K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

JUMO dTRANS p35 Pressure Sensor Operation Manual with IO Link Interface

From: | Author:Wang | Time :2026-06-11 | 117 visit: | 🔊 Click to read aloud ❚❚ ▶ | Share:

JUMO dTRANS p35 Pressure Sensor Operation Manual with IO Link Interface

Basic Introduction and Safety Notice

1. Product Usage

This sensor is used for measuring and monitoring the gauge pressure and absolute pressure of liquids and gases, with built-in signal amplification and digital processing circuits; Equipped with IO Link 1.1 bidirectional communication interface, it can transmit process data, parameters, diagnostics, and status information, adapt to factory and mechanical automation systems, and is only allowed for indoor use.

2. Safety signs and warnings

CAUTION: Failure to operate as required can result in equipment damage and data loss.

Refer to document identification: The equipment documentation must be read to identify risks and take necessary precautions.

NOTE: Indicate key instructions for product usage and operation.

REFERENCE: Guide to refer to other chapters/accompanying manuals in the document.

3. Environmental and Media Risk Warning

High temperature surface: Measuring high-temperature media can cause the equipment casing to become hot, requiring shutdown for cooling, wearing protective equipment, or installing protective devices.

Hazardous media: Before coming into contact with corrosive or abrasive hazardous media, a risk assessment should be conducted in conjunction with the material safety data sheet to prevent leakage, fire, and personal injury.

4. Core usage restrictions

It does not belong to the safety accessories of pressure equipment and cannot be used for safety critical working conditions;

Prohibit installation and use in explosion-proof areas;

Equipment equipotential system needs to be connected through process interface.

5. Qualification requirements

Equipment installation, wiring, and debugging must be completed by qualified professionals.


Certification, Appearance, and Model Identification

1. Authoritative certification

Having multiple certifications such as UL, EHEDG, H2 ready, and China RoHS, it meets industry standards for food hygiene, hydrogen energy, electrical safety, and more.

2. Equipment structural components

The equipment consists of a status LED, a pressure interface with a diaphragm, an M12 electrical interface, and a transport protective cap; After power on, the dual green LEDs remain on, and after establishing an IO Link connection, the LEDs turn to flashing.

3. Nameplate information

The nameplate indicates the equipment name, order number, measurement range, power supply parameters, output type Device ID、 Production number; The production number can interpret the year and week of manufacture, and the Device ID is used to search for the matching IODD device description file.

4. Ordering coding rules

The complete order code is divided into 8 segments, defining the basic model, expansion type, measurement range, output form, pressure interface, interface material, electrical interface, and additional options:

Basic model: 402058 (dTRANS p35 IO Link pressure sensor);

Expansion types: regular, temperature resistant, customized versions;

Measurement input: Multiple gauge pressure/absolute pressure ranges are available for selection;

Output: Standard IO Link+digital switch output;

Pressure interface: including G-thread NPT、 Various specifications of sanitary clamps, dairy pipeline interfaces, PEKA sanitary interfaces, etc., with different interfaces corresponding to maximum pressure limits;

Interface material: standard 316L stainless steel;

Electrical interface: M12 × 1 circular plug;

Additional options: UL certification, vibration and moisture resistance, pressure channel throttling, hydrogen energy adaptation, etc.

5. Scope of Supply and Accessories

Standard supply: Sensor body+installation instructions;

Optional accessories: IO Link main station (4/8 channels, USB single channel), various connection cables, IODD files, on-site pre configured services, etc.


Detailed technical parameters

1. Measurement performance

Covering multiple gauge pressure and absolute pressure ranges, clarifying the linearity, full temperature accuracy, long-term stability, overload pressure, and burst pressure of each range; Equipped with range over/under limit detection function, output fixed error code in case of abnormality.

2. Output and switch characteristics

Two working modes:

IO Link mode: 1 IO Link communication output, 1 switch output;

SIO standard IO mode: 2 independent switch outputs.

