
T:9.6~32VDC, Standard 24V DC;
F: 18~60VDC DC/18~30VAC AC;
U: PoE light load model, 18~30VDC, maximum PoE of the whole machine is 90W;
P: High power PoE models operate at 46-57VDC, with a maximum PoE of 240W for the entire machine;
Supporting dual redundant inputs, the device automatically draws high voltage power supply; Power off for ≥ 10ms.
2) FAULT Passive Relay
Always closed when there is no voltage, disconnected when there is a fault; Can monitor dual power loss, port disconnection, ring network failure, and machine self-test faults; Explosion proof scenarios strictly follow the limitations of physical capacitance/inductance parameters.
3) Digital DI input
2-pin terminal, standard 24V acquisition, compatible with two-wire/three wire sensors, used for external device signal access switch monitoring.
2.5 Data Cable Wiring Specification
Copper cable: Cat5e and above, twisted pair up to 100m; mandatory shielding network cable for gigabit/ship/railway scenarios; Separate the routing of strong and weak electrical cables to avoid parallel long distances and cross 90 ° to reduce coupling interference;
Fiber optic: Same type module docking (multi-mode to multi-mode, single-mode to single-mode), different SFP corresponding transmission distances (multi-mode 0-5km, ordinary single-mode 25km, long-distance LH up to 140km);
2.6 Power on and IP initialization
After the terminal is fully clamped and connected to the power supply, the whole machine self checks for about 60 seconds, and the LED flashes in full sequence;
Default parameters: IP automatic DHCP acquisition; Manage account admin (password private)/user (public read-only); Mandatory change of high-strength password for first-time login (case+number+special characters);
IP configuration channels: USB-ACA, HiVision, DHCP/BOOTP, Web, CLI;

Complete definition of LED indicator lights
Global indicator light for the entire machine
P power supply: green constant light=dual power supply; Huang Changliang=single power supply; Extinguish=Power undervoltage; Cycle 4 flash=firmware upgrade in progress;
FAULT red light: constantly on=relay disconnected with alarm; Extinguish=Device is functioning properly;
ACA: Green constant light=adapter connected; Flashing=read-write configuration; Yellow=abnormal adapter;
PoE: Yellow=Insufficient PoE power supply; Green=PoE normal output.
Port indicator light (LS green link/DA yellow data)
LS is constantly on: the link is normal; Extinguish: No connection; Cycle 1 Flash: Port standby; Cycle 3 Flash: Port Closed;
DA flashing: Port receiving and transmitting traffic; Extinguish: No data available.
RM ring network indicator light (HIPER Ring specific)
Extinguish=Ring network closed; Green always on=ring network activated, redundant ports disabled; Green flashing=ring network configuration error; Huang Changliang=Redundant ports enabled.
Maintenance and equipment disassembly
1. Daily maintenance
The whole machine has no random loss parts, only the FAULT relay ages with the number of on-off cycles, and the contact resistance is regularly checked in high-frequency scenarios;
Regularly clean the dust in the ventilation duct to avoid blockages that may cause excessive temperature;
The official website regularly updates firmware to obtain new features and fix vulnerabilities;
The storage/working temperature and humidity strictly follow the parameters to avoid condensation and high pollution environment.
2. Disassembly steps
Power off, unplug all network cables, fibers, and terminals USB;
Insert a straight screwdriver into the guide rail buckle and pull it down, then lift it up and remove the entire machine;
SFP disassembly: Open the lock buckle and pull it out, then cover it with a dust-proof protective cap.
Core technical parameters
1. Physical specifications
There are three types of body: narrow, medium, and wide. The plastic shell has an IP30 rating and the metal shell has an IP40 rating; Weight ranges from 380g to 1800g; Pollution protection level 2; Laser Class1; Vibration and impact comply with the IEC61131-2 industrial PLC standard.
2. Temperature and width grading
S/C standard type: 0 ℃~+60 ℃;
T/E/G wide temperature type: -40 ℃~+70 ℃;
The higher the altitude, the linear decrease in the maximum allowable temperature, and the operation above 2000m will be reduced; Storage temperature -40~85 ℃, humidity 1~95%, no condensation.
3. Power supply and PoE
4 voltage input specifications, the whole machine is equipped with non replaceable slow melting fuses;
PoE models are divided into U (maximum 90W) and P (maximum 240W output). The higher the power, the lower the upper limit of the ambient temperature, and there is a forced temperature derating curve.
4. Transmission distance
Twisted pair cable: Cat5e up to 100 meters in length;
Optical module: FastE multimode 4-5km, ordinary single-mode 25km, long-distance single-mode up to 140km; Gigabit/2.5G SFP covers multiple distances of 0.275-100+km.
5. EMC anti-interference
Complete static electricity, radio frequency, electrical fast pulse, surge, and conducted interference testing, while meeting the strict standards of general industry, railway EN50121, and ship DNV.
6. Supporting accessories
ACA22-USB-C configuration adapter, various specifications of SFP optical modules (ordinary/EEC wide temperature/bidirectional BiDi);
Spare terminals, DIN rail mounting bracket, HiVision network management software, HiOPC server;
Complete list of original factory order numbers for each model of complete machine.

K-JIANG
Add: Jimei North Road, Jimei District, Xiamen, Fujian, China
Tell:+86-15305925923