Switch output: Supports PNP/NPN type, maximum single current of 100mA, voltage drop ≤ 2V, with short circuit, reverse polarity protection, and current limiting;

Functional parameters: Delay can be customized, window function delay is fixed at ± 0.25% of the range; The on-off delay of the switch can be adjusted from 0 to 100 seconds; The response time of the switch output is ≤ 7ms.

3. IO Link interface

Version: V1.1 (backward compatible with V1.0), baud rate COM3 (230.4kBaud);

Cable: unshielded cable with a maximum length of 20m and a minimum cycle time of 2ms;

The supporting IODD file can be downloaded from the manufacturer's official website or IO Link public platform.

4. Electrical parameters

Power supply: IO Link mode DC 18~32V, SIO mode DC 9.6~32V, nominal DC24V;

Power consumption: standby ≤ 10mA, IO Link operation ≤ 12mA, dual switch output maximum ≤ 250mA;

Electrical protection: Complies with Class III safety voltage requirements, and the circuit meets EN 61010-1 energy limiting specifications.

5. Environmental and mechanical parameters

Temperature: Conventional medium -40~+125 ℃, high temperature version can reach 200 ℃; Environmental temperature -40~+85 ℃;

Protection level: Gauge pressure type IP65, absolute pressure type IP65/IP67;

Mechanical performance: anti vibration and anti impact comply with IEC standards;

Material: The diaphragm/interface is made of 316L stainless steel, the high-pressure version uses 630 stainless steel, and the shell is made of 304 stainless steel;

Weight: Approximately 160g, unlimited installation posture, calibration posture requires the interface to face downwards.

6. Size and installation torque

Distinguish the structural dimensions of conventional, high-pressure, and sanitary types; Clearly specify the maximum installation torque for each pressure interface to avoid damaging the seal and threads.

Installation requirements

Universal installation: Install in any posture, ensure that the sealing ring/retaining ring is in place when tightening, and tighten according to the specified torque; Avoid interface position wear and tear.

EHEDG hygiene application requirements:

Select designated hygiene interfaces and support CIP in-situ cleaning;

No cavity, self draining interface, tank installation requires leveling, ensuring proper cleaning and spraying, and exposed leakage ports.

The pressure interface distinguishes the maximum pressure corresponding to different specifications, and mixing of over range interfaces is prohibited.


Electrical connection

1. M12 pin definition (A code)

Line color pin function

Brown BN 1 power supply L+

White WH 2 switch output 2

Blue BU 3 power supply L-

Black BK 4 IO Link/Switch Output 1

2. Key points of wiring

The equipment must be connected to the system's equipotential;

The UL certified version needs to be paired with cables of the same level of certification;

Provide typical wiring diagrams for PNP and NPN output types.


Equipment functions

1. Switch output function

Support hysteresis function, window function, and can set switch points, release points, and on/off delay; Distinguish between normally open/normally closed contact modes, and the delay function can filter out instantaneous pressure fluctuations.

2. Fine calibration

Used to correct measurement deviations, it can simultaneously adjust the zero point and slope, and adapt to on-site benchmark measurement values; Support quick entry of calibration upper and lower limit values through the teach function.

3. Teach one click function

Includes quick operations such as zero point calibration, factory reset, reset runtime, reset pressure maximum, etc., covering parameter, calibration, and operation and maintenance data reset.

4. Fault alarm

By using the IO Link event code, process data status bit, and numerical error code triple mechanism to report faults, it is possible to identify issues such as range over/under limit, parameter errors, hardware failures, probe disconnection/short circuit, undervoltage, temperature anomalies, etc., and define numerical error codes corresponding to each type of fault.


Parameter configuration

1. Configuration process

Using IO Link master station and supporting software, import device IODD files, establish connections, and complete parameter configuration, monitoring, and diagnosis.

2. Three major categories of parameters

Process data: cyclic transmission of pressure values, data status bits, switch output status; Supports floating-point/integer data format switching.

Configuration parameters: including data format, pressure offset, filtering time, switch output mode, event switch, fine calibration, etc., supporting read and write.

Operation and maintenance service data: read-only runtime, maximum/minimum pressure values; Support command reset statistics data and firmware version viewing; The data is automatically stored in EEPROM every 10 minutes.

Attention: The EEPROM has a write life of about 100000 times, and high-frequency parameter writing is prohibited to avoid memory damage.


Shutdown, scrapping, and compliance

Scrap disposal: Follow the WEEE Electrical Waste Directive, dispose of environmental protection according to local regulations, and contact manufacturers for recycling; Clear the data inside the equipment before scrapping.

Environmental certification: Through China RoHS, the harmful substance content of components such as shells, threads, and pressure interfaces meets the limit requirements.

  • Siemens 6SL3244-0SA01-1AA0 - SINAMICS G120 Control Unit
  • DANFOSS 175Z2688 - COATEDE CONTROLUNIT VLT5000
  • SIEMENS 6FM1721-3AA20 - Positioning Module
  • REXORTH VTS0605 PVAR S21 - Drive Module
  • BECKHOFF 2915-0000 - Control Module
  • COOPER EATON CGLine 400 40071347901 - CEAG CG Controller
  • SIEMENS 3UF5031-3AN00-1 - SIMOCODE DP Basic Unit
  • SIGMATEK DNC305 05-011-305 - Drive Controller
  • Multivac MV1 10249768 - Control Module
  • SCHNEIDER ELECTRIC MES114 59646 & 59645 - Circuit Breaker Accessory
  • CAMILLE BAUER CAPAX 44-580-0012 - Transmitter
  • HENGSTLER VT360P LS1/TOK - Encoder
  • BURKERT 8792 - 24V DC IP65 / IP67 Positioner
  • SENSOPART V10-OB-A1-W6 - Vision Sensor
  • ALLEN-BRADLEY 1762-L40BXB SER.C REV.J - MicroLogix 1200 Controller
  • HITACHI CPU22-02HC 33025801-2 - CPU Module
  • HITACHI AGH-0 33034810-2 - Control Board
  • PHILIPS AIH110 VER 1.0 - Control Module
  • BAUMULLER DO8000 - Drive Controller
  • B&R PS477 3PS477.9 Rev.C0 - Power Supply
  • ABB ALFA LAVAL 200-CISB - Communication Interface 2 x SatBus
  • Moeller MI4-570-TA1 - HMI Operator Panel
  • ABB ACH550-01-06A9-4+B055 - Variable Frequency Drive
  • ABB TPU2 3HNE00313-1 REV 12 - Teach Pendant Unit
  • Schneider Electric BRS368H130ABA - Stepper Motor
  • Foxboro FCM100E P0972ZA - I/A Series Communication Module
  • Siemens 6ES7 450-1AP00-0AE0 6ES7450-1AP00-0AE0 - Simatic S7 Version:04 Counter Module
  • Schneider Electric ATV320U07N4W - Altivar Machine Drive
  • Priva TouchPoint Flush V06:02 5060002 - Control Panel
  • Lenze ESMD402L4TXA - 4kW SMD Inverter Drive
  • Lenze ESMD402L4TXA - 4kW SMD Inverter Drive
  • Schneider Electric PM210 PM210MG - Powerlogic Power Meter
  • ASCOM U982-DB/1C U982 - Power Supply / Communication Module
  • DYADIC SYSTEMS SCN5-010-050-S03-NA - Servo Cylinder
  • Reliance Electric GMI-S04 - AC/AC CONVERTER 380/400V 50/60Hz 3.9/5.2A
  • Pro-Face GLC150-BG41-XY32KF-24V 3080060 PFXGLC150BDBP - Touch Screen HMI
  • ROFIN RSL TERMINAL V2 0185.01/03 - TERMINAL
  • HONEYWELL R7241E1077 - Burner Control / Amplifier
  • SEW MM22C-503-00 8241201 - 2.2kW Movimot Drive
  • Brand Digital III 50mL - Burette
  • Danfoss 195N0039 VLT2811PS2B20STR1DBF00A00C0 - 2.4kVA VLT Drive
  • SONY LG10-2 EK1 - Digital Gauge Indicator
  • EMERSON SKD3400750 - 7.5kW AC Drive
  • SIEMENS 6AV6 542-0AG10-0AX0 - MULTIPANEL HMI
  • TELEMECANIQUE ATV21HU55N4 - ALTIVAR21 5.5KW Variable Speed Drive
  • MITSUBISHI A985GOT-TBA-EU - GOT900 Touch Screen HMI
  • SCHNEIDER LXM32AD30N4 - Lexium 32 Servo Drive
  • SICK PSR01-1501 M20Z-02550A122 - Safety Laser Scanner
  • GECMA CHALLENGER 15-2-FMO - LITE TOUCH Monitor
  • Uniop EK02 6ZA982 - HMI Operator Panel
  • TELEMECANIQUE ATV18U54M2 - SQUARE D ALTIVAR 18 3kW Drive
  • Schneider Electric ATV312HU75S6 - 7.5kW Altivar 312 Drive
  • Siemens 6GK7243-5DX30-0XE0 6GK7 243-5DX30-0XE0 - Communications Processor
  • Schneider Electric LV432455 VIGI630 - 3POLE Earth Leakage Module
  • Rexroth PSI 6100.750 L1 R911170694-107 - frequency inverter / inverter
  • SWEDISH MICROWAVE AB Ku-Band BDC 138010-45-D0 - Block Downconverter
  • METTLER TOLEDO IND429 IND429-BB30 - Weighing Terminal
  • Siemens 6SL3210-5HE10-4UF0 - Sinamics V90 Servo Drive
  • B&R X20CP0482 Rev.D0 - X20 CPU Module
  • Mitsubishi FR-E720S-110SC-EC FRE720S110SCEC - 31A~11A Drive With Filter
  • ABB ACH580-01-026A-4 - Variable Frequency Drive
  • Siemens 6SL3210-1KE13-2AP1 - SINAMIC G120CDP 1.1kw Drive
  • Schneider Electric TM250D 4P3D LV431440 - Compact NSX250 Circuit Breaker
  • RELIANCE ELECTRIC GD.722.81.00-A 802288-74C - MAXITRON Servo Control Card
  • Uniop EK02 6ZA982 - HMI Operator Panel
  • Siemens 6SE9113-7JA13 - MICRO MASTER Junior 1.5kW Inverter
  • Mitsubishi FR-E720S-110SC-EC FRE720S110SCEC - 31A~11A Drive with Filter
  • Johnson Controls FEC2621 MS-FEC2621-0 - Field Equipment Controller
  • BENDER IR475LYT-429 - A-ISOMETER Insulation Monitor
  • Berger lahr D550 RS15 22.550-00-30b - Stepper Drive
  • Rexroth PSI 6100.750 L1 R911170694-107 - Frequency Inverter / INVERTER
  • KOYO 205 D2-06B-1 D2-240 H2-ECOM D2-08ND3 F2-08TRS - DIRECT LOGIC PLC WITH MODULE
  • TELEMECANIQUE ATV18U54M2 ATV18U54M - SQUARE D ALTIVAR 18 3kW Drive
  • Lenze 471-E1.D - Board / Controller Speed
  • Mitsubishi FR-A740-00038-EC - Frequency Inverter
  • Johnson Controls IOM3723 MS-IOM3723-0 - Input/Output Module
  • CURTIS 1238-5602 - AC Motor Controller
  • FOXBORO P0912XX REV.A - 220VAC Power Supply
  • Siemens 6SE9113-7JA13 - MICRO MASTER Junior 1.5kW Inverter
  • Mitsubishi FR-A740-00038-EC - Frequency Inverter
  • KOYO 205 D2-06B-1 D2-240 H2-ECOM D2-08ND3 F2-08TRS - DIRECT LOGIC PLC WITH MODULE
  • AUTZ M406D-00101 - Servo Motor
  • Lauer PCS095 PG095.508.BB - Operator Panel
  • ABB SCOP45SB/DX232 - SattCon OP45 SB Operator Panel
  • SEW Eurodrive MCH42A0030-5A3-4-00 MDX60A0030-5A3-4-00 - 4.8kVA Movidrive Inverter
  • BENDER IR475LYT-429 - A-ISOMETER Insulation Monitor
  • Johnson Controls FEC2621 MS-FEC2621-0 - Field Equipment Controller
  • Johnson Controls IOM3723 MS-IOM3723-0 - Input/Output Module
  • Berger lahr D550 RS15 22550-00-30b - Stepper Drive
  • SIEMENS 6FX1120-4BD03 6FX11204BD03 5702049304.00 E-Stand: A - Sinumerik Module
  • Allen-Bradley 1771-NIV B - HIGH RESOLUTION ISOLATED ANALOG SERIES Module
  • HONEYWELL XFC2D06001 - Flow Computer / Controller
  • Contraves Varidyn Compact ADB 380.90M - DC Drive 380v - 400v 90A 50kVA
  • Red Lion Control GEM52000 - Control Module
  • Siemens 6ES5 955-3NC13 - modular power supply TYPE:DIN41752
  • Danfoss ICV50 G20Mn50T / 027H5200 - Valve zaw
  • Eberle PLS508 P-814 / 2X EA-88 / A-812 / MT-81 / S-11 - PLC with Modules
  • Siemens 6ES7 314-6CF01-0AB0 6ES7314-6CF01-0AB0 - SIMATIC CPU314C-2 DP
  • EBERLE EM-525-87 EM52487 - ICE DETECTOR BASE UNIT
  • Telemecanique / Schneider TSXRKZ02 - TSX Micro automation plus 7module
  • B&R 5DLSDL.1001-00 - Display Link Receiver
  • Siemens 6FX1120-4BD03 6FX11204BD03 5702049304.00 E-Stand: A - Sinumerik Module
  • ALLEN-BRADLEY 1771-NIV A - HIGH RESOLUTION ISOLATED ANALOG SERIES Module
  • ALLEN-BRADLEY 1771-NIV B - HIGH RESOLUTION ISOLATED ANALOG SERIES Module
  • Contraves Varidyn Compact ADB 380.90M - DC Drive 380V - 400V 90A 50kVA
  • Contraves Varidyn Compact ADB 380.90M - DC Drive 380V - 400V 90A 50kVA
  • Ropex RES-202 - Resistron Temperature Controller
  • HONEYWELL XFC2D06001 - Flow Computer / Controller
  • Telemechanics ATV452U40 - DIMMER ALTIVAR5 SERIES 452 4kW 5HP Frequency Inverter
  • VEGA VEGAPLUS61 PS61.XXAGPHAMAX - Radar Level Sensor
  • BRANSON ULTRASONIC TRANSDUCER - Ultrasonic Transducer
  • Danfoss ICV50 G20Mn50T / 027H5200 - Valve Valvola Zaw
  • Schneider Electric 2001549/1 GALAXY PW 5102851200 NT07 - panler card
  • REXROTH VT3006-36 A - Proportional Valve Amplifier
  • Allen-Bradley 1746-OBP16 SERIES:C - SLC 500 OUTPUT MODULE
  • SCHNEIDER LXM32MD12N4 - Lexium 32 Servo Drive
  • Schneider Electric ATV630U22N4 - 2.2KW Altivar Process Drive
  • Allen-Bradley 1746-OBP16 SERIES:C - SLC 500 OUTPUT MODULE
  • Vanderlande 0E2550-00002... - Bagtrax Integrated Power Module 400V 32A
  • B&R X20CP0410 Rev.D0 - X20 CPU Module
  • VANDERLANDE 0E2550-00002 02EDD2B0100 - BAGTRAX Integrated Power Module 400V 32A
  • Rexroth R061205010 - Linear Bushing / Bearing
  • INDRAMAT TVM1.2-50-220/300-W0-220/380 - Power Supply Module
  • Vanderlande 0E2550-00002... - Bagtrax Integrated Power Module 400V 32A
  • HOMAG KEB 07F5S1A-YA00 09E5T60-1001 - Combivert Inverter WITH KEYPAID AND FILTER
  • Siemens 3RW3047-1BB14 - Soft Starter
  • Sumitomo AF-500 AF502-A40 - 0.4kW Transistor Inverter
  • Sumitomo AF-500 AF502-A40 - 0.4kW Transistor Inverter